Two-stage & Single-stage Power Factor Correction circuits for Single-phase Power source

단상전원에 적합한 단일단 및 2단 역률개선회로

  • Published : 2004.07.14

Abstract

Conventional Switched Mode Power Supplies(SMPS) with diode-capacitor rectifier have distorted input current waveform with high harmonic contents. Typically, these SMPS have a power factor lower than 0,65. To improve with this problem the power factor correction(PFC) circuit of power supplies has to be introduced. PFC circuit have tendency to be applied in new power supply designs. The input active power factor correction circuits can be implemented using either the two-stage or the single-stage approach. In this paper, the comparative analysis of power factor correction circuit using feedforward control with average current mode single-stage flyback method converter and two-stage converter which is combination of boost and flyback converter. The two prototypes of 50W were designed and tested a laboratory experimental. Also, the comparative analysis is confirmed by simulation and experimental results.

Keywords