• Title/Summary/Keyword: Cross-sectional Comparative Study

Search Result 102, Processing Time 0.024 seconds

Comparison of Muscle Architecture of Lower Extremity using Rehabilitative Ultrasound Image in Young Adults: a Comparative Study of Muscle Cross-sectional area of Lower Extermity of Seoul and Hanoi in Vietnam (재활 초음파 영상을 이용한 젊은 성인의 하지 근 구조 비교: 서울과 하노이 하지 근 단면적비교 연구)

  • Lee, Hwang-Jae;Kim, Min-Kyu;Ha, Hyun-Geun;Lee, Wan-Hee
    • The Journal of Korean Physical Therapy
    • /
    • v.26 no.5
    • /
    • pp.324-330
    • /
    • 2014
  • Purpose: The aim of the current study was to compare the muscle architecture of lower extremity using rehabilitative ultrasound imaging (RUSI) in young adults in Seoul and Hanoi. Methods: The study design was a comparative study of muscle cross-sectional area of lower extremity. Sixty healthy young subjects (Seoul group: 30, Hanoi group: 30) participated in this study. Real-time B-mode RUSI with a 7.5MHz linear transducer was used for measurement of cross-sectional area, pennation angle, and muscle thickness of the rectus femoris, tibialis anterior, and medial gastrocnemius muscles. Independent t-test was used for statistical analysis. Results: Significant difference in cross sectional area of rectus femoris was observed between Korean young adults and Hanoi young adults (p<0.01). Muscle thickness and pennation angle of tibialis anterior in Korean young adults were greater than in Hanoi young adults (p<0.01). In addition, the muscle thickness and pennation angle of the medial part of gastrocnemius muscle were greater in Korean young adults than in Hanoi young adults (p<0.01). In addition, in the results for gender, men had larger muscle architectures than women in both groups (p<0.01). Conclusion: This study, using RUSI, showed significant difference in muscle architectures of lower extremity in a diverse group of young adults RUSI.

Analysis of Actual Cross-Sectional Area During Scanning According to MRI Bore Size (MRI 보어 구경에 따른 검사 시 실효 단면적 분석)

  • Jeong, Hyunkeun;Jeong, Hyundo;Kim, Seongho;Jeon, Mincheol;Yoo, Sejong;Ko, Hyuncheol;Cho, Yonghyun
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.219-227
    • /
    • 2020
  • In this study, we tried to quantify the actual cross-sectional area inside the bore when scanning by the MRI system with various bore sizes. To this end, a comparative analysis was conducted by both of blueprint of each MRI equipment and actual measurement in the field. As a result of analysis, ACSA(Actual Cross-Sectional Area) in Ingenia CX, Elition X, uMR 780, Omega, Vida, Lumina, Architect, Premier is recorded as 171230, 232150, 242100, 309332, 230760, 230760, 229380 and 235990 ㎟, respectively ACSA% was 60.6, 60.3, 73.0, 70.0, 60.0, 60.0, 59.6, and 61,3%. In addition, DTB (Distance from Table top to Bore top) recorded 400, 407, 445, 495, 405, 405, 405, 403, and 412 mm. Through this study, it was confirmed that there is a difference between the bore size according to each MRI system and the actual cross-sectional area during MRI scanning. Accordingly, if we consider the internal actual area just not bore size at the clinical site, useful diagnostic images can be obtained in the end with better convenience.

Quality Assessment of Non-randomised Comparative Clinical Studies in The Journal of Korean Acupuncture and Moxibustion Society ($\ll$대한침구학회지\gg$에 실린 중재 관련 비무작위 비교연구논문의 질적 평가)

