• Title/Summary/Keyword: DC field

Search Result 1,042, Processing Time 0.031 seconds

The Shift of Threshold Voltage and Subthreshold Current Curve in LDD MOSFET Degraded Under Different DC Stress-Biases (DC 스트레스에 의해 노쇠화된 LDD MOSFET에서 문턱 전압과 Subthreshold 전류곡선의 변화)

  • Lee, Myung-Buk;Lee, Jung-Il;Kang, Kwang-Nham
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.5
    • /
    • pp.46-51
    • /
    • 1989
  • The degradation phenomena induced by hot-carrier injection was studied from the shift of threshold voltage and subthreshold current curve in LDD NMOSFET degraded under different DC stress-biases. Threshold voltage shift ${Delta}V_{tex}$ defined in saturation region was separated into contri butions due to trapped oxide charge $V_{ot}$ and interface traps ${Delta}V_{it}$ generated from midgap to threshold voltage. Under th positive stress electric field (TEX>$V_g>V_d$) condition, the shift of threshold voltage was attributed to the electrons traped ar gate oxide but subthreshold swing was not negative stress electric field ($V_g) condition, holes seems to be injected positive charges so threshold voltage and subthreshold swing were increased.

  • PDF

A Continuous Electrical Cell Lysis Chip using a DC Bias Voltage for Cell Disruption and Electroosmotic Flow (한 쌍의 전극으로 전기 삼투 유동과 세포 분쇄 기능을 동시에 구현한 연속적인 세포 분쇄기)

  • Lee, Dong-Woo;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.10
    • /
    • pp.831-835
    • /
    • 2008
  • We present a continuous electrical cell lysis chip, using a DC bias voltage to generate the focused high electric field for cell lysis as well as the electroosmotic flow for cell transport. The previous cell lysis chips apply an AC voltage between micro-gap electrodes for cell lysis and use pumps or valves for cell transport. The present DC chip generates high electrical field by reducing the width of the channel between a DC electrode pair, while the previous AC chips reducing the gap between an AC electrode pair. The present chip performs continuous cell pumping without using additional flow source, while the previous chips need additional pumps or valves for the discontinuous cell loading and unloading in the lysis chambers. The experimental study features an orifice whose width and length is 20 times narrower and 175 times shorter than the width and length of a microchannel. With an operational voltage of 50 V, the present chip generates high electric field strength of 1.2 kV/cm at the orifice to disrupt cells with 100% lysis rate of Red Blood Cells and low electric field strength of 60 V/cm at the microchannel to generate an electroosmotic flow of $30{\mu}m/s{\pm}9{\mu}m/s$. In conclusion, the present chip is capable of continuous self-pumping cell lysis at a low voltage; thus, it is suitable for a sample pretreatment component of a micro total analysis system or lab-on-a-chip.

THE SPEED CONTROL OF DC SERIER WOUND MOTOR USING DSP (TMS320F240)

  • Bae, Jong-Il;Je, Chang-Woo;Lee, Man-Hyung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.371-376
    • /
    • 2003
  • In general, the electronic forklift driven by DC motor drive system is used in the industrial field. Classically, the DC motor is controlled by speed control using proportion control method, by output torque following the load on the plane like a manual operation. But in the industrial field, the electronic forklift is demanded the robust drive mode. Some cases of the mode, there are trouble in torque and speed control following slope capacity. The control is sensitive concerning with slope angle and output speed, various control method is studied for stability of speed control. We apply speed controller for the self-tuning using DSP(TMS320F240) as main controller for high speed processor, embody dynamic characteristic of control compared the PI control to the fuzzy control.

  • PDF

Performance Analysis of Brushless DC Motor According to Polar Magnetizing Characteristic of Ferrite Bonded Permanent Magnet (페라이트 본드 영구자석의 극이방 자화특성에 따른 BLDC 모터의 특성해석)

  • Baek, Soo-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.12
    • /
    • pp.2173-2178
    • /
    • 2010
  • The magnetization directions of a polar magnetized ferrite bonded magnet are analyzed by finite element method (FEM). The influence of the width of SmCo magnets for magnetic field generation is investigated. The surface flux densities of the polar anisotropic magnets are analyzed and compared according to the pole number and thickness of the magnets. And the electromotive force (EMF) values of brushless DC motors with the magnets are investigated. The validity of the analysis method is verified by comparing the analyzed results with measured ones.

Characteristics of Hydrogenated Amorphous Carbon (a-C:H) Thin Films Grown by Close Field UnBalanced Magnetron Sputtering Method (비대칭 마그네트론 스퍼터링법으로 성장된 a-C:H의 물리적 특성)

  • 박용섭;홍병유
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.3
    • /
    • pp.278-282
    • /
    • 2004
  • The Hydrogenated amorphous carbon(a-C:H) thin films are deposited on silicon with a close field unbalanced magnetron(CFUBM) sputtering systems. The experimental data are obtained on the depositon rate and physical properties of a-C:H films using DC bias voltage and Ar/C$_2$H$_2$ pressure. The depostion rate and the surface roughness decrease with DC bias voltage, but the hardness of the thin films increases with DC bias voltage. And the position of G-peak moves to lower wavenumber indicating an increase in diamond-like carbon characteristics with the lower Ar/C$_2$H$_2$ pressure.

