• Title/Summary/Keyword: Count rate

Search Result 862, Processing Time 0.027 seconds

Evaluation of Hygienic Status of University Foodservice Operation using ATP bioluminescence Assay (ATP bioluminescence Assay를 이용한 대학 급식시설의 위생상태 평가에 관한 연구)

  • 박영숙
    • Korean journal of food and cookery science
    • /
    • v.16 no.2
    • /
    • pp.195-201
    • /
    • 2000
  • An investigation was conducted to evaluate the hygienic status of university foodservice operation by using conventional swabbing technique plus standard plate count and ATP bioluminescence assay. The results of the study were as follows: 1) For all kitchen boards, knives, feeding trays, and dish towels tested, there was an overall agreement at 84.7% level between the results obtained using ATP bioluminescence and plate count when using a pass/fail cut-off of 3$\times$ control values for ATP assay and 40 CFU(colony forming unit)/㎠ for plate count. 2) The agrement rate between ATP assay and standard plate count was 87.5% for the samples before use, 29.2% for those during use, and 42.7% for those after cleaning and sanitizing. 3) The plate counts of three university foodservice operations for kitchen board, kitchen knife, feeding tray and dish towel were within the acceptable limits when tested before using. However, none of them were within the acceptable limits when tested during using and after cleaning and sanitizing. 4) Above results suggested that an immediate action needs to be taken to reduce the potential danger of cross-contamination and also effective sanitary control methods needs to be developed to improve the sanitary condition.

  • PDF

Hardware Design of Rate Control for H.264/AVC Real-Time Video Encoding (실시간 영상 부호화를 위한 H.264/AVC의 비트율 제어 하드웨어 설계)

  • Kim, Changho;Ryoo, Kwangki
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.12
    • /
    • pp.201-208
    • /
    • 2012
  • In this paper, the hardware design of rate control for real-time video encoded is proposed. In the proposed method, a quadratic rate distortion model with high-computational complexity is not used when quantization parameter values are being decided. Instead, for low-computational complexity, average complexity weight values of frames are used to calculate QP. For high speed and low computational prediction, the MAD is predicted based on the coded basic unit, using spacial and temporal correlation in sequences. The rate control is designed with the hardware for fast QP decision. In the proposed method, a quadratic rate distortion model with high-computational complexity is not used when quantization parameter values are being decided. Instead, for low-computational complexity, average complexity weight values of frames are used to calculate QP. In addition, the rate control is designed with the hardware for fast QP decision. The execution cycle and gate count of the proposed architecture were reduced about 65% and 85% respectively compared with those of previous architecture. The proposed RC was implemented using Verilog HDL and synthesized with UMC $0.18{\mu}m$ standard cell library. The synthesis result shows that the gate count of the architecture is about 19.1k with 108MHz clock frequency.

Optimal Number of Failures before Group Replacement under Minimal Repair

  • Young Kwan, Yoo
    • Journal of the Korea Safety Management & Science
    • /
    • v.6 no.1
    • /
    • pp.61-70
    • /
    • 2004
  • In this paper, a group replacement policy based on a failure count is analysed. For a group of identical repairable units, a maintenance policy is performed with two phase considerations: a repair interval phase and a waiting interval phase. Each unit undergoes minimal repair at failure during the repair interval. Beyond the interval, no repair is made until a number of failures. The expected cost rate expressions under the policy is derived. A method to obtain the optimal values of decision variables are explored. Numerical examples are given to demonstrate the results.

Vehicle Arbitration by Dynamic Random Delay Counter Method (동적 랜덤지연계수법에 의한 차량 중재 기법)

  • 장명덕;서재홍김용득
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.747-750
    • /
    • 1998
  • This paper deals with the vehicle arbitration algorithm used in communication system between vehicles and a roadside control unit. To Improve the performance of vehicle arbitration, a random delay counter method is taken into account and modified to select the optimal maximum count value according to the vehicle arrival rate. The suggested algorithm is tested by computer simulation andthe enhanced performance was shown. This method could be applied to various systems which include the communications between transponders and a control unit.

