In this paper, a high reliability 30W DC-DC converter is designed considering military standard (MIL-STD) for military applications such as guided weapon and aircraft. The performances and specifications of conventional military grade DC-DC converter are practically analyzed. The requirements for military grade DC-DC converter are established in consideration of MIL-STD and analysis results of conventional product. Two isolated DC-DC converter, forward and fly-back converter, are designed and compared to determine topology. From experimental results under various operating conditions, the forward topology satisfied performances and specifications of MIL-STD for military DC-DC converter.
본 논문에서는 휴대기기용 DC-DC 부스트 컨버터를 설계하였다. 제안하는 DC-DC 부스트 컨버터는 1MHz의 스위칭 주파수로 구동되며, 인덕터, 출력 커패시터, MOS 트랜지스터 등으로 이루어지는 파워단 부분과 보호회로단, 컨트롤블럭단으로 구성하였다. CMOS magnachip $0.18{\mu}m$ 공정을 이용하여 SPICE 모의실험을 통하여 동작을 확인하였고, 칩을 제작하여 모의실험결과와 비교 분석하였다. 설계된 컨버터는 3.3 V 입력 전압 조건에서 출력전압 4.8 V 가 나타났고, 출력전류 95 mA 로 기존의 25~50 mA보다 큰 출력을 얻었다.
본 논문은 고주파 절연형 소프트 스위칭 PWM DC-DC 컨버터의 효율을 높일 수 있는 새로운 회로를 제안하였다. 제안한 DC-DC 컨버터는 고주파 변압기의 여자전류를 이용하지 않고 인덕턴스를 이용하였다. 그리고 고주파 절연 변압기 2차측에 동기 정류용 전력용 MOSFET에 새로운 기능을 부가한 온-오프 제어 방식을 이용하여 넓은 부하 범위에 걸쳐 안정된 영전압 스위칭(ZVS)동작을 실현하였다. 그 결과 제안한 DC-DC 컨버터의 실험 장치에 의해서 효율을 97[%]이상 달성하였다.
Recently, DC distribution systems become hot issues since DC type loads increase rapidly according to the expansion of IT equipment such as computers, servers, and digital devices; DC type loads will cover 50% for all electricity loads in 2020 which was mere 10% in 2000. DC distribution systems are also accelerated by the expansion of renewable power systems since they are easy to be interfaced with DC grids rather than AC grids. However, removing the fault current in DC grids is comparably difficult since the current in DC grids has non zero-crossing point like in AC grids. Thus, developing dedicated DC circuit breakers for DC grids is necessary to get safety for human and electrical facilities. Magnet arc extinguishing method is proper to small size DC circuit breakers. However, simple Magnet arc extinguishing method is not enough to break inductive fault currents. This paper proposed a novel DC circuit breaker against inductive fault current defined by IEEE C37.14-2004 Standard for Low-Voltage DC Power Circuit Breakers Used in Enclosures. The performance of the proposed DC circuit breaker was verified by an experimental circuit breaker test system built in this research.
DC/DC converters are commonly used to generate regulated DC output voltages with high-power efficiencies from different DC input sources. The converters can be applied in the regenerative braking of DC motors to return energy back to the supply, resulting in energy savings for the systems at periodic intervals. The fundamental converter studied here consists of an IGBT (Insulated Gate Bipolar mode Transistor), an inductor, a capacitor, a diode, a PWM-IC (Pulse Width Modulation Integrated Circuit) controller with oscillator, amplifier, and comparator. The PWM-IC is a core element and delivers the switching waveform to the gate of the IGBT in a stable manner. Display of the DC/DC converter output depends on the IGBT's changes in the threshold voltage and PWM-IC's pulse width. The simulation was conducted by PSIM software, and the hardware of the DC/DC converter was also implemented. It is necessary to study the fact that the output voltage depends on the duty rate of D, and to compare the output of experimental result with the theory and the simulation.
