• Title/Summary/Keyword: Cutoff values

Search Result 179, Processing Time 0.028 seconds

Artifactual Perfusion Defects due to the Parameters of Reconstruction Filter in Tc-99m-MIBI Myocardial SPECT Images (Tc-99m-MIBI 심근 SPECT 영상에서 재구성 필터에 의한 인위적 관류결손에 관한 연구)

  • Kwark, Cheol-Eun;Lee, Kyung-Han;Lee, Dong-Soo;Park, Yong-Woo;Chung, June-Key;Lee, Myung-Chul;Seo, Joung-Don;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.41-47
    • /
    • 1995
  • Tc-99m-MIBI(Sestamibi) myocardial SPECT along with T1-201 tomographic imaging has demonstrated wide application and high image qualify sufficient for the diagnosis of myocardial perfusion defect, which consequently reflects regional myocardial blood flow, The qualitative values of myocardial SPECT with Tc-99m-MIBI as well as the quantitative cases depend in some degree on the reconstruction techniques of multiple projections. Filtered backprojection(FBP) is the common standard for reconstruction rather than the complicated and time-consuming arithmetic methods. In FBP it Is known that the distribution of radioactivity in reconstructed transverse slices varies with the selected filter parameters such as cutoff frequencies and order(Butterworth case). The cutoff frequencies basically remove and decrease the true radioactive distribution and alter the pixel counts, which lead to underestimation of true counts in specific myocardial regions. In this study, we have investigated the effect of cutoff frequencies of reconstruction filter on the artifactually induced perfusion defects, which are often demonstrated near inferior and/or inferoseptal cardiac walls due to the intense hepatic uptake of Tc-99m-MIBI. A computerized method for identifying the relative degree of artifactual perfusion defect and for comparing those degrees along with the relative amount of hepatic uptake to myocardium was developed and patient images were studied to observe the quantitative degree of underestimation of myocardial perfusion, and to propose some reasonable thresh-old of cutoff frequency in the diagnosis of perfusion defect quantitatively. We concluded that from the quantitative viewpoint cutoff frequencies may be used as high as possible with the sacrifice of homogeneity of image quality, and those frequencies lower than the common 0.3 Nyquist frequency would reveal severe degradation of radio-active distribution near inferior and/or Inferoseptal myocardium when applying Butterworth or low pass filter.

  • PDF

Prediction of Infarction in Acute Cerebral Ischemic Stroke by Using Perfusion MR Imaging and $^{99m}Tc-HMPAO$ SPECT (급성 허혈성 뇌졸중에서 관류 자기공명영상과 99mTC-HMPAO 단광자방출단층촬영술을 이용한 뇌경색의 예측)

  • Ho Cheol Choe;Sun Joo Lee;Jae Hyoung Kim
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.55-63
    • /
    • 2002
  • Purpose : We investigated the predictive values of relative CBV measured with perfusion MR imaging, and relative CBF measured with SPECT for tissue outcome in acute ischemic stroke. Material and Methods : Thirteen patients, who had acute unilateral middle cerebral artery occlusion, underwent perfusion MR imaging, and $^{99m}Tc-HMPAO$ SPECT within 6 hours after the onset of symptoms. Lesion-to-contralateral ratios of perfusion parameters were measured, and best cut-off values of both parameter ratios with their accuracy to discriminate between regions with and without evolving infarction were calculated. Results : Mean relative CBV ratios in regions with evolving infarction and without evolving infarction were $0.58{\pm}0.27$ and $0.9{\pm}0.17$ (p < 0.001), and mean relative CBF ratios in those regions were $0.41{\pm}0.22$ and $0.71{\pm}0.14$ (p < 0.001). The best cutoff values to discriminate between regions with and without evolving infarction were estimated to be 0.80 for relative CBV ratio and 0.56 for relative CBF ratio. The sensitivity, specificity and efficiency of each cutoff value were 80.6, 87.5, 82.7% for relative CBV ratio, and 72.2, 75.0, 73.0% for relative CBF ratio (p > 0.05 between two parameters). Conclusion Measurement of relative CBV and relative CBE may be useful in predicting tissue outcome in acute ischemic stroke.