  • Seon, Jong-In;Baek, Yong-Hyeon;Lee, Sang-Hoon;Lee, Jae-Dong
    • Journal of Acupuncture Research
    • /
    • v.27 no.1
    • /
    • pp.109-116
    • /
    • 2010
  • Objectives : Since The Journal of Korean Acupuncture and Moxibustion Society(JKAMS) started publishing in 1984, randomised controlled trials(RCTs) and non-randomised clinical studies(NRSs) consistently have increased in quality and quantity. There has been no study on quality assessment of NRSs. Thus, this study evaluted non-randomised comparative clinical trials in the JKAMS to assess the quantity and quality. Methods : Upon extracting NRSs for assessing the intervention effects from all the articles published in the JKAMS from 1984 to 2009, assessments were made on methodological index for non-randomised studies(MINORS). Also, the analysis were made upon the proportion of non-randomised comparative clinical trials within original articles. The mean scores by research methods and years, and total scores and mean scores of yearly research methods were analyzed. Results : A total of 44 trials on non-randomised comparative clinical trials were selected. In 1980s, 4.3% of the total selected original articles, in 1990s, 4.1%, and in 2000s 14.2% were NRSs. According to the research designs, the mean scores of MINORS were Case-control study 18.3, Controlled before and after 18.5, Quasi randomised trial 18.5, and non randomised trial 17.9(out of 24), respectively. Cross-sectional study was the most frequently used(41.9%). Conclusion : Although NRSs consistently increased in quantity, the assessed mean scores were low and most articles used Cross-sectional study. Thus, there should be studied using appropriate research methods in the future.

Comparative Analysis between Directly Measured Diameter in 2D Angiography and Cross-Sectional Area-Converted Diameter in MR Image (2D 혈관조영술에서 직접 측정한 혈관 직경과 MR 영상에서 단면적 기반 환산 직경의 비교 분석)

  • Ki-Baek Lee;Mi-Hyeon Kim
    • Journal of radiological science and technology
    • /
    • v.46 no.5
    • /
    • pp.427-433
    • /
    • 2023
  • This study aimed to quantitatively compare the diameters measured directly from the coronal plane or sagittal plane of 2D digital subtraction angiography (DSA) and the cross-sectional area-converted diameters calculated from contrast-enhanced MR (CE-MR) imaging. A retrospective analysis was conducted on 20 patients who underwent both 2D DSA and CE-MR imaging. Firstly, the venous diameters of the superior sagittal sinus (SSS) and transverse sinus (TS) were directly measured from 2D DSA. Subsequently, the axial planes for SSS diameter and the sagittal plane for TS in CE-MR imaging were utilized to calculate cross-sectional area-based converted diameters. The numerical values obtained from 2D DSA and CE-MR imaging were compared pairwise at each location. For SSS, the diameter measured by 2D DSA was 27% larger than the conversion-based diameter from CE-MR imaging (9.8±1.4 mm vs. 7.1±1.3 mm, P<0.05). Similarly, for the right TS, the difference was 16% (8.8±3.2 mm vs. 7.4±2.0 mm, P<0.05), and for the left TS, the difference was 22% (8.4±2.8 mm vs. 6.6±1.3 mm, P<0.05). In conclusion, the diameter measured directly in conventional 2D DSA may be larger than the diameter converted based on the cross-sectional area. Therefore, when selecting the size of the stent, it is crucial to make precise determinations while keeping this fact in mind.

Chronic Respiratory Symptoms and Associated Factors among Fruit and Vegetable Workers in Addis Ababa, Ethiopia: A Comparative Cross sectional Study

  • Mulualem Gete Feleke;Yidnekachew Alemu;Meaza Gezu Shentema;Samson Wakuma;Zerihun Emiru;Tesfaye Yitna Chichiabellu
    • Safety and Health at Work
    • /
    • v.14 no.3
    • /
    • pp.287-294
    • /
    • 2023
  • Background: Fruit and vegetable market is an abundant source of bioaerosols. Exposure to organic and inorganic waste and long-term inhalation of bioaerosols during working hours leads to chronic respiratory symptoms. Hence, this study aimed to determine the prevalence of chronic respiratory symptoms and related factors among fruit and vegetable workers compared with the control group in Addis Ababa, Ethiopia. Methods and materials: A comparative cross-sectional study was conducted from 2020 to 2021. Data were entered in EpiData 3.1 and exported to Statistical Package for the Social Sciences (SPSS) version 25. Logistic regressions were computed to depict the data and related factors. The culture method was done to count and compare bacterial and fungal concentrations between fruit and vegetable workers and office workers. Results: In this study, the prevalence of chronic respiratory symptoms (PR = 2.87, 95% confidence interval [CI]: 1.772-4.66) was significantly higher among fruit and vegetable workers (46.7%) than controls (23.4%). Sex (adjusted odds ratio [AOR] = 2.11, 95% CI = 1.12-3.98), educational status (AOR = 1.34, 95% CI = 0.78-2.32), working hours per day (AOR = 3.91, 95% CI = 1.586-9.65), and working department (AOR = 3.20, 95% CI = 0.90-11.40) were associated with chronic respiratory symptoms. Bacterial and fungal concentrations were significantly higher in the air of the vegetable market (276 colony-forming unit) than the air in the workplace of controls (7 colony-forming unit). Conclusion: The fruit and vegetable market workers (greengrocers) had a higher prevalence of chronic respiratory symptoms relative to office workers. Respiratory protective devices should be given to deliver preventive measures.

