• Title/Summary/Keyword: Curing agent

Search Result 428, Processing Time 0.022 seconds

The comparison of microtensile bond strength with immediate and delayed dentin sealing (즉시 상아질 봉쇄와 지연 상아질 봉쇄에 따른 상아질 접착의 미세인장 결합강도 비교)

  • Lee, Heung-Bae;Han, Chong-Hyun;Shim, Jun-Sung;Kim, Sun-Jai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.4
    • /
    • pp.372-380
    • /
    • 2008
  • Purpose: The purpose of this study was to evaluate the effect of various methods of dentin bonding agent application on microtensile bond strength between dentin and resin, using a 2-step etch-and-rinse dentin bonding agent. Material and methods: Twenty freshly extracted human molars were obtained and divided into 4 groups of 5 teeth. 2-step etch-and-rinse dentin bonding agent was used for all groups. The control specimens were prepared using a direct immediate bonding technique. The delayed dentin sealing (A, C) specimens were prepared using an indirect approach with delayed dentin sealing. For group A, resin was built-up on uncured dentin bonding agent, and for group C, resin was built-up on pre-cured dentin bonding agent. Preparation of the immediate dentin sealing (B) specimens also used an indirect approach with immediate dentin sealing immediately following preparation. All teeth were prepared for a microtensile bond strength test. Specimens were stored in water for 24 hours. Ten beams (1.0 ${\times}$ 1.0 ${\times}$ 11 mm) from each tooth were selected for testing. Bond strength data (MPa) were analyzed with a one-way ANOVA test, and post hoc comparison was done using the Scheffe's test. Results: The mean microtensile bond strengths of control group, B and C (DDS with pre-cure) were not statisticaaly different from each other at 32.7, 33.3, 34.2 MPa. the bond strength for group A (DDS without pre-cure), 19.5 MPa, was statistically different (P < .01) from the other 3 groups. Conclusion: When preparing teeth for indirect bonded restorations, DDS with pre-curing dentin bonding agent and IDS results in the same bond strength between dentin and resin. On the contrast, the bond strength was decreased when DDS without pre-curing dentin bonding agent was used.

A Comparative Study on Polyurethane Coating Films Prepared Using 4,4'-Methylenebis(2-chloroaniline) and 1,3-Propanediolbis(4-aminobenzoate) as Crosslinking Agents (4,4'-Methylenebis(2-chloroaniline)과 1,3-Propanediolbis(4-aminobenzoate)를 가교제로 사용하여 제조한 폴리우레탄 코팅 필름의 특성 비교)

  • Lee, Youn-Sik;Lee, Sung-Il;Kim, Duk-Bae;Park, Young-Deok;Kim, Jung-Kee;Hahn, Yoon-Bong;Nahm, Kee-Suk
    • Elastomers and Composites
    • /
    • v.39 no.1
    • /
    • pp.71-76
    • /
    • 2004
  • 4,4'-Methylenebis(2-chloroaniline)(MOCA) has been widely used as a crosslinking agent, but classified as a toxic chemical. Thus, its use will be limited in the near future. In this research, polyurethane coating films were prepared using 1,3-propanediolbis(4-aminobenzoate)(PDBA) as an alternative to MOCA. The base part was prepared by melting MOCA or PDBA in polyoxypropylene($M_n$=2000), followed by the addition of the various additives. The NCO-terminated toluene diisocyanate prepolymer was used as a curing agent. The polyurethane coating films were prepared by mixing the base part with the curing agent in an appropriate ratio at room temperature. The polyurethane coatings prepared using PDBA exhibited higher initial viscosity, but much longer pot lift, compared to those prepared using MOCA under the same conditions, due to lower reactivity of PDBA. The tensile strength and tear strength of the coating films were much weaker. However, the pot life, tensile strength, elongation, and tear strength of the coating films, prepared using PDBA in the presence of an increased amount of Pb(II)-octoate, were close to those of the coating films prepared using MOCA. Thus, it was concluded that PDBA can substitute MOCA in the preparation of polyurethane coatings as long as the reactivity of PDBA is enhanced using appropriate amounts of the catalyst or other appropriate catalyst.

