• 제목/요약/키워드: Current Mode Control

검색결과 1,001건 처리시간 0.033초

AN EFFICIENCY OPTIMIZED OPERATION OF INDUCTION MOTOR DRIVE SYSTEMS FOR ELECTRIC VEHICLES

  • Park, Uk-Don;Lee, Jae-Moon;Kim, Dong-Hee;Lee, Dal-Hae
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.938-943
    • /
    • 1998
  • The induction motor of the electric vehicles is controlled based on the vector control method to obtain good torque control characteristics. In the conventional vector control system, the field exciting current should be kept on a constant value to keep a stable flux level. This method has a liability that core loss becomes increasing at the light load region. To solve this liability, the efficiency maximizing control method of the vector controlled induction motor is proposed in thid paper. We developed light weight water cooled 60kW induction motor drive system which adopts our method and fabricated a conversion electric car for actual vehicle test. We demonstrate the usefulness of drive system by comparing its driving mode with conventional field oriented system and an efficiency maximizing controlled induction motor.

  • PDF

다층신경망을 이용한 전단모드 회전형 MR 댐퍼의 모델링 (Modeling of Shear-mode Rotary MR Damper Using Multi-layer Neural Network)

  • 조정목;허남;조중선
    • 한국지능시스템학회논문지
    • /
    • 제17권7호
    • /
    • pp.875-880
    • /
    • 2007
  • 자기변성유체(magnetorheological fluid)에 관한 연구는 MR 장치의 개발, MR 장치의 수학적 모델링 및 시뮬레이션, 그리고 MR 장치를 채용한 시스템의 제어 알고리즘 개발에 관한 연구로 구분된다. 시뮬레이션을 통한 제어 알고리즘 개발을 위해서는 MR 장치의 비선형 응답을 예상하기 위한 신뢰성 높은 수학적 모델이 요구된다. 또한 MR 장치 시스템을 제어하기 위해서는 제어기에서 요구하는 댐핑력을 출력하기 위한 MR 장치의 전류(또는 전압) 입력 값이 필요하며, 이 입력값을 얻기 위해서는 역댐퍼 모델이 필요하다. 이러한 이유로 MR 장치의 모델링 및 역댐퍼 모델링은 MR 장치개발의 중요한 역할을 담당하며 이에 관한 많은 연구가 요구되고 있다. 본 연구에서는 전단모드 회전형 MR 댐퍼의 모델링을 위해 개발된 MR 댐퍼를 이용하여 동특성 시험기를 제작하였으며, 전단모드 회전형 MR 댐퍼의 특성을 연구하기 위한 실험을 수행하였다. 시험기 시험결과를 통해 모델링에 필요한 시험 데이터들을 획득하였으며 다층신경망을 이용하여 전단모드 회전형 MR 댐퍼의 모델 및 역모델을 구하였다.

안드로이드 기반 교육용 IoT 스마트팜 구현에 관한 연구 (A Study on the Implementation of an Android-based Educational IoT Smartfarm)

  • 박세준
    • Journal of Platform Technology
    • /
    • 제9권4호
    • /
    • pp.42-50
    • /
    • 2021
  • 최근 고령화로 인한 농촌인구의 감소, 생산량 감소, 해외 농산물 유입 등 경쟁 심화문제를 해결하기 위해 스마트팜 도입의 필요성이 점점 커지고 있으며 이에 따라 교육에 대한 필요성이 증가하고 있다. 본 논문은 농장의 스마트팜 시스템을 축소하여 실제 환경에서도 사용이 가능하도록 안드로이드 기반 교육용 IoT 스마트팜 구현에 관한 연구이다. 교육용 IoT 스마트팜을 이용하여 안드로이드 기반 교육이 실제 환경에서 적용이 가능함을 확인하기 위해 블루투스, 와이파이, 서버/클라이언트 통신 방식을 사용하여 자동모드와 수동모드로 실험을 수행하였다. 자동모드는 모든 데이터를 수신하여 실시간으로 현재 상태를 확인할 수 있었으며, 수동모드는 수신된 센서데이터를 이용하여 실시간으로 명령을 전송하여 원격제어하였다. 실험 결과, 각 통신 방식의 특성을 파악할 수 있었고 안드로이드 앱을 이용한 스마트팜 원격 모니터링 및 원격 제어가 가능함을 확인하였으며, 안드로이드 기반 스마트팜 교육이 실제 환경에서 적용이 가능하리라 사료된다.

Novel Modular 3-phase AC-DC Flyback Converter for Telecommunication

  • Choi Ju-Yeop;Lee J.P.;Kim T.Y.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.314-320
    • /
    • 2001
  • A novel mode of parallel operation of a modular 3-phase AC-DC flyback converter for power factor correction along with tight regulation was recently analyzed and presented. The advantage of the proposed converter does not require expensive high voltage and high current devices that are normally needed in popular boost type 3-phase converter. In this paper the detailed small signal analysis of the modular 3-phase AC-DC flyback converter is provided for control purposes and also experimental results are included to confirm the validity of the analysis.

