• 제목/요약/키워드: Corrosion Inhibitor

검색결과 225건 처리시간 0.022초

에노드형 방청제를 콘크리트중 철근의 부식 억제효과 (Corrosion Protection of Rebar in Concrete Using the Anodic Inhibitor)

  • 문한영;김성수;김홍삼;안기용
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표논문집(II)
    • /
    • pp.229-232
    • /
    • 1998
  • Recently it has become general to use the inhibitor with a view to protecting corrosion of rebars in concrete. As the inhibitors used in construction works are almost made in America or Japan, we immediately need to begin home production of inhibitors. In this paper, to estimate the domestic anodic inhibitor of nitrite in comparison with foreign made inhibitor we made some fundamental experiments of setting time, slump and compressive strength. Besides, we analysed the effect of corrosion protection of inhibitor on the ground of corrosion current, resistance to chloride penetration and diffusion of chloride ingress in concrete.

  • PDF

상수도 배급수관망의 부식방지를 위한 인산염계 방청제 적용에 관한 연구 (Effect of Phosphate-based Inhibitors on Pipe Corrosion of Drinking Water Supply)

  • 이윤진;남상호
    • 한국환경보건학회지
    • /
    • 제29권3호
    • /
    • pp.65-71
    • /
    • 2003
  • The injection concentration of corrosion inhibitor increases under the pH 7, temperature of 2$0^{\circ}C$, and alkalinity of 35 mg/l (as CaCO$_3$), the corrosion rate gradually decreased. When the corrosion inhibitor of 10 mg/l is injected, the corrosion rate for carbon steel pipe, galvanized steel pipe, and copper pipe reduces for 37, 66 and 61 % respectively that it is more efficient on galvanized steel pipe and copper pipe. As a result of examination of corrosion rate at pH 6, 7, and 8 when injecting 10 mg/l of corrosion inhibitor under the conditions of 2$0^{\circ}C$ in water temperature and 35 mg/l (as CaCO$_3$) in alkalinity, the efficiency of the corrosion inhibitor increases as the pH increases. For carbon steel pipe, it does not show much a difference with the change of the pH condition, but galvanized steel pipe and copper pipe clearly show the corrosion rate depending on the change of the pH condition. The efficiency of corrosion inhibitor is low as the concentration of residual chlorine is high, but it does not show a great influence at 0.4 mg/l or less. For each pipe type, in the case of carbon steel pipe, the range of increase of corrosion speed following the residual chloride is higher than the other pipe types. In the meantime, the effect following the residual chlorine in copper pipe is low.

Monitoring of the Content of Imidazoline-Containing Corrosion Inhibitor

  • Zadorozhny, P.A.;Sukhoverkhov, S.V.;Markin, A.N.;Savin, K.I.;Prokuda, N.A.
    • Corrosion Science and Technology
    • /
    • 제16권4호
    • /
    • pp.161-166
    • /
    • 2017
  • The qualitative composition of active components of the corrosion inhibitor CGW-85567 was studied. It was found that С18:2 and С18:1 imidazolines and the corresponding imidazolin-amides are the major components. The HPLC/MS technique was developed for their determination in the water solutions of monoethylene glycol (MEG). Industrial application of the inhibitor showed that MEG solution retained high concentration of the inhibitor for a long time after ceasing its addition into pipelines. Low values of the partition coefficients (0.010-0.014) of imidazolines in the system "water solution of MEG (concentration of MEG 62-85% v/v) - gas condensate" have allowed to pass on from the technology of continuous pumping of the inhibitor into protected pipelines to the periodic dosing technology. Taking into account a long time of circulation in the system and high temperatures during MEG regeneration process possible degradation products of the inhibitor were studied. N, N-dimethyl-dodecanamine-1, and N, N-dimethyl-tetradecanamine-1 were identified as major degradation products of the corrosion inhibitor CGW-85567.

