• Title/Summary/Keyword: Cycle frequency

Search Result 1,049, Processing Time 0.03 seconds

An Efficient Neighbor Discovery Method for Cooperative Video Surveillance Services in Internet of Vehicles (차량 인터넷에서 협업 비디오 감시 서비스를 위한 효율적인 이웃 발견 방법)

  • Park, Taekeun;Lee, Suk-Kyoon
    • Journal of Information Technology Services
    • /
    • v.15 no.4
    • /
    • pp.97-109
    • /
    • 2016
  • The rapid deployment of millions of mobile sensors and smart devices has resulted in high demand for opportunistic encounter-based networking. For the cooperative video surveillance of dashboard cameras in nearby vehicles, a fast and energy-efficient asynchronous neighbor discovery protocol is indispensable because a dashboard camera is an energy-hungry device after the vehicle's engine has turned off. In the existing asynchronous neighbor discovery protocols, all nodes always try to discover all neighbors. However, a dashboard camera needs to discover nearby dashboard cameras when an event is detected. In this paper, we propose a fast and energy-efficient asynchronous neighbor discovery protocol, which enables nodes : 1) to have different roles in neighbor discovery, 2) to discover neighbors within a search range, and 3) to report promptly the exact discovery result. The proposed protocol has two modes: periodic wake-up mode and active discovery mode. A node begins with the periodic wake-up mode to be discovered by other nodes, switches to the active discovery mode on receiving a neighbor discovery request, and returns to the periodic wake-up mode when the active discovery mode finishes. In the periodic wake-up mode, a node wakes up at multiples of number ${\alpha}$, where ${\alpha}$ is determined by the node's remaining battery power. In the active discovery mode, a node wakes up for consecutive ${\gamma}$ slots. Then, the node operating in the active discovery mode can discover all neighbors waking up at multiples of ${\beta}$ for ${\beta}{\leq}{\gamma}$ within ${\gamma}$ time slots. Since the proposed protocol assigns one half of the duty cycle to each mode, it consumes equal to or less energy than the existing protocols. A performance comparison shows that the proposed protocol outperforms the existing protocols in terms of discovery latency and energy consumption, where the frequency of neighbor discovery requests by car accidents is not constantly high.

A study on the Control Method of Single-Phase APF Using RRF Method (회전좌표계를 이용한 단상능동전력필터의 제어방법에 관한 연구)

  • 김영조;허진석;김영석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.6
    • /
    • pp.576-584
    • /
    • 2003
  • This paper presents a new control method of single-phase active power filter(APF) for the compensation of harmonic current components in nonlinear loads. Constructing a imaginary second-phase giving time delay to load currents, making single-phase system into the system that has two phases, complex calculation is possible. In the previous method, it made a imaginary-phase lagged to the load current T/4(here T is the fundamental cycle), but in proposed method, the new signal, which has the delayed phase through the filter, using the phase-delay property of low-pass filter, was used to the second phase. Instantaneous calculation of harmonic current is possible, because two phase have different phase. In this paper, it was done with instantaneous calculation using the rotating reference frames(RRF) that synchronizes with source-frequency, a reference of compensation currents, not applying to instantaneous reactive power theory which uses the existed fixed reference frames. The simulation and experiment about R-L loads using the current source were carried out, and the effect of the proposed method was preyed through the result of this experiment.

Three-Phase ZVS DC-DC Converter with Low Transformer Turn Ratio for High Step-up and High Power Applications (낮은 변압기 턴비를 갖는 고승압.대전력용 3상 ZVS DC-DC컨버터)

  • Kim, Joon-Geun;Park, Chan-Soo;Choi, Se-Wan;Park, Ga-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.242-249
    • /
    • 2011
  • The proposed converter has easy device selection for high step-up and high power applications since boost half bridge and voltage doubler cells are connected, respectively, in parallel and series in order to increase output power and voltage. Especially, optimized design of high frequency transformers is possible owing to reduced turn ratio and eliminated dc offset, and distributed power through three cores is beneficial to low profile and thermal distribution. The proposed converter does not necessitate start-up circuit and additional clamp circuit due to the use of whole duty range between 0 and 1 and is suitable for applications with wide input voltage range. Also, high efficiency can be achieved since ZVS turn on of switches are achieved in wide duty cycle range and ZCS turn on and off of diodes are achieved. The proposed converter was validated through 5 kW prototype.