Changes of Physicochemical Parameters During the Aerobic Composting Process of Swine Manure (돈부의 호기성 퇴비화 단계별 물리.화학적 성상 변화)

  • 김태일;정광화;최기춘;류병희;곽정훈;전병수;박치호;김형호;한정대
    • Journal of Animal Environmental Science
    • /
    • v.3 no.1
    • /
    • pp.13-18
    • /
    • 1997
  • This study was conducted to investigate the physicochemical changes during the aerobic composting of swine manure mixed with bulking agent, sawdust(v/v, 1:1), in a full-scale composting plant using rectangular escalator-aginated bed composting system. Physical and chemical properties were analyzed on the samples which were collected at 5, 15, and 25 day of composting, curing and final step. The results of this study were summarized as follows; 1. Moisture and K2O content, and pH of final step were higher than those of 5th day of composting (p<0.05). 2. Ammonium nitrogen, total organic corbon and organic matter content, and electrical conductivity(EC) were significantly decreased (p<0.05) but nitrate nitrogen, ash and P2O5 content increased(p<0.05) throughout the aerobic composting process. 3. Total organic carbon per total nitrogen(C/N) and total organic matter per total nitrogen(OM/N) ratio were significantly decreased throughout the aerobic composting process(p<0.05). 4. Physical and chemical properties of swine manure were varied by aerobic fermentation using rectangular escalor-aginated bed composting system.

ECO Characteristic of ATH - Filled XLPE Compound Composites (환경친화적 ATH - FILLED XLPE COMPOUND 특성 연구)

  • Jung, Young-Seub;Kim, Kyung-Yong;Han, Sien-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05e
    • /
    • pp.44-48
    • /
    • 2003
  • 할로겐 난연재료 및 고분자의 연소시 Dioxine의 문제점이 대두되고 있어 유럽국가를 중심으로 할로겐 난연제 사용을 규제하고 있다. 환경과 인체에 대한 안정성을 고려해서 저 유해 가스화, 저 발연화, 저 부식성, 리사이클링 등을 겸비한 제품의 개발로 관심이 모아지고 있는 실정이다. 본 연구에서는 환경친화적인 금속화합(수산화 알루미늄)을 사용하여 연소시 발생할 수 있는 난연성, 무독성, 소연성 등을 함량별로 확인하고 난연재가 증가할수록 취약한 기계적 물성 보완을 위해 moisture cure crosslikable 기술로 케이블절연 및 자켓 피복층 특성을 증가 시켰다. 그러나 수산화알루미늄 함량이 증가할수록 기계적 물성과 기타 특성도 감소하는 경향을 보이고 있어 최적의 난연제 조성함량이 약 130~150 phr정도에서 우수한 결과를 확인하였다. 또한 moisture cure agent는 전선압출 시 표면에 scorch 및 장기 압출에 영향을 주므로 약 1.5~2phr 범위에서 처방하는 것이 우수하다. 원료투입 후 mixing 공정 중에서는 온도관리가 매우 중요하므로 되도록 믹싱 온도를 $130^{\circ}C$ 이하를 유지해야한다. 온도는 수산화알루미늄의 분산성과 케이블 피복압출 시 표면에도 영향을 주기 때문이다 본 연구는 이런 작업방법을 통해 친환경 가교 난연콤파운드가 비(比) 가교된 제품에 비해 특성이 증가되는 것을 입증할 수 있었다.

  • PDF

Mechanical properties of TiO2/epoxy resin nanocomposites

  • Ahn, Seok-Hwan;Nam, Ki-Woo;Moon, Chang-Kwon
    • Journal of Power System Engineering
    • /
    • v.17 no.5
    • /
    • pp.69-77
    • /
    • 2013
  • The purpose of this study is to improve the properties of epoxy resin using the big-sized titanium oxide nanoparticles. The effects of particle weight fraction and shape of sample on the thermal and mechanical properties in titanium oxide reinforced epoxy resin has been investigated. In addition, the effect of particle dispersion situation on the mechanical properties of nanocomposites has been studied. As a result, the Tg was almost same regardless of the content of nanoparticles. Storage modulus increased up to the content of 3wt% particles and then decreased. Tensile strength and modulus of film-shaped sample with 1wt% was higher than the one of pure epoxy, while other composites were not. The tensile strength of dogbone-shaped sample with 1wt% was only higher than the one of pure epoxy, while other composites were lower than the one of pure epoxy. Tensile modulus of dogbone-shaped samples increased with the content of particles.

