• 제목/요약/키워드: Curtain plate

검색결과 14건 처리시간 0.019초

폭발강화격벽의 초기구조설계에 관한 연구 (제2보 : 커튼판 방식 폭발강화격벽의 설계식 개발) (Preliminary Structural Design of Blast Hardened Bulkhead (The 2nd Report : Scantling Formula for Curtain Plate Type Blast Hardened Bulkhead))

  • 노인식;박만재;조윤식
    • 대한조선학회논문집
    • /
    • 제55권5호
    • /
    • pp.379-384
    • /
    • 2018
  • This study showed the development process of structural design method of BHB(Blast Hardened Bulkhead) which are applicable in preliminary design stage. In the previous 1st report, the simplified structural scantling equations of BHB were formulated theoretically using the modified plastic hinge method supplemented by considering the membrane effects due to large plastic deformation. And the scantling methodology of plate thickness and section area of stiffeners of the curtain plate type BHB was dealt with. In the present 2nd report, derivation process of the correction factors which can adjust the developed scantling equations considering the uncertainties contained in the design parameters was introduced. Considering the actual BHB structures of 3 warship, the correction factors for the developed scantling equations for curtain plate type BHB were derived. Finally the applicability, validity of them and the strategy of future improvement were considered.

Evaluation of a Curtain-Type Radiation Protection Device for Veterinary Interventional Procedures

  • Minsik Choi;Jaepung Han;Changgyu Lim;Jiwoon Park;Sojin Kim;Uhjin Kim;Jinhwa Chang;Dongwoo Chang;Namsoon Lee
    • 한국임상수의학회지
    • /
    • 제41권3호
    • /
    • pp.157-164
    • /
    • 2024
  • The standard radiation protection method in the angiography suite involves the use of a thyroid shield, a lead apron, and lead glasses. However, exposure to substantial amounts of ionizing radiation can cause cataracts, tumors, and skin erythema. A newly developed curtain-type radiation protection device consists of a curtain drape composed of a five-layer bismuth and lead acrylic head-shielding plate, with both bearing an equivalent 0.25 mm lead thickness. In this study, a quality assurance phantom was used as the patient to create radiation scatter from the radiographic source, and an anthropomorphic mannequin phantom was used as the interventionalist to measure the radiation dose at seven different anatomical locations. Thermoluminescent dosimeters were used to measure the radiation dose. The experimental groups consisted of all-sided or one-sided curtain set-ups, the presence or absence of a conventional shielding system, and the orientation of beam irradiation. Consequently, the curtain-type radiation protection device exhibited better radiation protection range and capabilities than conventional radiation protection systems, especially in safeguarding the forehead, eyes, arms, and feet, with minimal radiation exposure. Moreover, the mean shielding ratios of the conventional shielding system and curtain-type radiation protection device were measured at 51.94% and 93.86%, respectively. Additionally, no significant decrease in the radiation protection range or capability was observed, even with changes in the beam orientation or one-sided protection. Compared with a conventional shielding system, the curtain-type radiation protection device decreased radiation exposure doses and improved comfort. Therefore, it is a potential new radiation protection device for veterinary interventional procedures.

유도공기 및 에어커튼을 이용한 주방 레인지후드 성능 개선에 관한 수치모사 (A Numerical Study on the Performance Improvement of Kitchen Range Hood by Air Induction and Air Curtain)

  • 손덕영;임지홍;최윤호;박재훈
    • 설비공학논문집
    • /
    • 제19권4호
    • /
    • pp.321-327
    • /
    • 2007
  • In an apartment house that is generally air-tight and well insulated, the combustion gas from cooking devices is the major source of air pollution in the kitchen. It spreads throughout the house affecting the overall Indoor all quality. In this study, the performance of the kitchen range hood which employs air induction and air curtain was investigated by numerical simulation. The results are compared with that of two other kitchen range hoods which are in general use. The two general types of range hoods considered in the present calculations are box and plate type range hoods. The former has a large capture space between the filter and suction duct, while the latter has little. It was found that the capture efficiency of the kitchen range hood with air induction and air curtain Is higher than that of the general types of range hoods by 20% approximately The reason may be because the air induction and the air curtain block the air stream escaping from the front and the side part of range hoods effectively and because an additional fan for air induction and air curtain increases suction flow rates.

