• Title/Summary/Keyword: DC current measurement

Search Result 232, Processing Time 0.025 seconds

Resistive Switching in Vapor Phase Polymerized Poly (3, 4-ethylenedioxythiophene)

  • Kalode, P.Y.;Seong, Myeong-Mo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.384-384
    • /
    • 2012
  • We report nonvolatile memory properties of poly (3, 4-ethylenedioxythiophene) (PEDOT) thin films grown by vapor phase polymerization using FeCl3 as an oxidant. Liquid-bridge-mediated transfer method was employed to remove FeCl3 for generation of pure PEDOT thin films. From the electrical measurement of memory device, we observed voltage induced bipolar resistive switching behavior with ON/OFF ratio of 103 and reproducibility of more than 103 dc sweeping cycles. ON and OFF states were stable up to 104 seconds without significant degradation. Cyclic voltammetry data illustrates resistive switching effect can be attributed to formation and rupture of conducting paths due to oxidation and reduction of PEDOT. The maximum current before reset process was found to be increase linearly with increase in compliance current applied during set process.

  • PDF

Study of the Driving Characteristics in the Magnetic Fluid Linear Pump by AC Operating Currents (Magnetic Fluid Linear Pump의 AC 전류에 의한 운전 특성에 관한 연구)

  • Park Gwan Soo;Seo Kang
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.3
    • /
    • pp.111-119
    • /
    • 2005
  • In the magnetic fluid linear pump, the pumping forces and pumping speed mainly depend on the current patterns. In this research, a new design to reduce the discontinuities of the pumping forces of the MFLP was studied. Continuous pumping of the newly designed MFLP by using AC current increases pumping efficiency and reduces the pumping force. Forming shapes of the magnetic fluid at the intermediate state were computed and compared to measurement. Since the back flow of the fluid is reduced remarkably, 4 yoke's AC driving is more efficient than 7 yoke's DC driving. The size, weight and pumping discontinuity are also reduced.

Resistive shunt with low phase angle under harmonic effect (고조파 영향에 의한 위상 변화가 적은 분류기)

  • Lee, J.H.;Park, Y.T.;Lee, M.M.;Seo, J.H.;Jang, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.285-287
    • /
    • 1997
  • An AC shunt with low phase angle has been designed for an AC current measurement, such as currents with harmonics. This $0.2\;{\Omega}$ shunt of 5 A rated current is composed of fifty $10\;{\Omega}$ metal film resistors and applicable to the frequency band of DC to 1 kHz.

  • PDF

Reference Point Projection Method for Improved Dynamics of Solar Array Hardware Emulation

  • Wellawatta, Thusitha;Choi, Sung-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.126-128
    • /
    • 2018
  • Solar array simulator (SAS) is a special DC power supply that regulates the output voltage or current to emulate characteristics of photovoltaic (PV) panels. Especially, the control of SAS is a challenging task due to the nonlinearity in the output curve, which is dependent on irradiance as well as temperature and is determined by panel materials. Conventionally, both current-mode control and voltage-mode control should be alternated by partitioning the operating curve into multiple sections, which is not only for the measurement noise problem with the feedback sensing but also for the control stability issue near the maximum power point. However, the occurrence of transition among different controllers may deteriorate the overall performance. To eliminate the mode transitions, a novel single controller scheme has been introduced in this paper, where the reference operating projection technique enables simple, smooth and numerically stable control. Theoretical consideration on the loop stability issue is discussed and the performance is verified experimentally for the emulation of a PV panel data in view of stability and response speed.

  • PDF

Development of UBMS(Unbalanced Magnetron Sputtering) System and Ion Current Density Measurement of Copper Target (UBM 마그네트론 스퍼터 시스템을 이용한 구리 타겟의 이온전류밀도 향상 연구)

  • Kang, Chunghyeon;Joo, Junghoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.50 no.3
    • /
    • pp.192-197
    • /
    • 2017
  • A 6-way-cross consisting of a 2.75-inch CF flange was used as a main chamber on a PFEIFFER VACUUM TMP station based on a 67 l / sec turbo molecular pump and a diaphragm pump to produce a magnet array with a volume ratio of 5.5: 1.A 1-inch diameter copper target and graphite target were fabricated using MDX-1.5K from Advanced Energy Industries, Inc as a DC power supply. Ion current density of copper target and graphite target was measured by unbalanced magnetron sputtering. The basic pressure condition was $6.3{\times}10^{-7}mbar$ and the process pressure was Ar 50 sccm at $1.0{\times}10^{-2}mbar$ (7.5 mTorr) in the Ar atmosphere. Therefore, the relative density of copper ions reaching the substrate with the measured ion current density was derived.

Fabrication and characterization of n-IZO / p-Si and p-ZnO:(In, N) / n-Si thin film hetero-junctions by dc magnetron sputtering

  • Dao, Anh Tuan;Phan, Thi Kieu Loan;Nguyen, Van Hieu;Le, Vu Tuan Hung
    • Journal of IKEEE
    • /
    • v.17 no.2
    • /
    • pp.182-188
    • /
    • 2013
  • Using a ceramic target ZnO:In with In doping concentration of 2%, hetero-junctions of n-ZnO:In/p-Si and p-ZnO:(In, N)/n-Si were fabricated by depositing Indium doped n - type ZnO (ZnO:In or IZO) and Indium-nitrogen co-doped p - type ZnO (ZnO:(In, N)) films on wafers of p-Si (100) and n-Si (100) by DC magnetron sputtering, respectively. These films with the best electrical and optical properties were then obtained. The micro-structural, optical and electrical properties of the n-type and p-type semiconductor thinfilms were characterized by X-ray diffraction (XRD), RBS, UV-vis; four-point probe resistance and room-temperature Hall effect measurements, respectively. Typical rectifying behaviors of p-n junction were observed by the current-voltage (I-V) measurement. It shows fairly good rectifying behavior with the fact that the ideality factor and the saturation current of diode are n=11.5, Is=1.5108.10-7 (A) for n-ZnO:In/p-Si hetero-jucntion; n=10.14, Is=3.2689.10-5 (A) for p-ZnO:(In, N)/n-Si, respectively. These results demonstrated the formation of a diode between n-type thin film and p-Si, as well as between p-type thin film and n-Si..

