• Title/Summary/Keyword: Corrosion Height

Search Result 62, Processing Time 0.026 seconds

Critical Influence of Rivet Head Height on Corrosion Performance of CFRP/Aluminum Self-Piercing Riveted Joints

  • Karim, Md Abdul;Bae, Jin-Hee;Kam, Dong-Hyuck;Kim, Cheolhee;Park, Yeong-Do
    • Corrosion Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.92-101
    • /
    • 2019
  • This study investigates how rivet head height affects the corrosion performance of carbon fiber reinforced plastic (CFRP) to aluminum alloy self-piercing riveted joints. Specimens with two different head heights were prepared. A rivet head protruding out of the top CFRP laminate forms the proud head height while a rivet head penetrating into the top CFRP generates the flush head height. The salt spray test evaluated corrosion performance. The flush head joints suffered from severe corrosion on the rivet head. Thus, the tensile shear load of flush head joints was substantially reduced. Electrochemical corrosion tests investigated the corrosion mechanisms. The deeper indentation of the flush head height damaged the CFRP around the rivet head. The exposure of damaged fibers from the matrix increased the cathodic potential of local CFRP. The increased potential of damaged CFRP accelerated the galvanic corrosion of the rivet head. After the rivet head coating material corroded, a strong galvanic couple was formed between the rivet head base metal (boron steel) and the damaged CFRP, further accelerating the flush rivet head corrosion. The results of this study suggest that rivet head flushness should be avoided to enhance the corrosion performance of CFRP to aluminum alloy self-piercing riveted joints.

State Classification of the Corrosion of Pipes Using a Clustering Algorithm (클러스터링 알고리즘을 이용한 배관의 부식 상태 분류)

  • Cheon, Kang-Min;Shin, Geon-Ho;Hur, Jang-Wook
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.7
    • /
    • pp.91-97
    • /
    • 2022
  • Pipes transport and supply fuel in various categories; however, corrosion occurs because of the external environment, impurities are mixed in the fuel, and substances leak to the outside, which can lead to serious accidents. Therefore, in this study, inspection equipment using a laser scanner was manufactured to classify conditions according to the degree of corrosion of the outer wall of the pipe, and the corrosion height and maximum value of the pipe were obtained from the surface information. Using the k-means method, it was classified into four states, and the standard of the average height and maximum height of corrosion for each state was derived.

Sensitivity analysis of flexural strength of RC beams influenced by reinforcement corrosion

  • Hosseini, Seyed A.;Shabakhty, Naser;Khankahdani, Fardin Azhdary
    • Structural Engineering and Mechanics
    • /
    • v.72 no.4
    • /
    • pp.479-489
    • /
    • 2019
  • The corrosion of reinforcement leads to a gradual decay of structural strength and durability. Several models for crack occurrence prediction and crack width propagation are investigated in this paper. Analytical and experimental models were used to predict the bond strength in the period of corrosion propagation. The manner of flexural strength loss is calculated by application of these models for different scenarios. As a new approach, the variation of the concrete beam neutral axis height has been evaluated, which shows a reduction in the neutral axis height for the scenarios without loss of bond. Alternatively, an increase of the neutral axis height was observed for the scenarios including bond and concrete section loss. The statistical properties of the parameters influencing the strength have been deliberated associated with obtaining the time-dependent bending strength during corrosion propagation, using Monte Carlo (MC) random sampling method. Results showed that the ultimate strain in concrete decreases significantly as a consequence of the bond strength reduction during the corrosion process, when the section reaches to its final limit. Therefore, such sections are likely to show brittle behavior.

