• 제목/요약/키워드: Current Minimization

검색결과 236건 처리시간 0.023초

신뢰성에 기초한 철탑구조물의 최적화에 관한 연구 (Reliability-Based Structural Optimization of Transmission Tower)

  • 김성호;김상효;황학주
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1993년도 봄 학술발표회논문집
    • /
    • pp.135-140
    • /
    • 1993
  • The optimum weight design of structure is to determine the combination of structural members which minimize the weight of structures and satisfy design conditions as well. Since most of loads and design variables considered in structural design have uncertain natures, the reliability-based optimization techniques need to be developed. The aim of this study is to estabilish the general algorithm for the minimum weight design of transmission tower structure system with reliability constraints. The sequential linear programming method is used to solve non-linear minimization problems, which converts original non-linear programming problems to sequential linear programming problems. The optimal solutions are produced for various reliability levels such as reliability levels inherent in current standard transmission tower cross-section and optimal transmission tower cross-section obtained with constraints of current design criteria as well as selected target reliability index. The optimal transmission towers satisfying reliability constraints sustain consistent reliability levels on all members. Consequently, more balanced optimum designs are accomplished with less structural weight than traditional designs dealing with deterministic design criteria.

  • PDF

Performance optimization control of supersonic variable cycle engines

  • Tagashira, Takeshi;Sugiyama, Nanahisa
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.779-783
    • /
    • 2004
  • First this paper introduces an advanced FADEC (Full Authority Digital Electric Control) for current and future jet engines.It is designed to realize not only stable thrust control, but also performance improvement, reliability enhancement, service life extension, etc. It can be built by using current micro-processor with high computational power and there exists no difficulties but reliability problem of the micro- processor. Next, the simulation results of SFC minimization control are shown. The target engine is a supersonic, low-bypass ratio, 2-spool, combined cycle turbofan, designated as HYPR90T, which consists of a turbo engine for under Mach 3 flight and a ram engine for over Mach 3 flight. he results can then be used for performance optimization of the engine, which plays important role in the advanced FADEC.

  • PDF

전차선로-집전계 주행시험기 추진용 고속 선형동기전동기의 최적설계 (Optimal Design of a High-Speed Linear Synchronous Motor in a Dynamic Tester for Catenary Current Collection)

  • 이형우;권삼영;이병송;박현준
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.665-674
    • /
    • 2006
  • This paper presents the optimal design of a high-speed (200[km/h]) Linear Synchronous Motor which will be used as a propulsion system of a dynamic tester for catenary-current collection used in railways. Motor performance, especially detent force minimization on various design schemes has been investigated in detail by using FEM (Finite Element Method). Simulation-based DOE (Design of Experiments) method is also applied in order to reduce the large number of analysis according to each design variable and consider the effect among variables. The optimal design in all aspects is proposed by an optimization algorithm using a regression equation derived from the simulation-based DOE and the performance is verified by FEM.

  • PDF

비정현적인 역기전력을 가진 매입형 영구자석 동기전동기의 토크리플 저감에 관한 연구 (Torque Ripple Minimization for IPMSM with Non Sinusoidal Back-EMF)

  • 이상훈;홍인표;박성준;김철우
    • 전력전자학회논문지
    • /
    • 제7권1호
    • /
    • pp.91-100
    • /
    • 2002
  • 본 논문에서는 매입형 영구자석 동기전동기의 전자기 토크의 맥동저감에 관하여 기술하였다. 일반적으로 토크 맥동은 전동기의 진동과 소음을 유발하는 중요한 원인이 된다. 제안된 방법에서는 비정현적인 역기전력을 가진 IPMSM에서 토크 맥동을 저감하기 위해 단위전류당 최대토크 제어를 할 수 있는 최적의 전류 형상을 고려하여 도출하였다. 그리고 이를 전동기에 인가했을 때 토크 맥동이 개선될 수 있음을 시뮬레이션과 실험을 통해서 입증하였다.

선형 펄스 모터의 진동 감소를 위한 전류 파형의 설계 (Design of Current Waves for the Vibration Decrease of Linear Pulse Motor)

  • 조윤현;서진호;이권순
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권4호
    • /
    • pp.174-180
    • /
    • 2005
  • Linear pulse motor (LPM) has the vibration during the operation because of magnetic characteristic which is caused by the mechanical configuration and the electromagnetic property. This paper proposes the calculation of thrust on the base of magnetic equivalent circuit for the purpose of the vibration minimization of LPM. The permeance of LPM is calculated and simulated from the construction tooth. The thrust is compared with the analytical method, the 3D finite element method (FEM) and the experimental values. The vibration of LPM is measured and estimated to select the input current wave for an optimal operation condition.

