• Title/Summary/Keyword: Count rate

Search Result 862, Processing Time 0.029 seconds

A Low-complexity Mixed QR Decomposition Architecture for MIMO Detector (MIMO 검출기에 적용 가능한 저 복잡도 복합 QR 분해 구조)

  • Shin, Dongyeob;Kim, Chulwoo;Park, Jongsun
    • Journal of IKEEE
    • /
    • v.18 no.1
    • /
    • pp.165-171
    • /
    • 2014
  • This paper presents a low complexity QR decomposition (QRD) architecture for MIMO detector. In the proposed approach, various CORDIC-based QRD algorithms are efficiently combined together to reduce the computational complexity of the QRD hardware. Based on the computational complexity analysis on various QRD algorithms, a low complexity approach is selected at each stage of QRD process. The proposed QRD architecture can be applied to any arbitrary dimension of channel matrix, and the complexity reduction grows with the increasing matrix dimension. Our QR decomposition hardware was implemented using Samsung $0.13{\mu}m$ technology. The numerical results show that the proposed architecture achieves 47% increase in the QAR (QRD Rate/Gate count) with 28.1% power savings over the conventional Householder CORDIC-based architecture for the $4{\times}4$ matrix decomposition.

The Effect of Hyaluronan Treatment in Endotoxemic Rats

  • Rho, Byung-Hak;Kwon, Kun-Young;Choi, Won-Il
    • Tuberculosis and Respiratory Diseases
    • /
    • v.70 no.5
    • /
    • pp.390-396
    • /
    • 2011
  • Background: Hyaluronan (HA) is an unbranched glycosaminoglycan. It has been proposed that HA acts as a vehicle for cytokines due to the strong negative charge on its surface. We hypothesized that HA would function like a cytokine scavenger and reduce the inflammatory signaling cascade and this would lead to improved survival in rats suffering with endotoxemia. Methods: Endotoxin (Salmonella, 10 mg/kg) or an equal amount of 0.9% NaCl (NS) was injected into the jugular vein of rats. HA (1,600 kDa, 0.35%) or NS was given at 0.1 mL/kg/h for 3 hours. HA or NS infusion was started at 4 hour after endotoxin injection. The rats were divided into the control and HA groups (n=16 for each group). The mean arterial pressure (MAP) was monitored during HA or normal saline infusion. Survival was assessed every 12 hours for 3 days throughout the experiment. Results: The survival rate (%) of the rats treated with HA was higher (60%) than that of the controls (20%) when HA was infused 4 hours after lipopolysaccharide (LPS) injection. The bronchoalveolar lavage (BAL) fluid of the animals surviving HA or NS infusion 4 hours after LPS showed that the total cell counts and number of neutrophils were significantly (p < 0.01) reduced in the HA treated groups compared with that of the controls (total cell count, $9.2{\times}10^4$/mL vs. $61{\times}10^4$/mL; neutrophils, $21{\times}10^4$/mL vs. $0.2{\times}10^4$/mL, respectively). There was no significant MAP difference between the HA or control groups either with or without endotoxin. Conclusion: Infusion of hyaluronan (1,600 kDa) reduced the BAL total cell count and the number of neutrophils and it improved the survival rate of the endotoxemic rats.

A survey on hygiene management for raw by-products of beef in Gwangju area, Korea (광주지역 생식용 소 부산물의 위생관리 실태 조사)