Evaluation of Relative Corrosion Rate depending on Local Location and Installation of Structural Member in Steel Water Gate (강재 수문의 부재 위치 및 설치 방향에 따른 상대 부식속도 평가)

  • Ha, Min-Gyun;Jeong, Young Soo;Park, Seung hun;Ahn, Jin-Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.16-24
    • /
    • 2019
  • The corrosion amounts of steel structures can be different depending on their installation condition and height. Thus, their corrosion maintenance should be considered depending on installation conditions of local structural members. In this study, an atmospheric exposure test was conducted to evaluate the corrosion amount and the corrosion rate depending on the installation condition and height of a steel water gate using monitoring steel plates and corrosion environment measuring sensors. The mean corrosion depth was evaluated using the weight loss method and the galvanic corrosion current was measured by corrosion environment measuring sensors. Local corrosion rate of local structural member in steel water gate was estimated using measured mean corrosion depths and galvanic corrosion currents. From this measurement results, the corrosion damage in horizontal member of the cross beam was highly evaluated than those of other structural member as skin plate, etc. The relative difference in the corrosion rate of a local structural member could be highly affected by local corrosion environments of steel water gate members. Therefore, an appropriate maintenance method should be considered for local corrosion damages of local structural members determined by local corrosion environments of a steel water gate.

Corrosion behaviors of cement mortar specimens with different cover thickness in natural sea water

  • Jeong, Jin-A;Jin, Chung-Kuk;Jeong, Eun-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.2
    • /
    • pp.107-111
    • /
    • 2016
  • This paper presents electrochemical corrosion behaviors of cement mortar specimens in the high salinity condition. Chloride ion is known as the most detrimental parameter to cause the corrosion in reinforced concrete. Increasing the concrete cover thickness is one of the corrosion protection methods against chloride ion; so, this study mainly focuses on the effects of mortar cover thickness on corrosion protection. In specimens, rebar, which was a height of 200 mm and a diameter of 10 mm, was installed at the center of the small size form. Later on, mortar was injected into the form, and 10, 20, 30, 40, and 50 mm of the different mortar cover thicknesses were selected. Potential measurements, linear polarization resistance tests, and cyclic potentiodynamic polarization tests were performed for specimens that were exposed to seawater. These results were compared with visual inspection results of rebar. The results show that an increase in the cover thickness contributes to corrosion protection. In addition, the result of electrochemical corrosion tests generally agreed with that of an autopsy visual inspection.

Investigation of Liquid Droplet Impingement Erosion Corrosion based on the Flow Rate of Anodized 5083-H321 Al Alloy in Seawater (경질양극산화된 5083-H321 알루미늄 합금의 해수 내 액적충격침식부식 손상 연구)

  • Shin, Dong-Ho;Kim, Seong-Jong
    • Corrosion Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.310-317
    • /
    • 2020
  • This study investigated the damage to the specimen due to liquid droplet impingement erosion corrosion, which improved the corrosion resistance and durability via hard anodization of 5083-H321 aluminum alloy, which is widely used for small ships and marine structures. The experiment combined liquid droplet impingement erosion and electrochemical equipment with the flow rates in natural seawater solution. Subsequently, Tafel extrapolation of polarization curves was performed to evaluate damage due to the liquid droplet impingement erosion corrosion. The damaged surface was observed using a 3D microscope and a scanning electron microscope. The degree of pitting damage was measured using the Image J program, and the surface hardness was measured using the micro-Vickers hardness tester. The corrosion current density, area, depth, and ratio of the damaged areas increased with the increase in flow rate. The grain size of the damaged area at a flow rate of 20 m s-1 showed fewer and minor differences in height, and a smooth curved shape. The hardness of the damaged surface tended to decrease with increase in flow rate.

Analysis of Chemical Cleaning for the Top-of-Tubesheet of NPP's Steam Generator (원전 증기발생기 관판 상단 화학세정 결과 분석)

  • Lee, Han-Chul;Sung, Ki-Bang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.2043-2048
    • /
    • 2013
  • OPR-1000 CE Steam Generator, of which tube material is composed of Alloy-600 HTMA in nuclear power plant, secondary side is generated ODSCC(Outside Diameter Stress Corrosion Cracking) due to the accumulated sludge. ODSCC is centered around the tube sheet and is being affected depending on the height of the sludge. Chemical cleaning was carried out for a top-of-the-tube sheet(TTS) of Steam Generator in order to decrease corrosive condition of the secondary side of Steam Generator tubes and suppress the occurrence of stress corrosion cracking. The amount of sludge removal was 259.2kg. The height of the accumulated sludge was reduced from 0.71 to 0.34 inches. Corrosion rate as the maximum 2.34 mils was satisfied to within EPRI (Electric Power Research Institute) recommendation(10 mils).

