• Title/Summary/Keyword: Current Velocity

Search Result 1,427, Processing Time 0.028 seconds

Analysis of Flow Velocity Change in Blade Installed Shroud System for Tidal Current Generation (블레이드가 설치된 조류발전용 쉬라우드 시스템 내 유속 변화 분석)

  • Lee, Uk Jae;Han, Seok Jong;Jeong, Shin Taek;Lee, Sang Ho
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.31 no.1
    • /
    • pp.9-16
    • /
    • 2019
  • Flow velocity changes in the shroud system for tidal current power generation due to experimental flow velocities and blade geometry changes were analyzed by hydraulic experiment and numerical simulation. Through the hydraulic experiment, flow velocities at inlet of shroud system and RPM according to blade geometry were measured, and numerical simulation was used to analyze flow velocity changes in shroud. When the experimental flow velocity was increased by about 28% and the shape of the airfoil was applied, the measured flow velocity at the shroud inlet tended to increase by up to about 56%. On the other hand, when airfoil-shaped blades were installed, the flow velocity at the inlet tended to increase by up to 14% compared to conventional blades, and RPM was also the highest at the same conditions. The hydraulic experiment and numerical simulation results showed an error of about 13%, and the trends of the flow velocity changes in each result are similar. Numerical simulation of the flow velocity changes in the shroud showed that the flow velocity tended to increase 1.7 times at the front of the blade compared to the inlet. The results of the flow velocity change analysis in the shroud system obtained from this study will provide the basic data necessary for the development of efficient shroud system for tidal current power generation.

Nonlinear Interaction among Wave, Current and Submerged Breakwater (파랑-흐름-잠제의 비선형 상호간섭 해석)

  • Park, Su-Ho;Lee, Jung-Hoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.6
    • /
    • pp.1037-1048
    • /
    • 2016
  • In this study, nonlinear wave interaction in the presence of a uniform current is studied using numerical model, named CADMAS-SURF which is based on the Navier-Stokes equations coupled with Volume of Fluid for tracking free surface deformation. The original CADMAS-SURF developed for interaction of wave with structure is modified/extended to simulate nonlinear fluid dynamic motions within wave-current coexisting field. The capability of Numerical Wave-Current Tank (NWCT) in this study is validated by comparing with available existing laboratory experiments for both wave-following and wave-opposing current. The numerical results for interaction between wave and current are shown to be in good agreement with experimental data. Then, this study focused on the dynamic motions of the water velocity, surface elevation and vorticity within combined wave-current field in demonstrating complex nonlinear physical phenomena due to interaction between wave and current. In addition, NWCT is applied to simulate a more complex wave-current-structure field for wave propagating over a submerged breakwater associated with current. Detailed discussion including characteristics of velocity and vorticity fields and the relation between free surface and vorticity are given.

A Study on the Phase Transition of DPPC Organic Films (DPPC 유기박막의 상전이에 관한 연구)

  • 김동관;이순형;최영일;최충석;장희동;이경섭
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.491-494
    • /
    • 2000
  • Conductive Langmuir-Blodgett(LB) films have recently attracted much interest from the viewpoint of ultrathin film conductors at the molecular level. The result shows that the Maxwell-displacement-current(MDC) measuring technique is useful in the detection of phase-transition over the entire range of molecule areas. At the liquid-solid phase transition, a striking feature in the present current measurement was observed; the I-A isotherm for a DPPC monolayer has sharp bend. Dynamic behavior of monolayers in the presence of an external field was also investigated using the current-measuring technique. Dynamic behavier of DPPC monolayer was measured by displacement current when the molecules are stimulated by pressure velocity. As result, it is known that current is generated of higher current pe마 as compression velocity become faster. Also, in order to clarify the reorganization of the lipid monolayers, it is instructive to plot the relationship between I and 1/$A^2$.

