• Title/Summary/Keyword: Counting efficiency

Search Result 149, Processing Time 0.024 seconds

Novel Architecture for Efficient Implementation of Dimmable VPPM in VLC Lightings

  • Jeong, Jin-Doo;Lim, Sang-Kyu;Jang, Il-Soon;Kim, Myung-Soon;Kang, Tae-Gyu;Chong, Jong-Wha
    • ETRI Journal
    • /
    • v.36 no.6
    • /
    • pp.905-912
    • /
    • 2014
  • In this paper, a new architecture is proposed to achieve complexity efficiency in implementing variable pulse position modulation (VPPM). VPPM, specified in IEEE 802.15.7, can support wireless communication and dimming control simultaneously using visible light. The proposed architecture is based on the VPPM signal property in which the transition point of the modulated output is obtained by counting the sample index and comparing it to both the assigned dimming factor and the transmitting data. Therefore, the proposed architecture can be composed of simple logics, including a counter, a comparator, and an inverter, all of which are insensitive to the dimming resolution in contrast to a conventional codeword-table method. This paper describes the verification of the proposed algorithm through a register-transfer level implementation of the codeword and proposed architectures. In comparison with the codeword-table method, the proposed method gains a nine-fold complexity reduction at a 1% dimming-step resolution.

International Comparison of Absolute Activity Measurement of $^{133}Ba$ Solution ($^{133}Ba$ 용액의 방사능 절대측정의 국제비교)

  • Park, Tae-Soon;Oh, Pil-Jae;Hwang, Sun-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.10 no.2
    • /
    • pp.130-136
    • /
    • 1985
  • The activity measurement of a solution of $^{133}Ba$ which is an electron capture nuclide was carried out by the ${\beta}-{\gamma}$ coincidence method. The counting rates at the ${\beta}-,\;{\gamma}-$, and coincidence-channels were measured using a $4{\pi}$ proportional counter and two NaI(Tl) scintillation detectors. The specific activity of the solution calculated by the efficiency extrapolation was $(1151.01{\pm}2.99)kBqg^{-1}$ at the reference time(00h UT, 03-15-84). According to an international comparison of activity measurements organized by the Bureau International des Poids et Mesures, this result showed the difference of 0.94% to the mean value derived from the comparison.

  • PDF

Feasibility study of SiPM based scintillation detector for dual-energy X-ray absorptiometry

  • Park, Chanwoo;Song, Hankyeol;Joung, Jinhun;Kim, Yongkwon;Kim, Kyu Bom;Chung, Yong Hyun
    • Nuclear Engineering and Technology
    • /
    • v.52 no.10
    • /
    • pp.2346-2352
    • /
    • 2020
  • Dual-energy x-ray absorptiometry (DXA) is the noninvasive method to diagnose osteoporosis disease characterized by low bone mass and deterioration of bone tissue. Many global companies and research groups have developed the various DXA detectors using a direct photon-counting detector such as a cadmium zinc telluride (CZT) sensor. However, this approach using CZT sensor has some drawback such as the limitation of scalability by high cost and the loss of efficiency due to the requirement of a thin detector. In this study, a SiPM based DXA system was developed and its performance evaluated experimentally. The DXA detector was composed of a SiPM sensor coupled with a single LYSO scintillation crystal (3 × 3 × 2 ㎣). The prototype DXA detector was mounted on the dedicated front-end circuit consisting of a voltage-sensitive preamplifier, pulse shaping amplifier and constant fraction discriminator (CFD) circuit. The SiPM based DXA detector showed the 34% (at 59 keV) energy resolution with good BMD accuracy. The proposed SiPM based DXA detector showed the performance comparable to the conventional DXA detector based on CZT.

Dimmable Spatial Intensity Modulation for Visible-light Communication: Capacity Analysis and Practical Design

  • Kim, Byung Wook;Jung, Sung-Yoon
    • Current Optics and Photonics
    • /
    • v.2 no.6
    • /
    • pp.532-539
    • /
    • 2018
  • Multiple LED arrays can be utilized in visible-light communication (VLC) to improve communication efficiency, while maintaining smart illumination functionality through dimming control. This paper proposes a modulation scheme called "Spatial Intensity Modulation" (SIM), where the effective number of turned-on LEDs is employed for data modulation and dimming control in VLC systems. Unlike the conventional pulse-amplitude modulation (PAM), symbol intensity levels are not determined by the amplitude levels of a VLC signal from each LED, but by counting the number of turned-on LEDs, illuminating with a single amplitude level. Because the intensity of a SIM symbol and the target dimming level are determined solely in the spatial domain, the problems of conventional PAM-based VLC and related MIMO VLC schemes, such as unstable dimming control, non uniform illumination functionality, and burdens of channel prediction, can be solved. By varying the number and formation of turned-on LEDs around the target dimming level in time, the proposed SIM scheme guarantees homogeneous illumination over a target area. An analysis of the dimming capacity, which is the achievable communication rate under the target dimming level in VLC, is provided by deriving the turn-on probability to maximize the entropy of the SIM-based VLC system. In addition, a practical design of dimmable SIM scheme applying the multilevel inverse source coding (MISC) method is proposed. The simulation results under a range of parameters provide baseline data to verify the performance of the proposed dimmable SIM scheme and applications in real systems.

