• 제목/요약/키워드: Current limiting and discharge

검색결과 22건 처리시간 0.023초

정전기 방전시의 소나무목분의 최소착화에너지 측정에 관한 연구 (A Study of Measurement of Minimum Ignition Energy for Pine Tree Dust on Electrostatic Discharges)

  • 이동훈;박한석
    • 한국안전학회지
    • /
    • 제13권3호
    • /
    • pp.74-79
    • /
    • 1998
  • To establish measuring method for minimum ignition energy of explosive powders caused by electrostatic discharge, A measuring method(Hartman) using a very small quantity of pine tree testing powder was proposed, and the influence of discharge current limiting resistance connected in series into a capacitive discharge circuit on ignition energies of explosive powders was investigated. As a result the minimum ignition energy was 42.25mJ when discharge current limiting resistance 300 $k\Omega$.

  • PDF

고온 초전도 퓨즈의 한류 및 방전 특성 (Current Limiting and Discharge Characteristics of High Tc Superconductive Fuse)

  • 최효상
    • 한국전기전자재료학회논문지
    • /
    • 제17권6호
    • /
    • pp.673-677
    • /
    • 2004
  • We present the basic properties of a superconductive fuse (SF) based on YBCO/Au films. The SF consists of YBCO stripes covered with Au layers for current shunt. The fault current was limited to a designed value in less than 0.4 msec by resistance development in YBCO/Au upon quenching. This enabled the SF to transfer small fault power and the suppressed current was sustained for more than 0.5 msec while Au layer melting and arcing. The arcing time was less than 2.5 msec, that is short enough to do self-interruption. Under the source voltage of 100 $V_{rms}$, the longer the duration time of fault current was, the shorter its discharge time was. The duration time of fault current and its discharge time were reduced by increased voltages in the range of 200 - 300 $V_{rms}$. We thought that this was because the quench propagation was limited by local melting generated with higher voltage.age.

고온 초전도 한류퓨즈의 전압별 동작특성 (Operating characteristics of high Tc superconducting current limiting fuse at various voltages)

  • 최효상;현옥배;김혜림;황시돌;박권배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.161-163
    • /
    • 2001
  • We present the basic properties of a superconducting current limiting fuse (SCLF) based on YBCO/Au films. The SCLFs consists of YBCO stripes covered with Au layers for current shunt. Under the source voltage of 100 $V_{rms}$, the longer the duration time of fault current was, the shorter its discharge time was. The duration time of fault current and its discharge time were reduced by increased voltages in the range of 200 - 300 $V_{rms}$. We thought that this was because the quench propagation was limited by local melting generated with higher voltage.

  • PDF

절연유-절연지에서 이중 임피던스에 의해 부분방전측정 (Partial Discharge Measurement of Oil-Paper Insulation by Dual Measuring Impeadance)

  • 김광화;류희석;선종호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1778-1780
    • /
    • 1996
  • In this paper, we describe the partial discharge measurement with measuring impedance to have two wide frequency band transformers(filters) in the oil-paper and air insulation. The measuring impedance consists of high and low limiting frequency transformers. This measuring impedance could be measured the partial discharge current wave. We have the results that the amplitude partial discharge pulse ratio of low limiting frequency tranformer to high limiting frequency one is varied in the condition(in oil-paper insulation and air) to generate partial discharge.

  • PDF

한류형 반도체 교류 차단기 개발에 관한 연구 (A Study on Development of Current Limiting solid-state AC circuit Breaker)

  • 이우영;김용주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.73-77
    • /
    • 1990
  • In this paper we describe the solid-state ac-circuit breaker which has the characteristic of both a half cycle circuit breaker and a current limiting circuit breaker. This circuit breaker has a current limiting resistor in order to surprises the fault current to a certain level and discharge the energe included in circuit inductor. We explain the effect of circuit parameter on transient phenomena of switch device by using EMTP and finally design the control circuit consisted synchronous closing circuit, over- current detecting circuit and sensing circuit of rate of rise of fault current.

