• 제목/요약/키워드: Custom Wall

검색결과 22건 처리시간 0.023초

주조 포오스트의 적합도에 관한 연구 (A STUDY ON THE ADAPTATION OF THE CAST POST)

  • 박동관;장익태
    • 대한치과보철학회지
    • /
    • 제24권1호
    • /
    • pp.55-65
    • /
    • 1986
  • An in vitro study was performed to evaluate adaptation of custom direct, custom indirect, and prefabricated post system on 15 extracted upper central incisors. 15 specimens were prepared and equally devided into 3 groups under random sampling. Each group of 5 cast posts was made with custom direct, custom indirect, and prefabricated post core method. Gap between inner wall of the dentin and outer wall of the cast post was measured on electron microphotographic prints at x500 magnification. The result were as follows ; 1. No significant difference of adaptation at cervical portion was found between each method. 2. Prefabricated post core method had poor adaptation compared with other methods. 3. Even distribution of adaptation was found in custom direct method between each portion. 4. Prefabricated post core method showed remarkable difference in adaptation between each portion.

  • PDF

Curtain Wall의 특성 및 설계조건에 관한 연구 (A study on the characteristic and designing condition of Curtain wall)

  • 정을규;임칠순
    • 한국건축시공학회지
    • /
    • 제4권3호
    • /
    • pp.125-131
    • /
    • 2004
  • Nowadays, it seems we are in the high time of construction design because development of construction technology widen the option of construction exterior closing materials and deepen the high-tech construction method with all various materials. When we see the flow of construction market, the mainstream is the high-rise intelligent building, which makes the best use of the small midtown area efficently. Therefore, Alum curtain wall is becoming the main material of exterior construction, the concept of which is changing from just a simple window frame to an outer wall which has comprehensive function and capability. As we think of the importance of Curtain wall as a comprehensive outer wall, We should do thorough technical examination and verification at the stage of construction design and plan of carrying out construction.

유방전절제술 후 방사선치료를 위한 조직보상체 개발 및 3차원 치료계획을 통한 유용성 분석 (The Benefit of Individualized Custom Bolus in the Postmastectomy Radiation Therapy : Numerical Analysis with 3-D Treatment Planning)

  • 조재호;조광환;금기창;한영이;김용배;추성실;서창옥
    • Radiation Oncology Journal
    • /
    • 제21권1호
    • /
    • pp.82-93
    • /
    • 2003
  • 목적 : 유방암의 수술 후 방사선조사 시 폐나 심장 등 정상 증기에 대한 합병증을 줄이고자 흉벽에 대한 전자선 치료 시 조사야 내 전체 흉벽 두께를 균일하도록 보상할 수 있는 개별화된 조직보상체를 제작하였으며, 3차원 입체조형치료계획을 통하여 유용성을 평가하고자 하였다. 대상 및 방법 :유방전절제술 후 방사선치료를 받는 10명의 환자를 대상으로 하였다 우측 유방암 환자가 3명, 좌측유방암 환자가 7명이었다. 모든 환자는 조사야를 결정하기 위한 모의치료를 시행한 후 치료계획용 컴퓨터단층촬영을 하였으며, 이를 바탕으로 1 cm$^{2}$ 간격으로 흉벽 두께를 세밀히 측정하였다. 이후 주로 내유방림프절 근방인 가장 두꺼운 흉벽 부위를 기준으로 그 곳의 전방 흉막면에 80% 선량이 조사될 수 있는 방사선에너지를 설정하고, 이 부위를 기준으로 보다 얇은 흉벽을 보상하기 위한 개별화된 조직보상체를 제작하였으며, 제작된 조직보상체를 적용하여 다시 치료계획용 컴퓨터단층촬영을 시행하였다. 이후 각 환자의 영상자료를 이용하여 3차원 치료계획용 프로그램으로 설계하였다. 매 환자에서 조직보상체 적용 전후로 등선량곡선 분포 및 선량체적히스토그램을 비교하였고, 정상조직합병증발생률(normal tissue complication probability, NTCP)의 변화 및 기타 선량통계값도 분석 비교하였다. 결과 : 조직보상체를 적용하였을 때 모든 예에서 처방선량의 80% 등선량곡선의 깊이가 흉벽 두께와 거의 일치하였다. 조직보상체를 사용하지 않았을 때는 90% 이상의 등선량 곡선이 전방 흉막면을 지나 폐 실질 부위에 깊이 걸쳐 있는 경우가 많았으며, 특히 좌측 유방암의 경우에는 심장에도 불필요하게 높은 선량이 조사됨을 관찰할 수 있었다. 선량체적히스토그램을 조직보상체 적용 전후로 동측 폐, 반대측 폐 및 심장에 대하여 각각 비교하였는데 모든 예에서 조직보상체를 사용하였을 때 동측 폐의 선량체적히스토그램이 크게 향상된 소견을 보였으만 심장의 경우 좌측 유방암 환자에서 특히 두드러진 향상을 보였다. 동측 페의 경우 조직보상체를 적용하지 않았을 때 평균NTCP 값이 80.2${\pm}$3.43%이고, 조직보상체를 사용한 경우에는 평균 NTCP 값이 47.7${\pm}$4.61%로 개별화된 조직보상체의 사용으로 24.5~40.5%의 정상조직합병증발생률을 줄일 수 있었다. 동측 폐와 심장에 대해서 평균 선량, V$_{50}$ (처방선량 50% 이상의 선량이 조사되는 체적의 백분율), V$_{95}$ (처방선량 95% 이상의 선량이 조사되는 체적의 백분율), 최대 선량, 최소 선량 등을 구하여 보았을 때 평균 선량, V$_{50}$, V$_{95}$은 조직보상체 적용 전후에 두드러진 변화를 보였으나 최대선량 및 최소 선량값은 별다른 차이를 보이지 않았다. 결론 : 조직보상체를 적용하였을 때 적용하지 않은 경우에 비해 등선량곡선분포, 선량체적히스토그램, Lymankutcher 모델에 의한 정상조직합병증발생률 및 기타 선량통계값 등 모든 면에 있어서 우월성을 확인할 수 있었다. 향후 이러한 결과가 임상에서 실질적인 합병증 발생률 감소와 잘 연계되는지 계속적인 추적관찰 및 연구가 필요할것으로 생각된다.