Quantification of the ichthyotoxic raphidophyte Chattonella marina complex by applying a droplet digital PCR

  • Juhee, Min;Kwang Young, Kim
    • ALGAE
    • /
    • v.37 no.4
    • /
    • pp.281-291
    • /
    • 2022
  • Quantifying the abundance of Chattonella species is necessary to effectively manage the threats from ichthyotoxic raphidophytes, which can cause large-scale mortality of aquacultured fish in temperate waters. The identification and cell counting of Chattonella species have been conducted primarily on living cells without fixation by light microscopy because routine fixatives do not retain their morphological features. Species belonging to the Chattonella marina complex, including C. marina and C. marina var. ovata, had high genetic similarities and the lack of clear morphological delimitations between the species. To estimate the abundance of C. marina complex in marine plankton samples, we developed a protocol based on the droplet digital polymerase chain reaction (ddPCR) assay, with C. marina complex-specific primers targeting the internal transcribed spacer (ITS) region of the rDNA. Cell abundance of the C. marina complex can be determined using the ITS copy number per cell, ranging from 25 ± 1 for C. marina to 112 ± 7 for C. marina var. ovata. There were no significant differences in ITS copies estimated by the ddPCR assay between environmental DNA samples from various localities spiked with the same number of cells of culture strains. This approach can be employed to improve the monitoring efficiency of various marine protists and to support the implementation of management for harmful algal blooms, which are difficult to analyze using microscopy alone.

A Preliminary Study for the Analytical Method and Environmental Characteristics of Radium-226 in Groundwater (지하수 중 라듐-226의 분석방법 및 환경 특성에 관한 예비 연구)

  • Jeong, Do-Hwan;Kim, Moon--Su;Noh, Hoe-Jung;Yoon, Yoon-Yeol;Kim, Dong-Soo;Lee, Young-Joon;Ju, Byoung-Kyu;Hong, Jung-Ki;Kim, Tae-Seung
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.2
    • /
    • pp.22-27
    • /
    • 2012
  • $^{226}Ra$ in groundwater could be analyzed by various methods. LSC (liquid scintillation counter) is used to measure its activity of Ba co-precipitates with Hisafe III scintillation cocktail solution. Counting efficiency was obtained using NIST $^{226}Ra$ standard solution in triplicate and calculated $^{226}Ra$ concentration using the efficiency values. $^{226}Ra$ values of 19 groundwaters having Gross-${\alpha}$ concentrations of more than 5 pCi/L ranged from ND (${\leq}$ 0.1 pCi/L) to 1.18 pCi/L. Geologic settings of the 19 areas are composed of granitic rocks of Pre-Cambrian and Jurassic and Cretaceous, gneiss (schist) of Pre-Cambrian, and volcanic rocks of Cretaceous. No relationship was shown among $^{226}Ra$ a concentrations and in-situ water quality data, and Gross-${\alpha}$, uranium, radon concentrations.

Fused Polypeptide with DEF Induces Apoptosis of Lung Adenocarcinoma Cells

  • Liang, Ai-Ling;Zhang, Ting-Ting;Zhou, Ning;Huang, Di-Nan;Liu, Xin-Guang;Liu, Yong-Jun;Tu, Zhi-Guang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.12
    • /
    • pp.7339-7344
    • /
    • 2013
  • To analyze the effects of a new unknown peptide DEF on the growth of tumor cells, a fused polypeptide TAT-DV1-DEF was designed and synthesized. The lung adenocarcinoma cell line GLC-82 treated with TAT-DV1-DEF was analyzed with a cell counting kit 8, and the location of polypeptides in cells was observed under laser confocal microscopy. The efficiency of polypeptide transfection and changes in nuclear morphology were analyzed by flow cytometry and fluorescence microscopy, respectively. Finally, the mechanism of tumor cell growth inhibition was evaluated by Western blotting. We found that TAT-DV1-DEF could significantly inhibit the growth of the lung adenocarcinoma cell line GLC-82, but not the normal human embryonic kidney cell line HEK-293. Polypeptides were found to be mostly localized in the cytoplasm and some mitochondria. The efficiency of polypeptide transfection in the two cell types was approximately 99%. Apoptotic nuclei were observed under fluorescence microscopy upon treatment with polypeptides and DAPI staining. Western blot analyses indicated that the polypeptide inhibition of tumor cell growth was apoptosis dependent. In the present study, we demonstrated that fused polypeptides could induce apoptosis of the lung adenocarcinoma cell line GLC-82, indicating that the new unknown peptide DEF has antitumor effects.