Evaluation of the physical properties and antibacterial effects on Candida albicans of denture base resin containing silver sulfadiazine (실버 설파다이아진이 첨가된 의치상용 레진의 Candida albicans에 대한 항균평가 및 물성 평가)

  • Yu-Ri Choi;Min-Kyung Kang
    • Journal of Korean society of Dental Hygiene
    • /
    • v.23 no.6
    • /
    • pp.459-466
    • /
    • 2023
  • Objectives: The purpose of this study was to evaluate the physical properties and antibacterial activity of denture base resin with added silver sulfadiazine. Methods: Specimens were made from self-curing denture base resin and silver sulfadiazine as an inorganic antibacterial agent. For physical evaluation of the specimens, surface roughness, surface hardness, and contact angle were measured. Bacterial growth was assessed by optical densityat 600 nm (OD600) and colony forming units (CFU) measurements to confirm antibacterial activity. Results: There was no significant difference in surface roughness, surface hardness, and contact angle in the experimental group containing silver sulfadiazine compared to the control group. In contrast, the experimental group showed a significant decrease in antibacterial activity compared to the control group in terms of OD value. Analysis of CFU confirmed a significant decrease in colonies in the experimental group compared to the control group. Conclusions: Denture base resin containing silver sulfadiazine, an inorganic antibacterial agent, exhibited enhanced antibacterial activity without physical changes. In conclusion, the use of denture base resin containing inorganic antibacterial agents may be expected in the future.

Strength Development of Sulfur-Polymer-Based Concrete Surface Protecting Agents Depending on Curing Condition and Hazard Assessment of Sulfur Polymers (유황폴리머를 활용한 콘크리트 표면보호재의 양생조건에 따른 강도 평가 및 유황폴리머의 유해성 평가)

  • Lee, Byung-Jae;Lee, Eue-Sung;Kim, Seung-Gu;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.1
    • /
    • pp.139-146
    • /
    • 2015
  • The amount of by-product from sulphur increases in domestic industrial facilities. However, the amount of its consumption is limited so that the amount of unused sulphur continues to increase. Therefore, in this study, the use sulfur polymer as the concrete surface protecting material was conducted. The compressive strength showed that as the substitution ratio of filler increased up to 40%, the compressive strength also increased. A high compressive strength was shown at the curing temperature of $40^{\circ}C$ (SS, FA) and $60^{\circ}C$ (OPC) according to the type of filler. The difference of compressive strength between air dry curing and water curing was insignificant so that there was no significant influence of moisture during curing process. The evaluation result of bond strength showed that the highest bond strength was shown at the air-dry condition of $40^{\circ}C$ regardless of type of filler. Bonding didn't occur properly during water curing in comparison to air dry curing. Also, in case of the specimen cured at $60^{\circ}C$, discoloration and hair cracks appeared due to the influence of temperature, and the highest bond strength was shown at the substitution ratio of 20% (SS, FA) and 30% (OPC) according to the type of filler. The releasing test result of harmful substance showed that no harmful substance was released, so there is no harmfulness in the surface protecting material using sulfur polymer. As a conclusion drawn in this study, it is most appropriate to substitute silica by approximately 20%, mix and cure at the air-dry condition of $40^{\circ}C$ in order to use sulfur polymer as the surface protecting material.

