• Title/Summary/Keyword: Cost/Reliability analysis

Search Result 813, Processing Time 0.038 seconds

Development of multi-colorimeter module for low-cost urinalysis strip readers (저가형 요분석 시스템의 다중 광 검출 모듈개발)

  • Ye, Soo-Young;Jeon, Yong-Uk;Jeong, Do-Un;Jeon, Gye-Rok;Ro, Jung-Hoon
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.387-395
    • /
    • 2008
  • An optic module system is developed adopting multiple colorimetry units for the measurement of multi-pad urinalysis dipsticks. Multiple photometry system instead of moving mechanisms has the advantages of system reliability and simplicity as well as economic aspects due to the recent development of economic color light emitting diodes and stable photo sensors. An integration amplifier with programmable integration time, a current source circuit with selectable and stable current settings were connected through analog multiplexers to thirty light emitting diodes for illumination and ten photo transistors for reading each strip pad. All the circuits are controlled by a microprocessor through a simple set of serial communication commands. The detect ability is eighteen times better than the minimum color difference of the test grading which is 0.013 in urobilinogen in the color space defined in this paper.

Vital Area Identification Analysis of A Hypothetical Nuclear Facility Using VIPEX (VIPEX를 이용한 가상 원자력시설의 핵심구역 파악 분석)

  • Lee, Yoon-Hwan;Jung, Woo-Sik;Lee, Jin-Hong
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.4
    • /
    • pp.87-95
    • /
    • 2011
  • The urgent VAI(Vital Area Identification) method development is required since 'The Act of Physical Protection and Radiological Emergency' that is established in 2003 requires an evaluation of physical threats in nuclear facilities and an establishment of physical protection in Korea. The KAERI(Korea Atomic Energy Research Institute) has developed the VAI methodology and VAI software called as VIPEX(Vital area Identification Package EXpert) for identifying the vital areas. This study is to demonstrate the applicability of KAERI's VAI methodology to a hypothetical facility, and to identify the importance of information of cable and piping runs when identifying the vital areas. It is necessarily needed to consider cable and piping runs to determine the accurate and realistic TEPS(Top Event Prevention Set). If the information of cable and piping runs of a nuclear power plant is not considered when determining the TEPSs, it is absolutely impossible to acquire the complete TEPSs, and the results could be distorted by missing it. The VIPEX and FTREX(Fault Tree Reliability Evaluation eXpert) properly calculate MCSs and TEPSs using the fault tree model, and provide the most cost-effective method to save the VAI and physical protection costs.

Analysis of Safety of the Chemical Facilities by Korea Risk Based-Inspection in the Petrochemical Plant (석유화학공장에서의 한국형 위험기반검사에 의한 화학설비의 안정성 평가)

  • Kim, Tae-Ok;Lee, Hern-Chang;Shin, Pyng-Sik;Choi, Byung-Nam;Jo, Ji-Hoon;Choi, Byung-Young;Park, Sung-Hoo;Kim, Hung-Kun
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.6
    • /
    • pp.35-40
    • /
    • 2007
  • As a way of improving the safety of the chemical facilities, the risk based-inspection(RBI) was executed for the facilities of the applied petrochemical plant using KS-RBI Ver. 3.0 program developed based on the API-581 based resource document(BRD). From an evaluation result of KS-RBI program, we could find the evaluation of the process safety management(PSM) for the applied plant, risk of the applied process, risk of static facilities and pipes, and the demage mechanism of the facilities. Also, we could suggest a proper inspection plan(frequency and method of inspection) using the calculated risk and the status of the facilities. Therefore, the applied plant could be achieved a reduced inspection cost by an extension of inspection frequency, improved productivity, improved reliability of the facilities, and a computerized history management.

