A Study on Hydraulic Behavior and Desorption of $CO_2$ Gas in the Counter-current Packing Tower

역류식 충전탑에서 이산화탄소 탈착과 수력학절 거동에 관한 연구

  • 김석택 (동아대학교 환경문제연구소)
  • Published : 2000.09.01

Abstract

This study was carried out to interpret hydraulic behavior and CO2 gas desorption in counter-current packing tower which packed 50mm plastic Hiflow-ring. The results are as follow : To compare with conventional packing, 50mm Hiflow-ring could save energy because of low pressure drop under high load. As relative error between calculated value and investigated value was less than 6% in the loading point and flooding point we found that we are predict results mathematically which occur in packing tower. The unique magnitude of packing which was used are as follows. $C_L=2.1{\times}10^{-4}$, n=0.787 so we can predict efficiency which occur

Keywords

References

  1. Packed Towers in Processing and Environment Technology VCH published Inc. R. Billet
  2. UNIT OPERATIONS OF CHEMICAL ENGINEERING Warren L. MaCabe;Julian C. Smith;Peter Harriott
  3. 충전탑 기술 R. Billet;Kim, Jang Ho
  4. 동아대학교 공과대학부설 한국 자원개발연구소 v.13 no.2 충전탐에서 흡수와 탈착에 대한 수력학적인 모델링 김장호
  5. Air Pollution Engineering Manual Anthony J. Buonicore
  6. 구형 망사 충전 흡수탑의 특성 魏延豪
  7. Air Pollution Kenneth Work;Cecil F. Warner
  8. Handbook of Air Pollution Technology John Wiley & Sons. Inc.
  9. 충전 증류탑을 이용한 다성분계의 분리 한국 과학 기술원
  10. Chem. Eng. Technol. Relationship between Reside Time, Fluid Dynamics and Efficiency in Countercurrent Flow Equipment R. Billet
  11. I. Chem. E:Symposium Series No. 104 Schultes, M.;R. Billet