Design of a High Power Three-Phase ZVS Push-Pull Converter (대전력 3상 ZVS 푸쉬풀 컨버터 설계)

  • Park, Jun-Sung;Lee, Sang-Won;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.209-218
    • /
    • 2011
  • In low voltage high current applications such as fuel cells the current-fed DC-DC converter which has small ripple current and turn ratio is more efficient. In the applications larger than 5kW the conventional single-phase current-fed converter based on full-bridge, half-bridge or push-pull topologies has high current burden of devices such as switches, and the selection and optimized design of the devices are not easy. In this paper a three-phase active-clamped current-fed push-pull DC-DC converter suitable for high power high step-up applications is proposed. The proposed converter has reduced current burden and is suitable for wide input voltage applications due to the use of whole duty cycle range. Design methods of main components including three-phase high frequency transformers are provided, and the validity and performance of the proposed converter are proved from a 5kW prototype.

New High Performance and Low Cost Construction of Unified Power System for LCD TV Backlight Driver Circuitb (LCD TV를 위한 새로운 구조의 고성능 및 저가형 Backlight 구동 전원 통합 시스템)

  • Jang, Doo-Hee;Lee, Jae-Kwang;Roh, Chung-Wook;Hong, Sung-Soo;Kim, Jin-Wook;Lee, Hyo-Bum;Han, Sang-Kyoo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.23-30
    • /
    • 2009
  • A new high performance and low cost unified power system is proposed through investigating conventional Power-Integrated Drive(PID) system and Power-Separated Drive(PSD) system applied to LCD TV. Since the proposed system consists of two stage, namely power and inverter stage it features high efficiency and cost effectiveness. To satisfy the safety standard of the High voltage transformer, 1:1 transformer is employed between inverter and high voltage transformer. Moreover, to ensure the Zero Voltage Switching(ZVS) of all power switches and the Pulse Count Modulation(PCM) method is employed, which controls the number of pulse at the fixed frequency and fixed duty cycle. Therefore, it features high efficiency, improved heat generation, cost effectiveness and good EMI performance including no additional current balancing coil. To confirm the validity of proposed system, comparison of conventional system, verification of experimental results are presented.

A Design of DLL(Delay-Locked-Loop) with Low Power & High Speed locking Algorithm (저전력과 고속 록킹 알고리즘을 갖는 DLL(Delay-Locked LooP) 설계)

  • 경영자;이광희;손상희
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.12C
    • /
    • pp.255-260
    • /
    • 2001
  • This paper describes the design of the Register Controlled DLL(Delay-Locked Loop) that achieves fast locking and low Power consumption using a new locking algorithm. A fashion for a fast locking speed is that controls the two controller in sequence. The up/down signal due to clock skew between a internal and a external clock in phase detector, first adjusts a large phase difference in coarse controller and then adjusts a small phase difference in fine controller. A way for a low power consumption is that only operates one controller at once. Moreover the proposed DLL shows better jitter performance Because using the lock indicator circuit. The proposed DLL circuit is operated from 50MHz to 200MHz by SPICE simulation. The estimated power dissipation is 15mA at 200MHz in 3.3V operation. The locking time is within 7 cycle at all of operating frequency.

  • PDF

A Study on the Fatigue Crack Propagation Behavior in F.F. Shaft Materials of Vehicle with Small Circular Defect at Variable Temperature (미소원공결함을 갖는 자동차 전류구동축재의 온도변화에 따른 피로크랙전파거동에 관한 연구)

  • Lee, S.R.;Lee, D.G.;Chung, J.K.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.6
    • /
    • pp.185-194
    • /
    • 1998
  • In this study, the rotary bending fatigue test was carried out with two kinds of material, S43C and S50C, using in the Front engine and Front drive wheels(F.F.) of vehicle. The one part of specimens was heated by high frequency induction method(about 1mm depth and $H_RC$ 56~60) and tested environment temperature were $-30^{\circ}C$, $+25^{\circ}C$ and $+80^{\circ}C$ in order to look over the influence of the heat treatment and the temperatures. In the experimented result at $+25^{\circ}C$ and $+80^{\circ}C$, the fatigue life of non-heated specimens were decreased about 35%, but that of heated specimens were decreased about only 5% at $+80^{\circ}C$ more than at $25^{\circ}C$. And in the experiment result at $-30^{\circ}C$ and $+25^{\circ}C$, the non-heated and heated specimens were about 110%, 120% higher fatigue life at $-30^{\circ}C$ than at the $+25^{\circ}C$ each other. On the other hand, the fatigue crack propagation rate of S50C was higher than that of S43C.

