• 제목/요약/키워드: Coronary stent

검색결과 84건 처리시간 0.032초

Retrieval of a dislodged and dismounted coronary stent; using a rendezvous and snare technique at the brachial artery level via femoral approach

  • Jeong, Min-Woong;Sohn, Chang-Bae;Kim, Su Hong;Park, Jong-Ik;Park, Se-Ryeong;Min, Jun-Sik
    • Journal of Yeungnam Medical Science
    • /
    • 제33권2호
    • /
    • pp.138-141
    • /
    • 2016
  • Coronary stent dislodgement during percutaneous coronary intervention, which occurs when the stent is passed through tortuous and calcified lesions, is not a rare complication. Without proper treatment, such as fixing with another stent in the coronary artery or removing the undeployed stent from the coronary artery or systemic artery system, this complication can cause serious problems. We experienced the unusual situation of a dismounted and dislodged coronary stent, in which retrograde retrieval to the radial artery was impossible during transradial coronary intervention. We report on use of a rendezvous and snare technique at the brachial artery level via femoral puncture, which resulted in resolution without surgery.

하중 방향에 따른 관상동맥용 스텐트의 유연성 해석 (Flexibile Analysis of Coronary Stents due to Loading Directions)

  • 조승관;조은정;김한성
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.331-334
    • /
    • 2004
  • In clinical use, coronary stents keep coronary arteries open after expansion with a balloon catheter and prevent the expanded artery from collapsing. Coronary stents are positioned in artery by catheter with a balloon along a guide wire to the lesion site. Flexibility is one of important ability for delivery. In this paper, Palmaz-Schatz stent and Tenax complete stent were selected because these are the most representative of tubular stents. Finite element analyses for the stent system were performed using ABAQUS/Standard code. The present study estimated the flexibility of coronary stents due to loading directions. Moreover the present paper suggests a numerical method to test the flexibility of stents. In conclusion this paper shows how the finite element analysis can be effectively organized in the stent development.

  • PDF

Trapped Stent in the Left Coronary Sinus in a Myocardial Infarction Patient

  • Han, Sun;Seo, Pil Won
    • Journal of Chest Surgery
    • /
    • 제48권5호
    • /
    • pp.368-370
    • /
    • 2015
  • Stent entrapment is a very rare complication of percutaneous coronary intervention. The interventional approach could be a treatment strategy. However, if it does not work, surgical treatment should be considered. Here, we report a case of surgical treatment of stent entrapment in the left coronary sinus of a 53-year-old male patient.

Spontaneous resolution of new coronary artery aneurysm following guideline-directed medical therapy after drug-eluting stent implantation

  • Jae-Geun Lee;Ki Yung Boo
    • Journal of Medicine and Life Science
    • /
    • 제20권3호
    • /
    • pp.131-134
    • /
    • 2023
  • Here, we present a case of a 56-year-old man with acute myocardial infarction. The patient underwent percutaneous coronary intervention (PCI) at the left main bifurcation and mid-left anterior descending artery using drugeluting stents. Four months after the PCI, the patient was readmitted for cardiac arrest. Coronary angiography (CAG) revealed stent thrombosis in the left main-to-proximal left anterior descending artery and in-stent restenosis in the left main-to-proximal left circumflex artery. We performed balloon angioplasty at the left main to mid-left anterior descending artery and left main to proximal left circumflex artery stents; subsequently, blood flow was fully restored. However, contrast agent extravasation was observed outside the mid-portion of the left main artery to the proximal left anterior descending artery stent, indicating the presence of a coronary artery aneurysm (CAA) outside the stent. After guideline-directed medical therapy with dual antiplatelet agents and high-intensity statins, follow-up CAG revealed near-resolution of the CAA, absence of stenotic lesions, and good blood flow.