The conservation of a gilt-bronze Sarira Reliquary, Treasure No. 955 (보물 제955호 선암사 금동팔각원당형사리탑 보존처리)

  • Go, Hyeong-Sun;Yu, Jae-Eun
    • 보존과학연구
    • /
    • s.24
    • /
    • pp.215-227
    • /
    • 2003
  • The gilt-bronze Sarira Reliquary was discovered when repairing three-stories east stone pagoda (Treasure No. 395) at Seungju-eup in Suncheon city in Jeollanam-do Province in August, 1986. Then it was appointed as Treasure in 1988. The Sarira Reliquary had been held in Seonamsa temple, but deterioration on the surface and corrosion had appeared affecting its surface detail. Consequently, the conservation treatment was carried out from November 2002 to March 2003.The corrosion and dirt on the surface of the Sarira Reliquary were cleaned with ethyl alcohol and Benzotriazole was applied to prevent further corrosion. Finally, NAD-10(Paraloid NAD-10), acrylic resin, was used to consolidate the structure. Moreover, after non-destructive analysis to confirm element of alloy, copper, gold, silver and mercury were discovered and this result tells us that it was plated with gold by amalgam. Fibers at the pedestal were examined under the microscope and identified as silk. The total height of this Sarira Reliquary is 6.0cm, the height of lotus pedestal and the roof is 2.7cm and 1.8cm, respectively. The roof and body are joined together, and the lotus pedestal can be separated, on which the octagonal reliquary is impaled. The pedestal consists of 3layers of petals and the surface is decorated with flower pattern. The reliquary is presumed to be created in the 14th century, and it becomes valuable historical material to reveal the secret of metal work in the late Goryeo Dynasty.

  • PDF

Turbulent Mass Transfer Around a Rotating Stepped Cylinder - Flow-Induced Corrosion - (후향 계단이 부착된 회전하는 실린더 주위 난류 물질전달 - 유동유발 부식 -)

  • Yoon, Dong-Hyeog;Yang, Kyung-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.9
    • /
    • pp.799-806
    • /
    • 2007
  • Direct Numerical Simulation was carried out to predict mass transfer in turbulent flow around a rotating stepped cylinder. This investigation is a follow-up study of DNS of turbulent flow in Nesic et al. [Corrosion, Vol. 56, No. 10, pp. 1005 - 1014] The original motivation of this work stemmed from the efforts to design a simple device which can generate flows of high turbulence intensity at low cost for corrosion researchers. Two cases were considered; Sc=1 and 10 both at Re=335. Here, Sc and Re stand for Schmidt number and Reynolds number, respectively, based on the step height and the surface speed of the cylinder upstream of the step. Main focus was placed on the correlation between turbulence and mass transfer. The spatio-temporal evolution of concentration field is discussed. The numerical results are qualitatively compared with those of the experiment conducted with a similar flow configuration.

Characteristics on the distribution of salinity of airborne sea salt by height (높이에 따른 비래염분량의 감소 특성)

  • Lee Jong Suk;Choi Won Sung;Kim Do Gyeum;Moon Han Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.261-264
    • /
    • 2005
  • For concrete structures immersed in seawater, the concentration of chloride used to estimate the chloride diffusion coefficient can be defined as the seawater chloride concentration. However, for seashore concrete structures which are not coming into direct contact with seawater, establishing the interface concentration of chloride becomes delicate. In addition, concrete structures are greatly affected by salt attack primarily due to airborne sea salt like it can be seen through the corrosion of rebar. This study intends to investigate characteristics on the salinity of airborne sea salt by height. Salinity measurement devices were installed at height of 2, 10 and 19m on the seashore water tower located in the area of Samchuk in the Eastern coast. Analysis results of the decrease of salinity with respect to the height above the ground at a distance of 30m from the seashore showed that the reduction reached about 40$\%$ at a height of 10m and 60$\%$ at 20m.

  • PDF