  • PDF

6고조파 주입 PWM을 이용한 3상 승압형 컨버터 고조파저감 (Harmonic Reduction in Three-Phase Boost Converter with Six Harmonic Injected PWM)

  • 이정훈;김재문;안정준;이정호;원충연;정동효
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.327-332
    • /
    • 1999
  • In this paper, six harmonic injection PWM method for reducing total harmonic distortion in single switch three phase discontinuous conduction mode boost converter is presented. In the proposed method, periodic six harmonic voltage is injected in the control circuit to vary the duty ratio of the converter switch within a line cycle so that the fifth order harmonic of the input current is reduced. Experimental results are verified by converter operating at 400V/6kW with three phase 140V~220V input.

  • PDF

음향 신호 분석에 의한 GMAW의 특성분석 (The Analysis of Characteristics of GMAW using Sound Signal)

  • 조택동;양상민;양성빈
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 춘계학술발표대회 개요집
    • /
    • pp.65-67
    • /
    • 2002
  • The gas metal arc welding(GMAW) is regarded as one of the best candidate for welding automation in industrial joining application. It is important to monitor the weld quality for the high performance of weld automation. The measured analog signal is frequency analyzed by digital signal process method. In order to observe the welding phenomena and control welding condition, arc light, voltage, and current are measured at the same time. They are analyzed and compared with arc sound. for these experiments, a power source of constant voltage characteristics was used in the pure metal transfer mode.

  • PDF

Design of Compact and Efficient Interleaved Active Clamp ZVS Forward Converter for Modular Power Processor Distributed Power System

  • Moon, Gun-Woo
    • Journal of Electrical Engineering and information Science
    • /
    • 제3권3호
    • /
    • pp.366-372
    • /
    • 1998
  • A high efficiency interleaved active clamp forward converter with self driven synchronous rectifiers for a modular power processor is presented. To simplify the gate drive circuits, N-P MOSFETs coupled active clamp method is used. An efficiency about 90% for the load range of 50-100% is achieved. The details of design for the power stage and current mode control circuit are provided, and also some experimental results are given.

  • PDF

평균전류모드제어를 이용하는 컨버터의 모델링 및 설계 (Modeling and Design of Average Current Mode Control)

  • 정영석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.442-444
    • /
    • 2005
  • 본 논문에서는 평균전류모드제어를 이용하는 컨버터의 연속시간 소신호 모델을 구한다. 평균전류모드제어에 일반적으로 사용되는 보상기를 적용한 컨버터의 해석을 위해 샘플러를 전류루프에 포함시켜 해석한다. 기존 모델에서는 정확히 해석하기 어려웠던 전류루프 이득의 고주파 영역 해석이 제안한 모델을 이용함으로써 쉽게 해결할 수 있으며, 시스템의 안정성을 결정하는 고주파 영역에서의 주파수 응답 특성을 제안한 모델이 우수한 성능으로 예측 가능함을 보인다.

  • PDF

비선형부하에 의해 발생한 전원 전류의 고조파를 제거하기 위한 단상 병렬형 Active Power Filter의 구현 (The Realization of a Single-Phase Parallel Active Power Filter to Eliminate Harmonics of Source Current Generated by Nonlinear Loads)

  • 장목순;이후찬;김상훈;박종연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.220-221
    • /
    • 2006
  • This paper presents a single-phase parallel active power filter with an analog control circuit to eliminate for harmonic source currents generated by nonlinear loads. The proposed system removes the harmonic source currents by injecting a compensation current that is 180' out of phase with the load harmonic current. The detection of the load harmonics is realized by a simple new structure, referred to the Notch Filter with GIC (Generalized Impedance Converter), which has higher Q than existing harmonic detecters and a simpler structure. The compensation current is obtained using the proposed harmonic detection circuit, DC-Link voltage, and output current of the full-bridge inverter controlled current mode PWM controller. The operation of the proposed system is verified experimentally.

  • PDF

All-optical Flip-flop Operation Based on Polarization Bistability of Conventional-type 1.55-㎛ Wavelength Single-mode VCSELs

  • Lee, Seoung-Hun;Jung, Hae-Won;Kim, Kyong-Hon;Lee, Min-Hee
    • Journal of the Optical Society of Korea
    • /
    • 제14권2호
    • /
    • pp.137-141
    • /
    • 2010
  • We report, for the first time to our knowledge, observation of polarization bistability from 1.55-${\mu}m$ wavelength single-mode VCSELs of a conventional cylinder-shape under control of their driving current, and demonstration of all-optical flip-flop (AOFF) operations based on the bistability with optical set and reset pulse injection at a 50 MHz switching frequency. The injection pulse energy was less than 14 fJ. The average on-off contrast ratio of the flip-flopped signals was about 7 dB. These properties of the VCSELs will be potentially useful for future high-speed all-optical signal processing applications.