• Title/Summary/Keyword: Ct value

Search Result 995, Processing Time 0.026 seconds

Research on the Reduction of Exposure Dose of a Patient Having a PET/CT Exam (PET/CT 검사 환자의 피폭선량 경감을 위한 연구)

  • Kim, Bong-Su;Pyo, Sung-Jai;Cho, Yong-Gyi;Shin, Chai-Ho;Cho, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.10-16
    • /
    • 2009
  • Purpose: As the number of patients has increased since the installation of a PET/CT, we are now examining about 2500-3000 annually. We have realized that if we properly adjust a pitch under the same condition of a CT during a PET/CT exam, radiation quantity that reaches the patient can change. In order to reduce the exposure dose of a patient, the research examines a method of reducing the exposure dose of a patient by controlling the pitch during a PET/CT exam, viewing whether the adjustment of the pitch influences CT image and PET SUV. Methods: The equipment used is a Biograph Positron Emission Tomography (PET) Scanner (CT type: TRCT-240-130 (WCT-240-130)) of Siemens company. For the evaluation of exposure dose of a patient, we measured radiation quantities using a PTW-DIADOS 11003/1383, which is a CT radiation measurement instrument used by Siemens. We measured and analyzed the space resolutions of CT images caused by the change of pitches using an AAPM Standard Phantom in order to see how the adjustment of pitches influenced the CT images. In addition, in order to obtain SUVs caused by each change of pitches using a PET source made with a solid radioactive cylinder phantom, we confirmed whether the SUVs changed in the PET/CT images by calculating the SUVs of the fusion images caused by the change of pitches after obtaining CT and PET images and finishing the test. Results: 2slice CT scanner showed that radiation quantities largely dropped when pitches ranged from 0.7 to 1.3 and that the reduction of radiation quantities were smaller when pitches ranged from 1.5 to 1.9. That is, we found that the bigger pitch values are the smaller the radiation quantities of a patient are. Moreover, we realized that there is no change of SUVs caused by the increase of pitches and that pitch values do not influence PET SUVs and the quality of CT images. It is judged that using 1.5 as a pitch value contributes to the reduction of exposure dose of a patient as long as there is no problem in the quality of an image. Conclusions: When seeing the result of the research, hospital using a PET/CT should make an effort to reduce the exposure dose of a patient seeking pitch values appropriate for their hospital within the range in which there is no image distortion and PET SUVs are not influenced from pitches. We think that the research can apply to all multi-detectors having a CT scanner and that such a research will be needed for other equipments in the future.

  • PDF

Role of FDG-PET in the Diagnosis of Recurrence and Assessment of Therapeutic Response in Cervical Cancer and Ovarian Cancer Patients: Comparison of Diagnostic Report between PET, Abdominal a and Tumor Marker (자궁경부암 및 난소암 환자 재발진단과 치료반응평가에 있어서 FDG-PET의 역할: 양전자방출단층촬영, 복부전산화단층촬영 및 종양표지자 판독의 비교 분석)

  • Han, You-Mie;Choe, Jae-Gol;Kang, Bung-Chul
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.3
    • /
    • pp.201-208
    • /
    • 2008
  • Purpose: We aimed to assess the role of positron emission tomography using fluorodeoxyglucose (FDG-PET) in the diagnosis of recurrence or the assessment of therapeutic response in cervical and ovarian cancer patients through making a comparison between FDG-PET, abdominal computed tomography (CT) and serum tumor marker. Materials and methods: We included 103 cases (67 patients) performed FDG-PET and abdominal CT. There were 42 cervical cancers and 61 ovarian cancers. We retrospectively reviewed the interpretations of PET and CT images as well as the level of tumor marker. We calculated their sensitivity, specificity, positive predictive value and negative predictive value for these three modalities. And then we analyzed the differences between these three modalities. Results: Tumor recurrences were diagnosed in 37 cases (11 cervical cancers and 26 ovarian cancers). For PET, CT and tumor marker, in cervical cancer group, sensitivity was 100% (11/11), 54.5% (6/11) and 81.1% (9/11), respectively. And specificity was 93.6% (29/31), 93.6% (29/31) and 100% (31/31). In ovarian cancer group, sensitivity was 96.2% (25/26), 84.6% (22/26) and 80.8% (21/26), and specificity was 94.3% (33/35), 94.3% (33/35), 94.3% (33/35), PET was highly sensitive to detect the intraperitoneal and extraperitoneal metastasis with the help of the CT images to localize the lesions. However, CT had limitations in differentiation of the recurrent tumor from benign fibrotic tissue, identification of viable tumors at the interface of tissues, and detecting extraperitoneal lesions. Conclusion: FDG-PET can be an essential modality to detect the recurrent or residual tumors in gynecologic cancer patients because of its great field of the application and high sensitivity.

