• Title/Summary/Keyword: Counter-type

Search Result 440, Processing Time 0.023 seconds

Analysis of Performance Characteristics in the Counter and Parallel Type Plate Evaporator with Operating Methods (대향류와 평행류형 판형 증발기에서 운전방식에 따른 성능특성 분석)

  • Bae, Kyung-Jin;Cha, Dong-An;Kwon, Oh-Kyung
    • Journal of Power System Engineering
    • /
    • v.17 no.3
    • /
    • pp.50-56
    • /
    • 2013
  • The analysis of performance characteristics was carried out in the plate type evaporator with counter and parallel flow. To investigate performance of evaporator with water inlet temperature and refrigerant mass flow rate were changed. As a result, when the inlet temperature of water is $8^{\circ}C$, capacity of parallel flow evaporator higher than counter flow is 0.35%. But as the inlet temperature of water rises from $8^{\circ}C$ to $16^{\circ}C$, capacity of counter flow type evaporator higher than parallel flow type is 0.12%, 0.27%, 1.1%, 1.6%, respectively. The findings showed that counter flow type evaporator has a larger capacity than those that were parallel flow type evaporator. As the refrigerant mass flow rate rises, capacity and pressure drop increases in the counter and parallel flow type evaporator.

Counter weight design for a W/V type reciprocating air compressor (W형 및 V형 왕복동 공기압축기의 평형추 설계)

  • 김영철;성세제;김영주;최상규
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.227-233
    • /
    • 2002
  • For the purpose of high outlet pressure, compactness and low vibration and noise, modem reciprocating air compressors are tend to have a multi-stage W-type or V-type cylinder arrangement. An effective counter weight calculation method is presented for reducing the inertia forces of the compressor. This calculation method is using the complex representation and verified its validity. A design program for the counter weight of W-type or V-type air compressor was presented to the manufacturer, A designed counter weight was attached to the W-type or V-type air compressor. Vibration test results gave us improved performance.

  • PDF

Current Driving Type Surge Counter (전류구동형 서지카운터)

  • Lee, B.H.;Ahn, C.H.;Chang, S.H.;Jeong, K.M.;Jeon, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1712-1714
    • /
    • 1997
  • This paper deals with the surge counter drived by lightning and switching currents. In order to install the effective surge protective devices, it is important to find the parameters of incident surges. In this paper, for the purpose of protecting the electronic circuits and counting the occuring frequency, the current driving type surge counter is designed and fabricated. The surge counter consists of surge protective divices, current detector, metal oxide varistor(MOV), rectifier, capacitor, and electromagnetic counter. This surge counter is able to count the occuring frequency of surges and to clamp lightning surge current. To evaluate the performance of the surge counter, impulse voltage and current were applied at the surge counter by the surge generator. As a result, applied surges were exactly counted and clamped.

  • PDF

Counter Weight Design of Multi-stage Reciprocating Air Compressors (다단 왕복동 공기압축기의 평형추 설계)

  • Kim, Young-Cheol;Kim, Byung-Ok;Shin, Hyun-Ik
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.656-661
    • /
    • 2003
  • Modem reciprocating air compressors have tendency to a multi-stage W-type or V-type cylinder arrangement for the purpose of high outlet pressure, compactness and low vibration and noise. A valid counter weight calculation method using the complex expression is proposed for reducing the inertia forces of the compressor. Counter weight removes only 1st forward whirl component. Counter weight formulations are applied to the six various compressor structures which are (a) 1 cylinder single-throw crank shaft, (b) 2 cylinder single-throw crank shaft (c) 2 cylinder double-throw clank shaft, (d) 3 cylinder single-throw crank shaft, (e) 4 cylinder single-throw crank shaft and (f) 4 cylinder double-throw crank shaft. The improvement of performance is verified through available vibration test.

  • PDF

Priority Control Using Delay Counter for ATM Switch (ATM 스위치에서 지연카운터를 이용한 우선순위 제어 기법)

  • 김변곤
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06c
    • /
    • pp.339-342
    • /
    • 1998
  • The various services that a broadband integrated services digital network (B-ISDN) carries, have a wide range of delay, delay jitter and cell loss probability requirements. Design of appropriate control schemes for B-ISDN is an extremely important and challenging problem. In this paper, we proposes a priority control scheme with a delay counter and a cell counter per each class type. The priority control for required service quality is performed with delay/loss factor obstained by comparing window counter with cell counter. The performance of proposed control scheme is estimated by computer simulation.