  • PDF

Diagnostic Performance of Spin-Echo Echo-Planar Imaging Magnetic Resonance Elastography in 3T System for Noninvasive Assessment of Hepatic Fibrosis

  • Se Woo Kim;Jeong Min Lee;Sungeun Park;Ijin Joo;Jeong Hee Yoon;Won Chang;Haeryoung Kim
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.180-188
    • /
    • 2022
  • Objective: To validate the performance of 3T spin-echo echo-planar imaging (SE-EPI) magnetic resonance elastography (MRE) for staging hepatic fibrosis in a large population, using surgical specimens as the reference standard. Materials and Methods: This retrospective study initially included 310 adults (155 undergoing hepatic resection and 155 undergoing donor hepatectomy) with histopathologic results from surgical liver specimens. They underwent 3T SE-EPI MRE ≤ 3 months prior to surgery. Demographic findings, underlying liver disease, and hepatic fibrosis pathologic stage according to METAVIR were recorded. Liver stiffness (LS) was measured by two radiologists, and inter-reader reproducibility was evaluated using the intraclass correlation coefficient (ICC). The mean LS of each fibrosis stage (F0-F4) was calculated in total and for each etiologic subgroup. Comparisons among subgroups were performed using the Kruskal-Wallis test and Conover post-hoc test. The cutoff values for fibrosis staging were estimated using receiver operating characteristic (ROC) curve analysis. Results: Inter-reader reproducibility was excellent (ICC, 0.98; 95% confidence interval, 0.97-0.99). The mean LS values were 1.91, 2.41, 3.24, and 5.41 kPa in F0-F1 (n = 171), F2 (n = 26), F3 (n = 38), and F4 (n = 72), respectively. The discriminating cutoff values for diagnosing ≥ F2, ≥ F3, and F4 were 2.18, 2.71, and 3.15 kPa, respectively, with the ROC curve areas of 0.97-0.98 (sensitivity 91.2%-95.9%, specificity 90.7%-99.0%). The mean LS was significantly higher in patients with cirrhosis (F4) of nonviral causes, such as primary biliary cirrhosis (9.56 kPa) and alcoholic liver disease (7.17 kPa) than in those with hepatitis B or C cirrhosis (4.28 and 4.92 kPa, respectively). There were no statistically significant differences in LS among the different etiologic subgroups in the F0-F3 stages. Conclusion: The 3T SE-EPI MRE demonstrated high interobserver reproducibility, and our criteria for staging hepatic fibrosis showed high diagnostic performance. LS was significantly higher in patients with non-viral cirrhosis than in those with viral cirrhosis.

Cutoff Values of Body Mass Index and Body Fat Measures for Metabolic Syndrome in Korean Population (한국인에서 대사증후군의 선별검사로서 체성분 분석 및 체질량지수의 타당성연구)

  • Lee, Hyun-Jae;Kim, Byoung-Gwon;Kim, Joon-Youn;Kim, Jung-Man;Yoo, Byung-Chul;Kim, Eun-Jeong;Hong, Young-Seoub
    • Journal of Life Science
    • /
    • v.20 no.1
    • /
    • pp.9-16
    • /
    • 2010
  • This study investigated cut-off values of body mass index (BMI) and body fat measures for metabolic syndrome (MS) in elderly Koreas. Questionnaire surveys, anthropometric measurements, medical examinations, and body composition analyses were conducted for 10,077 subjects aged 40-65 years in the health examinee cohort in Korea between 2004 and 2006. Cut-off values were identified using receiver-operating characteristic (ROC) curve analysis for both men and women. Stratified analyses by weight range (<60, 60-69, 70-79, and 80-89, ${\geq}90\;kg$ for men; <50, 50-59, 60-69, 70-79, ${\geq}80\;kg$ for women) were conducted. Among male subjects, the cut-off points were $25.5\;kg/m^2$ for BMI with a sensitivity of 70.0% and a specificity of 72.0%, and 26.1% for body fat percentage with a sensitivity of 60.6% and a specificity of 76.4%. Among female subjects, the cutoff points were $24.1\;kg/m^2$ for BMI with a sensitivity of 73.3% and a specificity of 68.8%, and 31.5% for body fat percentage with a sensitivity of 76.7% and a specificity of 65.6%. Stratified analysis by weight range showed that the cutoff points of BMI and body fat measures tended to higher as weight level increased. The results of our study suggest cut-off values of BMI and body fat measure for MS were similar to the general obesity criteria in Korea.

A Convergence Test of the Full-potential Linearized Augmented Plane Wave (FLAPW) Method: Ferromagnetic Bulk BCC Fe