  • PDF

Characteristics in W-EDM of Tungsten Carbide (초경합금의 와이어 방전가공에 의한 특성)

  • 맹민재
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.4
    • /
    • pp.7-13
    • /
    • 2001
  • Wire electrical discharge machining experiments in conducted to investigate characteristics of acoustic emission (AE) and electrical discharge energy due to current peak (I$_{p}$), pulse on time($\tau$/on/). The AE signals are obtained with a sensor attached to workpiece side. Machining states are identified with scanning electron microscopy and residual stress analyzer. It is demonstrated that the residual stress provide reliable informations about the machining states. Moreover, machining states can be detected successfully using both the residual stress and AE count rate.e.

  • PDF

Performance of a Compton Suppression Spectrometer of the SNU-KAERI PGAA Facility

  • Sun Gwang Min;Park Chang Su;Choi H.D.
    • Nuclear Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.347-355
    • /
    • 2003
  • The \gamma-ray spectrometer of the PGAA (Prompt Gamma Activation Analysis) facility constructed at HANARO of the Korea Atomic Energy Research Institute was upgraded to the multi-mode spectrometer including the single mode, the Compton suppression mode and the pair mode. The performance of the spectrometer was tested and summarized. The background count rate and the uncertainty of the detection efficiency were reduced greatly in comparison with those before the new installation.

Effect of Exogenous Potassium on the Reduction in Tar, Nicotine and Carbon Monoxide Deliveries in the Mainstream smoke of Cigarettes (가리염 첨가가 궐련 주류연중 타르, 니코틴, 일산화탄소 이행량에 미치는 영향)

  • 안기영;김천석
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.17 no.1
    • /
    • pp.62-67
    • /
    • 1995
  • Deliveries of tar, nicotine and carbon monoxide in mainstream smoke decreased with increment of exogenous potassium content of tobacco. Potassium malate was more effective than potassium nitrate, potassium carbonate, potassium citrate and potassium oxalate for the reduction of carbon monoxide, but potassium nitrate was more effective than potassium palate, potassium carbonat, potassium citrate and potassium oxalate for the reduction of carbon in the case of nicotine. Puff count and burning rate were slightly changed with added potassium salts.

  • PDF

A Study on Comparison of Acoustic Emission, Ultrasonic Testing and Crack Gauge Method in 3-point Bending Testing (3점 굽힘시험에 있어서 AE, 초음파, 크랙게이지법의 비교연구)

  • Han, E.K.;Kim, K.S.;Park, J.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.10 no.1
    • /
    • pp.65-72
    • /
    • 1990
  • Comparison of acoustic emission, ultrasonic testing and crack gauge in 3-point bending testing have been studied. As the results, COD is indirectly assumed by strain gauge rate and grid pitch width when crack gauge grid is out. Acoustic emission is qualitatively able to measure crack growth by total count but ultrasonic testing has a difficulty in measuring it because of echo height fluctuation according to the change and pressure of UT. probe.

