Reduction of Torque Ripple due to Current-Sensing Errors in Inverter-Fed AC Motor Systems

인버터의 전류측정 오차에 기인하는 교류전동기의 토크리플 저감

  • 윤덕용 (천안공업대학 제어계측과) ;
  • 홍순찬 (단국대 공대 전기공학과)
  • Published : 1998.12.01

Abstract

This paper proposes a novel method to reduce the torque ripple due to the non-ideality of the current sensing parts in vector-controlled inverter-fed AC motor drive systems. For PMSM(Permanent Magnet Synchronous Motor), motor output torque equations are derived in terms of their offset voltages and different voltage transducing gains. And the effects of phase current errors on motor torque are analyzed for both salient PMSM and non-salient PMSM. The proposed method can eliminate the torque ripple by nulling the offset voltages and setting the voltage transducing gains to the same value. To verify the proposed method, digital simulations are carried out for non-salient PMSM.

본 논문에서는 벡터제어방식의 인버터에 의하여 구동되는 교류전동기 제어 시스템에서 전류특정회로에서의 측정오차에 기인하는 전동기의 토크리플을 저감하는 방법을 제안한다. 2상의 전류를 측정하는 회로에서의 오프셋 전압과 전압증폭률이 서로 다를 때 전동기 출력토크에 발생되는 리플을 각각 정량적으로 분석하고, 이로부터 온라인 상태에서 실시간으로 토크리플을 제거할 수 있는 알고리즘을 제시하였다. 제안된 방식의 유용성을 확인하기 위하여 이를 영구자석형 동기전동기에 적용하였을 경우에 대하여 출력토크의 리플을 계산하고 이를 제거하는 알고리즘을 컴퓨터로 시뮬레이션하였다.

Keywords

References

  1. IEEE Trans. on Ind. Appl. v.IA-25 no.2 Modelling, Simulation, and Analysis of Permanent-Magnet Motor Drives, Part Ⅰ: The Permanent-Magnet Synchronous Motor Drive P. Pillay;R. Krishnan
  2. Electrical Machines and Drives, A Space-Vector Theory Approach Peter Vas
  3. 단국대학교 공학박사학위논문 공간전압벡터 PWM 기법을 이용한 영구자석형 동기전동기의 속도제어 윤덕용
  4. Proceedings of ICEE '96 Torque Ripple Reduction in Synchronous Motor Systems Driven by an Inverter S. C. Hong;D. Y. Yoon;E. Y. Won