• Title/Summary/Keyword: Counter-current

검색결과 452건 처리시간 0.031초

역류식 충전탑에서 이산화탄소 탈착과 수력학절 거동에 관한 연구 (A Study on Hydraulic Behavior and Desorption of $CO_2$ Gas in the Counter-current Packing Tower)

  • 김석택
    • 환경위생공학
    • /
    • 제15권3호
    • /
    • pp.94-100
    • /
    • 2000
  • This study was carried out to interpret hydraulic behavior and CO2 gas desorption in counter-current packing tower which packed 50mm plastic Hiflow-ring. The results are as follow : To compare with conventional packing, 50mm Hiflow-ring could save energy because of low pressure drop under high load. As relative error between calculated value and investigated value was less than 6% in the loading point and flooding point we found that we are predict results mathematically which occur in packing tower. The unique magnitude of packing which was used are as follows. $C_L=2.1{\times}10^{-4}$, n=0.787 so we can predict efficiency which occur

  • PDF

알팔파의 생리활성물질 분리 및 동정 (SEPARATION, IDENTIFICATION OF BIOACTIVE COMPOUNDS FROM ALFALFA PLANT)

  • 정일민;김기준
    • 분석과학
    • /
    • 제7권3호
    • /
    • pp.403-411
    • /
    • 1994
  • 본 실험은 알팔파의 Allelopathy와 Autotoxicity에 관련되는 생리활성 물질의 분리, 정제, 동정하기 위하여 실시되었다. 알팔파 생잎 1kg을 80% MeOH로 추출하여 silica gel TLC와 DCCC의 분리와 정제과정을 거쳐 HPLC로 동정하였다. HLPC 분석결과 4개의 phenolic 물질(salicylic acid, rutin, quercetin, scopoletin) 등이 동정되었다. 이들 물질을 이용한 발아실험에서도 모두 알팔파의 발아와 생육에 억제적으로 작용하였으며, 이 중 quercetin의 처리가 가장 억제적이었다. 따라서 최소한 이들 물질이 알팔파의 Allelopathy와 Autotoxicity에 관련하는 것으로 생각되었다.

  • PDF

간극에서의 역방향 유동 제한 현상 연구 (Counter-Current Flow Limit in Narrow Gap)

  • 김용훈;서균렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1054-1060
    • /
    • 1998
  • Previous counter-current flow limitation (CCFL) and critical heat flux (CHF) studies included investigations on the inlet entrance, inclined channel and gap effects for the most part. In this study, the local CHF correlation was presented to be used in the numerical analysis for the 3 dimensional hemispherical geometry. Also, first-principle analyses were performed to determine the maximum heat removal capability from the debris through the gap that may be formed during a core melt accident. The maximum heat removal capability by gap cooling can be applied in quantitatively assessing the severe accident management measures.

  • PDF

대향류 채널 소형 열재생 연소기의 화염안정 특성에 관한 실험적 연구 (An Experimental Study on the Characteristics of Flame Stabilization in a Small Heat-Regenerative Combustor of Counter-Current Channels)

  • 조상문;김남일
    • 대한기계학회논문집B
    • /
    • 제31권5호
    • /
    • pp.491-498
    • /
    • 2007
  • Flame characteristics of a methane-air premixed flame stabilized in a heat-regenerative small combustor were investigated experimentally. A small combustor having two counter-current shallow channels and a combustion space at one side was developed. In which the channel-gap was less the ordinary quenching distance of a stoichiometric methane-air premixed flame. Two design parameters of channel gap and thickness of the middle wall, which is located between two channels for unburned and burned gases, were varied. Flame stabilization conditions and characteristic flame behaviors were experimentally examined. Conclusively, Blowout conditions were governed mostly by the scale of the combustion space, and flashback conditions into the channel are dominated by the channel gap. Surface temperatures of the combustor were between 100 to 500$^{\circ}C$. Additionally, two distinctive flame stabilization modes of radiation and well-stirred?reaction were observed and their applicability was discussed.

CNT 및 Pt을 상대전극으로 하는 DSSC의 직병렬연결에 관한 비교특성 (Comparative properties for a serial-parallel connection of DSSC with CNT and Pt counter electrodes)

  • 김희제;김정훈;박성준;최진영;홍지태;이동윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1236-1237
    • /
    • 2008
  • Carbon nanotube(CNT) materials are expected a stable current collector without the phenomena such as oxidizing and melting of grid by redox electrolyte and with low cost. In this paper, two types of dye-sensitized solar cells(DSSCs) with Pt abd CNT as a counter electrode were fabricated, then the energy conversion efficiency characteristics were investigated. The main purpose of this study is to find out the possibility of CNT material as cheap current collector of a large scale DSSC module. In addition, the Hall coefficient were measured by using FCM analysis.