Effects of Seed Pre-treatment on Field Germination of Zanthoxylum piperitum DC. (초피나무 종자의 전처리가 포장에서의 출아에 미치는 영향)

  • 김인재;김민자;남상영;박재호;이철희;김홍식
    • Korean Journal of Plant Resources
    • /
    • v.16 no.2
    • /
    • pp.141-146
    • /
    • 2003
  • To improve the percentage of field germination of Zanthoxytum piperitum DC., storage in ground(control) and several chemicals as treatments was investigated. Germination percentage was 30.3 and 22.7% in GA$_3$(100 ppm) and NaCIO(10%), respectively compared with 17.3% in storage in ground without treatments. Germination percentage reached maximum between 26 and 33 days after seeding and then increased slowly. Top/Root ratio was the highest at storage in ground after the treatment of GA$_3$ 100ppm.

Satistical Analysis of SiO2 Contact Hole Etching in a Magnetically Enhanced Reactive Ion Etching Reactor

  • Liu, Chunli;Shrauner, B.
    • Journal of Magnetics
    • /
    • v.15 no.3
    • /
    • pp.132-137
    • /
    • 2010
  • Plasma etching of $SiO_2$ contact holes was statistically analyzed by a fractional factorial experimental design. The analysis revealed the dependence of the etch rate and DC self-bias voltage on the input factors of the magnetically enhanced reactive ion etching reactor, including gas pressure, magnetic field, and the gas flow rates of $CHF_3$, $CF_4$, and Ar. Empirical models of the DC self-bias voltage and etch rate were obtained. The DC self-bias voltage was found to be determined mainly by the operating pressure and the magnetic field, and the etch rate was related mainly to the pressure and the flow rates of Ar and $CHF_3$.

Comparison Analysis of Field Test Methods Based on Technical Criteria of Electrolytic Corrosion Protection in Urban Railway (도시철도 전식방지 기술기준에 따른 시험방법 비교분석)

  • Kim, Jae-Moon;Jung, Ho-Sung
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1885-1891
    • /
    • 2010
  • Recently metropolitan local governments is actively introducing urban railway's expand and light rail transit as a means of new transport system. DC electricity feeder system operating in the domestic urban railway is typically a feedback circuit consisted of the contact wire and electric railway vehicle via rail. But stray current is to be defined as a current flowing on a structure that is not part of the intended electrical circuit with respect to a given structure. Stray current is generally results from the leakage of return currents from large DC traction systems that are grounded or have a bad earth-insulated return path. At the place where the current leaves the rail and metallic structures, electrolytic corrosion may take place. This paper presents comparison analysis of field test methods based on criteria of electrolytic corrosion protection of buried metallic structures adjacent to DC traction systems.

  • PDF

The Performance Analysis of Direct Current Electromagnetic Propulsion in Seawater

  • Kong, Yeong-Kyung;Park, Tai-In;Kim, Yun-Sik;Noh, Chang-Joo
    • Journal of Energy Engineering
    • /
    • v.2 no.1
    • /
    • pp.38-44
    • /
    • 1993
  • Electromagnetic seawater thrusters may be classified into four general categories : internal duct dc, external field dc, internal peristaltic ac, and external peristaltic ac. Internal duct dc thrusters offer the advantages of low magnetic field leakage, simple construction, and potentially high reliability. The most efficient internal duct configuration consists of converging inlet nozzle and a straight discharge duct. Ideal efficiency calculations based on the one-dimensional Bernoulli equation show that thrusters should be designed with large cross-sectional areas and operate at low discharge velocities. In practice, this may be accomplished by using multiple thruster ducts. Conductivity enhancement, high magnetic fields, and long electrodes will also improve efficiency.

  • PDF

A Result of the Field Test for Regenerative Inverter (직류급전시스템의 에너지회생장치 적용을 위한 실계통 부설 시험)

  • Kim, Joo-Rak;Han, Moon-Seob;Jang, Dong-Uk;Kim, Jung-Hoon
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.286-293
    • /
    • 2008
  • DC transit system has been adopted in the metropolitan area, Korea since 1974. EMU in this system always reiterates that acceleration and retardation. When EMU decelerates using electric breaking, regenerative power occurs. Regenerative power can be consumed in vicinity EMC on the same line or in resistor. If DC transit system has inverter for reusing regenerative power, Energy efficiency in DC transit system will be increased. This paper present the developed inverter for regenerative power and its field test. Test result of developed inverter is presented.

  • PDF