• Title/Summary/Keyword: Counter-method

Search Result 852, Processing Time 0.023 seconds

A Study on Dynamic Characteristics of Hydraulic Motor Brake System with Counter Balance Valve (카운터 밸런스 밸브를 내장한 유압 모터 브레이크 시스템의 동특성)

  • Yun, So-Nam;Lee, Ill-Yeong
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.29 no.3
    • /
    • pp.214-219
    • /
    • 1993
  • Counter balance valve is used as one part of hydraulic motor brake system. The function of this valve is to protect over-run or free falling of inertia load. But occasionally the brake system with counter balance valve makes some undesirable problems such as pressure surges or vibrations. These problems may hurt system safety and driver's conformability. Nevertheless, studies on dynamic characteristics of hydraulic system including counter balance valve are very rare, so further accumulation of research results are required. In this study, for the purpose of easy estimation about dynamic characteristics of hydraulic system including counter balance valve, precise formulation describing fluid dynamics and valve dynamics under various boundary conditions were made. The equations obtained in the preceding process include some parameters that must be got experimentally. Flow coefficients of valve and choke are the most significant ones among the parameters. So these parameters are obtained experimentally in this study, and experimental equations obtained from the experimental data were used for numerical calculation. The equations were analysed by numerical integration using Runge-Kutta method, because the equations contain various nonlinear terms. From the numerical analysis, it was verified that the dynamic response of counter balance valve and pressure variation at each elements can be estimated very easily. So the analysing method developed in this study enabled very easy estimating the relation between the performances of counter balance valve and various physical parameters related to the valve. Conclusively, it is said that the results obtained in this study can be used very usefully to develop a new type counter balance valve or to apply the valve to actual hydraulic system for various industrial equipments.

  • PDF

Counter weight design for a W/V type reciprocating air compressor (W형 및 V형 왕복동 공기압축기의 평형추 설계)

  • 김영철;성세제;김영주;최상규
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.227-233
    • /
    • 2002
  • For the purpose of high outlet pressure, compactness and low vibration and noise, modem reciprocating air compressors are tend to have a multi-stage W-type or V-type cylinder arrangement. An effective counter weight calculation method is presented for reducing the inertia forces of the compressor. This calculation method is using the complex representation and verified its validity. A design program for the counter weight of W-type or V-type air compressor was presented to the manufacturer, A designed counter weight was attached to the W-type or V-type air compressor. Vibration test results gave us improved performance.

  • PDF

An Analytical Study for Determining Optimum Section and Trench Range on Soft Counter Weight Fill (연약지반상 압성토의 최적단면 및 측구위치 결정을 위한 해석적 연구)

  • Park, Jongcheol;Chang, Yongchai;Baek, Incheol;Jung, Donghwan
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.1
    • /
    • pp.51-58
    • /
    • 2015
  • The counter weight filling is a technology to accumulate soils on the side of berm with a proper width and height for improving the stability of the embankment. This study aims to assess a feasibility of the counter weight filling in the construction of pavement roads for recovery of shear failure during the construction. An effective counter weight filling section was suggested using the numerical analysis. The results showed that the effective counter weight filling section is two-fold (x2) higher than the ratio of width in counter weight filling : embankment height and one third (1/3) to the ratio of height in counter weight filling : embankment height. Also a range of effective trench crossing the counter weight filling required when a trench crossing counter weight filling is installed was suggested by supplying a proper distance between the counter weight filling section and cross-sectional trench.

Aerodynamic Analysis of Counter-Rotating Propfans Around a Missile-Like-Body Using a Frequency Domain Panel Method (주파수영역 패널기법을 사용한 유도무기형태 동체에 장착된 엇회전식 프롭팬의 공력해석)

  • 조진수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.6
    • /
    • pp.1590-1597
    • /
    • 1994
  • The aerodynamic analysis of a $6{\times}6$ counter-rotating propfan around a missile-like-body has been completed analytically using a frequency domain panel method. The present method requires Fourier transformation of flow field around the propfan in computing the velocities normal to the propfan lifting surfaces. The aerodynamic performance curve is determined by angle of attack and nonuniform inflow conditions. The inflow conditions result from the variations of missile flight speed, angle of attack, propfan location relative to control surfaces and control surface deflection angle. The two cases of propfan location relative to control surface, front and behind, are analyzed and the aerodynamic results are presented.

A Numerical Investigation of the Main Rotor Tip-vortex and Counter-rotating Vortex during Hovering Flight (주로터 제자리 비행 시 익단 와류와 Counter-rotating Vortex의 수치적 관찰)

  • Jun, Jonghyuk;Chung, In Jae;Lee, Duck Joo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.10
    • /
    • pp.761-769
    • /
    • 2013
  • Effects of helicopter wakes on helicopter aerodynamics are serious, but the wake configuration is very complicated and hard to predict. The purpose of this study is the detailed observation of wake using numerical methods. Vortex lattice method and freewake method are used to track the vortices in the wake. In this paper, the wake configuration is observed during hovering flight. In the case of hovering flight at the moderate thrust level, besides tip vortex, counter-rotating vortex can be observed at the inboard part of blade. When the vortices move downward, tip vortex and counter-rotating vortex get close and influence to each other. Therefore, vortices are highly distorted due to their own instability.