A Research Trend on Space Charge Analysis in Polymer Irradiated by Electron Beam (온도 상승시에 전자빔 조사된 폴리머내의 전하 분포의 축퇴 현상 연구 동향)

  • Ko, Sung-Min;Kim, Nam-Yong;Kim, Dae-Yeol;Choi, Yong-Sung;Moon, Jong-Dae;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1992-1993
    • /
    • 2007
  • Decay processes of accumulated charge in e-beam irradiated polymers during elevating temperature are observed using pulsed electro-acoustic measurement system. Since the polymeric materials have many superior properties such as light-weight, good mechanical strength, high flexibility and low cost, they are inevitable materials for spacecrafts. In space environment, however, the polymers sometimes have serious damage by irradiation of high energy charged particles. When the polymers of the spacecraft are irradiated by high energy charged particles, some of injected charges accumulate and remain for long time in the bulk of the polymers. Since the bulk charges sometimes cause the degradation or breakdown of the materials, the investigation of the charging and the decay processes in polymeric materials under change of temperature is important to decide an adequate material for the spacecrafts. By measuring the charge behavior in e-beam irradiated polymer, such as polyimide or polystyrene, it is found that the various accumulation and decay patterns are observed in each material. The results seem to be useful and be helpful to progress in the reliability of the polymers for the spacecraft.

  • PDF

A Survey on Short Duration Interruption Costs in Industrial Customer (산업수용가의 순간정전에 따른 정전비용 검토)

  • Nam K. Y.;Choi S. B.;Ryoo H. S.;Lee J. D.;Jeong S. H.;Kim D. K.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.189-191
    • /
    • 2004
  • This paper presents summary results of direct interview survey of Korean industrial customers conducted to evaluate the direct and short duration interruption costs resulting from local random electrical supply interruptions. The cost is evaluated using the questionnaires authors designed, which are mainly on the experience or preparatory actions consumers Predicted they would take. Economic evaluation of reliability that traditionally takes into account duration and frequency of interruption does not accurately reflect the lost value or economic impacts of industrial customer, especially large size, caused by any kind of interruption. So, to imply the substantial difference in costs incurred by different customer group, the authors apply the international standards, i.e. IEC, IEEE, to the analysis on the interruption costs.

  • PDF

Seismic behavior of isolated bridges with additional damping under far-field and near fault ground motion

  • Losanno, Daniele;Hadad, Houman A.;Serino, Giorgio
    • Earthquakes and Structures
    • /
    • v.13 no.2
    • /
    • pp.119-130
    • /
    • 2017
  • This paper presents a numerical investigation on the seismic behavior of isolated bridges with supplemental viscous damping. Usually very large displacements make seismic isolation an unfeasible solution due to boundary conditions, especially in case of existing bridges or high risk seismic regions. First, a suggested optimal design procedure is introduced, then seismic performance of three real bridges with different isolation systems and damping levels is investigated. Each bridge is studied in four different configurations: simply supported (SSB), isolated with 10% damping (IB), isolated with 30% damping (LRB) and isolated with optimal supplemental damping ratio (IDB). Two of the case studies are investigated under spectrum compatible far-field ground motions, while the third one is subjected to near-fault strong motions. With respect to different design strategies proposed by other authors, results of the analysis demonstrated that an isolated bridge equipped with HDLRBs and a total equivalent damping ratio of 70% represents a very effective design solution. Thanks to confirmed effective performance in terms of base shear mitigation and displacement reduction under both far field and near fault ground motions, as well as for both simply supported and continuous bridges, the suggested control system provides robustness and reliability in terms of seismic performance also resulting cost effective.

A Simplified Steel Beam-To-Column Connection Modelling Approach and Influence of Connection Ductility on Frame Behaviour in Fire

  • Shi, Ruoxi;Huang, Shan-Shan;Davison, Buick
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.4
    • /
    • pp.343-362
    • /
    • 2018
  • A simplified spring connection modelling approach for steel flush endplate beam-to-column connections in fire has been developed to enable realistic behaviour of connections to be incorporated into full-scale frame analyses at elevated temperature. Due to its simplicity and reliability, the proposed approach permits full-scale high-temperature frame analysis to be conducted without high computational cost. The proposed simplified spring connection modelling approach has been used to investigate the influence of connection ductility (both axial and rotational) on frame behaviour in fire. 2D steel and 3D composite frames with a range of beam spans were modelled to aid the understanding of the differences in frame response in fire where the beam-to-column connections have different axial and rotational ductility assumptions. The modelling results highlight that adopting the conventional rigid or pinned connection assumptions does not permit the axial forces acting on the connections to be accurately predicted, since the axial ductility of the connection is completely neglected when the rotational ductility is either fully restrained or free. By accounting for realistic axial and rotational ductilities of beam-to-column connections, the frame response in fire can be predicted more accurately, which is advantageous in performance-based structural fire engineering design.