  • Seo, Seung-Woo;Song, You-Young;Gul, Rahman;Kim, In-Gee;Weinert, M.;Freeman, A.J.
    • Journal of Magnetics
    • /
    • v.14 no.4
    • /
    • pp.137-143
    • /
    • 2009
  • The convergence behavior of the all-electron full-potential linearized augmented plane-wave (FLAPW) method with the explicit orthogonalization (XO) scheme is tested on ferromagnetic bulk body-centered-cubic Fe. Applying a commonly used criterion relating the plane-wave and angular momentum cutoffs, $l_{max}\;=\;R_{MT}K_{max}$, where $R_{MT}$ is the muffin-tin (MT) sphere radius and $K_{max}$ is the plane-wave cutoff for the basis - the total energy is converged and stable for $K_{max}R_{MT}$ = 10. The total energy convergence dependence on the star-function cutoff, $G_{max}$, is minimal and so a $G_{max}$ of 3$K_{max}$ or a large enough $G_{max}$ is a reasonable choice. We demonstrate that the convergence with respect to $l_{max}$ or a fixed large enough $G_{max}\;and\;K_{max}$ are independent, and that $K_{max}$ provides a better measure of the convergence than $R_{MT}K_{max}$. The dependence of the total energy on $R_{MT}$ is shown to be small if the core states are treated equivalently, and that the XO scheme is able to treat systems with significantly smaller $R_{MT}$ than the standard LAPW method. For converged systems, the calculated lattice parameter, bulk modulus, and magnetic moments are in excellent agreement with the experimental values.

Surgery versus Nerve Blocks for Lumbar Disc Herniation : Quantitative Analysis of Radiological Factors as a Predictor for Successful Outcomes

  • Kim, Joohyun;Hur, Junseok W.;Lee, Jang-Bo;Park, Jung Yul
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.5
    • /
    • pp.478-484
    • /
    • 2016
  • Objective : To assess the clinical and radiological factors as predictors for successful outcomes in lumbar disc herniation (LDH) treatment. Methods : Two groups of patients with single level LDH (L4-5) requiring treatment were retrospectively studied. The surgery group (SG) included 34 patients, and 30 patients who initially refused the surgery were included in the nerve blocks group (NG). A visual analogue scale (VAS) for leg and back pain and motor deficit were initially evaluated before procedures, and repeated at 1, 6, and 12 months. Radiological factors including the disc herniation length, disc herniation area, canal length-occupying ratio, and canal area-occupying ratio were measured and compared. Predicting factors of successful outcomes were determined with multivariate logistic regression analysis after the optimal cut off values were established with a receiver operating characteristic curve. Results : There was no significant demographic difference between two groups. A multivariate logistic regression analysis with radiological and clinical (12 months follow-up) data revealed that the high disc herniation length with cutoff value 6.31 mm [odds ratio (OR) 2.35; confidence interval (CI) 1.21-3.98] was a predictor of successful outcomes of leg pain relief in the SG. The low disc herniation length with cutoff value 6.23 mm (OR 0.05; CI 0.003-0.89) and high baseline VAS leg (OR 12.63; CI 1.64-97.45) were identified as predictors of successful outcomes of leg pain relief in the NG. Conclusion : The patients with the disc herniation length larger than 6.31 mm showed successful outcomes with surgery whereas the patients with the disc herniation length less than 6.23 mm showed successful outcomes with nerve block. These results could be considered as a radiological criteria in choosing optimal treatment options for LDH.

Fluorodeoxyglucose positron-emission tomography ratio in non-small cell lung cancer patients treated with definitive radiotherapy

  • Kang, Hyun-Cheol;Wu, Hong-Gyun;Yu, Tosol;Kim, Hak Jae;Paeng, Jin Chul
    • Radiation Oncology Journal
    • /
    • v.31 no.3
    • /
    • pp.111-117
    • /
    • 2013
  • Purpose: To determine whether the maximum standardized uptake value (SUV) of [$^{18}F$] fluorodeoxyglucose uptake by positron emission tomography (FDG PET) ratio of lymph node to primary tumor (mSUVR) could be a prognostic factor for node positive non-small cell lung cancer (NSCLC) patients treated with definitive radiotherapy (RT). Materials and Methods: A total of 68 NSCLC T1-4, N1-3, M0 patients underwent FDG PET before RT. Optimal cutoff values of mSUVR were chosen based on overall survival (OS). Independent prognosticators were identified by Cox regression analysis. Results: The most significant cutoff value for mSUVR was 0.9 with respect to OS. Two-year OS was 17% for patients with mSUVR > 0.9 and 49% for those with mSUVR ${\leq}0.9$ (p = 0.01). In a multivariate analysis, including age, performance status, stage, use of chemotherapy, and mSUVR, only performance status (p = 0.05) and mSUVR > 0.9 (p = 0.05) were significant predictors of OS. Two-year OS for patients with both good performance (Eastern Cooperative Oncology Group [ECOG] ${\leq}1$) and mSUVR ${\leq}0.9$ was significantly better than that for patients with either poor performance (ECOG > 1) or mSUVR > 0.9, 23% (71% vs. 23%, p = 0.04). Conclusion: Our results suggested that the mSUVR was a strong prognostic factor among patients with lymph node positive NSCLC following RT. Addition of mSUVR to performance status identifies a subgroup at highest risk for death after RT.