Multitasking Façade: How to Combine BIPV with Passive Solar Mitigation Strategies in a High-Rise Curtain Wall System

  • Betancur, Juan
    • 국제초고층학회논문집
    • /
    • 제6권4호
    • /
    • pp.307-313
    • /
    • 2017
  • This paper outlines the processes and strategies studied and selected by the team during the design stages of the project for the incorporation of BIPV into the tower's façade. The goal was to create a system that helps reduce internal heating and cooling loads while collecting energy through photovoltaic panels located throughout the building. The process used to develop this façade system can be broken down into three stages. 1. Concept: BIPV as design catalyst for a high-rise building. 2. Optimization: Balancing BIPV and Human comfort. 3. Integration: Incorporating BIPV into a custom curtain wall design. The FKI Project clearly illustrates the evolution building enclosures from simple wall systems to high performance integrated architectural and engineering design solutions. This design process and execution of this project represent the design philosophy of our firm.

라캉의 정신분석학 개념으로 살펴 본 한국의 현대 벽화 (A Study on Contemporary Murals of Korea; in Lacan′s Psychoanalytic View)

  • 조현신
    • 디자인학연구
    • /
    • 제15권2호
    • /
    • pp.187-196
    • /
    • 2002
  • 한국의 현대 벽화는 한국의 시각적 수위를 드러내는 하나의 지표이다. 본 논문의 첫째 장에서는 한국의 현대 벽화제작 시스템을 분석한 후, 둘째 장에서는 조선시대의 풍속화나 시각상징물을 재현한 벽화를 라캉의 정신분석학적 개념을 빌어 설명했다. 라캉의 연구 중 주종을 이루는 상상계와 상징계의 개념으로 한국적인 소재 재현의 심리적, 정신적 배경을 분석하는 방법을 취했다. 한국의 벽화가 보여주는 시각 현실은 과거조선 시대 공동체와의 상상적 동일시를 피하는 것이라는 논지로 전개되었으며, 이는 서구 중심의 상징계에서 생활하는 주체의 분열상, 허구적 의식을 암시하는 동시에 주체의 시지각에 혼란을 초래하는 요인이 되어 또 다시 상상계적 재현을 되풀이하는 것으로 결론지었다. 결론에서는 이러한 시각 혼란 현상을 극복하고 실재 생활을 표현하는 시각 양식의 개발을 위해서 한국인의 아비투스를 연구해서 그에 맞는 대안이 마련되어야 한다는 후속 연구의 방향을 제시하였다.

  • PDF

Dependencies of Ultrasonic Velocities on the Wall Thickness in Polyvinyl Chloride Cortical Bone Mimics

  • Lee, Kang-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • 제29권3E호
    • /
    • pp.140-145
    • /
    • 2010
  • In the present study, tubular polyvinyl chloride (PVC) cortical bone mimics that simulate the cortical shell of long bones were used to validate the axial transmission technique for assessing the cortical thickness by measuring the ultrasonic velocities along the cortical shell of long bones. The ultrasonic velocities in the 9 PVC cortical bone mimics with wall thicknesses from 4.0 to 16.1 mm and inner diameters from 40 to 300 mm were measured as a function of the thickness by using a pair of custom-made transducers with a diameter of 12.7 mm and a center frequency of 200 kHz. In order to clarify the measured behavior, they were also compared with the predictions from a theory of guided waves in thin plates. This phantom study using the PVC cortical bone mimics provides useful insight into the dependencies of ultrasonic velocities on the cortical thickness in human long bones.

