• Title/Summary/Keyword: Cr equivalent

Search Result 97, Processing Time 0.022 seconds

Influence of Annealing Temperature on Microstructure and Pitting Corrosion Behavior of the 27Cr-7Ni Hyper Duplex Stainless Steel

  • Jeon, Soon-Hyeok;Kim, Hye-Jin;Kong, Kyeong-Ho;Park, Yong-Soo
    • Corrosion Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.48-55
    • /
    • 2014
  • Influence of annealing temperature on the microstructure and resistance to pitting corrosion of the hyper duplex stainless steel was investigated in acid and neutral chloride environments. The pitting corrosion resistance is strongly dependent on the microstructure, especially the presence of chromium nitrides ($Cr_2N$), elemental partitioning behavior and volume fraction of ferrite phase and austenite phase. Precipitation of deleterious chromium nitrides reduces the resistance to pitting corrosion due to the formation of Cr-depleted zone. The difference of PREN (Pitting Resistance Equivalent Number) values between the ferrite and austenite phases was the smallest when solution heat-treated at $1060^{\circ}C$. Based on the results of electrochemical tests and critical crevice temperature tests, the optimal annealing temperature is determined as $1060^{\circ}C$.

Modal rigidity center: it's use for assessing elastic torsion in asymmetric buildings

  • Georgoussis, George K.
    • Earthquakes and Structures
    • /
    • v.1 no.2
    • /
    • pp.163-175
    • /
    • 2010
  • The vertical axis through the modal center of rigidity (m-CR) is used for interpreting the code torsional provisions in the design of eccentric multi-story building structures. The concept of m-CR has been demonstrated by the author in an earlier paper and the particular feature of this point is that when the vertical line of the centers of mass at the floor levels is passing through m-CR, minimum base torsion is developed. For this reason the aforesaid axis is used as reference axis for implementing the code provisions required by the equivalent static analysis. The study examines uniform mixed-bent-type multistory buildings with simple eccentricity, ranging from torsionally stiff to torsionally flexible systems. Using the results of a dynamic response spectrum analysis as a basis for comparisons, it is shown that the results of the code static design are on the safe side in torsionally stiff buildings, but unable to predict the required strength of bents on the stiff side of systems with a predominantly torsional response. Suggestions are made for improving the code provisions in such cases.

CYCLIC SUBMODULES AND MODULES ASSOCIATED WITH THEM

  • Park, Chin-Hong
    • Journal of applied mathematics & informatics
    • /
    • v.4 no.2
    • /
    • pp.563-571
    • /
    • 1997
  • In this paper we define CR(completely reachable), MICR(minimal cyclic refinement)and MACR(maximal cyclic refinement)-Modules. We have obtained equivalent statements for minimal cyclic submodule and maximal cyclic submodule. Also we have obtained necessary and sufficient conditions for a module M with MICR to be cyclic or strongly cyclic.

Strong-max cyclic submodules

  • Chin-Hong Park
    • Journal of the Korean Mathematical Society
    • /
    • v.35 no.1
    • /
    • pp.1-9
    • /
    • 1998
  • In this paper we define CR(completely reachable), MICR(minimal cyclic refinement) and MACR(maximal cyclic refinement)-Modules. We have obtained equivalent statements for minimal cyclic submodule and maximal cyclic submodule. Also, we have obtained necessary and sufficient conditions for a module M with MICR to be cyclic or strongly cyclic.

  • PDF

Study of Image Properties for Computed Radiography (Computed Radiography의 영상특성에 관한 연구)