THE BRIGHT PART OF THE LUMINOSITY FUNCTION FOR HALO STARS

  • Lee, Sang-Gak
    • Journal of The Korean Astronomical Society
    • /
    • v.28 no.2
    • /
    • pp.139-146
    • /
    • 1995
  • The bright part of the halo luminosity function is derived from a sample of the 233 NLTT propermotion stars, which are selected by the 220 km/ see of cutoff velocity in transverse to rid the contamination by the disk stars and corrected for the stars omitted in the sample by the selection criterion. It is limited to the absolute magnitude range of $M_v=4-8$, but is based on the largest sample of halo stars up to now. This luminosity function provides a number density of $2.3{\cdot}10^{-5}pc^{-3}$ and a mass density of $2.3{\cdot}10^{-5}M_{o}pc^{-3}$ for 4 < $M_v$ < 8 in the solar neighborhood. These are not sufficient for disk stability. The kinematics of the sample stars are < U > = - 7 km/sec, < V > = - 228 km/sec, and < W > = -8 km/sec with (${\sigma_u},{\sigma_v},{\sigma_w}$) = (192, 84, 94) km/sec. The average metallicity of them is [Fe/H] = $- 1.7{\pm}0.8$. These are typical values for halo stars which are selected by the high cutoff velocity. We reanalyze the luminosity function for a sample of 57 LHS proper-motion stars. The newly derived luminosity function is consistent with the one derived from the NLTT halo stars, but gives a somewhat smaller number density for the absolute magnitude range covered by the LF from NLTT stars. The luminosity function based on the LHS stars seems to have a dip in the magnitude range corresponding to the Wielen Dip, but it also seems to have some fluctuations due to a small number of sample stars.

  • PDF

A Model for Effective Customer Classification Using LTV and Churn Probability : Application of Holistic Profit Method (고객의 이탈 가능성과 LTV를 이용한 고객등급화 모형개발에 관한 연구)

  • Lee, HoonYoung;Yang, JooHwan;Ryu, Chi Hun
    • Journal of Intelligence and Information Systems
    • /
    • v.12 no.4
    • /
    • pp.109-126
    • /
    • 2006
  • An effective customer classification has been essential for the successful customer relationship management. The typical customer rating is carried out by the proportionally allocating the customers into classes in terms of their life time values. However, since this method does not accurately reflect the homogeneity within a class along with the heterogeneity between classes, there would be many problems incurred due to the misclassification. This paper suggests a new method of rating customer using Holistic profit technique, and validates the new method using the customer data provided by an insurance company. Holistic profit is one of the methods used for deciding the cutoff score in screening the loan application. By rating customers using the proposed techniques, insurance companies could effectively perform customer relationship management and diverse marketing activities.

  • PDF

Nasal eosinophilia and eosinophil peroxidase in children and adolescents with rhinitis

  • Choi, Yeonu;Jeon, Haeun;Yang, Eun Ae;Yoon, Jong-Seo;Kim, Hyun Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.62 no.9
    • /
    • pp.353-359
    • /
    • 2019
  • Background: Researchers have shown that eosinophil peroxidase (EPO) is a relatively accurate marker of eosinophilia and eosinophil activity. However, its use as a marker of eosinophilic inflammation in nasal secretions is limited because the diagnostic cutoff values of EPO for use as a one-time test for allergic diseases such as allergic rhinitis have not been established. Purpose: To identify the correlation between nasal eosinophil count and EPO in children and adolescents with rhinitis. Methods: We recruited patients <18 years of age with rhinitis for more than 2 weeks or more than 2 episodes a year whose nasal eosinophil and EPO were measured at a single allergy clinic. The eosinophil percentage was calculated by dividing the eosinophil count by the number of total cells under light microscopy at ${\times}1,000$ magnification. EPO and protein were measured from nasal secretions. We retrospectively analyzed the correlation between nasal eosinophils and protein-corrected EPO (EPO/protein) value. Results: Of the 67 patients enrolled, 41 were male (61.2%); the mean age was $8.2{\pm}4.0years$. The median nasal eosinophil count was 1 and percentage was 1%. The median protein-corrected EPO value was $12.5ng/{\mu}g$ (range, $0-31ng/{\mu}g$). There was a statistically significant correlation between eosinophil count and percentage (P<0.001). However, the eosinophil percentage and EPO did not correlate. The eosinophil count and EPO had a statistically significant correlation (P=0.01). The EPO cutoff value examined for nasal eosinophil counts of 2, 5, 10, and 20 was $17.57ng/{\mu}g$ regardless of the reference count. The largest area under the curve value was obtained when the receiver operating characteristic curve was drawn using the eosinophil count of 2. Conclusion: Nasal eosinophil count was significantly associated with protein-corrected EPO.