• Title/Summary/Keyword: Criteria of Quality Management

Search Result 867, Processing Time 0.036 seconds

Quality Control of Radiation Dosimetry Service (개인피폭선량 측정기관의 품질관리기준 개발)

  • Lee, Jun-Haeng;Lee, Sang-Bock;Chang, Kun-Jo;Lee, Kwang-Yong;Lee, Hyun-Koo;Kim, Hyeog-Ju;Jin, Gye-Hwan
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.253-259
    • /
    • 2009
  • We have developed standards based on international criterions for the quality control of dose tested by the measurement institutions of individual exposure doses through improving the reliability of data on the exposure dose of individuals working in radioactive environment and securing the accuracy and reliability of individual dose measurements. Laws related to radiation dose applied to domestic institutions refer to ANSI N13.11.1993, but currently, in U.S. and some other countries the measurement of radiation doses is based on ANSI N13.11.2001 that reduced test categories and tightened the standards. We made efforts to simplify the standards and to reduce the number of dosimeters required in experiment, and avoided preventing or hindering the use of future technologies not approved under the current law such as glass dosimeter and optical stimulation dosimeter. The Quality Management Manual of Radiation Dosimetry Service, Assessment Manual of Radiation Dosimetry Service Accreditation Program, and the Personnel Dosimetry Performance. Criteria for Testing are documents applicable in supervising laboratories.

  • PDF

Study of Sources Affecting Customer Satisfaction in Healthcare Service Business: with Focus on Comparison of Wellbeing Care, Yoga, and Fitness Businesses (건강관리 서비스 산업에서 고객만족에 영향을 미치는 요인에 관한 연구 - 산림 건강치유, 요가, 휘트니스 산업비교를 중심으로 -)

  • Kim, Joon-Ho;Choi, Ji-Eun
    • Management & Information Systems Review
    • /
    • v.29 no.4
    • /
    • pp.305-332
    • /
    • 2010
  • This study was searching for elements affecting satisfaction of customers by comparing health management service businesses such as wellbeing care, yoga, and fitness. The discovered elements were analyzed and verified to find which elements are affecting what businesses through case studies. Multidirectional analysis was implemented for each service type using program, physical environment, and provided service drawn from the previous researches with SERVQUAL criteria and measured values on customer satisfactions. According to the analysis, physical environment in forest wellbeing care, program in yoga, and provided service in fitness were the most affecting elements. Thus, each health management service business must consider the lifestyle and trend of customers, and the specialized service corresponding to its uniqueness must be provided to customers. Surely, modernized exercise equipment, personalized program, and comfortable-luxurious settings are must have in order to be competitive. In addition, the business owners have to realize that customers are moving to quality from quantity. This means exercise must be brought up to the level of social value for relationship and links rather than left at the level of simple physical and mental trainings. To achieve these, other programs to support relationship among customers and circulating system with friendly environment must be considered at the same time.

  • PDF

Developments of Evaluation System of Mission Oriented Government-Supported Research Institute by Article Citation Method (피인용 특성 분석을 통한 출연(연) 임무중심형 기관평가 개선 방향)

  • Lee, Moon Young;Yi, Chan Goo
    • Proceedings of the Korea Technology Innovation Society Conference
    • /
    • 2016.05a
    • /
    • pp.404-430
    • /
    • 2016
  • This study started from the awareness of the issue if the citation index newly introduced to evaluate the quality of papers satisfies the proper timing matter, which is a component of performance indicators for the evaluation of government-funded R&D institutes. Accordingly, the study will propose improvement ways to shift the previous evaluation system to quality evaluation for mission-oriented R&D institutes by analysing and using the periodical characteristics such as citation half-life and immediacy index of papers. As a result, it turned out that the speed of academic change is getting faster in proportion to the dependency on the technological development but that the citation speed in the field of public technology is relatively slower and the speed of knowledge transfer in the fields related to industry is faster. In addition, the citation index among the R&D fields showed no differences, and the minimum period for citation index measurement with validity should be over 6 years. The problems of evaluation for mission-oriented R&D institutes were deducted based on the technical and statistical analysis results of the temporal characteristic of citation necessary for quality evaluation of performance among R&D fields. To solve the problems, policy alternatives for object and valid quality evaluation were proposed from the points of evaluation period, evaluation criteria, and evaluation management.