The Effect of Intravenous Contrast on SUV Value in $^{18}F$-FDG PET/CT using Diagnostic High Energy CT (진단용 고선량 CT를 이용한 $^{18}F$-FDG PET/CT 촬영시 정맥 조영제가 SUV 값에 미치는 영향)

  • Jeong, Young-Jin;Kang, Do-Young
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.3
    • /
    • pp.169-176
    • /
    • 2006
  • Purpose: According to the development of CT scanner in PET/CT system, the role of CT unit as a diagnostic tool has been more important. To improve the diagnostic ability of CT scanner, it is a key aspect that CT scanning has to be performed with high dose energy and intravenous (IV) contrast. So we investigated the effect of IV contrast media on the maximum SUV (maxSUV) of normal tissues and pathologic lesions using PET/CT scanner with high dose CT scanning. Materials & Methods: The study enrolled 13 patients who required PET/CT evaluation. At first, the patients were performed whole body non-contrast CT (NCCT-120 kVp, 130 mAs) scan. Then contrast enhanced CT (CECT) scan was performed immediately. Finally PET scan was followed. The PET omission data were reconstructed twice, once with the NCCT and again with the CECT. We measured the maxSUV of 10 different body regions that were considered as normal in ail patients. Also pathologic lesions were investigated. Results: There were not seen focal artifacts in PET images based on CT with IV contrast agent. Firstly, 130 normal regions in 13 patients were evaluated. The maxSUV was significantly different between two PET images (p<0.00)). The maxSUV was $1.1{\pm}0.5$ in PET images with CECT-corrected attenuation and $1.0{\pm}0.5$ in PET images with NCCI-corrected attenuation. The limit of agreement was $0.1{\pm}0.3$ in Bland-Altman analysis. Especially there were significant differences in 6 of 10 regions, apex and base of the right lung, ascending aorta, segment 6 & segment 8 of the liver and spleen (p<0.05). Secondly, 39 pathologic lesions were evaluated. The maxSUV was significantly different between two PET images (p<0.001). The maxSUV was $4.7{\pm}2.0$ in PET images with CECT-corrected attenuation and $4.4{\pm}2.0$ in PET images with NCCT-corrected attenuation. The limit of agreement was $0.4{\pm}0.8$ in Bland-Altman analysis. Conclusion: Although there were increases of maxSUVs in the PET images based on CT with IV contrast agent, it was very narrow in the range of limit of agreement. So there was no significant effect to clinical interpretation for PET images that were corrected attenuation with high dose CT using IV contrast.

The Usefulness of Deconvolution Perfusion CT in Patients with Acute Cerebral Infarction : Comparison with Diffusion MRI (급성 뇌경색 환자에서 Deconvolution perfusion CT의 유용성 : Diffusion MRI와 비교)

  • Eun, Sung-Jong;Kim, Young-Keun
    • Journal of radiological science and technology
    • /
    • v.26 no.3
    • /
    • pp.25-31
    • /
    • 2003
  • This study was performed to evaluate the usefulness of Deconvolution perfusion CT in patients with acute cerebral infarction. Nine patients with acute cerebral infarction underwent conventional CT and cerebral perfusion CT within 23 hours of the onset of symptoms. The perfusion CT scan for each patient was obtained at the levels of basal ganglia and 1cm caudal to the basal ganglia. By special imaging software, perfusion images including cerebral blood volume(CBV), cerebral blood flow(CBF), and mean transit time(MTT) maps were created. The created lesions were evaluated on each perfusion maps by 3 radiolocical technician. MTT delay time was measured in the perfusion defect lesion and symmetric contralateral normal cerebral hemisphere. Lesion sire were measured on each perfusion map and compared with the value obtained by diffusion weighted MR imaging(DWMRI). All perfusion CT maps showed the perfusion defect lesion in all patients. There were remarkable CT delay in perfusion defect lesion. In comparison of lesion size between each perfusion map and DWMRI, the lesion on CBF map was the most closely correlated with the lesion on DWMRI(7/9). The size of perfusion defect lesion on MTT map was larger than that of lesion on DWMRI, suggesting that m map can evaluate the ischemic penumbra. Deconvolution Perfusion CT maps make it possible to evaluate not only ischemic core and ischemic penumbra but also hemodynamic status in perfusion defect area. These results demonstrate that perfusion CT can be useful to the diagnosis and treatment in the patients with acute cerebral ischemic infarction.