전기 전자 및 제어기의 직류 안정화 전원으로 널리 이용되고 있는 DC-DC 전력 변환기인 기존의 승압 컨버터는 반도체 소자의 고속스위칭에 의해 고효율, 소형 및 경량화 되어가고 있지만, 전류 평활용으로 철심 리액터 및 콘덴서가 존재하여 한계가 있다. 기존의 승압용 DC/DC 전력 변환기는 에너지 전달을 위해 하나 이상의 인덕턴스가 필요로 하며, 이는 철손으로 인한 효율 저하 및 경제성에 큰 단점이 되고 있다. 일반적으로 DC/DC 컨버터에서 리액터의 추가는 1개당 $1{\sim}2[%]$의 효율저하를 초래한다. 따라서 최근 고효율 DC/DC 컨버터에서 리액터의 제거 및 최소화에 대한 연구가 활발히 진행되고 있다. 본 논문은 공심 리액터를 이용한 DC/DC 컨버터에 대한 연구로서, ZCS용 공심 리액터를 사용하는 새로운 구조의 절연형 다중레벨 DC/DC 컨버터를 제안하고, PSIM을 이용한 시뮬레이션을 통하여 그 타당성을 검증하였다.
본 논문에서는 연료전지용 전력변환 장치에서 높은 승압비를 구현하기 위하여 절연형 풀브릿지 컨버터의 고주파 변압기 2차측을 직렬로 연결한 새로운 DC/DC 컨버터와 이에 적합한 가변 위상변위 스위칭 방식을 제안하였다. 제안된 컨버터는 기존 방식에 비해 정류부와 필터부의 일원화가 가능한 구조로 출력레벨의 증가를 위해 컨버터의 수를 증가 하더라도, 수동소자의 수를 대폭 줄일 수 있다. 제안된 직렬 방식의 컨버터의 출력전압은 기존의 일정위상변위 스위칭 방식으로는 극성이 반대로 되는 구간이 발생하므로, 제안된 전력변환기에 적합한 간단한 가변 위상 변위 스위칭 방식을 적용함으로써, 출력전압의 감소문제를 해결하였으며, 시뮬레이션과 실험을 통하여 제안된 방식의 타당성을 검증하였다.
This paper proposes a high-efficiency DC-DC converter with improved dynamic response characteristics for modular photovoltaic power conversion. High power efficiency is achieved by reducing switching power losses of the DC-DC converter. The voltage stress of power switches is reduced at primary side. Zero-current switching of output diodes is achieved at secondary side. A modified proportional and integral controller is suggested to improve the dynamic responses of the DC-DC converter. The performance of the proposed converter is verified based on a 200 [W] modular power conversion system including the grid-tied DC-AC inverter. The proposed DC-DC converter achieves the efficiency of 97.9 % at 60 [V] input voltage for a 200 [W] output power. The overall system including DC-DC converter and DC-AC inverter achieves the efficiency of 93.0 % when 200 [W] power is supplied into the grid.
This study proposes a new voltage balancer with bidirectional DC-DC converter function. The proposed balancer can serve as a voltage balancer and a bidirectional DC-DC converter. Thus, the balancer can be applied to battery management systems or fast chargers in electric vehicles (EVs) charging stations while balancing bipolar DC bus voltages. The proposed system has unlimited voltage balancing range unlike the conventional voltage balancing control using a three-level DC-DC converter. A comparison of the voltage balancing range between the proposed and conventional scheme is explored to confirm this superiority. Simulation and experimental results are provided to validate the effectiveness of the proposed system.
휴대용 전자제품의 증가에 따라 배터리의 사용 시간을 증가시키기 위한 파워메니지먼트 회로의 설계는 매우 중요해 지고 있다. 이에 따라 switching power supply, 특히 DC-DC 변환기의 필요성은 더욱 커지고 있다. 기존 DC-DC 변환기용 컨트롤로 칩들은 순수한 아날로그 방식으로 설계되어 왔었다. 본 논문에서는 아날로그 방식의 단점을 극복하기 위한 디지털방식 컨트롤러 칩의 제작 및 측정된 연구 결과를 소개한다. 디지털 컨트롤러의 장점으로는 설계시간이 빠르고, 설계 변경을 쉽게 할수 있다는 점이다. 그러나 DC-DC 컨버터의 최종 출력 전압은 아날로그 전압이기 때문에, 아날로그를 디지털로 변환해 주는 장치가 디지털 컨트롤러에는 필수적이다. 본 논문에서는 기존의 flash 방식의 데이터 변환기 대신에 회로설계가 단순화된 델타시그마 모듈레이션을 사용하여 아날로그 신호를 디지털 신호로 변환하였다. 개발된 CMOS 컨트롤로 칩은 테스트 보드 측정을 통하여 성공적인 동작이 검증되었다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.