• Title/Summary/Keyword: CrS

Search Result 2,261, Processing Time 0.034 seconds

Diffusion of Cr(VI) in Porous Media (심층 지하에서의 육가 크롬 확산)

  • 현재혁
    • The Journal of Engineering Geology
    • /
    • v.3 no.2
    • /
    • pp.203-214
    • /
    • 1993
  • Underground Injection Control regulations for Class I injection wells require that the vertical dufusion be considered as a mechanism for transport of contaninants in evaluating containment Due to the low permeability in the confining aquitard, the movement of contaminants over the long term is controlled by the molecular diffusion. The movement can be predicted, using the Fick' S second law of diffusion. The diffusion coefficient in Fick' s law has been determined experimentally in this study. Instantaneous injection of $^{51}Cr$ was used to trace the distribution of Cr(VI) in soil plugs and an analytical solution was applied to calculate the diffusion coefficients. This study shows the effect of environmental factors, such as temperature, chloride concentration, applied amount of $^{51}Cr$, and bulk density of injection formations on diffusion of Cr(VI)

  • PDF

Sargassum confusum for Biosorption of Pb and Cr (알송이 모자반, Sargassum confusum을 이용한 Pb 및 Cr의 생물학적 흡착 및 탈착)

  • SUH Kuen-Hack;ANN Kab-Hwan;CHO Moon-Chul;CHO Jin-Koo;JIN Hyung-Joo;HONG Yong-Ki
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.34 no.1
    • /
    • pp.1-6
    • /
    • 2001
  • Biosorption of Pb and Cr by Sargassum confusum was evaluatet at in the various conditions. The uptake capacities for Pb and Cr were 197.5 mg Pb/g biomass and 133.1 mg Cr/g biomass, respectively. The adsorption parameters for Pb and Cr were determined according to the Langmuir and Freundlich model. Biosorption of Pb and Cr was increased with the increase of pH value. Pb and Cr adsorbed by S. confusum could be recovered by desorption process with 0.1 M HCl, 0.1 M $HNO_3$ and 0.1 M EDTA. The ratio of Pb desorption was above $93\%$, whereas the ratio of Cr desorption was below $30\%$.

  • PDF

A Comparative Study on Image Quality of Breast Image Tests using ACR Phantom (ACR 팬텀을 이용한 시스템별 유방검사 영상의 비교 연구)

  • Hong, Dong-Hee;Jung, Hong-Ryang;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.241-247
    • /
    • 2006
  • Recently, interests and utilization on Computed Radiography(CR) and Digital Radiography(DR) tends to increase owing to an introduction of Picture Archiving and Communication System(PACS) and an accuracy control of special medical equipment for a breast imaging examination. This study was intended to compare and analyze a detector's imaging quality by each system to be used for the breast imaging examination by using ACR Phantom used at the accuracy control. As an evaluation method, a significance and reliability of image's value using the ACR Phantom was analyzed by using SPSS program. The results are followed. 1. For the fiber, there was 3.9 score in Screen-Film, 4.2 score in CR($50{\mu}m$), 3.2 score in CR($100{\mu}m$), and 4.2 score in DR. There was the high score in the order of CR($50{\mu}m$), DR, Screen-Film, and CR($100{\mu}m$)(P<0.05). 2. For the calcification, there was 2.7 score in Screen-Film, 2.5 score in CR($50{\mu}m$), 2.0 score in CR($100{\mu}m$), and 2.9 score in DR. There was the high score in the order of DR, Screen-Film, CR($50{\mu}m$), and CR($100{\mu}m$).(0.025(P<0.05). 3. For Mass, there was 3.8 score in Screen-Film, 3.8 score in CR($50{\mu}m$), 3.6 score in CR($100{\mu}m$), and 4.5 score in DR. There was the high score in the order of DR, CR($50{\mu}m$), Screen-Film, and CR($100{\mu}m$) (P<0.1). 4. As the total score, there was 10.4 score in Screen-Film, 10.6 score in CR($50{\mu}m$), 8.7 score in CR($100{\mu}m$), and 11.3 score in DR. There was the high score in the order of DR, $CR(50{\mu}m$), Screen-Film, and $CR(100{\mu}m$). As shown in the above results, it can be known that DR and Screen-Film System has higher image quality than CR. But, DR has unstability caused by element, and Screen-Film has the low image quality caused by artifact as disadvantages. When Dual-Side CR($50{\mu}m$) was used among CR systems which had the problem of low image quality, it was indicated that there was no difference with Screen-Film System. Because the radiation imaging examination tends to become digitalized, each system for the breast imaging examination will need to be developed and supplemented.

