• 제목/요약/키워드: Current Limiting

검색결과 746건 처리시간 0.042초

2차회로의 수에 따른 하이브리드형 초전도 한류기의 동작 특성 (Characteristics of Hybrid-Type SFCL by the Number of Secondary Windings with YBCO Films)

  • 조용선;최효상;박형민
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권2호
    • /
    • pp.62-66
    • /
    • 2006
  • We investigated the characteristics of the hybrid-type superconducting fault current limiter (SFCL) by the number of secondary windings. The SFCL consists of a transformer, which has a primary winding and several secondary windings with serially connected $YB_{a2}Cu_{3}O_{7}$ films. In order to increase the capacity. of the SFCL, the serial connection between each current limiting unit is necessary. Resistive-type SFCL has a difficulty in quenching simultaneously between the units due to slight differences of their critical current densities. The hybrid-type SFCL could achieve the simultaneous quenching through the electrical isolation and the mutual flux linkage among the units. We confirmed that the capacity of the SFCL could be increased effectively through the simultaneous quenching among the units. In addition, the power burden of the system could be reduced by adjusting the number of secondary windings. We will investigate the method to increase the capacity through serial and Parallel connections among current limiting units.

Operational Characteristics of a Flux-Lock Type SFCL Integrated with Voltage-Controlled Voltage Source Inverter

  • Lee, Su-Won;Lim, Sung-Hun;Ko, Sung-Hun;Lee, Seong-Ryong
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권4호
    • /
    • pp.546-551
    • /
    • 2008
  • In this paper, a flux-lock type superconducting fault current limiter(SFCL) integrated with a voltage-controlled voltage source inverter(VC-VSI) is proposed. The suggested equipment, which consists of a flux-lock type SFCL and a VCVSI, can perform the fault current limiting operation from the occurrence of a short-circuit. In addition, it can compensate the reactive power that the non-linear load requires and also perform the uninterruptible power supply(UPS) as well as the load voltage stabilization by controlling the amplitude and the phase of the inverter's output voltage. The specification for a test model was determined and its various functions such as the fault current limiting and the power conditioning operations were presented and analyzed via computer simulation. Through the analytical results based on the computer simulation, the validity of the analysis was confirmed and its multi-operation was discussed.

고온초전도체를 이용한 자속구속 리액터의 사고시 발생되는 자계 분석 (Analysis for Magnetic field generated in the Flux-Lock Type Reactor using HTSC during a fault time)

  • 임성훈;최효상;강형곤;고석철;이종화;최명호;송재주;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.601-604
    • /
    • 2003
  • The magnetic field generated in the iron core, which is required for the magnetic field to link each coil of the flux-lock type reactor, affects the fault current limiting characteristics of the flux-lock type high-Tc superconducting fault current limiter(SFCL). By applying numerical analysis for equivalent circuit of flux-lock type SFCL, the magnetic field induced in the iron core including currents of each coil was investigated. Through the analysis of magnetic field, we have analyzed that the magnetic field linked the 3rd coil, which is wound in the iron core, prevents the saturation of the iron core, but decreases the impedance of the flux-lock type SFCL.

  • PDF

정보통신기기용 과도이상전압 고속도차단장치의 설계 및 제작 (Design and Fabrication of a High Speed Blocking Device of Transient Overvoltages for info-communication Facilities)

  • 길경석
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권1호
    • /
    • pp.51-56
    • /
    • 1999
  • This paper presents a new transient overvoltage blocking device (TOBD) for info-communication facilities with low power and high frequency bandwidth. Conventional protection devices have some problems such as low frequency bandwidth, low energy capacity and high remnant voltage. In order to improve these limitations, thehybrid type TOBD, which consists of a gas tube, avalanche diodes and junction typefield effect transistors (JFETs), was designed and fabricated. The TOBD differs from the conventional protection devices in configuration, and JFETs were used as an active non-linear element and a high speed switching diode with low capacitance limits high current. Therefore the avalanche dilde with low energy capacity are protected fromthe high current, and the TOBD has a very small input capacitance. From the performance test using combination surge generator, which can produce $1.2/50\mus\;4.2kV_{max}\; 8/20\mus\; 2.1kA_{max}$, it is confirmed that proposed TOBD has an excellent protection performance in tight clamping voltage and limiting current characteristics.

  • PDF

자속구속형 고온초전도 전류제한기 동작 특성 (Operational characteristic of flux-lock type HTSC-FCL)

  • 임성훈;최효상;강형곤;고석철;이종화;최명호;송재주;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 기술교육전문연구회
    • /
    • pp.20-23
    • /
    • 2003
  • The operational characteristics of flux-lock type high-Tc superconducting fault currentlimiters(HTSC-FCLs) was described and currents equation at each coil was derived from equivalent circuit. $YBa_{2}Cu_{3}O_{7-x}$(YBCO) thin film was used as the current limiting elements of the flux-lock type HTSC-FCL, which were fabricated by etching the YBCO thin film into 2 mm wide and 420 mm long meander line consisting of foureen stripes with different length. The 2nd peak on the current of coil 2 after a fault disappeared by current of the 3rd winding, which was installed in the flux-lock type HTSC-FCL.