Combined X-ray CT/SPECT System with a Common CZT Detector (CZT검출기를 이용한 CT/SPECT 조합영상시스템)

  • 권수일
    • Progress in Medical Physics
    • /
    • v.13 no.4
    • /
    • pp.229-233
    • /
    • 2002
  • We have tested a combined CT/SPECT system with a single CZT detector for x-ray and gamma-ray medical imaging. The size of detector is 10$\times$10$\times$5 ㎣, and the anodes are pixellated as a 4$\times$4 array with a pixel dimension of $1.5\times$1.5 $\textrm{mm}^2$. The cathode was coated with a continuous Au-plated. We have characterized the system performance by scanning a radiographic resolution phantom and the Hoffman Brain phantom. Pulse counting electronics with very short shaping time (50 ㎱) are used to satisfy high photon rates in x-ray imaging, and response linearity up to 3$\times$10$^{5}$ counts per second per detector element is achieved. Energy resolution of 10.4% and 5.3% FWHM at Tc-99m 140 keV peak are obtained for the 50 ㎱ and 2 $mutextrm{s}$ shaping times, respectively. The spatial resolutions of CT and SPECT are about 1mm and 9mm, respectively. Photopeak efficiency of detector systems are 41.0% for 50㎱ and 72.5% for 2 $mutextrm{s}$ shaping time.

  • PDF

Design of Variable Average Operation without the Divider for Various Image Sizes (다양한 영상크기에 적합한 나눗셈기를 사용하지 않은 가변적 평균기의 설계)

  • Yang, Jeong-Ju;Jeong, Hyo-Won;Lee, Sung-Mok;Choi, Won-Tae;Kang, Bong-Soon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.10 no.4
    • /
    • pp.267-273
    • /
    • 2009
  • In this paper, we proposed a variable average operation for a WDR(Wide Dynamic Range). The previously proposed average operation [5] improves hardware efficiency and complexity by replacing divider with multiplier. However, the previously proposed method has some weak-points. For example, there are counting horizontal and vertical length, and then the multiplier selects a Mode set by the user when the lengths exactly correspond with the image's size in the Mode. To compensate some weak-points, we change a Mode selection methods as a using the image's total size. Also, we propose another feature that it can be applied to various image sizes. To get a more accurate average, we add an external compensation value. We design the variable average operation using a Verilog-HDL and confirm that the Serial Multiplier's structure is better efficiency than Split Multiplier's structure.

  • PDF

Study of the determination of 226Ra in soil using liquid scintillation counter (액체섬광계수기를 이용한 토양 중 226Ra 분석 방법 연구)

  • Jung, Yoonhee;Kim, Hyuncheol;Chung, Kun Ho;Kang, Mun Ja
    • Analytical Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.65-72
    • /
    • 2016
  • This study presented an analytical method for detecting radium in soils using a liquid scintillation counter (LSC). The isotope 226Ra was extracted from soil using the fusion method and then separated from interfering radionuclides using the precipitation method. Radium was coprecipitated as sulfate salts with barium (Ba) and then converted into Ba(Ra)CO3, which is soluble in an acidic solution. The isotope 222Rn, the decay progeny of 226Ra, was trapped in a water immiscible cocktail and analyzed by LSC. The pulse shape analysis (PSA) level was estimated using 90Sr and 226Ra standard solutions. The figure of merit was the highest at PSA 80, while the alpha spillover was the lowest at PSA 80. The counting efficiency was 243 ± 2% in a glass vial. This analytical method was verified with International Atomic Energy Agency (IAEA) reference materials, including IAEA-312, IAEA-314, and IAEA-315. The recovery ranged from 60–82%, while the relative bias between the measured value and the recommended value was less than 10%. The minimum detectable activity was 2.1 Bq kg−1 with dry mass 1 g, the background count rate of 0.02 cpm, the recovery rate of 70% and counting time of 30 min.