• Title/Summary/Keyword: Cost efficiency

Search Result 5,311, Processing Time 0.035 seconds

An Application of Optimization method for Efficient Operation of Micro Grid (마이크로그리드의 효율적 운영을 위한 최적화기법의 응용)

  • Kim, Kyu-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.12
    • /
    • pp.50-55
    • /
    • 2012
  • This paper presents an application of optimization method for efficient operation in micro grid. For operational efficiency, the objective function in a diesel generator consists of the fuel cost function similar to the cost functions used for the conventional fossil-fuel generating plants. The wind turbine generator is modeled by the characteristics of variable output. The cost function of fuel cell plant considers the efficiency of fuel cell. Particle swarm optimization(PSO) and sequential quadratic programming(SQP) are used for solving the problem of microgrid system operation. Also, from the results this paper presents the way to attend power markets which can buy and sell power from upper lever grids by connecting a various generation resources to micro grid.

The Analysis of Distribution Characteristic on the Operation Cost for Respective Transport Volume and Travel Speed of New Transit System Bi-Modal Tram (녹색 신교통 시스템 바이모달트램의 수송수요 및 운행속도별 운영비용 분포특성 분석)

  • Bae, Eul-Ho;Kim, Kyung-Man;Shin, Cheol-Ho;Kim, Do-Han;Park, Young-Kon
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.2297-2302
    • /
    • 2010
  • The status and effectiveness of Bi-modal Tram is analyzed through the comparison of the transport effectiveness and operation cost between the public transportation systems (bus, light rail transit) considering the vehicle and operation characteristic of new transit system Bi-modal Tram. The standard operation schedule is established in consideration of the vehicle specification and operation characteristic of main public transportation modes, and then the annual average operation cost is estimated depending on the volume, speed, analysis length for respective public transportation mode. Through analyzing the operation cost and distribution characteristic of public transportation modes depending on the transport volume and travel speed, the operational efficiency suitable for the city is derived. It is concluded that the operational efficiency of Bi-modal Tram is superior to that of the bus and light rail transit on the aspect of travel volume and operation speed.

  • PDF

A Study on the Investment Strategy that improves the Rail-infrastructure Investment Efficiency (철도투자 효율성 향상을 위한 투자전략에 관한 연구)

  • Kim, Seong;Lee, Jong-Gug;Kim, Yoon-Yang
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1574-1586
    • /
    • 2008
  • Railway is the most effective transportation than any other traffic. But due to the its expensive maintenance fee and various components like roadbed, rail, rollingstock, electric and signal etc, the construction cost of the railway is usually higher than highway. Such a reason, a lot of cost and period are needed to complete the railway project. In addition that considering the decreasing of the SOC budget, the investment in the railway industry is getting hard than ever. This study analyzed the cost, term of work, freight & passenger transportation demand of the wide area railway electrification project and main line improvement project. And it compared the estimation value and real value of the projects like cost and period etc. And this study surveyed the economic feasibility including factors which are not considered in the feasibility study guide. With those results, This study suggest the project management and evaluation method to enlarge the efficiency of the railway construction project.

  • PDF

A Study on the Development of Industrial Power Management System (수용가 전력관리시스템 개발 연구)

  • Moon, Young-Hwan;Seong, Ki-Chul;Yoon, Sang-Hyun;Kim, Eon-Chung
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.550-552
    • /
    • 1995
  • Real time informations from industrial power system in operation can be used for efficient energy conservation, optimal operation of electrical equipments, and expansion planning of apparatus. Requirements for energy conservation and supplied power quality in customers are increasing significantly because of their effects on the production cost and efficiency. Thus, the development of low cost power management system which can can operate in domestic power system properly is substantially requested. In this research, operation software for real time monitoring and control system in customer power system has been developed to achieve the above purposes. The development of the operating software and related technologies are expected to be applied successfully for reducing electricity cost, enhancing power quality, determining facility expansion planning, operating optimal power system, increasing production efficiency, and reducing maintenance cost.

  • PDF

Cost-Effective Single Switch Multi-Channel LED Driver

  • Hwang, Sang-Soo;Hwang, Won-Sun;Han, Sang-Kyoo
    • Journal of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.319-326
    • /
    • 2015
  • In this paper, a cost-effective single switch multi-channel LED (light emitting diode) driver is proposed. While conventional LED drivers require as many non-isolated DC/DC converters as the number of LED channels, the proposed LED driver needs only one power switch and several balancing capacitors instead of expensive non-isolated DC/DC converters. Therefore, the proposed driver features a simpler structure, with a lower cost and a higher efficiency. Because its power switch can be turned off under the zero current switching condition, it has very desirable advantages such as improved electromagnetic interference characteristics and high efficiency. Moreover, it uses only a small number of DC blocking capacitors with no additional active devices for the current balancing of multi-channel LEDs. As a result, the proposed driver exhibits high reliability and is cost effective. To confirm the validity of the proposed driver, a theoretical analysis is performed, and design considerations and experimental results obtained from a prototype that is applicable to a 46" LED-TV are presented.

Automated Methodology for Linking BIM Objects with Cost and Schedule Information by utilizing Geometry Breakdown Structure (GBS)

  • Lee, Kwangjin;Jung, Youngsoo
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.637-638
    • /
    • 2015
  • There has been growing interests in life-cycle project management in the construction industry. A lot of attention is given to Building Information Modeling (BIM) which stores and uses a variety of construction information for the life cycle of project management. However, due to the additional workload arising from BIM, its expected effects versus its input costs are still under discussion in practice. As an attempt to address this issue, one of previous studies suggested an automated linking process by developing Standard Classification Numbering System (SCNS) and Geometry Breakdown Structure (GBS) to enhance the efficiency of integration process of BIM objects, cost, and schedule. Though SCNS and GBS facilitates identifying all different dataset, making object sets and linking schedule activities still needs to be manually done without having an automated tool. In this context, the purpose of this paper is to develop and validate a fully automated integration system for 3D-objects, cost, and schedule. A prototype system for single family homes (Hanok) was developed and tested in order to verify its efficiency.