인산염계 부식억제제에 의한 탄소강관의 부식특성 연구 (A study on the corrosion characteristics of carbon steel pipes by phosphate corrosion inhibitor)

  • 우달식;황병기
    • 한국산학기술학회논문지
    • /
    • 제9권2호
    • /
    • pp.493-499
    • /
    • 2008
  • 본 연구는 가정 옥내급수관에 적수 및 탁수 등을 유발하고 철, 구리 등 중금속이 용출될 수 있는 부식 문제 해결을 위해 인산염계 부식억제제를 주입하는 회분식 실험을 통해 옥내급수관으로 가장 많이 사용되고 있는 아연도 강관의 표면 도금이 벗겨진 상태인 탄소강관을 대상으로 주요 수질인자의 변화, 철의 용출농도 변화, 부식도 및 부착도 평가, 시편의 상태를 고찰하였다. 탄소강관에서 부식억제제를 주입하였을때 pH, 전기전도도, 알칼리도, Ca-경도 등의 부식성 수질인자는 약간의 변화가 있었으나, 큰 영향은 없었다. 탁도의 경우 부식억제제를 5 mg $P_2O_5/L$ 주입시 주입하지 않은 것에 비해 약 10배정도 낮게 나타나 부식억제제가 탁도 유발 억제에 큰 효과가 있음을 확인하였다. 부식억제제의 주입농도가 5 mg $P_2O_5/L$일 때까지는 부식억제제 농도가 증가함에 따라 철(Fe) 용출농도와 부식도가 서서히 감소하는 경향을 보였으며, 부식억제제 5 mg $P_2O_5/L$ 주입시 급격히 감소하여 부식억제제를 주입하지 않은 경우보다 각각 약 12.2배, 약 24배의 저감 효과를 보였다. 결론적으로 인산염계 부식억제제 약 5 mg $P_2O_5/L$ 주입은 옥내 급수관 내부 표면에 치밀한 방식 피막을 형성하여 부식제어에 효과가 있을 것으로 판단된다.

Use of Capparis decidua Extract as a Green Inhibitor for Pure Aluminum Corrosion in Acidic Media

  • Al-Bataineh, Nezar;Al-Qudah, Mahmoud A.;Abu-Orabi, Sultan;Bataineh, Tareq;Hamaideh, Rasha S.;Al-Momani, Idrees F.;Hijazi, Ahmed K.
    • Corrosion Science and Technology
    • /
    • 제21권1호
    • /
    • pp.9-20
    • /
    • 2022
  • The aim of this paper is to study corrosion inhibition of Aluminum with Capparis decidua extract. The study was performed in a 1.0 M solution of hydrochloric acid (HCl) and was monitored both by measuring mass loss and by using electrochemical and polarization methods. A scanning electron microscopy (SEM) technique was also applied for surface morphology analysis. The results revealed high inhibition efficiency of Capparis decidua extract. Our data also determined that efficiency is governed by temperature and concentration of extract. Optimum (88.2%) inhibitor efficiency was found with maximum extract concentration at 45 o C. The results also showed a slight diminution of aluminum dissolution when the temperature is low. Based on the Langmuir adsorption model, Capparis decidua adsorption on the aluminum surface shows a high regression coefficient value. From the results, the activation enthalpy (∆H#) and activation entropy (∆S#) were estimated and discussed. In conclusion, the study clearly shows that Capparis decidua extract acted against aluminum corrosion in acidic media by forming a protective film on top of the aluminum surface.

아초산계 방청제 도포에 의한 철근 부식 보수 시스템 공법 개발 (The Development of Repair System for RC Members with Damaged by Rebar Corrosion Using Inhibitor with High Nitrite Content)

  • 이한승;나정일;박순만
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.359-364
    • /
    • 2001
  • The purpose of this study is to develop the repair system for RC members with damaged by rebar corrosion using new corrosion inhibitor which was high nitrite content. In the experiments, the acceleration corrosion test of rebar was conducted using the specimen which was applied by various repair system. As a result, it was confirmed that the new repair system without concrete patching had high anti-corrosion property compared with other repair systems and was very effective as a spray type corrosion inhibitor in concrete containing chloride (0.1% of NaCl).

