• 제목/요약/키워드: Current limiting operation

검색결과 142건 처리시간 0.027초

IGBT full-bridge dc-dc 변환기를 이용한 전동지게차의 주행제어 시스템 개발 (A Design of the drive speed control system using IGBT full-bridge dc-dc converter for the battery fork-lift truck.)

  • 전순용;박성기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1176-1178
    • /
    • 1992
  • This paper shows enhanced working performance of the battery fork-lift truck by developing the IGBT full bridge dc-dc convertor using one-chip micro-processor. The PWM pulse is generated from a 16 bit one-chip micro-processor for the speed control of DC motor. In order to ensure the operation of IGBT and motor pecewisely, IGBT gate drive circuit was designed by using current limiting IC and hige voltage limit IC. And also It is able to regenerative braking.

  • PDF

Markov Chain을 이용한 철도계통의 고조파 분석 (Harmonics Analysis of Railroad Systems using Markov Chain)

  • 송학선;이승혁;김진오;김형철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.230-233
    • /
    • 2005
  • This paper proposes power qualify assessment using Markov Chain applied to Ergodic theorem. The Ergodic theorem introduces the state of aperiodic, recurrent, and non-null. The proposed method using Markov Chain presents very well generated harmonic characteristics according to the traction's operation of electric railway system. In case of infinite iteration, the characteristic of Markov Chain that converges on limiting probability Is able to expected harmonic currents posterior transient state. TDD(Total Demand Distortion) is also analyzed in expected current of each harmonic. The TDD for power quality assesment is calculated using Markov Chain theory in the Inceon international airport IAT power system.

  • PDF

발전소 공기예열기 소재의 배기가스 농도 및 온도에 따른 내식성 및 노점 분석 (Analysis of Corrosion Resistance and Dew Point with Exhaust Gas Concentration and Temperature for Air Preheater Materials in Power Plants)

  • 이승준
    • Corrosion Science and Technology
    • /
    • 제22권5호
    • /
    • pp.351-358
    • /
    • 2023
  • Although many thermal power plants use heat recovery systems, high exhaust gas temperatures are maintained due to corrosion at dew points and ash deposits caused by condensate formation. The dew point of exhaust gas is primarily determined by the concentration of SO3 and steam, and various experiments and calculation equations have been employed to estimate it. However, these methods are known to be less suitable for exhaust gases with low SO3 concentrations. Therefore, in this study, since the temperature of the exhaust gas is expected to decrease due to the low-load operation of the coal-fired power plant, sulfuric acid condensation and low-temperature corrosion are anticipated. We aimed to conduct a quantitative evaluation to propose ways to prevent damage by limiting operating conditions and improving facilities. The experimental results showed that the corrosion rate increased linearly with rising temperatures at a certain sulfuric acid concentration. Furthermore, variations in sulfuric acid concentrations generated during the current power plant operation process did not significantly affect the dew point, and the dew point of sulfuric acid under these conditions was observed to be between 120 - 130 ℃.

Electricity Generation by Microbial Fuel Cell Using Microorganisms as Catalyst in Cathode

  • Jang, Jae Kyung;Kan, Jinjun;Bretschger, Orianna;Gorby, Yuri A.;Hsu, Lewis;Kim, Byung Hong;Nealson, Kenneth H.
    • Journal of Microbiology and Biotechnology
    • /
    • 제23권12호
    • /
    • pp.1765-1773
    • /
    • 2013
  • The cathode reaction is one of the most seriously limiting factors in a microbial fuel cell (MFC). The critical dissolved oxygen (DO) concentration of a platinum-loaded graphite electrode was reported as 2.2 mg/l, about 10-fold higher than an aerobic bacterium. A series of MFCs were run with the cathode compartment inoculated with activated sludge (biotic) or not (abiotic) on platinum-loaded or bare graphite electrodes. At the beginning of the operation, the current values from MFCs with a biocathode and abiotic cathode were $2.3{\pm}0.1$ and $2.6{\pm}0.2mA$, respectively, at the air-saturated water supply in the cathode. The current from MFCs with an abiotic cathode did not change, but that of MFCs with a biotic cathode increased to 3.0 mA after 8 weeks. The coulomb efficiency was 59.6% in the MFCs with a biotic cathode, much higher than the value of 15.6% of the abiotic cathode. When the DO supply was reduced, the current from MFCs with an abiotic cathode decreased more sharply than in those with a biotic cathode. When the respiratory inhibitor azide was added to the catholyte, the current decreased in MFCs with a biotic cathode but did not change in MFCs with an abiotic cathode. The power density was higher in MFCs with a biotic cathode ($430W/m^3$ cathode compartment) than the abiotic cathode MFC ($257W/m^3$ cathode compartment). Electron microscopic observation revealed nanowire structures in biofilms that developed on both the anode and on the biocathode. These results show that an electron-consuming bacterial consortium can be used as a cathode catalyst to improve the cathode reaction.