COMPARATIVE STUDY ON MORPHOLOGY OF CROSS-SECTION AND CYCLIC FATIGUE TEST WITH DIFFERENT ROTARY NITI FILES AND HANDLING METHODS (수종의 NiTi 전동 파일 단면 형태 비교 및 pecking motion의 사용방법이 피로 파절에 미치는 영향)

  • Kim, Jae-Gwan;Kum, Kee-Yeon;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.2
    • /
    • pp.96-102
    • /
    • 2006
  • There are various factors affecting the fracture of NiTi rotary files. This study was performed to evaluate the effect of cross sectional area, pecking motion and pecking distance on the cyclic fatigue fracture of different NiTi files. Five different NiTi $files-Profile^{(R)}$ (Maillefer, Ballaigue, Switzerland), $ProTaper^{TM}$(Maillefer, Ballaigue, Switzerland), $K3^{(R)}$ (SybronEndo. Orange, CA) , Hero $642^{(R)}$ (Micro-mega, Besancon, France), Hero $Shaper^{(R)}$ (Micro-mega, Besancon, France)-were used. Each file was embedded in temporary resin, sectioned horizontally and observed with scanning electron microscope. The ratio of cross-sectional area to the circumscribed circle was calculated. Special device was fabricated to simulate the cyclic fatigue fracture of NiTi file in the curved canal,. On this device, NiTi files were rotated (300rpm) with different pecking distances (3 mm or 6 mm) and with different motions (static motion or dynamic pecking motion) . Time until fracture occurs was measured. The results demonstrated that cross-sectional area didn't have any effect on the time of file fracture. Among the files, $Profile^{(R)}$ took the longest time to be fractured. Between the pecking motions, dynamic motion took the longer time to be fractured than static motion. There was no significant difference between the pecking distances with dynamic motion, however with static motion, the longer time was taken at 3mm distance. In this study, we could suggest that dynamic pecking motion would lengthen the time for NiTi file to be fractured from cyclic fatigue.

Comparative Study of Texture of Al/Ti Thin Films Deposited on Low Dielectric Polymer and SiO$_2$Substrates (저 유전상수 폴리머와 SiO$_2$기판위에 형성된 Al/Ti박막의 우선방위 비교)

  • 유세훈;김영호
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.7 no.2
    • /
    • pp.37-42
    • /
    • 2000
  • The comparative study of texture of Al/Ti thin films deposited on low-dielectric polymer and $SiO_2$substrates has been investigated. Fifty-nm-thick Ti films and 500-nm-thick Al-1%Si-0.5%Cu (wt%) films were deposited sequentially onto low-k polymers and $SiO_2$by using a DC magnetron sputtering system. The texture of Al thin film was determined using X-ray diffraction (XRD) theta-2theta ($\theta$-2$\theta$) and rocking curve and the microstructure of Al/Ti films on low-k polymer and $SiO_2$substrates was characterized by cross-sectional transmission electron microscopy (TEM). Both the $\theta$-2$\theta$ method and rocking curve measurement suggest that Al/Ti thin films deposited on $SiO_2$have stronger texture than those deposited on low-k polymer. The texture of Al thin films strongly depended on that of Ti films. Cross-sectional TEM revealed that grains of Ti films on $SiO_2$substrates had grown perpendicular to the substrate, while the grains of Ti alms on SiLK substrates were formed randomly. The lower degree of (111) texture of Al thin films on low-k polymer was due to Ti underlayer.

