• Title/Summary/Keyword: Current Fed Inverter

Search Result 210, Processing Time 0.023 seconds

New PWM Technique for Two-Phase Brushless DC Motor Drives

  • Lin, Hai;Kwon, Byung-Il
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1107-1115
    • /
    • 2013
  • A new PWM technique for a two-phase BLDC motor fed by a two-phase eight-switch inverter is proposed in this paper. It is well known that a two-phase eight-switch inverter can significantly improve power output compared with a two-phase six-switch inverter in a two-phase motor drive. To drive the two-phase BLDC motor simply and effectively, two normal PWM strategies are investigated to manage speed regulation. However, under the conditions of low speed and light load, especially during the braking process, the current in a short time of one period is near zero, which is a discontinuous waveform every half period. To solve it, a novel PWM technique is investigated to improve the operational performance of normal technique. Using the new PWM scheme, the current continues every half period and the braking performance is improved. The effectiveness of the proposed PWM method is verified through the experiments.

Characteristics of Two Phase Operation of Two Winding Motor Driven by Reference Current Adaptive Inverter (기준전류추정형 인버어터에 의한 2 권선전동기의 2 상운전특성)

  • 원종수;정의상
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.8
    • /
    • pp.289-298
    • /
    • 1984
  • The single phase induction motor is recently requested to meet a broad speed control and smooth forward and reverse operation due to the multifarious usages. This paper deals with two phase operation of a two winding motor by reference current adaptive inverter which can supply the currents to satisfy the balanced oeration into the main and auxiliary winding through the entire operational region. According to the roposed system, the starting, forward and reverse and variable speed control of a two winding motor eliminated the capacitor from the capacitor-run motor is also possible. The formation and its principle of the reference current adaptive inverter and characteristic analysis of the motor fed by this apparatus are described in this paper. Excellent agreement with the measured results and calculated values by computer simulation is obtained.

  • PDF

Current-Source Pulse Density Modulated Parallel Resonant Inverter with A Single Resonant Snubber and Its Unique Application

  • Wang Y.X.;Koudriavtsev O.;Konishi Y.;Okuno A.;Nakaoka M.;Lee H.W.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.261-265
    • /
    • 2001
  • In this paper, a current-source type parallel indudor compensated load resonant high-frequency soft switching inverter using IGBTs for driving the newly-produced silent discharge type ozone generating tube and excimer lamp for UV generation which incorporate a single switched capacitor resonant snubber between the port in DC busline side is presented, together with its pulse modulated unique output power regulation characteristics.

  • PDF

Suppression of high frequency leakage current in PWM Inverter-Fed Induction Motor Drives using Active Common Mode Voltage Damper (능동형 커먼 모드 전압 감쇄기를 통한 유도 전동기의 고주파 누설전류 억제)

  • 홍순일
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.186-190
    • /
    • 2000
  • This paper propose a "Active common-mode voltage damper circuit" that capable of a suppression of a common-mode voltage produced in the PWM VSI. The four level half-bridge PWM inverter circuit and common-mode transformer are incorporated into the "Active common-mode voltage damper" the design method of which is presented Effect of "Active common-mode voltage damper" in this paper verifies a propriety and effectiveness in 2.2[kW] induction motor drive using IGBT inverter. Experimental results show that "common-mode voltage damper" makes contributions to reducing a high frequency leakage current and common-mode voltage.leakage current and common-mode voltage.

  • PDF

A Study on Reduction of Current Ripple due to Commutation in Brushless DC motor (브러시리스 직류전동기의 전환에 의한 전류 맥동 저감에 관한 연구)

  • Lee, Gwang-Un;Park, Jeong-Bae;Yeo, Hyeong-Gi;Yu, Ji-Yun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.9
    • /
    • pp.490-497
    • /
    • 1999
  • This paper presents a novel current control method to reduce the current ripple due to commutation in brushless DC motor fed with unipolar PWM voltage source inverter. The proposed current control method can reduce the current ripple due to commutation in high speed range where the DC link voltage of the inverter is less than four times of the phase back-emf. The effectiveness of the proposed current control method is verified with digital simulations and experiments on the 250W brushless DC motor drive systems.