Ringing Frequency Extraction Method Based on EMD and FFT for Health Monitoring of Power Transistors

  • Ren, Lei;Gong, Chunying
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.307-315
    • /
    • 2019
  • Condition monitoring has been recognized as an effective and low-cost method to enhance the reliability and improve the maintainability of power electronic converters. In power electronic converters, high-frequency oscillation occurs during the switching transients of power transistors, which is known as ringing. The ringing frequency mainly depends on the values of the parasitic capacitance and stray inductance in the oscillation loop. Although circuit stray inductance is an important factor that leads to the ringing, it does not change with transistor aging. A shift in either the inside inductance or junction capacitance is an important failure precursor for power transistors. Therefore, ringing frequency can be used to monitor the health of power transistors. However, the switching actions of power transistors usually result in a dynamic behavior that can generate oscillation signals mixed with background noise, which makes it hard to directly extract the ringing frequency. A frequency extraction method based on empirical mode decomposition (EMD) and Fast Fourier transformation (FFT) is proposed in this paper. The proposed method is simple and has a high precision. Simulation results are given to verify the ringing analysis and experimental results are given to verify the effectiveness of the proposed method.

On the Supplementary Study on DSM-Based Interface Requirements through Analysis of the Operation Scenario of the Urban Subway Logistics System

  • Hwang, Sunwoo;Kim, Joouk;Park, Jaemin;Lee, Sangmin;Kim, Youngmin
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.1
    • /
    • pp.152-161
    • /
    • 2022
  • Recently, it is recognized as a high-cost and inefficient logistics system that increases traffic congestion and environmental problems due to an increase in traffic volume due to the activation of the online market. In order to solve inefficient problems such as unavoidable traffic congestion and environmental problems caused by the increase in traffic volume, it is necessary to develop a freight transport system technology using the existing urban railway infrastructure and freight-only urban railway. The urban subway logistics system is a logistics system that requires a combination of various technologies to solve the nationwide demand for urban logistics and road traffic problems. This paper recognized the existing traffic congestion and environmental pollution of road traffic as problems, and supplemented the contact point requirements presented above by identifying the sub-systems constituting the target system and supplementary points for each part-level contact point. In this study, as a complex system operated for one purpose by grafting various technologies, a plan is required to secure the reliability and safety of operation from various viewpoints. The results of this study can contribute to the initial configuration and basic data to solve the interface bottleneck of the urban subway logistics system to be promoted in the future.

Evaluation of strength characteristics of cement-stabilized soil using the electrical resistivity measurement

  • Kean Thai Chhun;Chan-Young Yune
    • Geomechanics and Engineering
    • /
    • v.33 no.3
    • /
    • pp.261-269
    • /
    • 2023
  • In this study, the compressive strength of cement stabilized soil was predicted using the electrical resistivity measurement. The effects of the water to cement (w/c) ratio and recovered Carbon Black (rCB) contents were examined. A series of electrical resistivity and compressive strength tests were conducted on two types of stabilized soil after 28 days of curing. Multiple nonlinear regression (MNLR) analysis was used to evaluate the relationship between the compressive strength and the electrical resistivity in terms of the rCB, Cu (uniformity coefficient), and w/c ratio. The results showed that the w/c ratio and Cu have a strong influence on the compressive strength and electrical resistivity of the cement stabilized soil compared to the rCB content. The use of a small amount of rCB led to a decrease in the void space in the specimen and was attributed to the increase strength and decrease electrical resistivity. A high w/c ratio also induced a low electrical resistivity and compressive strength, whereas 3% rCB in the cemented soil provided the optimum strength for all w/c ratios. Finally, a prediction equation for the compressive strength using the electrical resistivity measurement was suggested based on its reliability, time effectiveness, non-destructiveness, and cost-effectiveness.