  • PDF

Electrodialysis with a channeled stack for high strength cadmium removal from wastewater

  • Kyung Jin, Min;Hyo Jin, An;Ah Hyun, Lee;Hyun-Gon, Shin;Ki Young, Park
    • Membrane and Water Treatment
    • /
    • 제14권1호
    • /
    • pp.47-54
    • /
    • 2023
  • In this study, high concentrations of cadmium-containing wastewater were treated by electrodialysis (ED) with a channel stack. The limiting current density (LCD), cadmium removal efficiency, and current efficiency were investigated under each experimental condition according to the Reynolds number (Re), membrane area, and pH. With the increase in the film area to 111, 333, 555, and 777 cm2 at Re (109.1), LCDs decreased to 408.11, 44.45, 35.32, and 13.64 A/m2, respectively. The highest cadmium removal efficiency (99.6%) and current efficiency were obtained for the membrane area of 111 and 777 cm2, respectively. Under changing Re in the pH range of 1 to 4, Re and LCD were proportional under the same pH condition, and pH and LCD tended to be inversely proportional under the same Re condition. Cadmium removal rate was the best at the pH range 3 - 4. It has been found that ED with channeled stacks can be successfully applied to treat wastewater containing high concentrations of cadmium.

타입에 따른 무유도 권선형 코일의 한류 특성연구 및 자장해석 (A study on the current limiting characteristics and magnetic analysis of the non-inductively wound coil)

  • 장재영;박동근;장기성;나진배;김원철;정윤도;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권1호
    • /
    • pp.25-29
    • /
    • 2009
  • To reduce the power loss in normal state, non-inductively wound high temperature superconducting (HTS) coils are used for fault current limiter (FCL) application. Non-inductively wound coils can be classified into two types: solenoid type and pancake type. These two types have different electrical and thermal and mechanical characteristics due to their winding structure difference. This paper deals with the current limiting characteristics, magnetic field analysis of the two coils. Simulation using finite element method (FEM) was used to analyze the magnetic field distribution and inductance of the coils. Short circuit test using stabilizer-free coated conductor (CC) was also carried out. We can compare the characteristics of the two types of coil by using the data obtained from simulation and short circuit test. We confirmed the feasibility of FCL application by the analysis about the characteristics of non-inductively wound coil using CC.

종속 접속된 전압제한형 서지방호장치의 에너지협조 (Energy Coordination of Cascaded Voltage Limiting Type Surge Protective Devices)

  • 이복희;신희경
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.29-35
    • /
    • 2013
  • For the purpose of designing and applying optimum surge protection, one of the essential points is to take into account the energy coordination between cascaded surge protective devices(SPDs) and it is important to obtain an acceptable sharing of the energy stress between two cascaded SPDs. In this paper, in case of two voltage-limiting SPDs connected in parallel, the amount of splitting impulse current and energy that flow through each SPDs is investigated as a function of the protective distance. As a result, the energetic coordination between cascaded SPDs is strongly dependent on the voltage protection level of SPDs and the protective distance. It was confirmed that the sharing of the energy between two cascaded SPDs and the limited voltage levels are appropriate when the voltage protection levels of both upstream and downstream SPDs are the same.

$96.5{\mu}W$ 소비 전력을 갖는 리미팅 증폭기 설계 (Desing of the $96.5{\mu}W$ Limiting Amplifier using low power technique)

  • 최문호;이종수;강지희;김영석
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.521-522
    • /
    • 2008
  • This paper presents fully integrated low power consumption limiting amplifier. The proposed limiting amplifier is employed folded cascode structure with source degeneration output stage. This proposed structure demands few transconductance than conventional structure. It can be dramatically decrease current consumption. The total power consumption is only $96.5\;{\mu}W$ under a 1.8 V supply voltage in 9.5 dB limited gain condition. It was designed in using $0.18\;{\mu}m$ CMOS technology.

  • PDF

절연유-절연지에서 이중 임피던스에 의해 부분방전측정 (Partial Discharge Measurement of Oil-Paper Insulation by Dual Measuring Impeadance)

  • 김광화;류희석;선종호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1778-1780
    • /
    • 1996
  • In this paper, we describe the partial discharge measurement with measuring impedance to have two wide frequency band transformers(filters) in the oil-paper and air insulation. The measuring impedance consists of high and low limiting frequency transformers. This measuring impedance could be measured the partial discharge current wave. We have the results that the amplitude partial discharge pulse ratio of low limiting frequency tranformer to high limiting frequency one is varied in the condition(in oil-paper insulation and air) to generate partial discharge.

  • PDF