• Title/Summary/Keyword: Current Interruption

Search Result 203, Processing Time 0.027 seconds

The Mediation Effect of the Work-Family Spillover between Full-time Married Working Women's Inefficient Working Culture and Career Interruption Intention (비효율적 업무문화와 경력단절의도와의 관계에서 일-가정 전이의 매개효과: 전일제 기혼 여성근로자를 대상으로)

  • Park, Cheong-Yeul;Shon, Young-Mi;Shin, Kyu-Lee
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.8
    • /
    • pp.280-292
    • /
    • 2015
  • The current study examines the mediation effect of the work-family spillover between full-time married working women's inefficient working culture and career interruption intention. The mediation effect is tested by classifying the work-family spillover effect into two subfactors: the work-family conflict and the work-family facilitation. For this purpose, we sampled 281 full-time married working women aged between 30 and 50s and conducted a hierarchical regression analysis. The main results are as follows: both work-family conflict and work-family facilitation play the role of partial mediation. This finding implies that it is necessary to carefully examine the effects of subfactors for work-family spillover to married working women's career interruption.

Effects of Grid Characteristics on High Speed Circuit Breaker for Railway Vehicle (철도 차량용 직류 고속도 차단기의 그리드 특성 해석)

  • Park, Ji-Won;Jung, Jooyoung;Choi, Jinnil
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.2
    • /
    • pp.117-123
    • /
    • 2016
  • High speed circuit breakers(HSCB) interrupt the generated arc within the arc chute to turn off the electricity flowing through the main circuit to prevent ground faults. In order to explore the arc generated from the contactor operation, arc definition, establishment of arc interruption method, and analysis of magnetic driving force are required. In this paper, arc interruption capability has been estimated by exploring the difference in magnetic flux density of Lorenz forces using finite element analysis. In addition, since the number of grids and changes in the grid shape within the arc chute influence the formation of the inner magnetic field, its effects have been explored to enhance arc interruption capability. Assessment of interruption capability and analysis of grid shape, with rated operating current, are reported.

IGBT DC Circuit Breaker with Paralleled MOV for 1,800V DC Railway Applications (직류 철도용 MOV 병렬연결 1,800V급 IGBT 직류 고속차단기 연구)

  • Han, Moonseob;Lee, Chang-Mu;Kim, Ju-Rak;Chang, Sang-Hoon;Kim, In-Dong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.12
    • /
    • pp.2109-2112
    • /
    • 2016
  • The rate of rise of the fault current in DC grids is very high compared to AC grids because of the low line impedance of DC lines. In AC grids the arc of the circuit breaker under current interruption is extinguished by the zero current crossing which is provided naturally by the system. In DC grids the zero current crossing must be provided by the circuit breaker itself. Unlike AC girds, the magnetic energy of DC grids is stored in the system inductance. The DC circuit breaker must dissipate the stored energy. In addition the DC breaker must withstand the residual overvoltage after the current interruption. The main contents of this paper are to ${\cdot}$ Explain the theoretical background for the design of DC circuit breaker. ${\cdot}$ Develop the simulation model in PSIM of the real scaled DC circuit breaker for 1,800V DC railway. ${\cdot}$ Suggest design guidelines for the DC circuit breaker based on the experimental work, simulations and design process.

Calculation of Pressure Rise in the Puffer Cylinder of EHV GCB Without Arc (무부하시의 초고압 GCB의 파퍼실린더 내부의 상승압력 계산)

  • Park, K.Y.;Song, K.D.;Choi, Y.K.;Shin, Y.J.;Song, W.P.;Kang, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1559-1561
    • /
    • 1994
  • At present, the principle of puffer action in high current interruption is adopted in almost of the EHV(Extra High Voltage) and UHV(Ultra High Voltage) GCB(Gas Circuit Breakers). The thermal interruption capability of these GCBs critically depends on the pressure rise in the puffer cylinder at current zero. The pressure rise in the puffer cylinder depends on the puffer cylinder volume, flow passage and leakage area in the interrupter, stroke curve etc. Recently commercial CFD(Computational Fluid Dynamics ) packages have been widely adopted to calculate the pressure distribution in the interrupter. However, there are still several problems with it, e.g. very expensive price, moving boundary problem, computation time, difficulty in using the package etc. Thus, the calculation of the puffer cylinder pressure in simple and relatively correct method is essential in early stage of GCB design. In these paper, the model ing technique and computed results for EHV class GCB (HICO, 145kV 40kA and 362kV 40kA GCB) are presented and compared with available measured results.

