• Title/Summary/Keyword: Current supplies

Search Result 314, Processing Time 0.036 seconds

Modeling and Control Method for High-power Electromagnetic Transmitter Power Supplies

  • Yu, Fei;Zhang, Yi-Ming
    • Journal of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.679-691
    • /
    • 2013
  • High-power electromagnetic transmitter power supplies are an important part of deep geophysical exploration equipment. This is especially true in complex environments, where the ability to produce a highly accurate and stable output and safety through redundancy have become the key issues in the design of high-power electromagnetic transmitter power supplies. To solve these issues, a high-frequency switching power cascade based emission power supply is designed. By combining the circuit averaged model and the equivalent controlled source method, a modular mathematical model is established with the on-state loss and transformer induction loss being taken into account. A triple-loop control including an inner current loop, an outer voltage loop and a load current forward feedback, and a digitalized voltage/current sharing control method are proposed for the realization of the rapid, stable and highly accurate output of the system. By using a new algorithm referred to as GAPSO, which integrates a genetic algorithm and a particle swarm algorithm, the parameters of the controller are tuned. A multi-module cascade helps to achieve system redundancy. A simulation analysis of the open-loop system proves the accuracy of the established system and provides a better reflection of the characteristics of the power supply. A parameter tuning simulation proves the effectiveness of the GAPSO algorithm. A closed-loop simulation of the system and field geological exploration experiments demonstrate the effectiveness of the control method. This ensures both the system's excellent stability and the output's accuracy. It also ensures the accuracy of the established mathematical model as well as its ability to meet the requirements of practical field deep exploration.

Development of Magnet Power Supply using Half Bridge Push Pull DC/DC Converter (하프 브릿지 푸쉬 풀 DC/DC 컨버트를 이용한 전자석 전원 개발)

  • Kim, S.C.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2030-2032
    • /
    • 1998
  • It is always necessary to high performance power supplies for the magnet system in the accelerator, especially when the number of power supplies are large. When have developed the compact power supply using switching technology instead of SCR phase control. We adopt the pulse width modulation(PWM) method with a half bridge DC/DC converter. In this way, we can make a compact system with light weight and small volume. Actual system we developed is 1.2kW, 35V/35A bipolar DC power supply current precision of +/-0.02%. It is possible to mount 10 unit in a conventional 19 rack. The built in controller has an RS422 protocol to drive 10 unit by one serial port up to 1.2km distance. If we adopt RS485 protocol, one serial port can control 32 power supplies. In this paper, we will report the design and performance of the prototype power supply.

  • PDF

A Baseline Study on Quality Improvement Strategy for Appropriate Management of Medical Supplies and Goods at General Hospitals in Korea (우리 나라 종합병원 진료재료 구매와 재고관리 질 향상 방안에 관한 연구)

  • Lee, Yeon-Hee;Yoon, Seok-Jun
    • Quality Improvement in Health Care
    • /
    • v.9 no.1
    • /
    • pp.6-17
    • /
    • 2002
  • Background : This study was conducted to investigate the current situation of medical supply purchasing and stock management at general hospitals having more than 150 beds in Korea and to find methods of effective purchasing and optimal stock management. Methods : Survey was done from staff at the purchasing departments of 229 general hospitals throughout Korea. Data collection was done using a structured questionnaire between January 3 to March 15, 2001. The survey form was returned from 88 hospitals (rate of return: 38.4%). Results : Firstly, 13.6% of the hospitals did not carry the optimal stock of medical supplies, the lead time optimal stock was 3 weeks or longer in 64.4% of the hospitals. Secondly, since 69.8% of the hospitals showed passive attitude toward training on purchasing management and stock management techniques. Thirdly, as for the question on the presence or absence of a deliberation committee for purchasing of new medical supplies, 60% of the hospitals with less than 300 beds did not have one, and 9.4% of the hospitals opened the deliberation committee less than twice a year. Conclusion : At the time of purchasing new medical supplies, purchasing should be done according to the decision by the deliberation committee so that no deduction is made at the time of claiming insurance, and by setting a certain period of time, purchasing of those medical supplies that were not purchased during this period needs to be done according to the decision by the deliberation committee.

  • PDF

Comparative analysis of power factor correction circuit using Feedforward (Feedforward제어 방식을 이용한 역률개선회로의 비교분석)

  • Kim, Cherl-Jin;Jang, Jun-Young;Yoo, Byeong-Kyu;Lee, Dal-Eun;Baek, Soo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.187-189
    • /
    • 2003
  • Conventional Switched Mode Power Supplies(SMPS) with diode-capacitor rectifier have distorted input current waveform with high harmonic content. Typically, these SMPS have a power factor lower than 0,65. To improve with this problem the power factor correction(PFC) circuit of power supplies has to be introduced. Specially. to the reduce size and manufacture cost of power conversion device, the single-stage PFC converter is increased to demand as necessary of study. in this paper, The comparative analysis of power factor correction circuit using Feedforward control with average current mode flyback converter(single-stage) and boost converter(two-stage). Also, the validity of designed and manufactured high power factor flyback converter and boost converter is confirmed by simulation and experimental results.

