• Title/Summary/Keyword: Current Pole

Search Result 383, Processing Time 0.025 seconds

Characteristics Analysis of V Shape Pole Changing Memory Motor using Finite Element Method (유한요소법을 이용한 V형상 극변환 메모리 모터의 특성 분석)

  • Kim, Young-Hyun;Kim, Su-Yong;Kim, Jung-Woo;Lee, Jung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.6
    • /
    • pp.872-877
    • /
    • 2015
  • The Permanent Magnet (PM) machine used at speed control using field-weakening control method. But the field-weakening current, which reduces the field flux for high speeds, causes significant copper and core losses. Therefore, this paper deals with the PM performance evaluations in a pole changing memory motor (PCMM). The PCMM can change the number of magnetic poles and produce two types of torque. When the motor operates with eight poles, it produces a magnetic torque at low rotational speeds. When the motor changes to four poles, it produces both magnetic torque and reluctance torque at high speeds. The paper explain the principle and basic characteristics of the motor by using a finite element method magnetic-field analysis, which consists of a PM magnetized by a pulse d-axis current of the armature winding. The results of our experiment show that the proposed motor reduces core loss by 10% and 55% under no-load and load conditions, and doubles the speed range of the motor.

A Study on the Removing Method of Hunting by Equalizing Line during Parallel Running of alternator Equipped with converter (컨버터가 내장된 교류발전기 병렬운전중의 헌팅을 균압선을 이용해 제거하는 방법에 관한 연구)

  • 노창주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.3
    • /
    • pp.352-359
    • /
    • 1999
  • This paper is a research for removing the alternators hunting which came about during the par-allel running. The four-pole six-phase alternator is equipped with the converter made out of twelve diodes to rectify all the waves. The hunting came about during the battery charging due to the hunting inducing point existed in r. p. m band 1575[rpm-1690[rpm] To remove the hunting inducing point We modified the four-pole six-phase alternator into the four-pole twevel-phase and increased the short-circuit ratio by decreasing the field coil pitch and increasing the field coil turns. But this method has two defects the first the alternator structure becomes complicating and the second the second the alternator equipped with the converter used in general purpose lately such as the car alternator can not be run in parallel wlthout modifying. To remove the defects the equalizing line was connected between the same phase of the alterna-tor to flow the synchronizing current which syncronize the phases of generator electromotive forces by which the alternator can be run in parallel without reference to the hunting inducing point and without modifying.

  • PDF

DESIGN OF SINGLE-SIDED LINEAR INDUCTION MOTOR USING FINITE ELEMENT METHOD AND SUMT (유한요소법과 SUMT를 이용한 편측식 선형유도전동기의 설계)

  • Im, Dal-Ho;Kim, Hak-Ryun;Lee, Cheol-Jik;Park, Seung-Chan
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.503-505
    • /
    • 1992
  • This paper describes the optimization of design variables of SLIM using finite element method and SUMT(Sequential Unconstrained Minimization Technique). Thrust is taken as an objective function in order to maximize thrust under constant current drive, and seven independent design variables and nine constraints are chosen. As a result, $\tau$/g(pole pitch/airgap) and $\tau$/$d_{AL}$(pole pitch/aluminum depth) of good criteria in SLIM design are determined.

  • PDF

A Study on the Welds Characteristics of 200 Grade Stainless Steel for Application of Street Pole Material (가로등주 소재 적용을 위한 200계 스테인리스강의 용접부 특성 연구)

  • Lee, B.W.;Lee, D.K.;Kim, H.S.;Hong, S.H.
    • Journal of Power System Engineering
    • /
    • v.13 no.3
    • /
    • pp.33-39
    • /
    • 2009
  • The aim of this study is to analyze the welds characteristics of the 205 stainless steel pipe for application of street pole material. The welds corrosion behavior of STS 205 pipe in 0.1 N sulphuric acid solution and 5% NaCl solution at room temperature was studied using both salt spray test and potentiodynamic polarization experiment. The morphology and components of corrosion products on surface of STS 205 pipe welds were investigated using SEM/EDX. The tensile strength and yield strength values of STS 205 plate were 715 MPa and 369 MPa respectively. The microvickers hardness values of STS 205 pipe welds were slightly increased than that of STS 304 pipe welds. Corrosion current density($I_{corr.}$) and critical current density($I_{crit.}$) values of STS 205 pipe welds in 3.5% NaCl solution were $1.89{\times}10^{-6}$ $A/cm^2$ and $15.8{\times}10 ^{-6}$ $A/cm^2$. The corrosion resistance of SIS 205 pipe welds was similar to its STS 304 pipe welds. The STS 205 and 304 pipe welds passive films were chromium oxide. Especially, the STS 205 pipe welds showed good corrosion resistance in 0.1 N sulphuric acid. This is attributed to the forming of protective chromium oxide on the surface of STS 205 pipe welds.