  • PDF

전력계통 고장전류 저감을 위한 한류기술 및 초전도 저항형 한류기 개발 동향 분석

  • 이방욱;강종성;박권배;오일성
    • Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.10-17
    • /
    • 2003
  • For limitation and interruption of short circuit currents from low voltage to extra high voltage applications, the electrical equipment including fuses and circuit breakers, are widely used today. But in order to anticipate increasing needs for effective and competitive device for limiting the growing fault current in electrical power systems, fault current limitation technologies and fault current limitation devices are widely introduced and investigated in these days. Furthermore, the applications of high temperature superconducting materials (HTSC) into the current limiting devices are new approach for developing of novel and effective col-rent limitation electrical equipment. In this research, the necessities of current limitation technology and the developed and developing current limitation devices for power systems are introduced. Finally, the investigation of resistive type fault current limiters which is under development by LG and KEPCO were introduced.

  • PDF

AFCI algorithm design without sensor (센서없는 AFCI 알고리즘 설계)

  • Ban, Gi-Jong;Choi, Sung-Dai;Ho, Yoon-Kwang;Kim, Sang-Hoon;Nam, Moon-Hyon;Kim, Lark-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.231-233
    • /
    • 2006
  • Arc Fault Current is an electric discharge which is occurred in two opposite electrode. In this paper, arc current control algorithm is designed for the interruption of arc fault current which is occurred in the low voltage network. This arc is one of the main causes of electric fire. General arc current sensor has troubles for detecting arc currents, thus we would like to propose the arc current detection method without current sensor. In this paper, arc discharge currents within power lines are being detected through the arc current control algorithm.

  • PDF

The Characteristic Study for Small Current Breaking of High Speed DC Circuit Breaker (직류고속도차단기의 소전류 차단 특성연구)

  • Min Byung-Hoon;Jang Woo-Jin;Ko In-Suk
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.8
    • /
    • pp.396-402
    • /
    • 2006
  • Even the case DC circuit Breaker have good quality for interruption of high current like heavy load current, short-circuit current, the verification for small current breaking capability of circuit breaker should be performed. It comes from the reason DC small current breaking failure can be lead to break out second heavy fault condition and in the long run substation shutdown. In this paper, we can find the characteristics of DC small current and international test standard discription about small current breaking and one of the proper solution to get over it.

Interruption analysis of the SFCL-combined DC circuit breaker system using current-limiting technology

  • Kim, Jun-Beom;Jeong, In-Sung;Choi, Hye-Won;Choi, Hyo-Sang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.4
    • /
    • pp.30-34
    • /
    • 2016
  • In this study, a SFCL-combined DC circuit breaker system was proposed by applying the current-limiting technology for DC circuit breaking. The SFCL-combined circuit breaker system consists of a mechanical DC circuit breaker combined with superconductors. To ensure the reliable structure and operation of the SFCL-combined circuit breaker system, a simulation grid was designed using the EMTDC/PSCAD program, and simulation was conducted. The results showed that the SFCL-combined DC circuit breaker system with superconductors limited the maximum fault current by 37%. In addition, the burden on the DC circuit breaker was decreased by 87%.

Operating characteristics of high Tc superconducting current limiting fuse at various voltages (고온 초전도 한류퓨즈의 전압별 동작특성)

  • Choi, Hyo-Sang;Hyun, Ok-Bae;Kim, Hye-Rim;Hwang, Si-Dole;Park, Kwon-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.161-163
    • /
    • 2001
  • We present the basic properties of a superconducting current limiting fuse (SCLF) based on YBCO/Au films. The SCLFs consists of YBCO stripes covered with Au layers for current shunt. Under the source voltage of 100 $V_{rms}$, the longer the duration time of fault current was, the shorter its discharge time was. The duration time of fault current and its discharge time were reduced by increased voltages in the range of 200 - 300 $V_{rms}$. We thought that this was because the quench propagation was limited by local melting generated with higher voltage.

  • PDF

Mathematical Modelling of $SF_6$ Puffer Circuit Breakers II : Current Zero Region ($SF_6$ 파퍼차단기의 수학적 모델링 II : 영전류 영역)

  • Park, K.Y.;Shin, Y.J.;Chang, K.C.;Song, K.D.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1661-1664
    • /
    • 1994
  • In designing $SF_6$ puffer circuit breakers, analyzing are behavior during current zero region and thermal recovery characteristics after current interrupt ion is very important. In this paper, a mathematical are model based on the integral method has been based to analyze them. The pressure rise in the puffer chamber and the distributions of pressure, density, velocity and enthalpy inside nozzle are calculated and analyzed at current zero region. The influence of fault current magnitude and change of di/dt at current zero on the interruption capability of puffer circuit breakers is investigated. Finally, the calculated results are compared with the available results from experiment.

  • PDF