  • PDF

Design of Synchronous Quaternary Counter using Quaternary Logic Gate Based on Neuron-MOS (뉴런 모스 기반의 4치 논리게이트를 이용한 동기식 4치 카운터 설계)

  • Choi Young-Hee;Yoon Byoung-Hee;Kim Heung-Soo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.3 s.333
    • /
    • pp.43-50
    • /
    • 2005
  • In this paper, quaternary logic gates using Down literal circuit(DLC) has been designed, and then synchronous Quaternary un/down counter using those gates has been proposed The proposed counter consists of T-type quaternary flip flop and 1-of-2 threshold-t MUX, and T-type quaternary flip flop consists of D-type quaternary flip flop and quaternary logic gates(modulo-4 addition gates, Quaternary inverter, identity cell, 1-of-4 MUX). The simulation result of this counter show delay time of 10[ns] and power consumption of 8.48[mW]. Also, assigning the designed counter to MVL(Multiple-valued Logic) circuit, it has advantages of the reduced interconnection and chip area as well as easy expansion of digit.

A Study on the Characteristic of Dye-sensitized Solar Cell by Controlling the Roughness Factor of Counter Electrode (염료감응형 태양전지의 상대전극 Roughness Factor 조절을 통한 셀 특성 연구)

  • Son, Min-Kyu;Seo, Hyun-Woong;Lee, Kyoung-Jun;Kim, Jeong-Hoon;Kim, Hee-Je
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.428-430
    • /
    • 2008
  • Dye-sensitized solar cell has many internal resistant components such as Pt counter electrode, $TiO_2$/dye/electrolyte, charge diffusion, sheet resistance of TCO. Among these, the resistance about the counter electrode can be reduced by increasing the roughness factor of Pt counter electrode. This causes the increase of fill factor and improvement of efficiency. And the amount of light reflection on the counter electrode also increases as the roughness factor goes up. In our experiment, we suggest a new deposition structure of Pt thin film that is a stepped-type structure. The more step lines are in the counter electrode, the more roughness factor is. As a result, we get the improvement of fill factor and efficiency by controlling the roughness factor of counter electrode.

  • PDF

The Experimental Study of the Hybrid Cooling Tower using Cross and Counter Type Fills (직교.대향류 충진재를 이용한 하이브리드 냉각탑에 대한 실험적 연구)

  • Jun, C.H.;Lee, H.S.;Lee, H.C.;Moon, C.G.;Kim, J.D.;Kim, Eun-Pil;Yoon, J.I.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.236-237
    • /
    • 2005
  • An experimental study on the Hybrid Cooling Tower has been done having a rated capacity of 3RT. Counter flow type fill, cross flow type fill and hybrid-type fill which is combined with two type fills as previously stated having a height of 0.3m have been used in the 0.8m${\times}$0.4m${\times}$1.9m dimensional tower respectively. The heat exchanger is consisting of 2 or 3 rows. The relevant temperatures and the velocities were selected based on the typical Korean weather for the year round operation of the tower. The cooling capacity of the tower is explained with respect to varying air inlet velocities, wet-bulb temperatures, and air to cooling water volume flow rate ratio (L/G ratio). The capacity of the hybrid-type fill was much superior to other fills, but hybrid-type fill shows higher pressure drop.

  • PDF

Analysis on the Discharge Characteristics of AC Plasma Display Panel with Counter Sustain Electrodes (교류형 플라즈마 표시기의 신 대향형 구조에 대한 방전 특성 분석)

  • Bae, Hyun-Sook;Whang, Ki-Woong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.9
    • /
    • pp.1579-1583
    • /
    • 2008
  • We proposed the new structure of ac plasma display panel(PDP) to improve the luminous efficacy and driving voltage characteristics. Through two-dimensional numerical simulations, we analyzed the effects of new counter discharge type, which consists of counter sustain electrodes and auxiliary electrodes. Generally, an advantage of AC PDP with the counter sustain electrodes has been known for the driving characteristics of the low voltage. In this work, the new counter structure using the ignition discharge by the auxiliary pulse applied to the address electrode showed the result of the increased luminous efficacy. The short gap discharge between two auxiliary electrodes on the front plate could intensity the long gap discharge between counter electrodes. The reliability of simulation result could be confirmed by the experimental result in the test panel.

A Study on the Counter Program of the Radiation Detector Using 8051 Micro-controller (8051 마이크로 콘트롤러를 이용한 휴대용 방사능 측정기의 카운터 프로그램 연구)

  • Kim, Yong-Duk;Park, Se-Kwang
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.228-236
    • /
    • 1997
  • Radioactive materials need to control, measure and protect precisely the overflow because they are dangerous. In this paper, GM-counter type radiation detector system, that can precisely measure the quantity of radioactivity using improved counting program is designed and program that can store and transfer the counted data is studied. The manufactured system, counting system of GM-counter type radiation detector, and counter program can be utilized to measure them at various methods in an atomic power plant and research centers.

  • PDF