  • PDF

간극에서의 역방향 유동 제한 현상 연구 (Counter-Current Flow Limit in Narrow Gap)

  • 김용훈;서균렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.706-712
    • /
    • 1998
  • Previous counter-current flow limitation (CCFL) and critical heat flux (CHF) studies included investigations on the inlet entrance, inclined channel and gap effects for the most part. In this study, the local CHF correlation was presented to be used in the numerical analysis for the 3 dimensional hemispherical geometry. Also, first-principle analyses were performed to determine the maximum heat removal capability from the debris through the gap that may be formed during a core melt accident. The maximum heat removal capability by gap cooling can be applied in quantitatively assessing the severe accident management measures.

  • PDF

회전식 대향류 반응기 내 열전달 증진을 위한 리프터 설계와 1차원 열평형 모델로의 적용 (Lifter Design for Enhanced Heat Transfer in Rotating Counter-Current Flow Reactor and Application to One Dimensional Heat Balance Model)

  • 이후경;최상민
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2013년도 제46회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.51-54
    • /
    • 2013
  • Rotary kiln reactors are frequently equipped with an axial burner with which solid burden material is directly heated. Lifters are commonly used along the length of the system to lift particulate solids and increase the heat transfer between the solid bed and the combustion gas. The material cascading from the lifters undergoes drying and reacting through direct contact with the gas stream. In this study, volume distribution of materials held within lifters was modeled according to the different lifter configuration and appropriate configuration was used for the design purpose. This was applied to the one-dimensional heat balance model of a counter-current flow reactor, which contributes to the increase of the effective contact surface, and thereby enhances the heat transfer.

  • PDF

간극에서의 역방향 유동 제한 현상 연구 (Counter-Current Flow Limit in Narrow Gap)

  • 김용훈;서균렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.386-392
    • /
    • 1998
  • Previous counter-current flow limitation (CCFL) and critical heat flux (CHF) studies included investigations on the inlet entrance, inclined channel and gap effects for the most part. In this study, the local CHF correlation was presented to be used in the numerical analysis for the 3 dimensional hemispherical geometry. Also, first-principle analyses were performed to determine the Maximum heat removal capability from the debris through the gap that may be formed during a core melt accident. The maximum heat removal capability by gap cooling can be applied in quantitatively assessing the severe accident management measures.

  • PDF

다공판 유로내의 유동한계(CCFL)에 대한 실험적 연구 (The experimental study on the counter-current flow limit in the flow path with a porous plate)

  • 이진기;양승우;권정태;강용태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.176-181
    • /
    • 2006
  • Experiments of Counter-Current Flow Limit(CCFL or Flooding) is performed to improve the drawbacks of Wallis' Correlation which neglects the effects of channel size, channel length, injection method and the boundary conditions at the inlet of liquid and gas phase. In this study, CCFL is observed by changing shape of porous plate using air and water. Results show that as the size of porous increases, CCFL with round shape of the porous plate decreases. In the present study, a CCFL correlation is developed and the CCFL map is proposed based on the present experimental results. developed by this experimental study.

  • PDF

Novel Interface-engineered Junction Technology for Digital Circuit Applications

  • Yoshida, J.;Katsuno, H.;Inoue, S.;Nagano, T.
    • Progress in Superconductivity
    • /
    • 제3권1호
    • /
    • pp.1-4
    • /
    • 2001
  • Interface-engineered junctions with $YbBa_2$$Cu_3$$O_{7}$ as the counter electrode were demonstrated. The junctions exhibited excellent Josephson characteristics with a Josephson critical current ($I_{c}$) ranging from 0.1 mA to 8 mA and a magnetic field modulation of the $I_{c}$ exceeding 80% at 4.2 K while maintaining complete c-axis orientation of the counter-electrode layer. The$ 1\sigma$ spreads in $I_{c}$ for junctions with an average $I_{c}$ of 1-2 mA were 5-8% for 16 junctions within a chip, and 9.3% for a 100-junction array. Our dI/dV measurements suggest that a theoretical approach taking into account both a highly transparent barrier and the proximity effect is required to fully understand the Junction characteristics.ristics.

  • PDF