Evaluation of On-Line Partial Discharge Measurement Techniques on Hydro-Generator (수력 발전기의 운전중 부분방전 측정기법에 대한 신뢰성 평가)

  • Hwang, D.H.;Kim, J.B.;Kim, Y.J.;Park, M.S.;Kim, T.S.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1526-1529
    • /
    • 1994
  • In hydro-generator, a groundwall insulation of stator windings gradually deteriorates due to mechanical, thermal, electrical and environmental stresses. These stresses combine to result in loose windings, delamination of the stator insulation and/or electrical tracking of the end winding, all of which can lead to stator insulation failures. Conventionally, off-line tests such as partial discharge measurement, DC/AC current test and ${\Delta}tan{\delta}$ test has been used for estimation of winding condition. However, off-line test requires large power supply and generator outage. In addition, major cause of insulation problems such as loose wedges and slot discharges may not be found with off-line diagnoses. This paper describes the on-line partial discharge measurement techniques in the generator stator windings. The experimental results from the UIAM #1 hydro-generator confirms a optimistic application of on-line generator diagnosis method as a reliable tool for evaluation of winding condition.

  • PDF

A Study on TTX Traction Characteristics using Measurement System (계측시스템을 활용한 틸팅열차 추진장치 특성 연구)

  • Han, Young-Jae;Lee, Su-Gil;Park, Choon-Soo;Han, Seong-Ho;Lee, Jun-Seok;Jung, Kwon-Il
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.12
    • /
    • pp.1093-1098
    • /
    • 2007
  • Tilting trains are currently in operation in 13 countries around the world. With the advances in tilting technology, verification of economic efficiency, and changes in economic situations, the introduction of tilting trains will rapidly spread across the globe. The measurement system is composed of the industrial computers installed in the console and the measurement racks mounted on each car. It is utilized to accumulate the data by the communication card and the optical cable. The optical cable and power cable are coupled at the connector located in joint of train to make easy to disconnect car each other. The signal conditioner is designed to choose and to extend the channel for each sensor readily. The sensor measurement rack has adopted as decentralization method. It is installed in each car to minimize the cable length. In also, it is manufactured based on 19"rack and covered to protect the cable. In this study, the programs for measurement and analysis were also developed to understand the traction system characteristics of TTX. Using this measurement system, we studied that acceleration test, re-powering test, and gradually powering test. The acceleration performance of TTX is 1.735 km/h/s, and it is inner standard value. The notch test result from 1 to 7 steps, DC link voltage is under standard value, and the output electric current of inverter is controlled normally. From the test results, we saw the performances of the traction systems are normal.

Large-Scale Current Source Development in Nuclear Power Plant (원전에 사용되는 직류전압제어 대전류원의 개발)

  • Jong-ho Kim;Gyu-shik Che
    • Journal of Advanced Navigation Technology
    • /
    • v.28 no.3
    • /
    • pp.348-355
    • /
    • 2024
  • A current source capable of stably supplying current as a measurement medium is required in order to measure and test important facilities that require large-scale measurement current, such as a control element drive mechanism control system(CEDMCS), in case of dismantling a nuclear power plant. However, it can provides only voltage power as a source, not current, although direct voltage controlled constant current source is essential to test major equipment. That kind of source is not available to supply stable constant current regardless of load variation. It is just voltage supplier. Developing current source is not easy other than voltage source. Very large-scale current source up to ampere class more than such ten times of normal current is inevitable to test above mentioned equipment. So, we developed large-scale current source which is controlled by input DC voltage and supplies constant stable current to object equipment according to this requirement. We measured and tested nuclear power plant equipment using given real site data for a long time and afforded long period load test, and then proved its validity and verification. The developed invetion will be used future installed important equipment measuring and testing.

Operation experience of 2 GeV PLS magnet power supplies (포항방사광가속기 2GeV 저장링용 전자석전원 장치의 운전경험)

  • Nam, Sang-H.;Jeong, Seong-H.;Han, Sung-H.;Suh, Jae-H.;Ha, Ki-M.;Yoon, Moo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.559-563
    • /
    • 1996
  • Total 215 magnet power supplies are under operation in Pohang Light Source(PLS). Current, voltage and peak power handling capabilities of DC power supply are in the range of 21 to 643V, 45 to 850A and 0.94 to 531KW, respectively. The DC power supplies can be categoriezed as uni-polar and bipolar power. Typical required stability and ripple of uni-polar power supplies are ${\pm}0.005%$ and ${\pm}0.05%$, respectively. The bipolar power supplies should be maintained within ${\pm}0.05%$ stability and ${\pm}0.5%$ ripple. Precise measurement results show that all power supplies meet or exceed the required specifications. The long term operation reliability to be sufficient for a stable operation of the Pohang Light Source.

  • PDF