  • PDF

Analysis of Effectiveness of Spectrum of Energy and Image Quality Evaluation by Aluminium Filter in the added Compound Filtration (에너지 스펙트럼과 화질평가를 통한 복합부가여과에서 알루미늄 여과판의 효율성 분석)

  • Kim, Sang-Hyun;Choi, Jae-Ho
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.187-197
    • /
    • 2015
  • This study analysed the effectiveness of aluminium(Al) filter in the added compound filtration for the removal of characteristic radiation by energy spectrum and image evaluation. 0.1, 0.2, 0.3 mm copper with and without 1 mm Al were evaluated. The energy spectrum was measured using the GATE and evaluated separately by each energy. Image quality was evaluated by PSNR, MAE, MSE, CNR, SNR and qualitative analysis was performed by seven items for resolution and contrast from chest x-ray criteria of National Cancer Screening and Cardiovascular evaluation table. In the analysis of the quality of the energy per photon spectrum with the exception of a low energy region, without Al were superior in all area. PSNR MAE, MSE, CNR, SNR and qualitative analysis were the same or slightly better. PSNR was over 30 dB and all significant and the p>0.05 in the T-test of qualitative analysis. The energy spectrum and image quality have little difference between before and after use of Al filter. Therefore, it is effective to use the Al filter for the radiation dose management with the compensation capability of DR system.

Conditions and Performance of Quality Improvement Activity in Korean Dental Hospitals (치과의료 질 향상활동 현황과 개선활동 만족도)

  • Kim, Han-Na;Kim, Ho;Kim, Hae-Young
    • Journal of dental hygiene science
    • /
    • v.13 no.4
    • /
    • pp.359-368
    • /
    • 2013
  • This study aimed to evaluate conditions and performance of quality improvement (QI) activity in Korean dental hospitals. Twenty one representative dental hospitals in Korea were selected by the selection criteria. A questionnaire was implemented to measure awareness, perceived needs, educations, conferences, works, activating/obstructive factors and satisfaction related to QI activities. Satisfaction score range from 0 (lowest) to 5 (highest) among 329 dental hygienists who worked in the selected 21 dental hospitals. Implementation rate of programs on external customer satisfaction was the highest 59.9% in QI activities, and reduction of expenses (59.4%), Improvement in health care quality (58.7), risk management (52.8) were followed, while improvement in work efficiency (46.5) showed the lowest implementation rate. The most influencing factor accelerating QI activities was 'active participation of hospital workers' (54.7%), and 'effort to improve customer satisfaction' (44.7%) followed. The most influencing QI related obstructive factor was 'lack of QI-related manpower and support' (47.1%). A balanced development including QI programs with lower implementation rates is necessary. Encouraging participation of workers may be the most important in developing dental QI activities further.

A Convergence Study on Evaluation of Usefulness of Copper Additional Filter in the Digital Radiography System (디지털 방사선장치에서 구리 부가필터의 유용성 평가에 관한 융복합 연구)