  • PDF

Economic Evaluation of Domestic Photoelectrochemical Hydrogen Production (국내 광전기화학 수소생산의 경제성 평가)

  • Gim, Bong-Jin;Kim, Jong-Wook
    • Journal of Hydrogen and New Energy
    • /
    • v.21 no.1
    • /
    • pp.64-71
    • /
    • 2010
  • This paper deals with an economic evaluation of domestic immersing type photoelectrochemical hydrogen production. We also make some sensitivity analysis of hydrogen production prices by changing the values of input factors such as the initial capital cost, the solar to hydrogen conversion efficiency, and the system duration time. The hydrogen production price of the immersing type photoelectrochemical system was estimated as 8,264,324 won/$kgH_2$. It is expected that the production cost by photoelectrochemical hydrogen production can be reduced to 26,961 won/$kgH_2$ if the solar to hydrogen conversion efficiency is increased to 14%, the system duration time is increased to 20,000 hours, and the initial capital cost is decreased to 10% of the current level. The photoelectrochemical hydrogen production is evaluated as uneconomical at this time, and we need to enhance the solar to hydrogen conversion efficiency and the system duration time as well as to reduce prices of the system facilities.

New Multi-Output LLC Resonant Converter for High Efficiency and Low Cost PDP Power Module

  • Kim Chong-Eun;Moon Gun-Woo;Lee Jun-Young;Oh Kwan-Il;Kwon Joong-Yeol
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.71-74
    • /
    • 2006
  • A new multi-output LLC resonant converter is proposed for high efficiency and low cost plasma display panel (PDP) power module. In the proposed converter, zero-voltage (ZV) turn-on of the primary MOSFETs and zero-voltage (ZC) turn-on and turn-off of the secondary diodes are guaranteed in the overall input voltage and output load ranges. In addition, the primary MOSFETs and the secondary diodes have the low voltage stresses clamped to input and the output voltages, respectively. Therefore, the proposed converter shows the high efficiency due to the minimized switching and conduction losses. Moreover, by employing the transformer with multiple secondary windings, the proposed converter can have multiple outputs, which show the great crossregulation characteristics. Therefore, the proposed converter is suitable for high efficiency and low cost PDP power module.

  • PDF

Classification of Grid Connected Transformerless PV Inverters with a Focus on the Leakage Current Characteristics and Extension of Topology Families

  • Ozkan, Ziya;Hava, Ahmet M.
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.256-267
    • /
    • 2015
  • Grid-connected transformerless photovoltaic (PV) inverters (TPVIs) are increasingly dominating the market due to their higher efficiency, lower cost, lighter weight, and reduced size when compared to their transformer based counterparts. However, due to the lack of galvanic isolation in the low voltage grid interconnections of these inverters, the PV systems become vulnerable to leakage currents flowing through the grounded star point of the distribution transformer, the earth, and the distributed parasitic capacitance of the PV modules. These leakage currents are prohibitive, since they constitute an issue for safety, reliability, protection coordination, electromagnetic compatibility, and module lifetime. This paper investigates a wide range of multi-kW range power rating TPVI topologies and classifies them in terms of their leakage current attributes. This systematic classification places most topologies under a small number of classes with basic leakage current attributes. Thus, understanding and evaluating these topologies becomes an easy task. In addition, based on these observations, new topologies with reduced leakage current characteristics are proposed in this paper. Furthermore, the important efficiency and cost determining characteristics of converters are studied to allow design engineers to include cost and efficiency as deciding factors in selecting a converter topology for PV applications.

Efficiency of Radial Transit Routes (간선-지선 노선체계의 효율성)

  • Park, Jun-Sik;Kho, Seung-Young;Lee, Chung-Won
    • Journal of Korean Society of Transportation
    • /
    • v.26 no.5
    • /
    • pp.227-235
    • /
    • 2008
  • This study analyzed the efficiency of a trunk with branches and a trunk with feeders route system comparing the user cost and operator cost of those route systems. Basically, a trunk with branches is more efficient than a trunk with feeders in the passengers' perspective if the transit system of a trunk and feeders are the same. In the case that the trunk system is hierarchically higher than the feeder system, a trunk with feeders has the competitive edge over a trunk with branches if the saving of travel cost induced by using the trunk line is larger than the increasing waiting and transfer cost. This result is consistent with the previous research by Park et al.(2007c), which analyzed the efficiency of hierarchical structure in a grid transit network. If the travel demand of each origins and destinations is low, increasing headway according to the travel demand can increase passenger load or operating efficiency in a trunk with feeders route system. In this case, a trunk with feeders route system is more prevalent as the operating cost, route length, and number of destinations increases, while it is less prevalent as the transfer cost and passengers' time value of the waiting time increases. In cases that central business district, which is located in the middle of a trunk line, generates travel demand, a trunk with feeders is more efficient than a trunk with branches with the increasing travel demand from and to the CBD. Therefore it can be concluded that to have a dual operating system between CBD and suburban is more efficient than one type transit system. The efficiency of that system can be increased through an efficient transfer system that can reduce the transfer cost.