  • PDF

Analysis of Air Current Measurements at External Induction-Style Kitchen and Bathroom Vents (외기유인형 주방·욕실 배기구의 기류측정 분석)

  • Lee, Yong-Ho;Kim, Seong-Yong;Park, Jin-Chul;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.76-84
    • /
    • 2012
  • This study conducted experiments to measure air currents in an experimental building according to external conditions, types of induction ducts, and types of internal sockets by applying an external induction duct comprised of inducing openings and lines and induction units to the kitchen and bathroom vents at the rooftop of a super high-rise apartment building in order to help to improve the venting performance. The study also proposed the optimization of the external induction-style kitchen and bathroom vents capable of wind power generation. (1) As for air current distribution according to vent velocity changes, it increased the venting performance of the kitchen and bathroom by 1.0m/s at vent velocity of 2.0m/s or higher and allowed for wind power generation. (2)As for air current distribution according to external velocity changes, it increased the venting performance of the kitchen and bathroom by 1.2m/s at external velocity of 2.0m/s or higher and allowed for wind power generation. (3)As for air current distribution according to wind direction changes($0{\sim}180^{\circ}$), it was favorable for higher vent velocity when the angle between the external induction duct direction and prevailing wind direction was within ${\pm}30^{\circ}$. (4)As for air current distribution according to induction duct type, the[M1] type combining the inducing openings and lines with the induction units recorded the highest improvement effects in the kitchen and bathroom venting performance by increasing vent velocity by 46%. (5)As for air current distribution according to the changing types of internal sockets where the main ducts of the kitchen and bathroom are connected to the external induction ducts, the venturi tube type[Sv] increased vent velocity by 66% based on the smoothest external inflow.

Environmental Factors and Catch Fluctuation of Set Net Grounds in the Coastal Waters of Yeosu - 2 . Sea Water Circulation in the Vicinity of Set Net Ground - (여수연안 정치망어장의 환경요인과 어황 변동에 관한 연구 - 2 . 어장주변 해역의 해수유동 -)

  • Kim, Dong-Soo;Rho, Hong-Kil
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.30 no.3
    • /
    • pp.142-149
    • /
    • 1994
  • In order to investigate the environmental properties of set net grounds located in the coastal waters of Yeosu. The current in the vicinity of set net grounds was observed by drogue and current meter in 1990 and 1992. The results obtained are summarized as follows: The direction of tidal current at the north enterance of Yeosu bay was southerly in ebb and northwesterly in flood without the distiction of the neap tide and the spring tide. In spring tide the maximum Velocity of the tidal current was 68 cm/sec in ebb and 66 cm/sec in flood. In neap tide the maximum velocity of the tidal current was 37 cm/sec in ebb and 35 cm/sec in flood. And so the direction of residual current was the south ward mainly and 21 cm/sec. The direction of tidal current at set net fishing grounds was southwesterly in ebb and westerly or northwesterly in flood. Regardless of the distinction of neap and spring. The maximum velocity of the current in spring tide was 50 cm/sec in ebb and 40 cm/sec in flood and that in neap was 28 cm/sec in ebb and 25 cm/sec in flood. In spring tide the speed vector along the major axis of semidiurnal tide component was three times as large as diurnal tide. In neap tide, however, the speed vector was about 50% less then that in spring tide, and the semidiurnal tide and diurnal tide were equal in the size of current ellipse and the direction of major axis. The sea area had a southwesterly residual current. 11 cm/sec in spring tide and 7 cm/sec in neap tide. According to the result of drogue tracking, the vicinity of set net fishing ground had a southerly residual current which formed in Yeosu Bay and a weak westerly residual current toward Dolsando from Namhedo. Therefore, set net fishing ground in coastal water of Yeosu was distributed in boundary of inner water which formed from Seamjin river and offshore water supplied from the vicinity of Sorido and Yochido.

  • PDF

Current Distribution and Skin Effect in the Rail of an Electromagnetic Railgun. (전자레일건 래일에서의 전류분포 및 표피효과)

  • 임달호;구태만
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.12
    • /
    • pp.848-855
    • /
    • 1987
  • The currents in the rails of an electromagnetic railgun are concentrated in a near surface region. In order to understand this phenomenon, this paper deals with computation of the current distribution related to skin effect in a railgun. An analytical solution is obtained for a twodimensional model. It is found that current concentration at the interface between the rails and the armature is affected by the velocity, length and conductivity of the armature, that skin effect in the rails is affected by the relative velocity between the rails and the armature rather than other factors, and that skin depth in the rails is inversely proportional nearly to the square root of the velocity.