  • PDF

A Study on the Novel Time Sharing Type Current Fad High Frequency Resonant Inverter (새로운 시분할 방식 전류형 고주파 인버터에 관한 연구)

  • Kim H.J.;Won J.S.;Kang J.W.;Cho G.P.;Oh S.H.;Min B.J.;Jung D.Y.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.27-30
    • /
    • 2003
  • This paper describes two novel current fed high frequency resonant inverter can be used as the power supp]y for wax-sealing. This two topology can be obtained higher output frequency than switching frequency by composing modified unit inverter based on conventional half-bridge serial resonant inverter in parallel with input power source. also, By using time-sharing gate control method, this proposed inverter can not only realize the output control of dependence irrespective of the switching frequency using phase-shift but also reduce switching loss because it has ZVS function. Simulation results through the Pspice have demonstrated the feasibility of the proposed inverter. This proposed inverter will be able to be practically used as a power supply in various fields as induction heating applications, DC-DC converter etc.

  • PDF

Diagnosis Methods for IGBT Open Switch Fault Applied to 3-Phase AC/DC PWM Converter

  • Im, Won-Sang;Kim, Jang-Sik;Kim, Jang-Mok;Lee, Dong-Choon;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.120-127
    • /
    • 2012
  • Fault diagnosis technique of electrical drives is becoming more and more important, since voltage fed converter system has become industrial standard in many applications. Many studies have been conducted an inverter fault diagnosis for induction motors. However, there are few researches about fault diagnosis of 3-phase ac/dc PWM (Pulse Width Modulation) converter compared to the dc/ ac inverter. The ac/dc converter is the opposite of dc/ac inverter at current flow. Also, inverter and converter have different current patterns under the same condition of IGBT (Insulated gate bipolar transistor) open switch fault. Therefore, it is difficult to apply intact diagnosis methods of inverter to the converter. This paper proposes modified fault detection methods for IGBT open switch fault in 3-phase ac/dc PWM converter by modifying established fault diagnostic methods for dc/ac inverters.

Analysis of Optimized Injection Method for Active Power Filter of Current Injection Type (전류주입식 능동전력 필터를 위한 최적주입방법의 해석)

  • 박민호;최규하
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.35 no.7
    • /
    • pp.296-303
    • /
    • 1986
  • The active filter of current injection type is the device which eliminates the harmonics in ac line by injecting the harmonic compensating current into the ac side. And its harmonic reduction performance is entirely dependent on the control scheme of the current-fed inverter and the harmonic compensating current becomes the PWM wave by the inverter. This PWM compensating current can be determined by selecting the switching function properly which eliminates the harmonics up to any order with using no independent sources. The new injection current model is derived by the proposed method which is called the optimized injection method. The overall characteristics of the proposed method are investigated through digital computation and the feasibility is proved with experimental results obtained from the Z-80 microcomputer control of the active filter.

  • PDF

Reduction of Torque Ripple due to Current-Sensing Errors in Inverter-Fed AC Motor Systems (인버터의 전류측정 오차에 기인하는 교류전동기의 토크리플 저감)

  • 윤덕용;홍순찬
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.280-286
    • /
    • 1998
  • This paper proposes a novel method to reduce the torque ripple due to the non-ideality of the current sensing parts in vector-controlled inverter-fed AC motor drive systems. For PMSM(Permanent Magnet Synchronous Motor), motor output torque equations are derived in terms of their offset voltages and different voltage transducing gains. And the effects of phase current errors on motor torque are analyzed for both salient PMSM and non-salient PMSM. The proposed method can eliminate the torque ripple by nulling the offset voltages and setting the voltage transducing gains to the same value. To verify the proposed method, digital simulations are carried out for non-salient PMSM.

  • PDF

Bus Clamping PWM Based Hysteresis Current Controlled VSI Fed Induction Motor Drive with Nearly Constant Switching Frequency

  • Peter, Joseph;Mohammed Shafi, KP;Ramchand, Rijil
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1523-1534
    • /
    • 2017
  • A Current Error Space Phasor (CESP) based hysteresis controller with online computation of the boundary for two-level inverter fed Induction Motor (IM) drives is presented in this paper. The stator voltages estimated along the ${\alpha}$-and ${\beta}$-axes and the orthogonal current error components of the motor are used in the online computation of the hysteresis boundary. All of the inherent benefits of space phasor based hysteresis controllers such as its quick dynamic response and nearby voltage vector switching are present in the proposed scheme with the added benefit of suppressing switching frequency variations. The similarity in the frequency spectrum of the phase voltage obtained at the output of the inverter using the proposed scheme and Bus Clamping Pulse Width Modulation (BCPWM) based drive is justified with the help of extensive MATLAB SIMULINK simulations. The controller is experimentally verified with a three phase, 2.2 kW IM drive for steady state and transient conditions and the obtained results match the simulation results.