• Title/Summary/Keyword: Critical electric field

Search Result 174, Processing Time 0.026 seconds

DC and AC current transport characteristics of HTS tapes with external magnetic field (외부자계 영향에 따른 HTS 선재의 직$\cdot$교류 통전 특성)

  • 임성우;최용선;최효상;황시돌;정영호
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.15-18
    • /
    • 2003
  • HTS(High Temperature Superconductor) tapes have dependence on critical characteristics such as electric, magnetic field and temperature. In order to confirm these effects, we examined the current transport characteristics of HTS tapes. First, after being fed DC and AC, the dependence of HTS tapes of 10cm on external magnetic field was investigated. On centeral region of HTS tape, about 1cm, external magnetic field was applied. Second, after applying DC of 50A to HTS tapes, we applied time variable magnetic field about 100mT and investigated the quench characteristics. Finally, AC, which is about 10 times of I$_{c}$, was applied to HTS tapes and over current characteristics were investigated. The data acquired in this study will be used as a source for the study of HTS cable conductor which is supposed to carry on.n.

  • PDF

Electrorheology of conducting polyaniline-$BaTiO_3$ composite

  • Kim Ji-Hye;Fang Fei Fei;Lee Ki-Bo;Choi Hyoung-Jin
    • Korea-Australia Rheology Journal
    • /
    • v.18 no.2
    • /
    • pp.103-107
    • /
    • 2006
  • Organic-inorganic composite of polyaniline and barium titanate (PANI-$BaTiO_3$) was synthesized via an in-situ oxidation polymerization of aniline in the presence of barium titanate ($BaTiO_3$) nanoparticles dispersed in an acidic medium. Barium titanate has large electric resistance and relatively high dielectric constant which is one of the essential properties for its electrorheological (ER) applications. The microstructure and composition of the obtained PANI/$BaTiO_3$ composite were characterized by SEM, FT-IR and XRD. In addition, we also employed a rotational rheometer to investigate the rheological performance of the ER fluids based on both pure PANI particle and PANI/$BaTiO_3$ composite. It was found that the composite materials possess much higher yield stresses than the pristine PANI due to unique dielectric properties of the inorganic $BaTiO_3$ particles. Finally, we also examined dynamic yield stress by analyzing its extrapolated yield stress data as a function of electric field strengths. Using the critical electric field strengths deduced, we further found that the universal yield stress equation collapses their data onto a single curve.

Evaluation of Ageing Characteristics of Polymeric Insulators for Distribution Lines by Tracking Wheel Test (Tracking wheel 시험을 통한 배전용 폴리머애자 열화특성 평가)

  • Lee, Byung-Sung;Han, Jae-Hong;Han, Yong-Heui;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2314-2316
    • /
    • 1999
  • This study describes the results of aging characteristics of polymer insulators through the tracking wheel test. In order to evaluate the reliability of polymer insulators, 4 polymer insulators which used in the field were selected. Electrical tests such as power frequency voltage test, steep-front impulse voltage test were performed after tracking wheel test. Chemical structure and contact angle were measured for investigating an aging characteristics. Although some changes have occurred on the surface of insulator, there are no critical changes between new and tracking wheel tested insulator.

  • PDF

Sterilization of Yakju(Rice Wine) Using a Batch-type High Voltage Pulsed Electric Field System (고전장펄스를 이용한 약주의 회분식 살균)