  • Ryu, Ki-Hyun;Jung, Jae-Eun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.2
    • /
    • pp.23-31
    • /
    • 2008
  • Computed radiography(CR) has been widely used in the field of diagnostic radiography since digital X-ray image was introduced. The imaging performance of CR system was studied by analyzing the digital image data of the CR images which are the outcomes of the whole imaging system composed of image plate(IP), laser digitizer, analoge-digital convertor, and a given image processing unit. In this study, we used a conventional CR system made by Agfa. From the flat field image of 150$\times$150 image pixels, signal-to-noise ratio(SNR) was calculated. SNR of the CR image increases in proportion to logarithm value of the X-ray exposure irradiated on the IP. SNR is less than about 6 at the exposure below 0.2mR and is more than 10 at the exposure above 0.54mR. In our study, most of images obtained by the smaller exposures less than 2.0mR can not be readable. In general, the minimum value of the SNR ranges from 3 to 5. We obtained modulation transfer function(MTF) by analyzing the bar pattern image which was made under conditions as follows: X-ray tube potential was 55kVp, the IP exposure was 0.54 mR, and the distance between X-ray source to IP was 2m, where bar pattern was located on the IP. MTF is 23% at 2.5lp/mm spatial frequency. Provided that the MTF of noise equivalent modulation is 10%, the CR system has the limiting spatial resolution of 3.2lp/mm. If the image sharpness is evaluated by the spatial frequency where MTF is 50%. the corresponding spatial frequency is 0.5$\sim$0.75lp/mm. MTFA(Modulation Transfer Function Area) is 1.0lp/mm. Compared with the Fuji CR whose MTFA is 1.1lp/mm, Agfa CR in this study shows almost same MTFA performance.

  • PDF

The Correlation of Refractive Error and Ocular Dimensions in Older Age (고령의 연령에서 굴절이상과 안광학 성분들의 연관성 분석)

  • Lim, Byung Kwan;Jeon, Soon-Woo;Jeong, Youn Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.293-297
    • /
    • 2011
  • Purpose: This study was to know the correlation among refractive error and the dimensions of ocular components on older adults. Methods: The subjects were 95 older age who had no eye diseases. The refractive error, corneal radius, corneal diopter, axial length, anterior chamber depth and lens thickness were measured and analysed. Results: The axial length(AL)/corneal radius(CR) ratio was positively correlated with the corneal diopter, axial length, the anterior chamber depth. Then it was negatively correlated with corneal radius. It was shown that the highest correlation was between the corneal diopter and axial length (r = -0.545, p = 0.000). The spherical equivalent of the refractive error was negatively correlated with the AL/CR ratio. Conclusions: It was shown that the AL/CR ratio was a very important indicator for diagnosing the refractive error of the old age.

Bioaccumulation of Chromium Ions by Immobilized Cells of a Filamentous Cyanobacterium, Anabaena variabilis

  • Khattar, Jasvir I.S.;Sarma, Tangirala-A.;Singh, Davinder-P.;Sharma, Anuradha
    • Journal of Microbiology and Biotechnology
    • /
    • v.12 no.1
    • /
    • pp.137-141
    • /
    • 2002
  • Anabaena variabilis ATCC 29413 grew in chromium (Cr) containing Chu-10 (basal) and nitrate-supplemented media, and the growth of the organism in $100{\mu}M$ chromium was found to be 50% of that in control medium. The growth in nitrate $({NO_3}^-)$ supplemented cultures was better as compared to cultures grown in basal medium. Free cells from basal and nitrate-supplemented media removed 5.2 and 7.4 nmol of chromium $mg^{-1}$protein in 8 h, respectively, from the medium containing $30{\mu}M$ chromium. The efficiency of chromium removal increased 7-fold in imidazole buffer (0.2 M, pH 7.0). A cell density equivalent to $100{\mu}g$ protein $ml^{-1}$ was found to be optimum for maximum Cr removal. Entrapment of cells in calcium-alginate beads did not affect the rate of Cr uptake by the cells. The efficiency of the laboratory-scale continuous flow bioreactor $(12.5{\times}2cm)$ loaded with alginate-immobilized cells (10 mg protein) and fed with $30{\mu}M$ chromium solution was compared at different flow rates. The efficiency of the bioreactor varied with flow rates. In terms of percent removal of Cr from influent, a flow rate of 0.1 ml $min^{-1}$ was found to be optimum for 6 h (54% Cr removal efficiency). Maximum amount of Cr (883 nmol) was removed by the cells in 3 h at a flow rate of 0.5 ml $min^{-1}$. The potential use of A. variabilis in removing Cr from industrial effluents is discussed.