  • Kim, Sang-Hyun
    • Journal of Digital Convergence
    • /
    • v.13 no.9
    • /
    • pp.351-359
    • /
    • 2015
  • This convergence study analyzed the effectiveness of digital radiography system of copper(Cu) filter in the added filtration for the removal of lower energy radiation through dose and image evaluation. We were analyzed from April to June 2015 result of the examination. Cu filter was applied to each non, 0.1, 0.2, 0.3 mm according to change of kV and mAs and doses were evaluated. Image quality was evaluated by PSNR, MAE, MSE, CNR, SNR and qualitative analysis was performed by seven items for resolution and contrast from chest x-ray criteria of national cancer checkup. The absorbed doses with Cu were lowered by 16-88 % than non-filter but the gaps decreased as kV increased. PSNR were over 30 dB and all significant and CNR and SNR were superior with non-filter but in the qualitative analysis, there were different statistical significant according to each item. The score of 0.1 mm filter was high at pulmonary blood vessel observation and in the 0.3 mm Cu, there were no statistical signigicant except high density and full of air portion. Cu filter can improve image quality with lower radiation dose using better radiation quality and correction power at digital radiography system.

A Program of Water Quality Management for Agricultural Reservoirs by Trophic State (농업용 저수지의 부영양화와 수질관리방안)

  • Lee, Kwang-Sik;Yoon, Kyung-Sup;Kim, Ho-Il;Kim, Hyung-Joong
    • Korean Journal of Environmental Agriculture
    • /
    • v.22 no.2
    • /
    • pp.166-171
    • /
    • 2003
  • A total of 498 agricultural reservoirs ranging from $164{\times}10^3\;m^3$ to $253{\times}10^6\;m^3$ in storage volume were investigated from 1990 to 2001 with respect to Chl-${\alpha}$, COD concentration and pollutant loading of BOD, TN, and TP. The lakes and reservoirs could be classified to 4 types using the relationships between the ratio of storage volume per water surface area(ST/WS) and Chl-${\alpha}$ concentration. It is recommended that the improvement of polluted lakes should be performed in the order of integrated consolidation type ${\rightarrow}$ watershed consolidation type ${\rightarrow}$ in-lake consolidation type ${\rightarrow}$ Management type and reservoir should be constructed to be over $5{\sim}6\;m$ in depth(ST/WS ratio) for preventing the eutrophication of agricultural reservoirs. We propose that water quality criteria for agricultural water is changed from less than 8 mg/L to less than 6 mg/L for safety value, $6{\sim}10\;mg/L$ for concern value, and more than 10 mg/L for countermeasure value in COD concentration, respectively.

Characteristics of stormwater runoff from urbanized areas (도시화된 토지이용에서 유출되는 강우유출수의 유출특성분석)

  • Mercado, Jean Margaret R.;Geronimo, Franz Kevin F.;Choi, Jiyeon;Song, Young-Sun;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.14 no.2
    • /
    • pp.159-168
    • /
    • 2012
  • Stormwater runoff affects the quality of surface water and groundwater due to the nonpoint sources (NPSs) of pollutants that it carries during storm events. Typically, urbanized areas experience high pollutant mass emission because of paved roads and other areas which are all highly impervious. For this reason, proper identification of the levels of pollutants from the watershed area is important to pass the Ministry of Environment of the Republic of Korea's water quality standards in rivers and streams. This research was conducted in order to determine and quantify the different constituents present in stormwater runoff generated from highly impervious areas in Cheonan City, Korea. Also, the average event mean concentration (EMC) of stormwater runoff from paved areas was compared with EMCs of other countries to determine the possible causes of its occurrence. In addition, the occurrence of first flush phenomenon was studied in order to find the first flush criteria to be used on the design of best management practices. The results show the pollutant concentration of stormwater runoff was higher than other countries due its landuse and relatively small size of catchment area. During the first 30 minutes of the rainfall events, occurrence of first flush phenomenon was highly evident. Several factors affected the pollutant concentrations in the stormwater such as landuse type, geographic and topographic characteristics,catchment area and amount of rainfall. This research can provide guidance in achieving an effective NPS pollution management applicable to highly urbanized areas in the future.