  • Kim, Ji-Yeon;Jang, Mi-Sun;Koh, Ba-Ra-Da;Ji, Tea-Kyung;Sung, Chang-Min;Park, Da-Hae;Kim, Hyun-Joong;Kim, Eun-Sun;Kim, Yong-Hwan
    • Korean Journal of Veterinary Service
    • /
    • v.36 no.3
    • /
    • pp.209-216
    • /
    • 2013
  • A total of 301 samples of bovine liver, spleen and omasum were collected from butchers and restaurants in Gwangju, Korea during 2012 and all samples were subjected to bacteriological examination and antibiotic residues. Also, this study was performed to survey the consciousness for hygiene of livestock workers who are handling bovine by-products in Gwangju. The detection rate of aerobic plate count (APC) was higher in summer than in other seasons in all by-products (P=0.000). The detection rate of E. coli count was lower in the liver than the spleen and omasum (P=0.000). Twenty four of the samples (8.0%) were contaminated with S. aureus while one spleen sample (0.3%) was contaminated with L. monocytogenes and finally 10 (3.3%) of the liver and omasum samples were contaminated with Cl. perfringens. Five of the twenty-four S. aureus isolates harbored enterotoxin gene. However, the cpe gene of Cl. perfingens was not detected among any of the 10 isolates. Antibiotic residues were not detected in the liver samples. The consciousness survey's results showed that most of them (58.8%) were safe.

Studies on the Diagnosis of Subclinical Mastitis in Cows by the Measurement of the Electrical Conductivity: 1. Comparison of Various Methods of Handling Conductivity Data with the Use of California Mastitis Test and Direct Somatic Cell Count (전기전도도(電氣傳導度) 측정(測定)에 의한 유우(乳牛) 준임상형(準臨床型) 유방염(乳房炎)의 진단(診斷)에 관한 연구(硏究) 1. 전기전도도법(電氣傳導度法)과 간접검진법(間接檢診法)(CMT 및 총체세포수(總體細胞數))과의 비교(比較))

  • Kang, Byong-kyu
    • Korean Journal of Veterinary Research
    • /
    • v.24 no.1
    • /
    • pp.91-98
    • /
    • 1984
  • A total of 466 foremilk from dairy farms in Chonnam district was examined for the subclinical mastitis over a period of one year, using a method of the electrical conductivities(EC); absolute conductivity(AC) and differential conductivity(DC) and quarter difference value(QD), in relation to the California mastitis test(CMT) and the direct somatic cell count(DSCC). The compatibility and efficiency rating between the EC values and the other screening tests was conducted. Obtained results are summarized as follows. 1. A linear relationship was found between the EC values and the CMT scores and direct somatic cell counts and it was found that electrical conductivity measurements were comparable with other screening tests for diagnosing animals with mastitis. 2. Compatibilities between the EC and CMT were 70.4% in AC, 74.6% in DC and 70.7% in QD, and that of the EC and DSCC were 53.0% in AC, 63.1% in DC and 53.2% in QD. On the other hand, relative efficiency ratings of Postle's equation between EC and CMT were 37.3% in AC, 26.5% in DC and 13.6% in QD, and that of the EC and DSCC were 33.1% in AC, 20.2% in DC and 11.9% in QD. 3. In the foremilk samples collected from damaged quarters determined by EC, the false positive rate wart higher than the false negative rate, and consequently tests of EC produced lower compatibility or efficiency rating scores. These tendencies suggested that any factors other than the mastitic condition influencing the EC values might be existed.

  • PDF

Production of spherical granule type yogurt with improving convenience and preservation (편리성 및 저장성이 증진된 구형과립 요구르트 제조)

  • Shin, Myung-Gon
    • Food Science and Preservation
    • /
    • v.24 no.5
    • /
    • pp.559-564
    • /
    • 2017
  • Yogurt contains many microorganisms that are beneficial to human health, and is a probiotic that supplies many nutrients such as calcium and protein. It is difficult to safety preserve for a long time because it possesses a high content of water. To address this problem, powdered "instant" yogurt has been developed, but it has flaws low flowability and solubility. Therefore, yogurt was granulated using a fluidized bed granulator to increase flowability and solubility. The fluidized bed granulator was designed by using response surface methodology (RSM), whose variables were feeding rate (FR), atomization air pressure (AP) and product temperature (PT). After being granulated, the yogurt was analyzed for yield and lactic acid bacteria count. The maximum yield of yogurt granules was 79.42%, at FR of 0.54 mL/min, AP of 2.64 kPa, and PT of $58.18^{\circ}C$, and the colony count for lactic acid bacteria was more than $6log^{10}\;CFU/g$. Therefore, spherical granulation of yogurt using a fluidized bed granulator could be used for making convenient probiotic products with improved flowability and solubility.