  • PDF

Hardware Design of High Performance ALF in HEVC Encoder for Efficient Filter Coefficient Estimation (효율적인 필터 계수 추출을 위한 HEVC 부호화기의 고성능 ALF 하드웨어 설계)

  • Shin, Seungyong;Ryoo, Kwangki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.2
    • /
    • pp.379-385
    • /
    • 2015
  • This paper proposes the hardware architecture of high performance ALF(Adaptive Loop Filter) for efficient filter coefficient estimation. In order to make the original image which has high resolution and high quality into highly compressed image effectively and also, subjective image quality into improved image, the ALF technique of HEVC performs a filtering by estimating filter coefficients using statistical characteristics of image. The proposed ALF hardware architecture is designed with a 2-step pipelined architecture for a reduction in performance cycle by analysing an operation relationship of Cholesky decomposition for the filter coefficient estimation. Also, in the operation process of the Cholesky decomposition, a square root operation is designed to reduce logic area, computation time and computation complexity by using the multiplexer, subtracter and comparator. The proposed hardware architecture is designed using Xilinx ISE 14.3 Vertex-7 XC7VCX485T FPGA device and can support 4K UHD@40fps in real time at a maximum operation frequency of 186MHz.

Estimation of Soil Moisture Content in Corn Field Using Microwave Scatterometer Data

  • Kim, Yihyun;Hong, Sukyoung;Lee, Kyoungdo;Na, Sangil;Jung, Gunho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.47 no.4
    • /
    • pp.235-241
    • /
    • 2014
  • A ground-based microwave scatterometer has an advantage for monitoring soil moisture content using multi-polarization, multi-frequencies and various incidence angles. In this paper, ground-based multi-frequency (L-, C-, and X-band) polarimetric scatterometer system capable of making observations every 10 min was used to monitor the soil moisture conditions in a corn field over an entire growth cycle. Measurements of volumetric soil moisture were obtained and their relationships to the backscatter observations were examined. Time series of soil moisture content was not corresponding with backscattering coefficient pattern over the whole growth stage, although it increased until early July (Day Of Year, DOY 160). We examined the relationship between the backscattering coefficients from each band and soil moisture content of the field. Backscattering coefficients for all bands were not correlated with soil moisture content when considered over the entire stage ($r{\leq}0.48$). However, L-band Horizontal transmit and Horizontal receive polarization (HH) had a good correlation with soil moisture ($r=0.85^{**}$) when LAI was lower than 2. Prediction equations for soil moisture were developed using the L-HH data. Relation between L-HH and soil moisture shows linear pattern and related with soil moisture content ($R^2=0.77$). Results from this study show that backscattering coefficients of microwave scatterometer appear to be effective to estimate soil moisture content in the field level.

Analysis of Adult Cardiopulmonary Resuscitation Skill Performed by Emergency Medical Technicians in Fire Department (소방 2급응급구조사의 성인 심폐소생술에 대한 숙련도 분석)

  • 최용철;이창섭;왕순주
    • Fire Science and Engineering
    • /
    • v.18 no.1
    • /
    • pp.13-17
    • /
    • 2004
  • Purpose: The purpose of this study is to predict a reasonable direction to design a pertinent educational program in the future by evaluating an adult CPR(Cardiopulmonary Resuscitation) skill performed by EMTs engaged in fire services organization and comparing the CPR success rate of factors as like a duty place and licensed year. Methods: We studied CPR skill by the use of a CPR manikin(Skillmeter Resusci Annie, Laerdal company). The study population consisted of 320 EMTs. Every EMT performed four cycle after investigating the manikin for 2 minutes. We regarded chest compression with 100 times in a minute as the 100% success rate. We analysed the skill of chest compression, ventilation and chest compression times success rate by the records printed in the CPR paper. Results: The average success rate of chest compression was 59.42$\pm$29.26% and ventilation 49.22$\pm$29.65%. The success rate of manual CPR was different between chest compression and ventilation. Also the success rate of chest compression times was high relatively as a 87.32$\pm$9.14%(p=0.000). For the CPR skill, ventilation was lowest as 49.22%. The factors such as duty place and licensed year did not influence the CPR success rate (p>0.001). Conclusion: We could have conclusion that CPR training should be shared more time in ventilation than in chest compression. Also we could reach to a conclusion that it is important to increase the times of CPR training for improving the accuracy of CPR and that the continuing education of CPR training frequency might be more than four times in a year.