  • PDF

Evaluation of Image for Phantom according to Normalization, Well Counter Correction in PET-CT (PET-CT Normalization, Well Counter Correction에 따른 팬텀을 이용한 영상 평가)

  • Choong-Woon Lee;Yeon-Wook You;Jong-Woon Mun;Yun-Cheol Kim
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.1
    • /
    • pp.47-54
    • /
    • 2023
  • Purpose PET-CT imaging require an appropriate quality assurance system to achieve high efficiency and reliability. Quality control is essential for improving the quality of care and patient safety. Currently, there are performance evaluation methods of UN2-1994 and UN2-2001 proposed by NEMA and IEC for PET-CT image evaluation. In this study, we compare phantom images with the same experiments before and after PET-CT 3D normalization and well counter correction and evaluate the usefulness of quality control. Materials and methods Discovery 690 (General Electric Healthcare, USA) PET-CT equiptment was used to perform 3D normalization and well counter correction as recommended by GE Healthcare. Based on the recovery coefficients for the six spheres of the NEMA IEC Body Phantom recommended by the EARL. 20kBq/㎖ of 18F was injected into the sphere of the phantom and 2kBq/㎖ of 18F was injected into the body of phantom. PET-CT scan was performed with a radioacitivity ratio of 10:1. Images were reconstructed by appliying TOF+PSF+TOF, OSEM+PSF, OSEM and Gaussian filter 4.0, 4.5, 5.0, 5.5, 6.0, 6,5 mm with matrix size 128×128, slice thickness 3.75 mm, iteration 2, subset 16 conditions. The PET image was attenuation corrected using the CT images and analyzed using software program AW 4.7 (General Electric Healthcare, USA). The ROI was set to fit 6 spheres in the CT image, RC (Recovery Coefficient) was measured after fusion of PET and CT. Statistical analysis was performed wilcoxon signed rank test using R. Results Overall, after the quality control items were performed, the recovery coefficient of the phantom image increased and measured. Recovery coefficient according to the image reconstruction increased in the order TOF+PSF, TOF, OSEM+PSF, before and after quality control, RCmax increased by OSEM 0.13, OSEM+PSF 0.16, TOF 0.16, TOF+PSF 0.15 and RCmean increased by OSEM 0.09, OSEM+PSF 0.09, TOF 0.106, TOF+PSF 0.10. Both groups showed a statistically significant difference in Wilcoxon signed rank test results (P value<0.001). Conclusion PET-CT system require quality assurance to achieve high efficiency and reliability. Standardized intervals and procedures should be followed for quality control. We hope that this study will be a good opportunity to think about the importance of quality control in PET-CT

  • PDF

Clinical Value of Cardiovascular Calcifications on Non-Enhanced, Non-ECG-Gated Chest CT (비 조영증강 비 심전도동기 흉부 CT에서 발견되는 심혈관계 석회화의 임상적 가치)

  • Tae Seop Choi;Hwan Seok Yong;Cherry Kim;Young Joo Suh
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.2
    • /
    • pp.324-336
    • /
    • 2020
  • Cardiovascular calcifications can occur in various cardiovascular diseases and can serve as a biomarker for cardiovascular event prediction. Advances in CT have enabled evaluation of calcifications in cardiovascular structures not only on ECG-gated CT but also on non-ECG-gated CT. Therefore, many studies have been conducted on the clinical relevance of cardiovascular calcifications in patients. In this study, we divided cardiovascular calcifications into three classes, i.e., coronary artery, thoracic aorta, and cardiac valve calcifications, which are closely associated with cardiovascular events. Further, we briefly described pericardial calcifications, which can be found incidentally. Since the start of lung cancer screening in Korea in the second half of 2019, the number of non-enhanced, non-ECG-gated, low-dose chest CT has been increasing, and the number of incidentally found cardiovascular calcifications has also been increasing. Therefore, understanding the relevance of cardiovascular calcifications on non-enhanced, non-ECG-gated, low-dose chest CT and their proper reporting are important for radiologists.

An Evaluation of Fracture Toughness for SS400 Steel by R-curve and DCPD (R-곡선과 직류전위차(DCPD)에 의한 SS400강의 파괴인성 평가)

  • Jang Seok-Ki;Han Min-Su
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.8
    • /
    • pp.855-861
    • /
    • 2005
  • Fracture toughness defined near the initiation of stable crack growth is investigated by R-curve and Direct Current electric Potential Determination(DCPD) under mode I plane strain conditions for CT specimen with 25.4mm thickness of SS400 steel. Fracture toughness. $J_{IC}$lit near crack tip of CT specimen by R-curve is 17.14 $kg_{f}/mm$ and however. its value by DCPD is 22.82 $Rg_{f} mm$ The value of fracture toughness by DCPD is larger than that by R-curve. Therefore, it is suggested that the evaluation of fracture toughness by R-curve is optimum than by DCPD, when considering amount of crack growth about each of fracture toughness.