충격량에 대한 응답을 고려한 폭발강화격벽 설계 방법 연구 (A Study on Design Method of Blast Hardened Bulkhead Considering the Response of Shock Impulse)

  • 곽묘정;윤준영;권승민;노유정
    • 대한조선학회논문집
    • /
    • 제60권1호
    • /
    • pp.10-19
    • /
    • 2023
  • Blast Hardened Bulkhead (BHB) is an important measure that can increase the ship's survivability as well as protect the lives of the crew by mitigating the damage extent caused by an internal explosion in the ship. In particular, both the pressure and the shock impulse should be considered when designing the BHB against reflected shock waves having a high pressure with a short duration. This study proposes a design method for BHB that considers both the pressure and the shock impulse generated during the internal explosion. In addition, analysis and design concepts for accident loads such as explosion, fire, and collision of NORSOK and DNVGL, one of the international design guidelines for the curtain plate type blast hardened bulkhead type applied by the Korean Navy, are utilized. If this method is applied, it is expected that it can be used as a design concept for the pressure as well as the shock impulse of the explosion load of the curtain plate.

공동주택 발코니의 열환경 향상방안 (Improving the Thermal Environment of Balcony in Apartment House)

  • 박선효;배상환;홍천화
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2003년도 정기총회 및 추계학술대회
    • /
    • pp.41-46
    • /
    • 2003
  • In recent days, it is usual case to extend the dwelling area to the balcony which is provided by service area. But the use of the extended area can be arisen discomfort with a view point of thermal environment by excessive heat accumulation in summer and excessive cold draft in winter. In this study, the skills were reviewed to improve the thermal environment of the extended area and evaluations were carried out. Additional heat supply by heat-convector installed at the lower end of the curtain wall can improve the thermal environment of the extended area and also arise surface temperature of the curtain wall surface. And aluminum plate installed under the floor could not improve the thermal environment but it was effective to shortening the initial heating time.

  • PDF

기포층 음향 삽입손실 연구: 기포커튼과 에어마스커 (Acoustic insertion loss by a bubble layer for the application to air bubble curtain and air masker)

  • 박철수;정소원;김건도;문일성;임근태
    • 한국음향학회지
    • /
    • 제39권4호
    • /
    • pp.227-236
    • /
    • 2020
  • 해양구조물의 파일링 소음을 줄이기 위한 기포커튼과 선체 진동에 의한 수중방사소음 차단을 위한 에어마스커에 대하여 각각의 삽입손실 해석해를 유도하였다. 해석해를 구하기 위해 기포커튼과 에어마스커를 각각 '유체-기포층-유체' 그리고 '진공-평판-유체-기포층-유체'의 단순 모델로 가정하였고, 각 모델에서 해당 기포층을 복소수 형태의 파수와 임피던스로 규정된 유효매질로 치환하였다. 수치 모의를 통해 기포의 분포, 기포율, 그리고 기포층의 두께에 따른 삽입손실의 특성을 살펴보았다.

배플판 형상이 다른 Gun식 가스버너의 난류유동 특성치 고찰 (Investigation on the Turbulent Flow Characteristics of a Gun-Type Gas Burner with the Different Shape of Baffle Plate)