  • Kim, Su-Yeon;Park, Young-Seo;Mok, Chul-Kyoon
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.5
    • /
    • pp.1247-1253
    • /
    • 1999
  • Yakju(rice wine) was sterilized with high-voltage pulses of short time on a batch pulsed electric field(PEF) system. The initial microbial counts of Yakju were 7.52 X $10^4\;CFU/mL$ for total aerobes, 2.20 X $10^4\;CFU/mL$ for lactic acid bacteria and 7.08 X $10^4\;CFU/mL$ for yeasts. The pH, acidity and electric conductivity of Yakju were 3.36, 0.462% and 1.24 mS/cm, respectively. Yakju was treated with 2-250 of pulses exponential-wave formed electric pulses under the field strength of 12.5-25 kV/cm. The critical strengths of the electrical field for the sterilization of Yakju were 7.5 kV/cm for total aerobes, 8.5 kV/cm for lactic acid bacteria and 6.5 kV/cm for yeasts. Logarithmic survival rates decreased linearly at low pulse number, but curvilinearly at high pulse number. The PEF sterilization kinetics of Yakju could be analysed by In s = In A-k In (n) and the sterilization rate constant increased with electric field strength and the size of target microorganisms. No changed in pH, acidity, and the growth of microorganisms were found in the PEF treated Yakju during the storage for 6 weeks at both $4^{\circ}C$ And $30^{\circ}C$.

  • PDF

Neutron Irradiation Effect of YBa2Cu3O7-y Superconductor (YBa2Cu3O7-y 초전도 벌크의 중성자 조사 효과)

  • Lee, Sang Heon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.6
    • /
    • pp.438-441
    • /
    • 2021
  • The electrical characteristics of single-crystal composite superconductors produced by a melting process were studied by neutron irradiation. In order to improve the current characteristics of the YBa2Cu3O7-y superconductor, it is necessary to form an effective flux pinning center inside the superconductor. In this study, an increase in flux pinning was attempted through neutron irradiation onto YBa2Cu3O7-y superconductors. The neutron irradiation was performed at 30 MeV for 500 sec, The electrical properties of the superconductors were measured in a magnetic field of 5 Tesla at 50 K using a magnetic properties measurement system (MPMS). After neutron irradiation, the critical current density of the YBa2Cu3O7-y superconductor in a 1 Tesla magnetic field was 1×105 A/cm2. Once neutrons were irradiated at 30 MeV and 10 μA for 500 sec, the critical current density was observed to increase significantly. When neutrons are irradiated to a superconductor, micro-defects are created in the superconductor, and they act as flux pinning centers that hold the magnetic field generated when an electric current flows.

Superconducting film fabrication using field Assisted Electrophoresis (보조전계를 이용한 전기영동 초전도 막의 제작)

  • 소대화;전용우
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.2
    • /
    • pp.157-162
    • /
    • 2003
  • For fabricating high T$\sub$c/ superconducting deposition film, novel electrophoretic deposition (EPD) technique applied to deposit surface charged particles on metal substrate with only d.c field has been studied. However, the electric properties of superconducting film could not be improved easily by this way, because the particles of EPD film were usually deposited randomly on metal substrate without any directional orientation affected to its critical current density. For the purpose of obtaining partcle orientation on the EPD films, the new method modified by a.c. assisted field to the conventional electrophoresis system was investigated to improve the particle deposition density and to increase the contacting area among the particles with highly oriented particle deposition of BSCCO superconducting film.

Transient loss analysis of non-insulation high temperature superconducting coil using the field-based data profiling method

  • Hoon Jung;Yoon Seok Chae;June Hee Han;Ji Hyung Kim;Seung Hoon Lee;Ho Chan Kim;Young Soo Yoon;Ho Min Kim
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.3
    • /
    • pp.38-42
    • /
    • 2023
  • The evaluation of no-insulation (NI) high-temperature superconducting (HTS) typically uses the lumped equivalent circuit (LEC) model. Constant parameters in the NI HTS LEC model accurately predict voltage and central magnetic field at currents below the critical current. However, it is difficult to find constant circuit parameters that simultaneously satisfy the measured voltage and magnetic field under overcurrent conditions. Recent research highlights changes in contact resistance during transient conditions, which may impact power loss estimation in NI HTS coils. Therefore, we confirm the influence of contact resistance changes on loss calculation in the transient state for NI HTS coil. To achieve this, we introduce a measurement data analysis method based on the LEC model and compare it with the LEC model using constant circuit parameters.