A Study on the Effect of Herbal-acupuncture with Gentianae macrophyllase Radix Solution at Joksamni(ST36) on Collagen-induced Arthritis DBA/1J mice (족삼리(足三里) 진구약침이 생쥐의 Collagen-induced Arthritis에 미치는 영향(影饗))

  • Park, Jung-Hyun;Yim, Yun-Kyoung;Lee, Hyun
    • Korean Journal of Acupuncture
    • /
    • v.24 no.3
    • /
    • pp.117-137
    • /
    • 2007
  • Objectives & Methods : The purpose of this study is to observe the effects of Gentianae macrophyllase Radix herbal-acupuncture solution(GR-HAS) at Joksamni(ST36) on Collagen-induced arthritis(CIA) in DBA/1J mice. The author performed several experimental items to analyze arthritis evaluation, change of weight, spleen size and adhesion rate, change of cytokine level, IgG, IgM and anti-collagen II , change of immunocyte count, histological change of CIA mouse joint related with RA. Results : 1. In the GR-HA group, the arthritis index, the incidence of arthritis and joint edema were significantly decreased. 2. In GR-HA group, there were no weight loss and similarly maintained as normal group. Spleen size, adhesion rate and the edema and transformation of knee joint were low and similarly maintained as normal group. 3. In the GR-HA, cytokine level, IgG, IgM and anti-collagen II were significantly decreased. 4. In the GR-HA, the change of immunocyte count were similarly maintained as normal group. 5. In the histological changes of the CIA mouse joint, the cartilage destruction and synovial cell proliferation were decreased in the GR-HA(Hematoxylin and eosin stain). The collagen fiber expressions in the GR-HA were similar with that of the normal group(Masson's Trichrome stain) Conclusions : These results suggest that GR-HA at ST36 has an effect to control immune reaction and suppress inflammation, synovial cell proliferation and cartilage destruction in rheumatoid arthritis.

  • PDF

PDA based Bluetooth Wireless Radiation Counter (PDA기반의 블루투스 무선통신 방사선 측정 장치)

  • Im, Sang-Heui;Park, Dae-Sung;Jin, Gye-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.1
    • /
    • pp.5-10
    • /
    • 2008
  • This study developed a PDA based wireless communication radiation measuring instrument using Bluetooth. The proposed system is composed of Student Radiation Monitor of Vernier using GM (Geiger Mueller) counter tube as a radiation measuring sensor, LabPro of Vernier as a module for data collection, Promi SD 101 of Initium, which can make Bluetooth communication up to 30 m, for wireless data transmission, and HP 5550 embedded with Pocket PC 2003 as OS for data storage and display. Because GM counter tube is used as a radiation measuring sensor, the system cannot measure radiation energy but measures count volume and count rate. When the result of natural radiation measuring by the PDA based system was compared with that by a PC based system, it was found that the proposed system transmits and receives data without distortion.

  • PDF

Automatic Detection of Vehicle Area Rectangle and Traffic Volume Measurement through Vehicle Sub-Shadow Accumulation (차량 그림자 누적을 통한 검지 영역 자동 설정 및 교통량 측정 방법)

  • Kim, Jee-Wan;Lee, Jaesung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.8
    • /
    • pp.1885-1894
    • /
    • 2014
  • There are various high-performance algorithms in the area of the existing VDSs (vehicle detection systems). However, they requires a large amount of computational time-complexity and their systems generally are very expensive and consumes high-power. This paper proposes real-time traffic information detection algorithm that can be applied to low-cost, low-power, and open development platform such as Android. This algorithm uses a vehicle's sub-shadow to set ROI(region of interest) and to count vehicles using a location of the sub-shadow and the vehicle. The proposed algorithm is able to count the vehicles per each roads and each directions separately. The experiment result show that the detection rate for going-up vehicles is 94.1% and that for going-down vehicles is 97.1%. These results are close to or surpasses 95%, the detection rate of commercial loop detectors.

