• Title/Summary/Keyword: Current Sensorless

Search Result 384, Processing Time 0.026 seconds

A New Starting Method of Brushless DC Motor without Position Sensor (위치 센서가 없는 소형 BLDC 전동기의 기동 방법에 관한 연구)

  • Lee Wook-Jin;Sul Seung-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.646-650
    • /
    • 2004
  • This paper presents a novel method to detect the rotor position of the BrushLess DC(BLDC) motor at standstill and a start-up method to accelerate the rotor up to a certain speed where the conventional position sensorless control methods based on the back EMF could work reasonably The proposed initial rotor position estimation method is suitable to avoid the temporary reverse rotation or the starting failure. This method can be implemented using only one current sensor at DC link of the inverter. It does not depend on the model of the motor , and it is robust to motor parameter variations. By the proposed method, it is demonstrated experimentally that a stable starting can be achieved even with severe mechanical disturbance.

  • PDF

Enhancement of Sensorless Performance Using Current Shaping in SMPM Machine Drive (상전류 변형을 이용한 표면 부착형 영구자석 전동기의 센서리스 성능 향상)

  • Kim, Jin-Woong;Ha, Jung-Ik
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.31-32
    • /
    • 2014
  • 전압형 인버터를 이용한 전동기 구동시스템에서, 출력전압의 비선형성은 역기전력기반 센서리스의 성능에 큰 영향을 미친다. 역기전력기반 센서리스는 전압방정식을 이용하기 때문에 출력전압에 대한 정보가 필요한데 일반적인 인버터에는 출력전압을 측정하는 센서가 없어 출력전압지령을 출력전압과 같다고 가정하고 사용한다. 그러나 인버터의 비선형성으로 인해 전압지령과 실제 출력되는 전압간의 차이가 발생하게 되어 각 추정오차가 생기게 되고 센서리스의 성능을 떨어트린다. 인버터 비선형성의 주원인인 데드타임에 의한 영향을 보상하기 위해서 여러 가지 방법들이 연구되었지만 전류의 크기가 낮은 저속, 저부하 상황에서는 여전히 오차가 존재 하였다. 본 논문에서는 전압오차가 발생할 수 있는 저전류 구간을 최대한 줄이도록 전류의 형태를 바꾸어 저속 저부하 상황에서의 전압오차를 최소화 하였다. 이를 통해서 역기전력 기반의 센서리스의 저속영역 특성을 개선하였고 실험을 통해 그 효용성을 검증하였다.

  • PDF

Development of an Automatic Cardiac Output Control Algorithm for the Total Artificial Heart (완전 이식형 인공심장의 심박출량 자동 제어 알고리즘 개발에 관한 연구)

  • 최원우;김희찬;민병구
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.32B no.3
    • /
    • pp.38-47
    • /
    • 1995
  • A new automatic cardiac output control algorithm for the motor-driven electromechanical total artificial heart(TAH) was developed based on the motor current waveform analysis without using any extra transducer. The basic control requirements of artificial heart can be described in terms of three features : preload sensitivity, afterload insensitivity, and balanced ventricular outputs. In the previous studies, many transducers were utilized to obtain informations of hemodynamic states for the automatic cardiac output control, But such automatic control systems with sensors have had reliability problems. We proposed a new sensorless automatic cardiac output control algorithm providing adequate cardiac output to the time-varying physiological demand without causing right atrial collapse, which is one of the critical problem in an active-filling type device. In-vitro tests were performed on a mock circulation system to evaluate the performance of the developed algorithm and the results show that the new algorithm satisfied the basic control requirements on the cardiac output response and the possibility of application of the developed algorithm to in vivo experiments.

  • PDF

Driving Algorithm on Three Phase BLDC Motor Applied 4-Switch using Voltage Doubler (Voltage Doubler를 이용한 4-스위치 3상 BLDC 전동기 구동 알고리즘)

  • Yoon, Yong-Ho;Lee, Jung-Suk;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.1
    • /
    • pp.48-52
    • /
    • 2011
  • Over the years, traditionally, six-switch three-phase inverters have been widely utilized for variable speed alternating current motor drives. Recently, some efforts have been made on the application of four-switch three phase inverter for uninterruptible power supply and variable speed drives. This is due to some advantages of the four-switch three phase inverter over the conventional six-switch three-phase inverters such as reduced price due to reduction in number of switches, reduced switching losses, reduced number of interface circuits to supply logic signals for the switches, simpler control algorithms to generate logic signals, less chances of destroying the switches due to lesser interaction among switches, and less real-time computational burden. However such as slow di/dt and speed limitation, are the inherent characteristics and main drawbacks of the four-switch configuration. Those problems can be overcome in conjugation with Voltage-doublers which has additional advantage, such as unity power factor correction.