변압기 중성점 접지리액터 과열원인분석 및 해소방안에 관한 연구 (A study on the cause Analysis and solution of an overheated NGR of the Main Transformer)

  • 박길수;박수홍
    • 한국전자통신학회논문지
    • /
    • 제6권2호
    • /
    • pp.262-267
    • /
    • 2011
  • 본 연구에서 동부산S/S #3M.Tr 및 부민S/S #1,2M.Tr의 중성선에 설치 사용 중인 NGR 과열원인을 분석하고 해소방안을 제시하여 안정적 전력공급에 이바지하고자한다. 전력계통에 사용 중인 변압기 중성점 접지리액터는 1선지락 고장시 변압기에 유입되는 지락고장전류의 크기를 제한하여 변압기 고장을 감소시키는 역할을 하며 가공절연전선의 용융단선고장방지 일단접지변압기 폭발가능성방지 차단기 차단용량감소 등에 기여하는 설비로 고장발생시 전력계통운용에 막대한 지장을 초래할 수 있다. 따라서 전력계통에 설치 운전 중인 동부산S/S #3M.Tr 중성점 접지리액터 TOP&BOTTOM BRACE부의 온도 상승원인분석과 부민S/S 중성점 접지리액터에 흐르는 과전류로 인한 과열원인 분석을 하였다.

22.9kV 지중선로용 한류기 한전 실계통 시범적용 (Application of Fault Current Limiter in 22.9kV KEPCO power distribution line)

  • 김민지;박경원;안길영;김영근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1034-1035
    • /
    • 2015
  • Watertight 25.8 kV/600 A/12.5 kA fault current limiters (FCLs) have successfully installed in five areas (Incheon, Seoul, Gyeong-gi, Daejeon, Suwon) on KEPCO power distribution line for the purpose of commercial demonstrations. The fault current limiting operation of this FCL, which includes functions of sensing, commutation, and reduction of fault currents, is perfectly completed within 1 cycle immediately after fault occurs. The performance of FCL was verified by short circuit test, impedance test, insulation test, temperature-rise test, and control test, etc at PT&T in LS industrial systems, which is the official certification institute in Korea. In 2013, and also the FCL field test was performed in order to test the protection coordination between conventional relays and FCL, on the 1.5 kA and 5.0 kA faults, which were made by connecting the Artificial Fault Generator (AFG) to the distribution line in test grid at KEPCO Power Testing Center. The next step of this project is to check the FCL conditions caused by real external environment, and acquire the various data from five regions installed with FCL. In this paper, we intend to explain the FCL specifications and performance characteristics, and check the expected effect by application of FCL to power distribution line based on the power system analysis of an application site.

  • PDF

해상풍력발전기 직격뢰 보호용 1등급 바리스터 개발 (Development of class I surge protection device for the protection of offshore wind turbines from direct lightning)

  • 이건희;박재현;정경진;강성만;최승규;우정민
    • 풍력에너지저널
    • /
    • 제14권4호
    • /
    • pp.50-56
    • /
    • 2023
  • With the abnormal weather phenomena caused by global warming, the frequency and intensity of lightning strikes are increasing, and lightning accidents are becoming one of the biggest causes of failures and accidents in offshore wind turbines. In order to secure generator operation reliability, effective and practical measures are needed to reduce lightning damage. Because offshore wind turbines are tall structures installed at sea, the possibility of direct lightning strikes is very high compared to other structures, and the role of surge protection devices to minimize damage to the electrical and electronic circuits inside the wind turbine is very important. In this study, a varistor, which is a key element for a class 1 surge protection device for direct lightning protection, was developed. The current density was improved by changing the varistor composition, and the distance between the electrode located on the varistor surface and the edge of the varistor was optimized through a simulation program to improve the fabrication process. Considering the combined effects of heat distribution, electric field distribution, and current density on the optimized varistor surface, silver electrodes were formed with a gap of 0.5 mm. The varistor developed in this study was confirmed to have an energy tolerance of 10/350 ㎲, 50kA, which is a representative direct lightning current waveform, and good protection characteristics with a limiting voltage of 2 kV or less.