변화하는 혈압의 영향을 받지 않는 동맥 벽의 강화도 측정 방법 제안 : 대동맥 확장지수 (A suggestion of Aortic wall Stiffness Evaluation Technique Independent on Changeable Blood Pressure : Aortic Distensibility Index)

  • 서지혜;최동호;오수경;;이종민
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권2호
    • /
    • pp.151-158
    • /
    • 2008
  • To evaluate aortic wall stiffness without influence of different background blood pressure, a new technique was developed and verified. At eight swine descending aortae, volume-pressure measurement was performed using custom-made system. Based on averaged pressure-volume curve, aortic distensibility index was formulated to evaluate aortic wall stiffness regardless of variable blood pressure and aortic size. The variability of aortic distensibility index by pressure change was compared with other parameters for wall stiffness evaluation. Subsequently, the aortic distensibility index was calculated at 100 contrast-enhanced EBCT data sets of normal volunteers in regular health screening program. The measured aortic distensibility index was compared with age, coronary calcium score, and aortic calcium score. Between 50 and 360 mmHg of blood pressure, the coefficient of variance of aortic distensibility index was 22.00% as comparing with 88.99% of classical compliance. Based on age, aortic distensibility index showed correlation coefficient of 0.55, whereas classical compliance showed 0.26. The correlation coefficient with modified aortic calcification was 0.43. Linear regression study revealed statistical significance of correlation coefficients. The aortic distensibility index, the method to evaluate aortic wall stiffness free from variable blood pressure and aortic size, was developed and verified with significant practical feasibility.

맞춤형 커튼월 패널의 꼭짓점 좌표데이터 전이를 통한 BIM 형태 구축 프로세스 모델 연구 - 라이노에서 레빗으로의 좌표데이터 전이를 중심으로 - (A Study on BIM Implementation Process Model through Importing Vertex Coordinate Data for Customized Curtain Wall Panel - Focusing on importing Vertex Coordinate data to Revit from Rhino -)

  • 고성학
    • 대한건축학회논문집:계획계
    • /
    • 제35권11호
    • /
    • pp.69-78
    • /
    • 2019
  • The purpose of this study is to propose a modeling methodology through the exchange of coordinate data of a three-dimensional custom curtain wall panel between Rhino and Revit, and to examine the validity of the model implemented in the drawing. Although the modeling means and method are different, a fundamental principle is that all three-dimensional modeling begins by defining the position of the points, the most primitive element of geometry, in the XYZ coordinate space. For the BIM modeling methodology proposal based on this geometry basic concept, the functions and characteristics associated with the points of Rhino and Revit programs are identified, and then BIM implementation process model is organized and systemized through the setting of the interoperability process algorithm. The BIM implementation process model proposed in this study is (1) Modeling and panelizing surface into individual panels using Rhino and Grasshopper; (2) Extraction of vertex coordinate data from individual panels and create CSV file; (3) Curtain wall modeling through Adaptive Component Family in Revit and (4) Automatic creation of Revit curtain wall panels through API. The proposed process model is expected to help reduce design errors and improve component and construction quality by automatically converting general elements into architectural meaningful information, automating a set of processes that build them into BIM data, and enabling consistent and integrated design management.

Experimental investigation of earth pressure on retaining wall and ground settlement subjected to tunneling in confined space

  • Jinyuan Wang;Wenjun Li;Rui Rui;Yuxin Zhai;Qing He
    • Geomechanics and Engineering
    • /
    • 제32권2호
    • /
    • pp.179-191
    • /
    • 2023
  • To study the influences of tunneling on the earth pressure and ground settlement when the tunnel passes through the adjacent underground retaining structure, 30 two-dimensional model tests were carried out taking into account the ratios of tunnel excavation depth (H) to lateral width (w), excavation width (B), and excavation distance using a custom-made test device and an analogical soil. Tunnel crossing adjacent existing retaining structure (TCE) and tunnel crossing adjacent newly-built retaining structure (TCN) were simulated and the earth pressure variations and ground settlement distribution during excavation were analyzed. For TCE condition, the earth pressure increments, maximum ground settlement and the curvature of the ground settlement curve are negatively related to H/B, but positively related to H/s and H/w. For TCN condition, most trends are consistent with TCE except that the earth pressure increments and the curvature of ground settlement curve are negatively related to H/w. The maximum ground settlement is larger than that observed in tunnel crossing the existing underground structure. This study provides an assessment basis for the design and construction under confined space conditions.

An in-vitro evaluation of sealer placement methods in simulated root canal extensions

  • Kim, Sung-Young;Lee, Se-Jun;Lee, Kwang-Won
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.579-579
    • /
    • 2003
  • I. Objectives The aim of this study was to evaluate and compare the effectiveness of sealer placement in simulated root canal extensions using the K file, ultrasonic file, lentulo spiral and EZ-Fill. II. Materials and Methods Forty resin blocks were attained from cutting Endo-training Bloc with diamond saw. In each parallelepiped block, the simulated root canal was made with #20, 08taper GT file. After each block was longitudinally split into two halves using mallet and chisel, a standardized groove of 4mm in length, located 2mmapart from the root apex, was prepared on one wall of two halves using the custom-made knife to simulate the canal extensions with various irregularities.(omitted)

  • PDF