  • PDF

Effect of Sulfur on the High-temperature Oxidation of Fe-34.4Cr-14.5Ni-2.5Mo-0.4W-0.4Mn-0.5Si Alloys (Fe-34.4Cr-14.5Ni-2.5Mo-0.4W-0.4Mn-0.5Si 합금의 고온 산화에 미치는 S의 영향)

  • Lee, Dong Bok;Lee, Kyong-Hwan;Bae, Geun Soo;Cho, Gyu Chul;Jung, Jae Ok;Kim, Min Jung
    • Journal of the Korean institute of surface engineering
    • /
    • v.50 no.5
    • /
    • pp.386-391
    • /
    • 2017
  • Two kinds of steels whose compositions were Fe-34.4Cr-14.5Ni-2.5Mo-0.4W-0.4Mn-0.5Si-(0.009 or 0.35)S (wt.%) were centrifugally cast, and oxidized at $900^{\circ}C$ for 50-350 h in order to find the effect of sulfur on the high-temperature oxidation of Fe-34.4Cr-14.5Ni-2.5Mo-0.4W-0.4Mn-0.5Si-(0.009 or 0.35)S (wt.%) alloys. These alloys formed oxide scales that consisted primarily of $Cr_2O_3$ as the major oxide and $Cr_2MnO_4$ as the minor one through preferential oxidation of Cr and Mn. They additionally formed $SiO_2$ particles around the scale/alloy interface as well as inside the matrices. The high affinity of Mn with S led to the formation of scattered MnS inclusions particularly in the 0.35S-containing cast alloy. Sulfur was harmful to the oxidation resistance, because it deteriorated the scale/alloy adherence so as to accerelate the adherence and compactness of the formed scales.

Influence of Ozone Treatment on Cr(VI) Adsorption of Activated Carbon (오존처리가 활성탄소의 Cr(VI) 흡착특성에 미치는 영향)

  • Park, Soo-Jin;Kim, Byeong-Joo
    • Korean Chemical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.644-649
    • /
    • 2006
  • In this paper, the Cr(VI) adsorption behaviors of activated carbons (ACs) treated by various ozone treatment conditions were studied. The surface properties of the ACs studied were determined by pH, acid-base, and FT-IR measurements. $N_2$ adsorption isotherm characteristics at 77K were confirmed by BET equation, Boer's t-plot method, and Horvath-Kawazoe's slit pore model. Also, the total Cr adsorption amount onto the ACs was measured by ICP-AES. As a result, the ozone treatment led to an increase of oxygen-containing polar functional groups and total acidity as well. Meanwhile, the specific surface areas or micropore volumes were slightly decreased after the ozone treatment due to the micropore filling or blocking. Nevertheless, the total Cr adsorption of ACs was increased with increasing of the ozone treatment time, attributed to the good interaction between Cr ions and polar functional groups on the ACs.

Magnetoresistance Effects in Cr5S6 Single Crystal (Cr5S6 단결정의 자기저항 효과)

  • Lee, Kyung-Dong;Song, Ki-Myung;Hur, Nam-Jung
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.6
    • /
    • pp.207-211
    • /
    • 2010
  • We have investigated the magnetoresistance effect in $Cr_5S_6$ single crystals prepared by vapor transport method. Room temperature X-ray diffraction (XRD) study reveals the phase formation of the single crystals with trigonal crystal structure. The magnetization was measured as a function of temperature (5 K~400 K) and applied magnetic field (0.1 T and 5 T). The magnetization curve as a function of temperature reveals the two transition states of $Cr_5S_6$: one from antiferromagnetic to ferrimagnetic state at ~150 K and the other from ferrimagnetic to paramagnetic state at ~300 K. Temperature dependent resistivity at 0 T and 5 T magnetic field shows the metallic behavior, showing the transition from antiferromagnetic to ferrimagnetic state at ~150 K. Magnetic field dependence of magnetization was measured at four fixed temperatures viz. 100 K, 150 K, 200 K, and 300 K. It is observed that at 200 K and 300 K it shows well M-H hysteresis behavior, whereas at 100 K and 150 K it shows non-hysteretic nature. A negative magnetoresistance (MR) of -2% is observed at 5 T for $Cr_5S_6$ single crystal at 150 K, near the antiferromagnetic transition temperature.