Value of Bone Scan in Addition to F-18 FDG PET/CT and Characteristics of Discordant lesions between F-18 FDG PET/CT and Bone Scan in the Spinal Bony Metastasis (척추골전이에 있어 F-18 FDG PET/CT에 대한 골스캔의 추가적 역할 및 F-18 FDG PET/CT와 골스캔간에 불일치 병소에 대한 연구)

  • Jun, Sung-Min;Nam, Hyun-Yeol;Kim, In-Ju;Kim, Yong-Ki;Kim, Ju-Sung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.3
    • /
    • pp.218-228
    • /
    • 2008
  • Purpose: Our purpose was to evaluate spinal bony metastasis which could be missed on an F-18 FDG PET/CT (FDG PET/CT) alone, and to characterize discordant metastatic lesions between FDG PET/CT and bone scan. Material and Methods: FDG PET/CT and bone scans of 43 patients with spinal bony metastasis were analyzed retrospectively. A McNemar test was performed comparing the FDG PET/CT alone to the FDG PET/CT plus bone scan in the spinal bony metastases. A one-way chi-square test was performed to characterize the metastases that were missed on the FDG PET/CT alone. To evaluate discordant lesions between FDG PET/CT and bone scan, we performed logistic regression analyses. The independent variables were sites (cervical, thoracic, and lumbar), size (large and small), and maximum SUVs, and the dependant variable was bone scan uptake (positive and negative MDP uptake). Results: A significant difference was found between the FDG PET/CT alone and the FDG PET/CT combined with the bone scan (p < 0.01). Using the FDG PET/CT only, diffuse osteoblastic metastasis was missed with a significantly higher frequency (p = 0.04). In the univariate analysis, cervical vertebra and small size were related to negative MDP uptake, and thoracic vertebra and large size were related to positive MDP uptake. However, in the multivariate analysis, only the large size was related to positive MDP uptake. Conclusion: A bone scan in addition to the FDG PET/CT increased the ability to evaluate spinal bony metastases, especially for diffuse osteoblastic metastasis. Large metastasis was related to positive bone scan uptake in spinal bony metastasis.

Implementation of Medical Diagnostic Information System and Conformance Test of Medical Image in Mobile Environment (모바일 환경에서 의료 진단 정보 시스템의 구현 및 의료 영상의 적합성 평가)

  • Cho, Chung-Ho;Kim, Gwang-Hyun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.6
    • /
    • pp.713-720
    • /
    • 2015
  • As the hand-held mobile devices are widely used, they are recently coming into convergence with medical diagnostic systems. Furthermore, the wireless mobile Internet and the various kinds of communication devices are rapidly coming into wide use converging with medical technology. The mobile communication environments can make people get more health care services beyond space and time. In this paper, we implement and evaluate the mobile client and the medical diagnostic information server for transmitting, searching and updating the medical diagnostic information. The DICOM CT image and the compressed JPEG 2000 CT image are statistically evaluated by t-test performance whether those images are clinically appropriate. In the case of the DICOM CT image, we realize that the average value is relatively more appropriate to the clinical diagnosis than the JPEG 2000 CT image.

Correlation Analysis Between Narrowing Disc Space of Lumbar X-ray and HIVD of L-spine CT in Lumbosacral Strain Patients (좌섬요통환자에서 X-ray상 narrowing과 CT상 HIVD와의 연관성 분석)

  • Kim, Eun-young;Kim, Young-wook;Lee, Kyung-min;Kim, Ju-youn;Kim, Hyo-eun;Kang, Young-hwa;Seo, Jung-chul;Lim, Sung-chul;Han, Sang-won
    • Journal of Acupuncture Research
    • /
    • v.19 no.6
    • /
    • pp.125-133
    • /
    • 2002
  • Objective : This study was designed to analyze the of correlation between narrowing disc space of lumbar X-ray and HIVD of L-spine CT in lumbosacral strain patients. Methods : 63 cases of lumbosacral strain patients who visited Bul-kyooh Oriental Hospital from June 13, 2000 to August 9, 2001 were selected. We performed the radiography by lumbar X-ray and L-spine CT for all cases. Results : 28 of 63 cases revealed narrowing disc space in Lumbar X-ray and these 28 cases were diagnosed as HIVD in L-spine CT at all. 35 of 63 cases revealed normal in Lumbar X-ray and 13 of these 35 cases were diagnosed as HIVD in L-spine CT. Conclusions : We found that narrowing disc space in lumbar X-ray has significant relevance to HIVD in L-spine CT(P-value = 0.001). For accurate diagnosis and treatment of lumbosacral strain patients. combination of clinical symptoms, physical examination and radiography of X-ray and HIVD is needed.

  • PDF