Simultaneous Estimation of the Speed and the Secondary Resistance under the Transient State of Induction Motor

  • Akatsu, Kan;Kawamura, Atsuo
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.298-303
    • /
    • 1998
  • In the speed sensorless control of the induction motor, the machine parameters (especially the secondary resistance R2) have a strong influence to the speed estimation. It is known that the simultaneous estimation of the speed and R2 is impossible in the slip frequency type vector control, because the secondary flux is constant. But the secondary flux is not always constant in the speed transient state. In this paper the R2 estimation in the transient state without adding any additional signal to the stator current is proposed. This algorithm uses the least mean square algorithm and the adaptive algorithm, and it is possible to estimate the R2 exactly. This algorithm is verified by the digital simulations and the experiments.

  • PDF

Development of BLDC Motor Controller for Tread Mill Application (Tread Mill 구동용 BLDC 제어기 개발)

  • Ahn Jin-Woo;Lee Dong-Hee;Park Sung-jun
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.138-141
    • /
    • 2002
  • BLDCM(Brushless D.C. Motor) is widely used for industrial application because of high efficiency and high power density Especially, in servo system and home appliance, BLBCM is very useful due to high control performance and low acoustic noise. In this paper, 2.5HP rated BLDCM controller and drive was developed for tread mill application. The prototype BLDCM has 4 poles rotor and 24 slots stator. Ferrite was used as a rotor magnet due to the cost and temperature characteristic. For the stable operation of tread mill, over current and high temperature can be detected by the DSP controller. For the commutation signal, switching patterns from the sensorless circuit and hall sensor signal are used in the DSP controller.

  • PDF

Sensorless Vector Control of Induction Motor using the IP Controller (IP제어기를 이용한 유도전동기의 센서리스 벡터제어)

  • Jun, Kee-Young;Jho, Jeong-Min;Hahm, Nyoun-Kun;Lee, Seung-Hwan;Lee, Hoon-Goo;Han, Kyung-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.1993-1995
    • /
    • 1998
  • The compensation problem of error and various problems due to delay of speed sensor itself and speed detection have issued in case using speed sensor in the adjustable speed control of induction motor. This paper have applied the stator flux oriented vector control algorithm and space voltage vector PWM method in order to improve an dynamic character of voltage-source inverter system, and also used the better IP controller in the speed response than Pl controller as speed controller. This paper estimated the rotator speed using input current of inductor motor and flux component invoked through voltage drop by terminal voltage and stator resistor.

  • PDF

Phasor Analysis of Sensorless Vector Control System Model for Induction Motor (유도전동기 센서리스 벡터제어 시스템 모델의 페이저 해석)

  • Lee, H.J.;Hwang, J.H.;Seong, S.J.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2015-2017
    • /
    • 1998
  • This paper deals with the design of a field oriented control system model for the high performance induction motor using Matlab with Simulink. The proposed control system model, which is not used the speed and flux sensor, contains IM model, Tranformation, Decoupling, FFOC(Field Flux Orientation Controller), Torque calculator and PI Controller to control speed, torque. Results present the stator and rotor flux phasor trajectory, the startup and transient response of speed, torque and stator current with field oriented control and the response to changes in reference speed with no load. This paper shows that the propose control system is more robust than other vector control system, and suggest the enchanced model, using Matlab with Simulink for the high performance in induction motor control.

  • PDF

A Study on the New Parameter Estimation Technique of Direct Current Motor (직류전동기의 새로운 파라미터 추정기법에 관한 연구)

  • Kim, Jong-Su;Kim, Sung-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.4
    • /
    • pp.441-447
    • /
    • 2007
  • The speed and torque control performance of the DC motor used in the industrial field is affected by the change of parameters. In particular the change of armature resistance can be greatly originated from various load conditions. Accordingly a large number of studies to estimate those problems in the servo motor control field have already been under way. In this paper, the armature resistance on the DC motor under several load and speed conditions is estimated by the Artificial Neural Network(ANN), and the validity is proven by the speed estimation of sensorless speed control system.

Control System for Tread Mill BLDCM Drive quality Elevation (Tread Mill용 BLDCM의 구동 특성 향상을 위한 제어시스템)

  • Lee Ju-Hyun;Lee Dong-Hee;Ahn Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1019-1021
    • /
    • 2004
  • BLDCM(Brushless D.C. Motor) is widely used for industrial application because of high efficiency and high power density. Especially, in servo system and home appliance. BLDCM is very useful due to high control performance and low acoustic noise. In this paper, 2.5HP rated BLDCM controller and drive was developed for tread mill application. The prototype BLDCM has 4 poles rotor and 24 slots stator. Ferrite was used as a rotor magnet due to the cost and temperature characteristic. For the stable operation of tread mill. over current and high temperature can be detected by the DSP controller. For the commutation signal, switching patterns from the sensorless circuit and hall sensor signal are used in the DSP controller.

  • PDF