Synthesis and Anti-corrosion Properties of Succinic Acid Alkyl Half-Ester Derivatives (숙신산 알킬 하프-에스테르 유도체의 합성 및 해수에 대한 방청성능)

  • Baek, Seung-Yeob;Kim, Young-Wun;Chung, Keun-Wo;Yoo, Seung-Hyun
    • Applied Chemistry for Engineering
    • /
    • v.22 no.4
    • /
    • pp.367-375
    • /
    • 2011
  • Succinic acid ester derivatives have been used as additives for the base oil of metal working fluids and pressure working oils. In this paper, a series of succinic acid alkyl half-esters were synthesized with over 97% yields by ring-opening reaction of succinic anhydride and fatty alcohol and were soluble in 100 N base oil within 1 wt% concentration. The structures and purities of ester derivatives were confirmed by $^1H-NMR$ and FT-IR spectrum and GC analysis. Anti-corrosion properties of the esters in sea water were evaluated through ASTM D665 method and weight loss method and compared to that of succinic alkyl esters without carboxylic acid group in the molecule. As the results, anti-corrosion properties of succinic acid alkyl half-esters with carboxylic acid group were better than those of succinic acid alkyl esters without carboxylic acid group. And, Anti-corrosion properties of the esters with a shorter alkyl chain of high concentration showed better performance than those with longer alkyl chain of low concentration. Inhibition efficiency % (IE%) of the esters was over 95% in the concentration of 80 ppm and corrosion rate (CR) was below 0.3 mm/year at the same concentration. Thus, the corrosion properties of succinic acid alkyl half-esters result from the carboxylic acid groups in molecules.

Electrochemical Behaviors of Binary Ti-Zr Alloys

  • Oh, M.Y.;Kim, W.G.;Choe, H.C.;Ko, Y.M.
    • Corrosion Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.89-92
    • /
    • 2009
  • Pure Ti as well as Ti-6Al-4V alloy exhibit excellent properties for dental implant applications. However, for a better biocompatibility it seems important to avoid in the composition the presence of V due to the toxic effects of V ion release. Thus Al and V free and composed of non-toxic element such as Nb, Zr alloys as biomaterials have been developed. Especially, Zr contains to same family in periodic table as Ti. The addition of Zr to Ti alloy has an excellent mechanical properties, good corrosion resistance, and biocompatibility. In this study, the electrochemical characteristics of Ti-Zr alloys for biomaterials have been investigated using by electrochemical methods. Methods: Ti-Zr(10, 20, 30 and 40 wt%) alloys were prepared by arc melting and homogenized for 24 hr at $1000^{\circ}C$ in argon atmosphere. Phase constitutions and microstructure of the specimens were characterized by XRD, OM and SEM. The corrosion properties of the specimens were examined through potentiodynamic test (potential range of -1500 ~ 2000 mV), potentiostatic test (const. potential of 300 mV) in artificial saliva solution by potentiostat (EG&G Co, PARSTAT 2273. USA).

Experimental investigation on durability performance of rubberized concrete

  • Guneyisi, Erhan;Gesoglu, Mehmet;Mermerdas, Kasim;Ipek, Suleyman
    • Advances in concrete construction
    • /
    • v.2 no.3
    • /
    • pp.193-207
    • /
    • 2014
  • The study presented herein aims to investigate the durability related properties of rubberized concrete. Two types of waste scrap tire rubber were used as fine and coarse aggregate, respectively. The rubber was replaced with aggregate by three crumb rubber and tire chips levels of 5, 15, and 25% for the rubberized concrete productions. In order to improve the transport properties and corrosion resistance of rubberized concretes, SF was replaced with cement at 10% replacement level by weight of total binder content. The transport properties of the rubberized concretes were investigated through water absorption, gas permeability, and water permeability tests. The corrosion behavior of reinforcing bars embedded in plain and silica fume based rubberized concretes was investigated by linear polarization resistance (LPR) test. The results indicated that the utilization of SF in the rubberized concrete production enhanced the corrosion behavior and decreased corrosion current density values. Moreover, the reduction in the water and gas permeability coefficients was observed by the incorporation of SF in plain and especially rubberized concretes.

Perforrmance Tests of Epoxy-coated Reinforcing Bars : Corrosion Protection Properties (에폭시 도막 철근의 내부식 성능에 관한 실험적 연구)

  • 신영수;홍기섭;최완철
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.6
    • /
    • pp.173-179
    • /
    • 1994
  • Epoxy coated bars protecting reinforcing bars from corrosion and enhancing durability of reinforced concrete structures are tested to evaluate corrosion protection properties. Tests are performed based on the relevant sta.ndards of KS and ASTM, such as chenical resistance, salt water spray, salt crock test and chloride ermeability test. with the main varlable of the coating thlckness. Test results show good chemical protection property and chloride permeability. The results of the salt water spray and the salt crock test show that epoxy coating well protects the reinforcing bars from corrosion, cornparing to the biack bars without epoxy coatmg. However, several spots on the coated bars are rusted at the pinholes or un the bars with coating thickness less thar $200{\mu}M$. Special cautions are required i n the process of blast cleanmg when applying the usion-bonded epoxy coating.