  • PDF

The Peak Load Forecast of Pole-Transformers by Working Electrical Energy (사용전력량에 의한 주방변압기의 최대 부하 예측)

  • Lee, Dong-Jun;Han, Sung-Ho;Lee, Wook;Kwak, Hee-Ro;Kim, Jae-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.101-103
    • /
    • 1996
  • This Paper describes Peak load forecasting technique of pole transformers with correlation equation. While customers are demanding safe energy supply, current correlation equation that is used for load management of pole transformers has some problems. To get accurate correlation equation. several correlation equation were examined using past data and nu data collected using the measuring instrument developed for this study. It was recognized that the quadratic equation was the most accurate for peak load forecasting from working electrical energy.

  • PDF

Computing EMF of Salient Pole Rotor Type Single Phase SRM (돌극형 회전자 단상 SRM의 유도기전력 산출)

  • Kim, Jun-Ho;Lee, Eun-Woong;Oh, Young-Woong;Lee, Min-Myung
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.868-870
    • /
    • 2001
  • Salient pole rotor type single phase SRM(switched reluctance motor) can be use axial direction magnetic flux and radial direction magnetic flux at the same time. Then, it has higher energy density per unit volume and can be lessened the shaft length of motor or exciting magnetic force. Additionally, it's durability is good because it is simple structure and driving device. Prototype of Salient pole rotor type single phase SRM was fabricated by using parameters of three phase SRM and 3D FEM analysis. Also, driving device was fabricated for prototype. Speed and torque characteristic was confirmed through the experiments, and flux linkage, which is important parameter of SRM for generating torque, was measured. The induction emf was calculated by using ideal inductance graph and current graph. Calculated emf and measured emf was compared for confirming loss of prototype in this paper.

  • PDF

A Squarewave current control LED driver of Totem-Pole AC/DC Converter Driving (Totem-Pole AC/DC 변환기 구동의 구형파 전류제어형 LED드라이버)

  • Kim, Jaesub;Niyitegeka, Gedeon;Choi, Jaeho
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.147-149
    • /
    • 2014
  • 본 논문에서는 LED드라이버의 지속적인 과제인 고역률, 효율개선 및 장수명화를 위한 연구를 진행하였다. 전체적인 토폴로지는 역률개선 및 출력전류제어의 성능을 자세히 관찰하기 위하여 투 스테이지 토폴로지를 선정하였으며, 1차측은 고 효율을 위하여 Bridgeless타입의 Totem-Pole bridgeless rectifier를 선정하였으며, 2차측은 LED드라이버의 수명을 좌우하는 DC 커패시턴스를 줄이기 위한 전류제어를 하기 위하여 Flyback DC-DC컨버터 토폴로지를 적용하였다. 일반적인 투 스테이지 토폴로지와 본 논문에서 제안한 토폴로지의 시뮬레이션 및 실험을 통하여 성능적인 분석을 통하여 LED드라이버의 효율증대 및 수명증가에 대한 내용을 다루었다.

  • PDF

Design and Drive of 3-phase 6/8 SRM (3상 6/8극 SRM의 설계 및 운전 특성)

  • Hao Chen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.48-55
    • /
    • 2003
  • The design and analysis of a three-phase 6/8 structure SRM(switched reluctance motor) art described. The range of the stator ole arc and the rotor pole arc of the motor we analyzed in the linear region. The optimum range of the stator pole arc and the turn-off angle of the main switches in the power converter are given with the 2-D finite element electro-magnetic field calculation of the motor and the nonlinear simulation. Test results of the prototype are discussed. This type is good for high efficiency drive because the drive circuit is simple and current density and copper loss of the winding are law.

Characteristics Analysis of Pole Changing Memory Motor According to Arrangement of magnet (영구자석 배열에 따른 극변환 메모리 모터의 특성 분석)

  • Kim, Young-Hyun;Seo, Jun;Lee, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.892-893
    • /
    • 2015
  • This paper deals with a characteristic that varies the number of magnetic pole in permanent magnet (PM) motor in order to reduce energy consumption. The pole changing memory motor (PCMM) can change the number of magnetic poles and produce two types of torque. When the motor operates with eight poles, it produces a magnetic torque at low rotational speeds. When the motor changes to four poles, it produces both magnetic torque and reluctance torque at high speeds. The paper explain the principle and basic characteristics of the motor by using a finite element method magnetic-field analysis, which consists of a PM magnetized by a pulse d-axis current of the armature winding. The results of our experiment show that the proposed motor reduces core loss by 10% and 55% under no-load and load conditions, and doubles the speed range of the motor.

  • PDF

A study on the development of diagnosis device for pole transformer deterior (주상변압기 열화진단장치 개발에 관한 연구)

  • Lee, Bo-Hoo;Kim, Jae-Chul;Kim, Young-Chun;Kim, Hun;Min, Kyung-Rae;Kim, Oun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1079-1081
    • /
    • 1998
  • This paper describes the dissipation factor measuring device for insulating oil in operating pole transformer by DSP(digital signal processor). After applying voltage to the sensor which is installed in a transformer, acquire source voltage and current of sensor using FFT techniques, then we could evaluate the dissipation factor of insulating oil. To improve measuring accuracy and processing speed, we use TMS320C31 DSP, FFT and data analysis techniques. Also we suggest deterioration criterion of insulating oil and compared the developed diagnosis device with schering bridge on deteriorated insulating oil. The result of this paper show that the developed measuring device can be used as diagnosis device for the pole transformers.

  • PDF