A study on the thermal-mechanical fatigue life prediction of 12 Cr steel (12 Cr 강의 열피로 수명단축에 관한 연구)

  • Ha, Jeong-Soo;Kim, Kun-Young;Ahn, Hye-Thon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.4
    • /
    • pp.114-125
    • /
    • 1994
  • Fatigue behavior and life prediction method were presented for themal-mechanical and isothermal low cycle fatigue of 12 Cr forged steel used for high temperature applications. In-phase and out-of-phase thermal-mechanical fatigue test from 350 .deg. C to 600 .deg. C and isothermal low cycle fatigue test at 600 .deg. C, 475 .deg. C, 350 .deg. C were conducted using smooth cylindrical hollow specimen under strain-control with total strain ranges from 0.006 to 0.015. The phase difference between temperature and strain in thermal-mechanical fatigue resulted in significantly shorter fatigue life for out-of-phase than for in-phase. Thermal-mechanical fatigue life predication was made by partitioning the strain ranges of the hysteresis loops and the results of isothermal low cycle fatigue tests which were performed under the combination of slow and fast strain rates. Predicted fatigue lives for out-of-phase using the strain range partitioning method showed an excellent agreement with the actual out-of-phase thermal-mechanical fatigue lives within a factor of 1.5. Conventional strain range partitioning method exhibited a poor accuracy in the prediction of in-phase range partitioning method in a conservative way. By the way life prediction of thermal-mechanical fatigue by Taira's equivalent temperature method and spanning fartor method showed good agreement within out-of-phase thermal-mechanical fatigue.

  • PDF

Synthesis of Alkylidyne Complexes of Br$(CO)_2(tmeda)M{\equiv}CC_{6}H_{4}Me$ (M = Cr, Mo, W). Crystal Structure of Br$(CO)_2(tmeda)M{\equiv}CC_{6}H_{4}Me$

  • Park, Joon T.;Cho, Jeong-Ju;Suh, Il-Hwan;Lee, Jin-Ho;Lim, Sung-Su;Ryu, Bo-Young
    • Bulletin of the Korean Chemical Society
    • /
    • v.14 no.2
    • /
    • pp.266-271
    • /
    • 1993
  • The reaction of $(CO_5$)M=C(OMe)Tol (M=Cr, Mo, W and $Tol=p-C_6H_4Me)$ and $BBr_3$ followed by treatment with tetramethylethylenediamine (TMEDA) yields a mixture of two diastereomers, trans, $cis-Br(CO)_2(tmeda)M{\equiv}$CTol [M=Cr(1a), Mo(2a), W(3a)] and cis, $trans-Br(CO)_2(tmeda)M{\equiv}$CTol [M=Cr(1b), Mo(2b), W(3b)], respectively. These compounds have been isolated as crystalline solids and characterized by spectroscopic (infrared, mass, $^1H$ and $^{13}C-NMR)$ data. The trans, cis-Br(CO)2(tmeda)Cr${\equiv}$CTol (1a), has been examine via a single crystal X-ray diffraction study : $BrCrO_2N_2C_{16}H_{23}$, Mr=407.27, triclinic, $P{\bar{1}},\;a=12.792(2),\;b=13.400(5),\;c= 11.645(4)\;{\AA},\;{\alpha}=101.26(2)^{\circ},\;{\beta}=103.04(2)^{\circ},\;{\gamma}=91.88(2)^{\circ},\;{\nu}=1907(1){\AA}^3,\;Z=2,\;{\rho}(calcd)=1.418\;gcm^{-3},\;{\lambda}(MoK{\alpha})=0.71069\;{\AA},\;{\mu}=26.25 cm^{-1},\;F(000)=831.97,\;T=295K,\;R=0.0977$ for 1332 significant reflections $[F_0>5{\sigma}(F_0)]$. There are two essentially equivalent molecules in the crystallographic asymmetric unit. Each molecule is octahedral with the bromide ligand trans to the alkylidyne carbon, the two cis-carbonyl ligands, and the bidentate TMEDA ligand.