LC 공진 필터를 이용한 전해 커패시터 없는 LED 구동용 PFC CCM 플라이백 컨버터의 출력 전류 리플 저감에 관한 연구 (The Study of Ripple Reduction of the PFC CCM Flyback Converter without Electrolytic Capacitor for LED Lightings using LC Resonant Filter)

  • 김춘택;김영석
    • 전기학회논문지
    • /
    • 제65권4호
    • /
    • pp.601-610
    • /
    • 2016
  • The light-emitting diode (LED) has been used in a variety of industrial fields and for general 0lighting purposes on account of its high efficiency, low power consumption and long lifespan. The LED is driven by direct current; therefore, an AC/DC converter is typically required for its use. An electrolytic capacitor is generally used for stabilizing DC voltage during use of the AC/DC converter. However, this capacitor has a short lifespan, which makes it a limiting factor in LED lighting. Furthermore, LED lighting requires a dimmable control to enable energy savings and fulfil a growing consumer demand. In this paper, the dimmable single-stage power factor correction (PFC) continuous conduction mode (CCM) flyback converter that employs no electrolytic capacitor is presented. The LC resonant filter is alternatively applied to reduce the 120[Hz] ripple on the output. And the optimum value of the LC resonant filter parameters considering both efficient and performance is analysed. Simulation and experimental results verify the satisfactory operation of the converter.

무부하 충전케이블 개방시 잔류전압에의한 과전압계전기 동작현상 연구 (A Study of Over Voltage Ground Relay Operation Status at Opening of No-load Charged Cable)

  • 김영한;최종혁;윤기섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.185-187
    • /
    • 2000
  • Fault current is flowed into 154/23kV M. Tr when line-to-ground fault occurs in power system. NGR(Neutral Grounded Reactor) is set up in order to prevent M.Tr fault by limiting magnitude of fault currents. Here, disconnection of NGR causes voltage increase by L-C resonance and line-to-ground fault in an unearthed system results in voltage increase at healthy phases. So Over Voltage Ground Relay(OVGR) is used for tripping M.Tr. Also, buses at second phases of M.Trs are all connected with section circuit breakers closed for the purpose of parallel operation and load shedding. In case of speciality buses are comprised of power cable in part for GIS connection. When no-load charged cable or bus is open by a section CB, unbalanced voltage charged on the bus is induced. Also discrepant opening time for circuit breakers on different phases gives rise to unbalanced zero sequence voltage. It was observed that this zero sequence voltage detected in the 22.9kV P.T (Potential Transformer for bus) mal-operated 59GT and tripped M.Tr. The zero sequence voltage of which vanishing time is longer than relay operating time came out by EMTDC simulation. Also, it was shown that the voltage waves of actual test are similar to those of simulation. On the basis of above results, R-C circuit complement on the relay without any effect on a power system made operating time of the relay longer than vanishing time of distorted waves. Consequently, operating time of the relay was delayed and magnitude of distorted waves was decreased by increasing time constant of the relay.

  • PDF

Improvement of Degradation Characteristics in a Large, Racetrack-shaped 2G HTS Coil for MW-class Rotating Machines

  • Park, Heui Joo;Kim, Yeong-chun;Moon, Heejong;Park, Minwon;Yu, Inkeun
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1166-1172
    • /
    • 2018
  • Degradation due to delamination occurs frequently in the high temperature superconductors (HTS) coil of rotating machines made with 2nd generation (2G) HTS wire, and the authors have observed other similar cases. Since an HTS field coil for a rotating machine is required to have stable current control and maintain a steady state, co-winding techniques for insulation material and epoxy resin for shape retention and heat transfer improvement are applied during coil fabrication. However, the most important limiting factor of this technique is delamination, which is known to be caused by the difference in thermal expansion between the epoxy resin and 2G HTS wire. Therefore, in this study, the experimental results of mixing the ratio of epoxy resin and alumina ($Al_2O3$) filler were applied to the fabrication of small and large test coils to solve the problem of degradation. For the verification of this scheme, eight prototypes of single pancake coils with different shapes were fabricated. They showed good results. The energization and operation maintenance tests of the stacked coils were carried out under liquid neon conditions similar to the operation temperature of an MW-class rotating machine. In conclusion, it was confirmed that the alumina powder mixed with epoxy resin in an appropriate ratio is an effective solution of de-lamination problem of 2G HTS coil.