Evaluation of Corrosion Resistance Properties by Applying Galvanostatic Nanoscale Current Density on Passive Metals

  • Na, Seung-Chan;Lee, Jeong-Ja;Yang, Won-Seog;Hwang, Woon-Suk
    • Corrosion Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.7-11
    • /
    • 2007
  • In this study, new evaluation method for the stability and corrosion resistance properties of passive films has been suggested by means of observation of self-activation process in open-circuit state and galvanostatic nanoscale reduction test. The experiments were performed for air-formed oxide film in case of plain carbon steel, and for anodically passivated films formed in aqueous sulfuric acid solutions in case of titanium and 304 stainless steel. From these experimental results, we derived two parameters, $i_{0}$ and $q_{0}$, which characterize the self-activation process and the properties of passive film on a stainless steel surface. The parameter $i_{0}$ was defined as the rate of self-activation, and $q_{0}$, the reduced amount of charge during the self-activation process. In conclusion, it is considered that the stability and corrosion resistance of passive metals and alloys can be evaluated quantitatively by three parameters of $\tau_{0}$, $q_{0}$, and $i_{0}$, which easily obtain by means of observing the self-activation process and galvanostatic nanoscale reduction test.

A study on the corrosive behaviour of Rolling stock structures by electrochemical experiments (전기화학시험에 의한 부식용액별 구조물의 부식 특성 연구)

  • Oh Chang-Rok;Goo Byeong-Chun
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.686-691
    • /
    • 2004
  • The present paper describes an experimental study on the corrosive behaviour of Rolling stock structures. It is important to predict corrosive behaviour of rolling stock structures for safe service and to know relation between corrosion and fatigue life. This paper practiced electrochemical corrosion test of SS400 and SM490A. This study will examine the corrosive properties and differences of SS400 and SM490A from measuring corrosion potential, corrosion current density and corrosion rate.

  • PDF

Corrosion Fatigue of Austenitic Stainless Steel in Different Hot Chloride Solutions

  • Visser, A.;Mori, G.;Panzenbock, M.;Pippan, R.
    • Corrosion Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.172-176
    • /
    • 2015
  • Austenitic stainless steel was investigated under cyclic loading in electrolytes with different chloride contents and pH and at different temperatures. The testing solutions were 13.2 % NaCl (80,000 ppm $Cl^-$) at $80^{\circ}C$and 43 % $CaCl_2$ (275,000 ppm $Cl^-$) at $120^{\circ}C$. In addition to S-N curves in inert and corrosive media, the fracture surfaces were investigated with a scanning electron microscope (SEM) to analyse the type of attack. The experimental results showed that a sharp decrease in corrosion fatigue properties can be correlated with the occurrence of stress corrosion cracking. The correlation of occurring types of damage in different corrosion systems is described.

An experimental study on corrosion properties of reinforcing steel under environment of complex deterioration (표면피복종류에 따른 복합열화환경하의 철근콘크리트 부식특성에 관한 실험적 연구)

  • 조봉석;김영덕;윤종기;김재환;김용로;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.86-89
    • /
    • 2003
  • It is recognized that reinforcement corrosion is the main distress behind the present concern regarding concrete durability. In this study, to confirm corrosion of reinforced concrete affected by thickness of cover, kinds of surface coating, measured electric potential, ratio of corrosion area, weight reduction, corrosion velocity of steel bar under environment of complex deterioration. The results showed that an increase in age also increases corrosion of steel bar. Ratio of corrosion area is largely related to ratio of weight reduction. as well, corrosion of steel bar by thickness of cover is superior to l0mm thick than 20mm thick. It showed that an increase in thickness of cover prevent steel bar from deteriorating. The results of this study showed that corrosion velocity was affected by thickness of cover, kinds of surface coating. data on the development of corrosion velocity made with none, organic B, organic A, inorganic B, and inorganic A is shown.

  • PDF

Effect of stud corrosion on stiffness in negative bending moment region of steel-concrete composite beams

  • Yulin Zhan;Wenfeng Huang;Shuoshuo Zhao;Junhu Shao;Dong Shen;Guoqiang Jin
    • Steel and Composite Structures
    • /
    • v.48 no.1
    • /
    • pp.59-71
    • /
    • 2023
  • Corrosion of the headed studs shear connectors is an important factor in the reduction of the durability and mechanical properties of the steel-concrete composite structure. In order to study the effect of stud corrosion on the mechanical properties in the negative moment region of steel-concrete composite beams, the corrosion of stud was carried out by accelerating corrosion method with constant current. Static monotonic loading was adopted to evaluate the cracking load, interface slip, mid-span deflection, and ultimate bearing capacity of four composite beams with varying corrosion rates of headed studs. The effect of stud corrosion on the stiffness of the composite beam's hogging moment zone during normal service stage was thoroughly examined. The results indicate that the cracking load decreased by 50% as the corrosion rate of headed studs increase to 10%. Meanwhile, due to the increase of interface slip and mid-span deflection, the bending stiffness dropped significantly with the same load. In comparison to uncorroded specimens, the secant stiffness of specimens with 0.5 times ultimate load was reduced by 25.9%. However, corrosion of shear studs had no obvious effect on ultimate bending capacity. Based on the experimental results and the theory of steel-concrete interface slip, a method was developed to calculate the bending stiffness in the negative bending moment region of composite beams during normal service stage while taking corrosion of headed studs into account. The validity of the calculation method was demonstrated by data analysis.

Degradation Properties of Catenary Wires on the Atmospheric Corrosion (대기부식에 의한 가선재의 열화특성)

  • 김용기;장세기;정우성;이덕희
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.590-596
    • /
    • 2002
  • Contact wires are made by metallic materials and exposured at atmosphere. We have investigated mechanical properties and the present condition of air pollution as to the messenger wires and ACSR wires of these contact wires. Mechanical properties between new contact wires and used, the used one's tensile strength and elongations was decreased by effect from corrosion. We observed a fatigue properties which was investigated by fatigue test because contact wires were affected with amplitude vibration everytime the train passed through the railways. In the evaluation of fatigue test, it was also shown that fatigue life of the used wires was decreased 50 ∼ 60% compared with that of new ones in average by effect from corrosion.

  • PDF