Shear bond strength of dentin bonding agents cured with a plasma arc curing light (전단접착강도와 관련된 Plasma Arc Curing Light의 중합효율평가)

  • Kwon, Young-Chul;Kim, Sun-Young;Chung, Sae-Joon;Han, Young-Chul;Lee, In-Bog;Son, Ho-Hyun;Um, Chung-Moon;Cho, Byeong-Hoon
    • Proceedings of the KACD Conference
    • /
    • 2008.05a
    • /
    • pp.213-223
    • /
    • 2008
  • The objective of this study was to compare dentin shear bond strength (DSBS) of dentin bonding agents (DBAs) cured with a plasma arc (PAC) light curing unit (LCU) and those cured with a light emitting diode (LED) LCU. Optical properties were also analyzed for Elipar freelight 2 (3M ESPE); LED LCU, Apollo 95E (DMT Systems); PAC LCU and VIP Junior (Bisco); Halogen LCU. The DBAs used for DSBS test were Scotchbond Multipurpose (3M ESPE), Singlebond 2 (3M ESPE) and Clearfil SE Bond (Kuraray). After DSBS testing, fractured specimens were analyzed for failure modes with SEM. The total irradiance and irradiance between 450 nm and 490 nm of the LCUs were different. LED LCU showed narrow spectral distribution around its peak at 462 nm whereas PAC and Halogen LCU showed a broad spectrum. There were no significant differences in mean shear bond strength among different LCUs (P > 0.05) but were significant differences among different DBAs (P < 0.001).

  • PDF

Shear bond strength of dentin bonding agents cured with a plasma arc curing light (전단접착강도와 관련된 Plasma Arc Curing Light의 중합효율평가)

  • Kwon, Young-Chul;Kim, Sun-Young;Chung, Sae-Joon;Han, Young-Chul;Lee, In-Bog;Son, Ho-Hyun;Um, Chung-Moon;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.3
    • /
    • pp.213-223
    • /
    • 2008
  • The objective of this study was to compare dentin shear bond strength (DSBS) of dentin bonding agents (DBAs) cured with a plasma arc (PAC) light curing unit (LCU) and those cured with a light emitting diode (LED) LCU. Optical properties were also analyzed for Elipar freelight 2 (3M ESPE); LED LCU, Apollo 95E (DMT Systems); PAC LCU and VIP Junior (Bisco); Halogen LCU. The DBAs used for DSBS test were Scotchbond Multipurpose (3M ESPE), Singlebond 2 (3M ESPE) and Clearfil SE Bond (Kuraray). After DSBS testing, fractured specimens were analyzed for failure modes with SEM. The total irradiance and irradiance between 450 nm and 490 nm of the LCUs were different. LED LCU showed narrow spectral distribution around its peak at 462 nm whereas PAC and Halogen LCU showed a broad spectrum. There were no significant differences in mean shear bond strength among different LCUs (P > 0.05) but were significant differences among different DBAs (P < 0.001)

Dentin bond strength of bonding agents cured with Light Emitting Diode (LIGHT EMITTING DIODE로 광조사한 상아질 접착제의 상아질 전단접착강도와 중합률에 관한 연구)

  • Kim Sun-Young;Lee In-Bog;Cho Byeong-Hoon;Son Ho-Hyun;Kim Mi-Ja;Seok Chang-In;Um Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.6
    • /
    • pp.504-514
    • /
    • 2004
  • This study compared the dentin shear bond strengths of currently used dentin bonding agents that were irradiated with an LED (Elipar FreeLight, 3M-ESPE) and a halogen light (VIP, BISCO). The optical characteristics of two light curing units were evaluated. Extracted human third molars were prepared to expose the occlusal dentin and the bonding procedures were performed under the irradiation with each light curing unit. The dentin bonding agents used in this study were Scotchbond Multipurpose (3M ESPE), Single Bond (3M ESPE), One-Step (Bisco), Clearfil SE bond (Kuraray), and Adper Prompt (3M ESPE), The shear test was performed by employing the design of a chisel-on-iris supported with a Teflon wall. The fractured dentin surface was observed with SEM to determine the failure mode. The spectral appearance of the LED light curing unit was different from that of the halogen light curing unit in terms of maximum peak and distribution. The LED LCU (maximum peak in 465 nm) shows a narrower spectral distribution than the halogen LCU (maximum peak in 487 nm). With the exception of the Clearfil SE bond (P < 0.05), each 4 dentin bonding agents showed no significant difference between the halogen light-cured group and the LED light-cured group in the mean shear bond strength (P > 0.05). The results can be explained by the strong correlation between the absorption spectrum of camphoroquinone and the narrow emission spectrum of LED.