  • PDF

Usefulness Evaluation of Artifacts by Bone Cement of Percutaneous Vertebroplasty Performed Patients and CT Correction Method in Spine SPECT/CT Examinations (척추 뼈 SPECT/CT검사에서 경피적 척추성형술 시행 환자의 골 시멘트로 인한 인공물과 CT보정방법의 유용성 평가)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Juyoung;Nam-Kung, Sik;Son, Hyeon-Soo;Park, Sang-Ryoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.49-61
    • /
    • 2014
  • Purpose: With the aging of the population, the attack rate of osteoporotic vertebral compression fracture is in the increasing trend, and percutaneous vertebroplasty (PVP) is the most commonly performed standardized treatment. Although there is a research report of the excellence of usefulness of the SPECT/CT examination in terns of the exact diagnosis before and after the procedure, the bone cement material used in the procedure influences the image quality by forming an artifact in the CT image. Therefore, the objective of the research lies on evaluating the effect the bone cement gives to a SPECT/CT image. Materials and Methods: The images were acquired by inserting a model cement to each cylinder, after setting the background (3.6 kBq/mL), hot cylinder (29.6 kBq/mL) and cold cylinder (water) to the NEMA-1994 phantom. It was reconstructed with Astonish (Iterative: 4 Subset: 16), and non attenuation correction (NAC), attenuation correction (AC+SC-) and attenuation and scatter correction (AC+SC+) were used for the CT correction method. The mean count by each correction method and the count change ratio by the existence of the cement material were compared and the contrast recovery coefficient (CRC) was obtained. Additionally, the bone/soft tissue ratio (B/S ratio) was obtained after measuring the mean count of the 4 places including the soft tissue(spine erector muscle) after dividing the vertebral body into fracture region, normal region and cement by selecting the 20 patients those have performed PVP from the 107 patients diagnosed of compression fracture. Results: The mean count by the existence of a cement material showed the rate of increase of 12.4%, 6.5%, 1.5% at the hot cylinder of the phantom by NAC, AC+SC- and AC+SC+ when cement existed, 75.2%, 85.4%, 102.9% at the cold cylinder, 13.6%, 18.2%, 9.1% at the background, 33.1%, 41.4%, 63.5% at the fracture region of the clinical image, 53.1%, 61.6%, 67.7% at the normal region and 10.0%, 4.7%, 3.6% at the soft tissue. Meanwhile, a relative count reduction could be verified at the cement adjacent part at the inside of the cylinder, and the phantom image on the lesion and the count increase ratio of the clinical image showed a contrary phase. CRC implying the contrast ratio and B/S ratio was improved in the order of NAC, AC+SC-, AC+SC+, and was constant without a big change in the cold cylinder of the phantom. AC+SC- for the quantitative count, and AC+SC+ for the contrast ratio was analyzed to be the highest. Conclusion: It is considered to be useful in a clinical diagnosis if the application of AC+SC+ that improves the contrast ratio is combined, as it increases the noise count of the soft tissue and the scatter region as well along with the effect of the bone cement in contrast to the fact that the use of AC+SC- in the spine SPECT/CT examination of a PVP performed patient drastically increases the image count and enables a high density of image of the lesion(fracture).

  • PDF

The Effect of Geometric Factors When Measuring Standard Count for Radioactive Iodine Thyroid Uptake Rate (표준계수 측정 시 기하학적 요인이 방사성 요오드 갑상선 섭취율에 미치는 영향)

  • Oh, Joo Young;Kim, Jung Yul;Oh, Ki Baek;Oh, Shin Hyun;Kim, Jae Sam;Lee, Chang Ho;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.53-61
    • /
    • 2013
  • Objectives: It is certain that Radioactive iodine thyroid uptake(RAIU) rate should be measured with the standard counts considering the thyroid gland depth in enlarged thyroid patients for the variation from geometric factors. The purpose of this paper is to consider the effects of geometric factors according to detector to source distance and the effective thyroid depth on RAIU rate with experiment test. Materials and Methods: I-131 370 kBq ($10{\mu}Ci$) point source was measured by Captus-3000 thyroid uptake system (Capintec, NJ, USA) with a change Detector-Source Distance from 20 cm to 30 cm at an interval of 1 cm. And we changed the Neck phantom surface-Source Depth in the phantom with 1 cm, 2 cm, 5 cm using the neck phantom in order to reproduce the effective thyroid depth. Results: Every experimental group follows power curve as inverse square curve ($$R2{\geq_-}0.915$$). The average count rates in the case not using a phantom and the every case applied the effective thyroid depth using a phantom was not identical each other. There was significant fluctuations upon the effective thyroid depths applied the effective thyroid depth above 1 cm in $364.4 keV{\pm}10%$ energy ROI (p<0.01). There was not significant difference between the count rates of 1 cm and 2 cm in $364.4keV{\pm}20%$ and $637.1keV{\pm}6.2%$ (p=0.354, p=0.397). In assumed RAIU rate from regression equation, $364.4keV{\pm}20%$ was lower difference than $364.4keV{\pm}10%$ as 6.42% and 5.09% per 1 cm. Every change of count rate upon depth appears decreased line on Linear Regression, but the case of $284.3keV{\pm}10%$ increased only. And also, The graphs of coefficient of variation upon depth increased as straight line on every experimental group. Conclusion: The result appears that application of $364.4keV{\pm}20%$ energy ROI is more suitable for reducing error from the effective thyroid depth. And also, we can estimate the error of 20 cm should be highly reduced than 30 cm for Inverse Square Law. Therefore, If there is not information of the thyroid depth, it is considered that the error from thyroid depth can reduce through set up energy ROIs for $364.4keV{\pm}20%$, and increase Detector-Source Distances.

  • PDF