관상동맥 CT 조영술을 활용한 스텐트 재협착 평가: 과거와 현재 최신 동향으로의 여정 (Coronary CT Angiography-Based Assessment of Coronary in-Stent Restenosis: A Journey through Past and Present Trends)

  • 이윤성;박은아;이활
    • 대한영상의학회지
    • /
    • 제85권2호
    • /
    • pp.258-269
    • /
    • 2024
  • 관상동맥병 환자의 치료에 풍선팽창스텐트 치료는 현재 가장 흔히 시행되는 관상동맥재개통 치료법이다. 그러나 경피적 관상동맥 중재술 이후 재협착은 여전히 주요 합병증으로 남아 있다. 스텐트 재협착을 진단하기 위한 도구로서 관상동맥 CT 조영술(coronary CT angiography; 이하 CCTA)는 과거에는 주로 번짐허상과 움직임허상으로 인해 내강을 정확히 판단하기 어려워 그 역할이 제한적이었다. 따라서 정확한 확인을 위해서 침습적인 고식적 관상동맥 조영술로 넘어가는 경우가 많았다. 그러나 근래 CT 기술의 발달로 민감도와 특이도가 모두 개선되면서 그 역할이 중요해지고 있으며, 특히 일관되게 음성예측도가 높게 보고되고 있다. 본 종설에서는 CCTA를 이용한 관상동맥 스텐트 재협착 진단의 과거와 현재, 그리고 최신 동향에 대해 알아보고자 한다.

관상동맥질환 치료를 위한 생체흡수형스텐트의 개발 동향 (The Developing Trend in Bioresorbable Stent for Treatment of Coronary Artery Disease)

  • 정경원;김태훈;나재운;박준규
    • 공업화학
    • /
    • 제29권5호
    • /
    • pp.497-502
    • /
    • 2018
  • 협심증, 심근경색과 같은 관상동맥 질환은 급속도로 증가하고 있다. 관상동맥 질환은 콜레스테롤과 칼슘과 같은 플라크들이 혈관벽에 흡착되어 발생한다. 심혈관 중재시술은 풍선 카테터와 금속스텐트를 이용하여 좁아진 관상동맥혈관을 확장시키는 비수술적 시술방법이다. 금속재질의 스텐트는 관상동맥질환에 의한 사망자를 감소시키는데 효과적이었지만 영구적으로 혈관에 금속재질 스텐트가 이식되어 있기 때문에 지속적인 염증과 후기 혈전증 등이 발생되었다. 따라서, 스텐트와 같은 영구적 보철물에 의한 합병증과 재협착 등을 해결하기 위한 생체 흡수성 혈관 지지체의 개발은 급속도로 증가되고 있다. 이 리뷰에서는 생체흡수형스텐트의 성공적인 개발을 위한 동향에 대해서 논하고자 한다.

관상동맥혈관용 스텐트의 수치해석 및 형상 설계 (Numerical Evaluation and Shape Design of Coronary Artery Stent)

  • 김대영;이승열;김헌영
    • 한국정밀공학회지
    • /
    • 제29권1호
    • /
    • pp.103-108
    • /
    • 2012
  • Restenosis symptom, which is well known as a problem of stents, is due to the recoil and expansion pressure depending on shapes of stent. In order to reduce the effect of recoil problem, study on pattern and shape for the stent is required and the expansion pressure and recoil should be evaluated. This paper aims at evaluating mechanical characteristics of stent used in surgery for vessel stenosis. The expansion process of coronary artery stent in vessel for two models including the Cypher$^{(R)}$ from Johnson & Johnson$^{TM}$ and a suggested model were simulated using the Finite Element Analysis. Comparison of the directional recoil simulation results was made. The issues in the deformed shape of vessel and recoil of Cypher$^{(R)}$ were partially resolved in the suggested model. Therefore, the shape design suggested in this paper was able to reduce the restenosis symptom.

Postinfarct Ventricular Septal Defect after Coronary Covered Stent Implantation

  • Chon, Soon-Ho;Kim, Young-Hak;Kim, Hyuck;Chung, Won-Sang;Kang, Jeong-Ho;Shin, Kyung-Wook
    • Journal of Chest Surgery
    • /
    • 제45권1호
    • /
    • pp.45-48
    • /
    • 2012
  • We report a case of a postinfarction ventricular septal defect caused by an acute recurrent occlusion after the implantation of a covered stent, which was performed as a rescue procedure for the ruptured left anterior descending artery during a percutaneous coronary intervention. Although the emergent implantation of a covered stent for the ruptured coronary arteries such as the left main coronary artery or the origins of the left anterior descending artery can be performed during a percutaneous coronary intervention, and a coronary bypass surgery should be considered in order to decrease the risk of complete occlusion, thus providing a superior long term patency.