  • PDF

A Study on the Flow-Accelerated Corrosion Characteristics of Galvanically Coupled Dissimilar Metals. (이종금속 연결에 따른 침부식(FAC) 특성에 관한 연구)

  • Kim, Jung-Gu
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.269-272
    • /
    • 2000
  • The flow accelerated galvanic corrosion characteristics of a carbon steel coupled to stainless steel were investigated in deaerated alkaline-chloride solutions as a function of flow velocities(0, 0.2, 0.4 and 0.6 m/s), pH(8, 9, and 10) and temperature(25, 50 and $75^{\circ}C$). The electrochemical properties of specimens were investigated by potentiodynamic test and galvanic corrosion test using RCE(Rotating Cylinder Electrode). Carbon steel did not show passive behavior in the alkaline-chloride solution. The galvanic current density increases with increasing flow velocity and temperature, but decreased with increasing pH. Flow velocity had a small effect on the galvanic current density at $25^{\circ}C$, whereas the flow velocity increased galvanic current density significantly at $50^{\circ}C$ and $75^{\circ}C$. This might be due to the increased solubility of magnetite at the higher temperature.

  • PDF

HALL EFFECTS ON HYDROMAGNETIC NATURAL CONVECTION FLOW IN A VERTICAL MICRO-POROUS-CHANNEL WITH INJECTION/SUCTION

  • BHASKAR, P.;VENKATESWARLU, M.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.24 no.1
    • /
    • pp.103-119
    • /
    • 2020
  • In this work, the hydromagnetic and thermal characteristics of natural convection flow in a vertical parallel plate micro-porous-channel with suction/injection is analytically studied in the presence of Hall current by taking the temperature jump and the velocity slip at the wall into account. The governing equations, exhibiting the physics of the flow formation are displayed and the exact analytical solutions have been obtained for momentum and energy equations under relevant boundary conditions. The impact of distinct admissible parameters such as Hartmann number, Hall current parameter, permeability parameter, suction/injection parameter, fluid wall interaction parameter, Knudsen number and wall-ambient temperature ratio on the flow formation is discussed with the aid of line graphs. In particular, as rarefaction parameter on the micro-porous-channel surfaces increases, the fluid velocity increases and the volume flow rate decreases for injection/suction.

The Study on The Complex Composition By SFCL and Power Equipments for Fault Detection in HVDC Line (HVDC 선로 내 초전도 한류기와 전력기기들의 복합 구성을 통한 고장 검출에 관한 연구)

  • Kim, Myong-Hyon;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.8
    • /
    • pp.1113-1118
    • /
    • 2018
  • Protection in HVDC(High Voltage Direct Current) have the very fast velocity of fault detection. Because Fault in HVDC has the fast propagation, large currents, high interruption cost. The focus to velocity caused possibility of errors like a detection error like a high impedance fault. In this paper, Proposed complex composition for get the reliability and velocity. That used SFCL(Super Conducting Fault Current Limiter), Protection Zone and DTS(Distributed Temperature Sensing). The SFCL was detect the fault by quench and DTS&Protection Zone were perceive the detect by variation too. To examine the proposed method, PSCAD/EMTDC simulated. The results of simulation, proposed methods could the detect of fault to whole HVDC line. And that improved the reliability of fault clearing.

A Study on the Collection Characteristics of a Moving Electrode Electrostatic Precipitator - I. Effect of Collection Plate Velocity - (이동 전극형 전기집진기의 집진특성에 관한 연구 - I. 집진판 이동 속도의 영향-)

  • Kim Yong-Jin;Ha Byung-Kil;Jeong Sang-Hyun;Moon Sang-Cheol;Yoo Joo-Sik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.901-907
    • /
    • 2004
  • This study investigate the effect of collection plate velocity on the electrical and collection characteristics of a moving electrode electrostatic precipitator (MEEP). Though a high resistivity fly ash is attached at the collecting electrode, the MEEP has very stable characteristics of voltage and corona current. Collection efficiency, corona current, and overall collection efficiency are increased, as the magnitude of the collection plate velocity increases.