  • PDF

Comparative Analysis of Body Measurement and Fit Evaluation between 2D Direct Body Measuring and 3D Body Scan Measuring (직접측정과 3차원 측정에 따른 인체치수 및 의복 착장 비교분석)

  • Istook, Cynthia L.;Lim, Ho-Sun;Chun, Jong-Suk
    • The Research Journal of the Costume Culture
    • /
    • v.19 no.6
    • /
    • pp.1347-1358
    • /
    • 2011
  • This study purposed to analyze differences in body measurement between the 2D direct body measuring method and the 3D body scan measuring method and to perform the appearance evaluation and cross-sectional evaluation of the fit of pants to which body measurements obtained by each measuring method were applied. Body measuring was conducted in 10 women in their 20s-30s using 2D direct body measuring and 3D automatic measuring with Hamamatsu body scanner. Among the 10 women, 3 participated in experimental garment wearing. Experimental pants were made using their 2D direct body measurements and 3D automatic measurements, and wearing tests were performed through expert evaluation and cross-sectional evaluation. The results of the experiment were as follows. According to the results of comparative analysis on differences between 2D direct body measurements and 3D scan measurements, 3D automatic measurements were significantly larger in bust circumference, ankle circumference, armscye circumference, shoulder length, scye depth, and arm length. As circumferences measured with the 3D body scanner were somewhat larger than directly measured ones, it is suggested to adjust ease when using existing pattern making methods. We prepared experimental garments by the same pattern making method through applying body measurements obtained with the two measuring methods, and assessed the fit of the garment comparatively through expert evaluation and 3D scan cross-sectional evaluation. According to the results, 2D-pants using 2D direct body measurements was slightly tighter than 3D-pants using 3D measurements in waist circumference, hip circumference, and abdominal circumference. In the results of comparing appearance in terms of the fit of the experimental garment in each subject, significant difference was observed in most of the compared items. This result suggests that 3D automatic body measuring data may show different accuracy according to body shape and therefore it is necessary to examine difference between 2D direct body measurements and 3D automatic measurements according to body shape.

A Study on the Factors Affecting Visitor's Attitude and Behavioral Intention to Visit Educational Farms (농촌교육농장 방문자의 행동의도 및 방문태도에 미치는 영향요인 연구)

  • Kwak, Byung-Jin;Noh, Gyoung-Soo;Shin, Ho-Kyun
    • Journal of Korean Society of Rural Planning
    • /
    • v.22 no.1
    • /
    • pp.37-48
    • /
    • 2016
  • The purpose of this study is to provide an objective insight for factors that affect people's visiting behavior to educational farms. Second, this study aims to identify the underlying dimensions representing motivations and constraints for visiting educational farms. Third, this study explores differences among the classified groups with respect to structural relationships of each construct. Finally, identifying strategies of educational farm-related organizations could develop to reinforce visit motivations, offset visit constraints and ultimately increase behavioral intention for potential possible visitors to revisit and recommend educational farms. Empirical results of the study suggest implications for promoting the current farm villages and markets with many stakeholders in agricultural industries. Nevertheless, there are some limitations as followed: first, despite the possibility of their effects, the study did not consider other factors, which could affect revisiting behavior such as destination image, experiencing attributes etc. Second, the study needs improvements through longitudinal research because the cross-sectional research could not rule out the alternative explanations. The directions for the future study are as follows: first, future study requires time series approach instead of cross sectional approach. Secondly, future study might utilize comparative study regarding regional characteristics of educational farms or a nation-wide approach. Thirdly, future study can suggest a combined educational farms considering practical educational farm cases. Lastly, it is considered that developing evaluation measures such as quality authentication system will contribute to educational farms' stabilization.

A Comparative Study on Structural Performance of Wind Turbine Composite Blades with Room-Temperature and Radiation Curing (상온 및 방사선 경화 복합재 풍력 블레이드의 구조성능 비교)

  • Jeon, Jae Heung;Kim, Sung Jun;Shin, Eui Sup
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.3
    • /
    • pp.203-209
    • /
    • 2012
  • In this paper, cross-sectional stiffnesses, static stresses, and dynamic natural frequencies are analyzed to examine the structural performance of wind turbine composite blades. The material properties of composite materials are based on room-temperature and radiation curing processes. The cross-sectional stiffnesses of composite blades are calculated by applying a beam theory with solid-profile cross sections. The wind turbine blades are modeled with a finite element program, and static analyses are carried out to check the maximum displacement and stress of the blades. In addition, dynamic analyses are performed to predict the rotating natural frequencies of the composite blades including the effects of centrifugal force. By comparing these analysis results, mainly owing to the material properties of composite materials, an improvement in the structural performance of the blades according to the curing process is investigated.