  • PDF

A Study about The Hot-Swap Function for Prevention of Trouble in PLC Power Supplies (PLC 전원공급장치의 고장 방지를 위한 HOT-SWAP 기술에 관한 연구)

  • Park, Jong-Jin;Lee, Jong-Jae;Kwon, Bong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.237-239
    • /
    • 2005
  • In this paper PLC Power Circuit with Hot-Swap Function is proposed for stable power supplies. The power modules of the proposed devices are implemented by CRM flyback converter using new synchronous rectifier circuit for high efficiency. By a variable switching frequency controller, this converter is operated with a reduced turn-on switching loss. Also, the load current in these power modules are shared by auto master / slave method using Outer loop. The proposed devices are analyzed in detail and optimized for high performance. Experimental results for a 100W power module at the variable switching frequency of 30$^{\sim}$70kHz were obtained to show the performance of the proposed device.

  • PDF

The behavior of the early stage of the spark kernel growth at constant pressure surroundings (전기 점화 방식에 있어서 초기 점화핵(Spark kernel) 성장의 정압특성)

  • 김현우;정인석;조경국
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.12 no.4
    • /
    • pp.75-82
    • /
    • 1990
  • To study on the behavior of the early stage of the spark kernel at constant pressure condition, the expressions of the thermal properties such as compressibility factor, thermal conductivity, and electrical conductivity of the high temperature air were newly suggested. The newly suggested simple expressions of the thermal properties of the high temperature air showed good results. Under the assumption of constant pressure, one dimensional numerical analysis was executed by varying surrounding conditions and discharging current of electrical spark. Numerical results show tat high surrounding pressure suppresses the growth of the spark kernel but supplies much electrical energy into the air, on the other hand high surrounding temperature increases the growth of the spark kernel but supplies less electrical energy. Also the result shows that , in case of direct current discharge, deposited electrical energy is able to be expressed in linear function of time approximately.

  • PDF

Two-stage & Single-stage Power Factor Correction circuits for Single-phase Power source (단상전원에 적합한 단일단 및 2단 역률개선회로)

  • Kim Chert-Jin;Yoo Byeong-Kyu;Kim Choong-Sik;Kim Young-Tae
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1214-1216
    • /
    • 2004
  • Conventional Switched Mode Power Supplies(SMPS) with diode-capacitor rectifier have distorted input current waveform with high harmonic contents. Typically, these SMPS have a power factor lower than 0,65. To improve with this problem the power factor correction(PFC) circuit of power supplies has to be introduced. PFC circuit have tendency to be applied in new power supply designs. The input active power factor correction circuits can be implemented using either the two-stage or the single-stage approach. In this paper, the comparative analysis of power factor correction circuit using feedforward control with average current mode single-stage flyback method converter and two-stage converter which is combination of boost and flyback converter. The two prototypes of 50W were designed and tested a laboratory experimental. Also, the comparative analysis is confirmed by simulation and experimental results.

  • PDF

Precision Current Measurement of Magnet Power Supply at the PLS-II (포항가속기연구소 전자석전원장치 출력 전류 정밀 측정)

  • Kim, Sung-chul;An, Suk-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.67-68
    • /
    • 2016
  • The accurate measurement of magnet power supplies (MPS) output currents is essential to delivering stable and repeatable currents to magnets in particle accelerators. An essential element in guaranteeing and evaluating the required performance is the current measurement device and methode. In this paper, we discuss instrument and methods for precision current measurement and performance of the PLS-II MPS.

  • PDF

Suggestion for Proper Quality Assurance Type Classification Criteria of Military Supplies (군수품의 적정 품질보증형태 분류를 위한 제언)

  • Ahn, Nam-Su;Kim, Sung-Gon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.648-654
    • /
    • 2018
  • Currently, the Defense Agency for Technology and Quality (DTaQ), which is responsible for the quality assurance of military supplies, divides munitions into four categories, in order to conduct its governmental quality assurance activities, including product examination, process review and system audit. However, these 4 categories may differ depending on the related organizations' (e.g. Defense Acquisition Program Administration, munitions manufacturing) military requirements. Therefore, in this study, appropriate classification criteria for munitions are suggested for the sake of the efficient procurement, production and quality assurance of military supplies. We investigated the item classification system of the Public Procurement Service, which is a similar organization to the DTaQ. We also compared the appropriate classification criteria with those of related organizations and identified the current status of munitions classification data according to the current standard. In addition, application samples are presented using the proposed quality assurance classification criteria. Finally, the classification criteria of military supplies proposed in this paper will contribute to improving the efficiency of government quality assurance activities.

An Objective Method of Risk Assessment Based on Stochastic Modelling (확률 기반의 위험등급평가 객관화 방안)

  • Shin, Sang-Sik;Lee, Kil-Soo;Cho, Heung-Gi
    • Journal of Korean Society for Quality Management
    • /
    • v.41 no.3
    • /
    • pp.465-474
    • /
    • 2013
  • Purpose: To provide a variety of stable military supplies, risk should be avoided or removed. This paper aims to provide an objective method of risk assesment for risk matrix to evaluate risk level. Methods: According to previous results of risk assesment through risk matrix, some parameters and probability density functions, which include characteristics of military supplies, are selected and Risk matrix is modelled based on that. Results: Results show that a proposed method can evaluate objectively risk level through the stochastic modelling and provide well-balanced risk assessments by categorizing into 3 levels such as high, middle and low level risk. Conclusion: A current risk assessment method includes substantial subjectivity of risk assessment and as a problem about military supplies comes up, we can not show any appropriate evidences for decision of risk assessment. We propose an objective scheme employing stochastic modelling with parameters and probability density functions.