  • PDF

탄소강관에서의 인산염 부식억제제농도 감소의 반응속도상수 평가 (Adsorption rate of Phosphate Corrosion Inhibitor in Carbon Steel pipe)

  • 우달식;황병기
    • 환경영향평가
    • /
    • 제14권1호
    • /
    • pp.17-24
    • /
    • 2005
  • This study was performed to evaluate the adsorption rate of phosphate corrosion inhibitor and reaction rate constant in drinking water distribution systems. The optimum concentration of corrosion inhibitor would vary depending on the quality of water, pipe materials, and condition of metal surfaces. The current adsorption study indicated that the residual phosphate concentration of the corrosion inhibitor decreased with the time as it adsorbed on the surface of pipe material. As time went by, the residual phosphate concentration became constant. It means that the formation of the corrosion protection film on metal surfaces is completed.

전기화학적 기법을 이용한 콘크리트용 방청제의 성능평가 (Estimation of Corrosion Protection of Inhibitor for Concrete by Electrochemical Techniques)

  • 문한영;김성수;김홍삼;안기용;안재우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표회 논문집(I)
    • /
    • pp.207-210
    • /
    • 1998
  • Recently it has become general to use the inhibitor with a view to protecting corrosion of rebars in concrete. So, it needs to study effect of protection and reasonable dosage of inhibitor to reduce corrosion of rebar in concrete containing chlorides. In this study, we estimate the corrosion rate of rebar in mortar by Tafel extrapolation method, one of electrochemical techniques, and the reasonable dosage of inhibitor for different chlorides environments.

  • PDF

수질제어 및 부식억제제에 의한 상수도관의 내부부식 제어 (Internal Corrosion Control of Drinking Water Pipes by pH and Alkalinity Control and Corrosion Inhibitor)

  • 구성은;우달식;이두진;김주환;안효원;문광순
    • 상하수도학회지
    • /
    • 제20권2호
    • /
    • pp.215-223
    • /
    • 2006
  • The internal corrosion of water distribution systems is the main cause for the problem of the public health threat as well as water leakage in the damaged pipeline, red water, and odor and taste of the tap water. This study was examined the effect of chemicals used for pH and alkalinity control and corrosion inhibitors for producing the optimal corrosion control method. Corrosion study at different pH and alkalinity indicated that these control using alkaline chemicals was effective in corrosion rate, Fe release reduction, but examined to be increased in turbidity and corrosion-by-products(TTHMs) problems. The turbidity was slightly increased, requiring caution in controlling corrosion with $Ca(OH)_2$. At pH 9.0, TTHMs concentration is increased two times corn pared with non-control of pH. Using the pipe which had experienced 28 years of exposure, iron release was decreased with the corrosion inhibitor. Consequently, pH, Alkalinity control method using alkaline chemicals must be complemented by corrosion inhibitor application for efficient corrosion control.

콘크리트 내부로의 압입공법을 사용한 방청제의 침투깊이 및 농도에 관한 실험적 연구 (Experimental Study on the Penetration Depth and Concentration of Corrosion Inhibitor Using Press-in Method Into the Inside of Concrete)

  • 조형규;유조형;이한승
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제13권5호통권57호
    • /
    • pp.160-168
    • /
    • 2009
  • 철근이 부식되면 오염된 콘크리트를 제거하고 철근방식을 하고 보수하는 방법과 방청제를 도포하는 방법으로는 철근위치에서 방청성능을 확보하기가 곤란한 실정이다. 이에 본 연구에서는 철근위치까지 방청제를 고압 침투시키기 위한 연구개발에 앞서 방청제 가압 침투 실험을 통하여 침투깊이를 측정하고 위치별 아질산이온의 양을 측정하여 물시멘트비, 압력, 가압시간에 따른 침투깊이 예측하고 우수한 방청성을 가지는 염화물이온과 아질산이온의 몰비 0.6 이상이 되는 물시멘트비와 압력, 가압시간을 산정하였다. 실험결과 물시멘트비가 방청제의 침투에 가장 큰 영향을 주며 또한 실험체의 깊이가 깊어질수록 침투시킨 방청제의 농도는 같지 않고 낮아지는 것을 알 수 있었다.