Corrosion of Fe-2.25%Cr-1.6%W Steel at 600 and 700℃ in N2/(0.5, 2.5)%H2S-mixed Gas

  • Lee, Dong Bok;Bak, Sang Hwan
    • Journal of the Korean institute of surface engineering
    • /
    • v.49 no.4
    • /
    • pp.339-343
    • /
    • 2016
  • ASTM T23 steel with a composition of Fe-2.25%Cr-1.6%W corroded at 600 and $700^{\circ}C$ for 5-70 h in $N_2$/(0.5, 2.5)%$H_2S$-mixed gas at 1 atm. It corroded rapidly, forming the outer FeS scale and the inner (FeS, $FeCr_2O_4$)-mixed scale. The ensuing outward diffusion of $Fe^{2+}$ ions during corrosion led to the protrusion of FeS platelets over the outer FeS scale. The formation of FeS at the surface facilitated the oxidation of Cr to $FeCr_2O_4$ in the inner scale. Since the nonprotective FeS scale existed over the whole scale, T23 steel displayed poor corrosion resistance in the $H_2S$-containing atmosphere.

The Electromagnetic Properties in Uncoupled funnel-junction with Various Cr Seed Layer (비결합형 터널접합구조에서 Cr 하지층에 따른 전자기적 특성변화)

  • Park, J.W.;Jeon, D.M.;Yoon, S.Y.;Lee, J.Y.;Suh, S.J.
    • Journal of the Korean Magnetics Society
    • /
    • v.13 no.3
    • /
    • pp.91-96
    • /
    • 2003
  • Cross-geometrical Cr/Co/Al-Ox/Co/Ni-Fe tunnel junctions were fabricated by magnetron sputtering. To form an insulating layer, The Al layer was oxidized in an atmosphere of oxygen-argon mixture at low power after deposition. To enhance the coercivity of the bottom Co layer, The Cr seed layer was deposited on the glass and it led to increase in coercivity. The coercivity increase is due to the increase of roughness through the Cr thickness. In over oxidation time, the oxidation of Co bottom layer and flat interface of insulator can increase the bottom Co coercivity. But TMR ratio gradually decrease. TMR ratio is relevant with Cr thickness, insulator thickness, and oxidation time. The maximum TMR ratio was 14% at room temperature and the TMR ratio was decreased to half at 0.51 V.

Removal of hexavalent chromium using modified pistachio shell

  • Parlayici-Karatas, S.;Pehlivan, E.
    • Advances in environmental research
    • /
    • v.1 no.2
    • /
    • pp.167-179
    • /
    • 2012
  • Pistachio shell (Pistacia vera) (PS), a low-cost material, has been utilized for the removal of the Cr(VI) ions after treatment with citric acid. Batch experimental steps were applied to obtain Cr(VI) ion adsorption details for the equilibrium between Cr(VI) and modified pistachio shell (MPS). The influences of contact time, pH, adsorbent dose and initial chromium concentration on the adsorption performance of MPS was investigated in detail. The results displayed that adsorption of Cr(VI) by MPS reached to equilibrium after 2 h and after that a little change of Cr(VI) removal efficiency was observed. The sorption percent is higher at lower pH and lower chromium concentration. Two possible mechanisms for reduction of Cr(VI) to Cr(III) can be suggested in Cr(VI) removal. In the first mechanism, Cr(VI) is reduced to Cr(III) by surface electron-donor groups of the adsorbent and the reduced Cr(III) forms complexes with adsorbent or remains in the solution. This Cr(III) is not adsorbed by adsorbent at pH 1.8. But in second mechanism, the adsorption-coupled reduction of Cr(VI) to Cr(III) occurred on the adsorbent sites. The equilibrium sorption capacity of Cr(VI) ion after 2 h was 64.35 mg/g for MPS.

A STUDY ON THE TRIBOLOGICAL CHARACTERISTICS OF FeCrSi/A366.0 ALLOY COMPOSITES

  • Song, Tae-Hoon;Choi, Yong-Bum;Park, Sung-Ho;Huh, Sun-Chul;Park, Won-Jo
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.262-267
    • /
    • 2007
  • In this paper, we study about wear properties for the metal matrix composites fabricated by low pressure infiltration process. Metal fiber preform reinforced aluminum alloy composite were fabricated by low pressure casting process under 0.4MPa. Infiltration condition was changed the pressure infiltration time of 1 s, 2 s and 5 s under a constant pressure of 0.4MPa. The molten alloy completely infiltrated the FeCrSi metal perform regardless of the increase in the pressure acceleration time. However, the infiltration time at the pressure acceleration time of 1s was shorter than at the pressure acceleration time of 2s or 5s. The FeCrSi/A366.0 composite was investigated the porosity. The porosity is reducing as the pressure acceleration time compared with the pressure acceleration time of 2s and 5s. The FeCrSi/A366.0 composites were investigated the wear resistance. FeCrSi/A366.0 composite at pressure acceleration time of 1s has excellent wear resistance.

  • PDF