Evaluation of TVOC regulation level of sealant products in accordance with simultaneous revision of testing method and regulation value in the law of indoor air quality management (실내 공기질 공정시험방법과 기준의 동시 개정에 따른 실란트 제품의 TVOC 관리수준 평가)

  • Yoo, Ji-Ho;Park, Joon-Man;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.138-146
    • /
    • 2010
  • The Korean Ministry of the Environment revised a few sections of the regulations in the Law of indoor air quality management for the reinforcement or adjustment of the regulation criteria standard for releasing pollutants from building materials. Especially, in case of sealant, the contents covering liquid building materials, excess standards and testing methods have been added simultaneously in this revision, As a result it is impossible to compare original standards with revised standards directly. For this reason, this study reviewed revised test method of sealant pollutant emission rates in terms of impact and validity in comparison with the original test method. Through this study, the basic properties of revised pollutant emission control standards was assessed. Especially in sealant, since each product has a wide deviation of time required for complete drying, it is proved that there are a large number of products that are not hardened completely in test time. The result of our experiments on the revised test methods showed that this revised test methods yield emission rates that are two and half times less than those of the original testing method. To apply the revised test method of sealant to all the sealant products, It is necessary to extend the test period or improve specimen to fit the test method for quickly drying sealant products.

An Empirical Study of the Clinically Reportable Range in Clinical Chemistry (임상보고 가능범위의 실증적 연구)

  • Chang, Sang-Wu;Lee, Sang-Gon;Choi, Ho-Seong;Song, Eun-Young;Park, Yong-Won;Lee, In-Ae
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.39 no.1
    • /
    • pp.31-36
    • /
    • 2007
  • The purpose of the clinically reportable range (CRR) in clinical chemistry is to estimate linearity in working range. The reportable range includes all results that may be reliably reported, and embraces two types of ranges: the analytical measurement range (AMR) is the range of analyte values that a method can directly measure on the specimen without any dilution, concentration, or other pretreatment not part of the usual assay process. CAP and JCAHO require linearity on analyzers every six months. The clinically reportable range is the range of analyte values that a method can measure, allowing for specimen dilution, concentration, or other pretreatment used to extend the direct analytical measurement range. The AMR cannot exceed the manufacturer's limits. Establishing AMR is easily accomplished with Calibration Verification Assessment and experimental Linearity. For example: The manufacturer states that the limits of the AST on their instrument are 0-1100. The lowest level that could be verified is 2. The upper level is 1241. The verified AMR of the instrument is 2-1241. The lower limit of the range is 2, because that is the lowest level that could be verified by the laboratory. The laboratory could not use the manufacturer's lower limit of 2 because they have not proven that the instrument values below 2 are valid. The upper limit of the range is 1241, because although the lab has shown that the instrument is linear to 1241, the manufacturer does not make that claim. The laboratory needs to demonstrate the accuracy and precision of the analyzer, as well the validation of the patient AMR. Linearity requirements have been eliminated from the CLIA regulations and from the CAP inspection criteria, however, many inspectors continue to feel that linearity studies are a part of good lab practice and should be encouraged. If a lab chooses to continue linearity studies, these studies must fully comply with the calibration/calibration verification requirements of CLIA and/or CAP. The results of lower limit and upper limit of clinically reportable range were total protein (2.1 - 79.9), albumin (1.3 - 39), total bilirubin (0.2 - 106.2), alkaline phosphatase (13 - 6928.2), aspartate aminotransferase (24 - 7446), alanine aminotransferase (13 - 6724.2), gamma glutamyl transpeptidase (16.64 - 9904.2), creatine kinase (15.26 - 4723.8), lactate dehydrogenase (127.66 - 13231.8), creatinine (0.4 - 129.6), blood urea nitrogen (8.67 - 925.8), uric acid (1.6 - 151.2), total cholesterol (48.52 - 3162), triglycerides (36.91 - 3367.8), glucose (31 - 4218), amylase (21 - 6694.2), calcium (3.1 - 118.2), inorganic phosphorus (1.11 - 108), HDL (11.74 - 666), NA (58.3 - 1800), K (1.0 - 69.6), CL (38 - 1230).

  • PDF