Development of Large-sized YBCO High Temperature Superconductor Bulk Magnets and Actuator (대면적 YBCO 고온 초전도 벌크 자석 및 조작기 개발)

  • Han, Sang-Chul;Park, Byung-Jun;Jung, Se-Yong;Han, Young-Hee;Lee, Jong-Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.7
    • /
    • pp.450-455
    • /
    • 2015
  • For the practical application of a YBCO superconductor bulk, the superconductor bulk magnet with high magnetic field on a large area surface should be fabricated. To make this, YBCO single crystal bulks with fine $Y_2BaCuO_5$(Y211) particles have been prepared by the top-seed melt growth(TSMG) method with $YBa_2Cu_3O_x$, $Y_2O_3$, and $CeO_2$ mixing precursor. By using $Y_2O_3$ instead of $Y_2BaCuO_5$ as precursor, the manufacturing process became simpler and more economical. The microstructures, trapped field and critical current density of the various conditioned YBCO bulks have been observed, analyzed and measured. The different characteristic values of the several samples have been analyzed from the viewpoint of their microstructures. We have developed a $8{\times}12cm$ size superconductor bulk magnet, up to 3 T class, by using the 4 T class-high field superconducting magnetizer and confirmed the applicability of the transmission level circuit breakers by measuring the strength and speed of the superconductor bulk magnet actuator.

Magnetic field dependence of critical current and index n in a Bi-2223/Ag superconductor tape (Bi-2223/Ag 초전도 선재에서 임계전류와 인덱스의 자계의존성)

  • Kim Jung Ho;Kim Kyu Tae;Lim Jun Hyung;Jang Seok Hern;Rho Yun Bong;Joo Jinho;Choi Seyong;Nah Wansoo;Hong Gye-Won
    • Progress in Superconductivity
    • /
    • v.6 no.1
    • /
    • pp.79-83
    • /
    • 2004
  • We fabricated Bi-2223/Ag superconductor tape with 55 filaments and estimated the magnetic field dependence of critical current (I$_{c}$) and index n (n) up to 30 T at 4.2 K. The I$_{c}$ and n were characterized as a function of external magnetic field parallel to the tape surface on increasing and decreasing field, using a 35 T hybrid magnet. The $I_{c}$ was estimated to be 325 A, and n was 32, 22, and 26 in the electric field range of $0.1 ∼1\mu$V/cm, 1∼10 $\mu$V/cm, and 0.1∼10 $\mu$V/cm, respectively, under self-field at 4.2 K. It was observed that $I_{c}$ was dependent on magnitude of magnetic field and it decreased exponentially as the field increased; in a parallel and increasing field, It was 128 A at 30 T which is approximately 40% of critical current in self-field. In addition, the $I_{c}$ was higher on decreasing field than that on increasing one. On the other hand, n did not significantly depend on field strength up to 30 T, nor varied on whether increasing or decreasing field; n value in 0.1∼1 $\mu$V/cm was 23.0$\pm$5.2 and 27.8$\pm$8.0 on increasing and decreasing field, respectively. The n value on decreasing magnetic field was slightly higher than that on increasing field. This hysteretic behavior of n was similar to that of$ I_{c}$, which is related to the trapped flux at the grain boundary.ary.

  • PDF

A Study on the Generation of the Earth Potential and Communication Line Noise. (대지전위와 통신회선 잡음 발생에 대한 고찰)

  • Yeo, Sang-Kun;Park, Chan-Won
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.33-38
    • /
    • 2007
  • This paper presents a experimental evidence of the generation of the earth potential and communication line noise from the electric railway. There is a critical measurement err in case of measuring the electrical power induced noise voltage and degree of cable balance in the field of earth potential generated. As a results, it has been found that the conventional cable has more noise immunity than shielded cable near the railway where the earth current flows through the sheath layer.

  • PDF