The Application of New Calibrator[I-125]Set for Equipment Quality Management (장비정도관리에 Calibrator[I-125] Set 적용)

  • Kim, Ji-Na;An, Jae-seok;Won, Woo-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.108-111
    • /
    • 2015
  • Purpose Lately, in accordance with the increasing interest about Healthcare accreditation program and International laboratory accreditation scheme, requirements about the instrument quality management are gradually taking shape. In nuclear medicine In vitro laboratory, the most typical instruments are multi detector gamma counter and automatic dispensing system. Each laboratory continue with the quality control adequate for circumstances. The purpose of this study is to application and establish the new Calibrator[I-125]Set which is efficient at standardization of equipment quality management. Materials and Methods Deviation between detectors were measured with 12 solid samples of the Calibrator[I-125]Set. their activities differ from each other by less than 1%. Multi detector gamma counters are GAMMA-10;Shinjin medics. Inc, Goyansi, Korea(Gamma counter A), SR300;Stratec biomedical systems AG, Gewerbestr, Germany(Gamma counter B) and COBRA II; Packard Instrument Co. Inc, Meriden, USA(Gamma counter C). Evaluation of two automatic dispensing system used A, B liquid tracer of the Calibrator[I-125]Set. After dispensing and counting, calculated using the ratio of the measured value and proposed value. We used solution A for 20, 25ul and solution B for 50, 100ul. Method of data analysis and reference range was provided by kit documentation. Furthermore, we could calculate our counter efficiency indirectly. Results The CV(%) of measured values by Gamma counter A, B, C are 0.34, 0.70, 1.30. Calculated value are 1.05314, 2.10419, 4.08485. Provided reference range is less than 3. A dispensing system's calculated values are 0.986, 0.989, 1.023, 1.017 and B are 0.874, 0.725, 1.021, 0.904. Provided reference range is from 0.95 to 1.05. Also, counter's efficiency are 74.18, 72.79, 74.32% at counter A, B, C and efficiency of the one detector counter is 79.26%. Conclusion If using this Calibrator[I-125]Set after verifying whether quality assurance, is applicable to equipment quality management on behalf of the role of gold standard.

  • PDF

Effects of Counter-rotation Position on Knee/Hip Angulation, Center of Mass Inclination, and Edging Angle in Simulated Alpine Skiing

  • Yoon, Sukhoon;Kim, Jin-Hae;Park, Jae-Hyeon;Ryu, Jiseon;Park, Sang-Kyoon;Kim, Joo-Nyeon
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.2
    • /
    • pp.91-97
    • /
    • 2017
  • Objective: To investigate rotation movement of segment for performing each position and its effect on knee/hip angulation, COM inclination, and edging angle changes. Method: Twelve Alpine skiers (age: $25.8{\pm}4.8years$, height: $173.8{\pm}5.9cm$, weight: $71.4{\pm}7.4kg$, length of career: $9.9{\pm}4.6years$) participated in this study. Each skier was asked to perform counter-rotation, neutral, and rotation positions. Results: Shank and thigh were less rotated in the counter-rotation position than in other positions, whereas the trunk and pelvis were more counter-rotated (p<.05). Hip angulation, COM inclination, and edging angle were significantly greater in the counter-rotation position than in other positions (p<.05). Conclusion: Our finding proved that the counter-rotation position increases hip angulation, COM inclination, and edging angle. Consequently, we suggest that skiers should perform counter-rotation of the trunk and pelvis relative to the ski direction in the vertical axis for the counter-rotation position. Further analysis will continue to investigate the effects of the counter-rotation position in real ski slope with kinetic analysis.

The study on surge detector of digital surge counter for arrester (Arrester용 digital surge counter의 서지 검출 장치에 관한 연구)

  • Kim, Seok-Sou;Choi, Ike-Sun;Cho, Dong-Hwan;Lee, Kang-Sup;Park, Tae-Gon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.170-174
    • /
    • 2005
  • The purpose of this study is to design the digital surge counter for lightning arresters. The used detecting method for surges is using the signal of both ends of ZnO varistor. The electronic detecting parts of the digital counter are arranged in outside of main processer for protecting it from noise. The detecting parts change detected signals into small signals. The countermeasures for noises are (1) Shielding (2) Reinforcement of power circuits (3) Cables & Circ1e core (4) Watch-doc & control of input signals.

  • PDF

고진공에서 이온 카운터를 사용한 실시간 입자 모니터링 시스템의 개발

  • An Gang-Ho;Kim Yong-Min;Yun Jin-Uk;Gwon Yong-Taek
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2006.05a
    • /
    • pp.255-258
    • /
    • 2006
  • In this paper, the new method which is monitoring quantity of particles using by ion-counter has been developed. ISPM system is composed by Gerdien type ion-counter (house-made), DC power supply and electrometer. Ion-counter applied positive voltage could detect only positive charged particles. Therefore charged particles to Boltzmann equilibrium distribution or to some identified charge distribution can be detected by ion-counter. Ion-counter could install on the exhaust line of process equipment since pressure loss is structurally low. ISPM system has been certified by comparison with the result of SMPS (Scanning Mobility Particle Sizer) system. The relation coefficiency is above 0.98 about $20{\sim}300nm$ particles with identified charge distribution under $0.1{\sim}10.0$ Torr.

  • PDF

Counter Weight Design of Multi-stage Reciprocating Air Compressors (다단 왕복동 공기압축기의 평형추 설계)

  • Kim, Young-Cheol;Kim, Byung-Ok;Shin, Hyun-Ik
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.656-661
    • /
    • 2003
  • Modem reciprocating air compressors have tendency to a multi-stage W-type or V-type cylinder arrangement for the purpose of high outlet pressure, compactness and low vibration and noise. A valid counter weight calculation method using the complex expression is proposed for reducing the inertia forces of the compressor. Counter weight removes only 1st forward whirl component. Counter weight formulations are applied to the six various compressor structures which are (a) 1 cylinder single-throw crank shaft, (b) 2 cylinder single-throw crank shaft (c) 2 cylinder double-throw clank shaft, (d) 3 cylinder single-throw crank shaft, (e) 4 cylinder single-throw crank shaft and (f) 4 cylinder double-throw crank shaft. The improvement of performance is verified through available vibration test.

  • PDF