THE CYTOTOXIC EFFECTS OF ROOT CANAL SEALERS ON FIBROBLASTS IN HUMAN PERIODONTAL LIGAMENT (근관 충전용 시멘트의 치주인대 섬유아세포 독성에 관한 연구)

  • Lee, Gwang-Hee;Choi, Ho-Young;Min, Byung-Soon;Park, Sang-Jin;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.1
    • /
    • pp.156-172
    • /
    • 1993
  • The purpose of this study was to evaluate for the cytotoxicity of root canal sealers - Tubliseal, N2, AH26, and Sealapex - on fibroblasts cultivated from human periodontal ligament. Succinate dehydrogenase activity test and $^{51}Cr$ release test were performed to evaluate the shortterm cytotoxicity. According to l,3 and 6 days vital cell count and $^{14}C$-leucine incorporation rate to fibroblasts were evaluated. The results of this study were as follows: 1. In the test of SDH activity by millipore filter method, Sealapex showed mild cytotoxicity but Tubliseal, N2 and AH26 showed severe cytotoxicity. 2. In $^{51}Cr$ release test, Tubliseal was the most cytotoxic sealer tested, and rank ordered the relative cytotoxicity of the other sealers tested as follows: AH26, N2, Sealapex. 3. In the test of viable cell count, cytotoxicity in Tubliseal was continued because vital cell number reduced with time. Because vital cell was not showed in N2 and AH26 at 1 day, it was recognized that N2 and AH26 exhibited severe cytotoxicity. In Sealapex, vital cell number increased remarkably with time, so it showed that cytotoxicity decreased with time. 4. In $^{14}C$-leucine incorporation rate test, protein sythesis was not produced in Tubliseal, N2 and AH26 after 3 days, it showed that cytotoxicity in Tubliseal, N2 and AH26 was severe. Although protein synthesis in Sealapex decreased with time, it continued after 6 days. Therefore Sealapex has been exhibited mild cytotoxicity.

  • PDF

A Study on the Optimal Position for the Secondary Neutron Source in Pressurized Water Reactors

  • Sun, Jungwon;Yahya, Mohd-Syukri;Kim, Yonghee
    • Nuclear Engineering and Technology
    • /
    • v.48 no.6
    • /
    • pp.1291-1302
    • /
    • 2016
  • This paper presents a new and efficient scheme to determine the optimal neutron source position in a model near-equilibrium pressurized water reactor, which is based on the OPR1000 Hanul Unit 3 Cycle 7 configuration. The proposed scheme particularly assigns importance of source positions according to the local adjoint flux distribution. In this research, detailed pin-by-pin reactor adjoint fluxes are determined by using the Monte Carlo KENO-VI code from solutions of the reactor homogeneous critical adjoint transport equations. The adjoint fluxes at each allowable source position are subsequently ranked to yield four candidate positions with the four highest adjoint fluxes. The study next simulates ex-core detector responses using the Monte Carlo MAVRIC code by assuming a neutron source is installed in one of the four candidate positions. The calculation is repeated for all positions. These detector responses are later converted into an inverse count rate ratio curve for each candidate source position. The study confirms that the optimal source position is the one with very high adjoint fluxes and detector responses, which is interestingly the original source position in the OPR1000 core, as it yields an inverse count rate ratio curve closest to the traditional 1/M line. The current work also clearly demonstrates that the proposed adjoint flux-based approach can be used to efficiently determine the optimal geometry for a neutron source and a detector in a modern pressurized water reactor core.