  • 김장권;정규조
    • 대한기계학회논문집B
    • /
    • 제28권4호
    • /
    • pp.475-485
    • /
    • 2004
  • This paper was studied to investigate and compare the effects of inclined baffle plate on the turbulent flow characteristics of a gun-type gas burner through X-Y plane and Y-Z plane respectively by using X-probe from hot-wire anemometer system. For this purpose, two burner models with a cone-type baffle plate and a flat-type one respectively were used. The fast jet flow spurted from slits plays a role such as an air-curtain because it encircles rotational flow by swirl vanes and drives mixed main flow to axial direction regardless of the inclination of baffle plate. The inclined baffle plate causes axial mean velocity component and turbulent intensities etc. to be greatly concentrated towards the central part of a burner, and its effect especially appears in the range of about X/R=1.0-2.0. Also, it gives much larger size to axial mean velocity component and turbulent intensities etc formed near the slits in the range of X/R=1.4103. Especially the inclined baffle plate shifts more the Reynolds shear stress uw to the central region of a burner(Y/R=${\pm}$0.75) than the flat-type one, moreover it develops more strongly than uv.

국내 일반 한우농가와 유기 한우농가 사육시설 비교 (Comparison of Conventional and Organic Cattle (Hanwoo) Farm System)

  • 천시내;이준엽;양승학;박규현;전중환
    • 한국축산시설환경학회지
    • /
    • 제20권4호
    • /
    • pp.161-166
    • /
    • 2014
  • We conducted investigations of the information and welfare of cattle in Korea. The livestock housing of conventional cattle farms and organic cattle farms were open side wall type with winch curtain and used litter floor. The stocking density of conventional (ranging from $10head/m^2$ to $12.5head/m^2$) and organic cattle farms (ranging from $10head/m^2$ to $16.7head/m^2$) met the demand for conventional or organic standards, respectively. The galvanized plate and sunlight plate were used as the roof material in all of farms. Especially, additional areas were provided to produce forage or to improve animal welfare in organic cattle farms. Thus we believe that present data contribute to develop the animal welfare certification for cattle and to improve animal welfare in Korea.

보행하중을 받는 건축물 바닥판의 진동해석 (Vibration Analysis of Building Floor Subjected to Walking Loads)

  • 김기철;이동근
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.414-421
    • /
    • 2001
  • Recently, the damping effect of building structures are greatly reduced because the use of non-structures members as like curtain wall are decreased and large open space are in need for the service of buildings. Assembly and office buildings with a lower natural frequency have a higher possibility of experiencing excessive vibration induced by human activities as like jumping, running and walking. These excessive vibration make the occupants uncomfortable and the serviceability deterioration. The common method of application of walking loads for the vibration analysis of structures subjected to walking loads is to inflict a series unit walking load and a periodic function at a node. But this method could not consider the moving effect of walking. In this study, natural frequency and damping ratio of plate structure are evaluated by heel drop tests. And new application of equivalent walking loads are introduced for vibration analysis of real slab system subjected to walking loads. The response obtained from the numerical analysis are compared well to the results measured by experimental tests. It is possible to efficiently analyze the vibration of floor which is subjected to walking loads by applying equivalent walking loads.

  • PDF

강변여과수를 이용한 온실난방기술 개발 (Greenhouse Heating Technology Development by using Riverbank Filtration Water)

  • 문종필;이성현;권진경;강연구;유영선;이수장
    • 한국농공학회논문집
    • /
    • 제53권6호
    • /
    • pp.145-152
    • /
    • 2011
  • In order to heat greenhouse nearby river channel, riverbank filtration water source heat pump was developed for getting plenty of heat flux from geothermal energy. Recharging well, thermal storage tank with separating insulation plate and filtering tank for eliminating iron, manganese were mainly developed for making the coefficient of performance (COP) of heat pump higher. Heating system using riverbank filtration water source heat pump was installed at a paprika greenhouse in the Jinju region where a single fold of vinyl cover and 2 layers of horizontal thermal curtain were installed as a part of temperature keeping and heat insulation with a greenhouse area of 3,185 $m^2$. 320,000 kcal/h was supplied for performing a site application tests. A greenhouse heating test was performed from Feb. 1, 2011 to Apr. 30, 2011. As the result of that, COPh of the heat pump was measured in the range of 4.0~4.5, while COPS of the system was represented as 2.9~3.3. COP measured of the heat pump was very good and well responded to indoor heating temperature of the environment control system of a greenhouse.