Modulated Finite Control Set - Model Predictive Control for Harmonic Reduction in a Grid-connected Inverter

  • Nguyen, Tien Hai;Kim, Kyeong-Hwa
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.268-269
    • /
    • 2017
  • This paper presents an improved current control strategy for a three-phase grid-connected inverter under distorted grid conditions. Distorted grid condition is undesirable due to negative effects such as power losses and heating problem in electrical equipments. To enhance the power quality of distributed generation systems under such a condition, a modulated finite control set - model predictive control (MFCS-MPC) scheme will be proposed, in which the optimal switching signals of inverter are chosen by online basis using the principle of current error minimization. In addition, the moving average filter (MAF) is used to improve the phase-lock loop in order to obtain the harmonic-free reference currents on the stationary frame. The usefulness of the proposed MFCS-MPC method is proved by the comparative simulation results under different operating conditions.

  • PDF

An Economic Analysis of Potential Cost Savings from the Use of Low Voltage DC (LVDC) Distribution Network

  • Hur, Don;Baldick, Ross
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.812-819
    • /
    • 2014
  • The proposed technical work attempts to compare the two key technologies of power distribution, i.e. direct current (DC) and alternating current (AC) in a fiscal manner. The DC versus AC debate has been around since the earliest days of electric power. Here, at least four types of a low voltage DC (LVDC) distribution are examined as an alternative to the existing medium voltage AC (MVAC) distribution with an economic assessment technique for a project investment. Besides, the sensitivity analysis will be incorporated in the overall economic analysis model to cover uncertainties of the input data. A detailed feasibility study indicates that many of the common benefits claimed for an LVDC distribution will continue to grow more profoundly as it is foreseen to arise with the increased integration of renewable energy sources and the proliferation of energy storage associated with the enhanced utilization of uninterruptible power supply (UPS) systems.

Minimization of Torque Ripple for a Doubly Fed Induction Generator in Medium Voltage Wind Power System under Unbalanced Grid Condition

  • Park, Yonggyun;Suh, Yongsug;Go, Yuran
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.273-274
    • /
    • 2012
  • This paper investigates control algorithms for a doubly fed induction generator(DFIG) with a back-to-back three-level neutral-point clamped voltage source converter in medium voltage wind power system under unbalanced grid conditions. Two different control algorithms to compensate for unbalanced conditions are proposed. Evaluation factors of control algorithm are fault ride-through(FRT) capability, efficiency, harmonic distortions and torque pulsation. Zero regulated negative sequence stator current control algorithm has the most effective performance concerning FRT capability and efficiency. Ripple-free control algorithm nullifies oscillation component of active power and reactive power. Ripple-free control algorithm shows the least harmonic distortions and torque pulsation. Combination of zero regulated negative sequence stator current and ripple-free control algorithm control algorithm depending on the operating requirements and depth of grid unbalance presents the most optimized performance factors under the generalized unbalanced operating conditions leading to high performance DFIG wind turbine system.

  • PDF

접지저항 측정에 있어서 전류전극의 최소 이격거리 (Minimized Distance of the Current Electrode in the Measurement of Ground Resistance)

  • 이상무;강영흥;양준규
    • 조명전기설비학회논문지
    • /
    • 제20권10호
    • /
    • pp.68-73
    • /
    • 2006
  • 접지저항을 측정하는데 있어서 전류전극의 이격거리는 일반적으로 접지전극으로부터 전류전극에 이르기까지의 직선 구간상에서의 전압강하의 변화 곡선에 소위 평탄 구간이 존재하도록 이격하는 것으로 알려져 있다. 그러나 이러한 전류전극 이격 기준의 문제점은 그와 같은 조건을 만족하기에는 현실적으로 곤란한 측정 현장이 있다는 것이다. 이러한 문제의 보완을 위하여 본 논문은 실험적 측정 데이터를 활용, 분석하여 전류전극 이격거리의 최소 규격을 제시하였다. 분석 결과에 의하면 봉상접지에 대하여는 봉 길이의 2배 이상을, 메쉬접지에 대하여는 한 변 길이의 2배 이상 이격하여야 함을 알 수 있다.

Minimize Reactive Power Losses of Dual Active Bridge Converters using Unified Dual Phase Shift Control

  • Wen, Huiqing;Su, Bin
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.654-664
    • /
    • 2017
  • This paper proposed an unified dual-phase-shift (UDPS) control for dual active bridge (DAB) converters in order to improve efficiency for a wide output power range. Different operating modes of UDPS are characterized with respect to the reactive current distribution. The proposed UDPS has the same output power capability with conventional phase-shift (CPS) method. Furthermore, its implementation is simple since only the change of the leading phase-shift direction is required for different operating power range. The proposed UDPS control can minimize both the inductor rms current and the circulating reactive current for various voltage conversion ratios and load conditions. The optimal phase-shift pairs for two bridges of DAB converter are derived with respect to the comprehensive reactive power loss model, including the reactive components delivered from the load and back to the source. Simulation and experimental results are illustrated and explained with details. The effectiveness of the proposed method is verified in terms of reactive power losses minimization and efficiency improvement.