  • PDF

New electrode structure for reducing power consumption of PDPs

  • Jung, Hae-Yoon;Cheong, Hee-Woon;Lee, Tae-Ho;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.69-72
    • /
    • 2008
  • A new electrode structure is proposed in this paper which can increase the discharge efficiency of plasma display panels and also decrease the panel capacitance by decreasing the electrode area effectively. Even with the decreased electrode area, the proposed structure could suppress the requirement for increasing the voltage and improve efficiency by limiting the discharge current.

  • PDF

초전도 퓨즈의 전압별 특성 (Characteristics of a superconductive fuse according to applied voltages)

  • 최효상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.169-172
    • /
    • 2004
  • We present the basic properties of a superconducting current limiting fuse (SCLF) based on YBCO/Au films. The SCLFs consists of YBCO stripes covered with Au layers for current shunt. Under the source voltage of 100 $V_{rms}$, the longer the duration time of fault current was, the shorter its discharge time was. The duration time of fault current and its discharge time were reduced by increased voltages in the range of 200 - 300 $V_{rms}$. We thought that this was because the quench propagation was limited by local melting generated with higher voltage.

  • PDF

퓨즈가 내장된 엘보접속재의 설계 (Design of Fuse Mounted Elbow Connector)

  • 최경선;이철호;송일근;권태종;권영복;한명관
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.383-386
    • /
    • 2000
  • Fuse mounted elbow connector used for pad mounted transformer was designed and investigated. Requirements of electrical ratings such as partial discharge, ac withstand voltage and impulse voltage and material properties were proposed in accordance with IEEE 386 and pre-standard (PS) 147-219∼229 of KEPCO. The connector can be jointed with pad mounted transformer and current limiting fuse which is installed inside of the connector easily replaced with new one in the case of breakdown of the fuse. Electric field analysis was also introduced in other to verify the reliability of the design.

  • PDF

전착과산화납양극에 의한 옥소산염 전해산화 (Anodic Oxidation of Iodate to Periodate by Lead Peroxide Anode)

  • 남종우;김학준
    • 대한화학회지
    • /
    • 제15권6호
    • /
    • pp.324-329
    • /
    • 1971
  • In order to evaluate the mechanism of electrolytic oxidation of iodate and to determine the optimum conditions for the electrolysis, studies were made using the cells without diaphragm and the lead peroxide anode. Results are summarized as followings: 1) Current density vs. anode potential curve by lead peroxide electrode had the different limiting current densities from platinum electrode and was more positive than platinum electrode. 2) Additions of potassium bichromate in the electrolyte contribute to maintain high current efficiency. 3) In the acid and alkaline regions, the current efficiencies decreased by reduction of iodate and discharge of hydroxyl ion, so maximum current efficiency was shown at pH 7. 4) Higher current density lowered the current efficiency in the region of 60-80% conversion of iodate. 5) Influence of the conversion on current efficiency in the region of 60-80% conversion of iodate.

  • PDF

수중 펄스코로나 방전을 중첩한 고효율 강전해수 발생장치 (A High Efficiency Electrolytic Cell by Superposing Pulsed Corona Discharge in Water)

  • 이재용;김진규;정성진;박승록;문재덕
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권2호
    • /
    • pp.79-85
    • /
    • 2001
  • A conventional electrolyzing cell has been made by an ion exchange membrane inbetween parallel plate electrodes. A low dc voltage is applied to the electrodes for electrolyzing and the efficiency is remained in low. in this study, a novel electrolyzing cell with a pair of slit-type third electrodes installed inbetween parallel plate electrodes has been proposed and investigated experimentally. And pulse power wa supplied to between each electrodes. This slit type of third electrodes can concentrate the strong electric fields at the every its edges to accelerate the electrolyzing powers, and to generate oxygen bubble discharges for generating oxidants. And moreover the slits eliminate the space charge limiting action and the temperature of the water by leaking out through the slits from electrolyzing region to outside of the main electrode region. As a result, it was found that a strong electorzed water of pH 2.8 and pH 10.5 and oxidants dissolved water of 1 [ppm] in acidic water were obtained with a tap water fed at the electric current of 2 [A], which however were several times higher oxidant and ion concentration quantity compared with the conventional cell.

  • PDF