Radius Intermedius Stenosis Induced Myocardial Perfusion Defect: Provened by the Fusion Images of Myocardial Perfusion SPECT and 64 Channel CTA (심근관류 SPECT와 64채널 전산화 단층혈관 촬영 사진 융합으로 증명된 radius intermedius 협착에 의한 심근관류 저하)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Chun, Kyung-Ah;Won, Kyu-Chang;Lee, Hyung-Woo;Park, Jong-Seon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.1
    • /
    • pp.77-78
    • /
    • 2008
  • A 71-year-old woman was assigned to our department for Tc-99m myocardial perfusion SPECT(MPS) and coronary CT angiography. She admitted for substernal pain, via the ER, 2 days ago. The heart was scanned after intravenous injection of 925 MBq of $^{99m}Tc$-sestamibi adenosine-induced stress SPECT using dual head gamma camera (Hawkeye, GE healthcare. USA). The MPS shows decreased tracer uptake in the apical & mid area of anterior & lateral wall and mid & basal inferior wall. Coronary CT angiograph was obtained using Discovery VCT (GE healthcare). 3D angiography portrayed significant stenosis of ramus intermedius(RI) and posterolateral branch of right coronary artery(PLB) with fibrocalcified plaque. Two images were fused using Cardiac IQ fusion softwear package (Advantage workstation 4.4, GE healthcare) The fusion images explain the perfusion defect of anterior, lateral and inferior wall is due to stenosis of the RI and PLB. And 3 days later, coronary angiography was done and revealed the marked stenosis of RI and PLB. Then balloon angioplasty and stent was instituted in RI. Cardiac SPECT/CT fusion imaging provides additional information about hemodynamic relevance and facilitates lesion interpretation by allowing exact allocation of perfusion defects to its subtending coronary artery.

Thermal Process for Enhancing Mechanical Strength of PLGA Nanoparticle Layers on Coronary Stents

  • Joo, Jae-Ryang;Nam, Hye-Yeong;Nam, So-Hee;Baek, In-Su;Park, Jong-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.9
    • /
    • pp.1985-1988
    • /
    • 2009
  • Poly (lactic-co-glycolic acid) (PLGA) nanoparticles loading paclitaxel have been deposited on coronary stents by self-assembling properties of colloidal particles. The layers of the nanoparticles were enhanced to a sufficient mechanical strength by a thermal process under the proper temperature and humidity conditions. In vitro release studies proved the controlled paclitaxel release of the nanoparticle layers. This technique gives rise to a new range of applications for nanoparticles and drug-eluting stents.

Urgent Recanalization with Stenting for Severe Intracranial Atherosclerosis after Transient Ischemic Attack or Minor Stroke

  • Park, Tae-Sik;Choi, Beom-Jin;Lee, Tae-Hong;Song, Joon-Suk;Lee, Dong-Youl;Sung, Sang-Min
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.4
    • /
    • pp.322-326
    • /
    • 2011
  • Objective : Stenting of symptomatic intracranial stenosis has recently become an alternative treatment modality. However, urgent intracranial stenting in patients with intracranial stenosis following a transient ischemic attack (TIA) or minor stroke is open to dispute. We sought to assess the feasibility, safety, and effectiveness of urgent intracranial stenting for severe stenosis (>70%) in TIA or minor stroke patients. Methods : Between June 2009 and October 2010, stent-assisted angioplasty by using a balloon-expandable coronary stent for intracranial severe stenosis (>70%) was performed in 7 patients after TIA and 5 patients after minor stroke (14 stenotic lesions). Technical success rates, complications, angiographic findings, and clinical outcomes were retrospectively analyzed. Results : Stenting was successful in all 12 patients. The mean time from symptom onset to stenting was 2.1 days (1-8 days). Post-procedural angiography showed restoration to a normal luminal diameter in all patients. In-stent thrombosis occurred in one patient (n=1, 8.3%), and was lysed with abciximab. No device-related complications, such as perforations or dissections at the target arteries or intracranial hemorrhaging, occurred in any patient. The mortality rate was 0%. No patient had an ischemic event over the mean follow-up period of 12.5 months (range, 7-21 months), and follow-up angiography (n=7) revealed no significant in-stent restenosis (>50%). Conclusion : Urgent recanalization with stenting is feasible, safe, and effective in patients with TIA or acute minor stroke with intracranial stenosis of ${\geq}$ 70%.

Comparison between Basic and Inverse Dual Drug and Peptide-coated Stents in a Porcine Restenosis Model

  • Jang, Eun-Jae;Lee, So-Youn;Bae, In-Ho;Park, Dae Sung;Jeong, Myung Ho;Park, Jun-Kyu
    • Applied Chemistry for Engineering
    • /
    • v.31 no.5
    • /
    • pp.502-508
    • /
    • 2020
  • Dual drug-eluting stents (DES) is a primary treatment method for coronary arterial diseases in current interventional cardiology practice. However, their pathological results according to the sequence of coating of drugs have not been reported yet. The peptide-dopamine dissolved in acetonitrile was coated onto the Chonnam National University Hospital (CNUH) stent using an electrospinning coating machine. For secondary coating (e.g., sirolimus coating, designated as SPS), sirolimus (SRL) and poly lactic-glycolic acid (PLGA) were mixed in tetrahydrofuran (THF), and the solution was then coated on the CNUH stent that had underwent the primary peptide coating using an electrospinning and spray technique. Next, the peptide-dopamine was coated on the SRL-PLGA coated stent (PSS). In this study, it was confirmed that endothelialization was promoted without being significantly affected by the coating order (SPS or PSS). The sequence of drug and peptide coating may affect the development of restenosis and PSS was effective in the prevention of restenosis compared to that of using SPS.

Edge Extraction using Fuzzy Techniques in Coronary Artery Image (Fuzzy 기법을 이용한 관상동맥영상의 에지추출)

  • Kim, Seong-Hu;Lee, Ju-Won;Kim, Joo-Ho;Lee, Han-Wook;Jung, Won-Geun;Lee, Gun-Ki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.3
    • /
    • pp.585-590
    • /
    • 2012
  • Coronary Intervention treatment has become the core that is the test of cardiac catheterization to conduct treatment with Coronary Arteriography. Operators must be careful in Coronary Intervention treatment because the stent is inserted into the point of narrowing of blood vessel. So, the operator must correctly recognize the path of blood vessel to deal with the problems which are damages and ruptures of blood vessel, and there would be some errors of finding the path of blood vessel by bad qualify of the image. Therefore in this paper, median filtering is conducted by preprocessing to evaluate the performance of the effect of noise of the image that affects quality of the image and Fuzzy Edge Extraction Techniques is tested by using Soble Edge Extraction Techniques to compare the performance with The Fuzzy Edge Extraction Techniques. In result, the performance, removing the noise and extracting the signal of Fuzzy Edge Extraction Techniques using median filtering, demonstrates the superiority.

Analysis on the Determinants of Therapeutic Materials Expenditure in National Health Insurance (주요 치료재료 품목군의 건강보험청구액 결정요인분석)

  • Byeon, Jin Ok;Lee, Ju Hyang;Kim, Yu Ri;Lee, Hye Jae
    • Health Policy and Management
    • /
    • v.26 no.4
    • /
    • pp.333-342
    • /
    • 2016
  • Background: The use of therapeutic materials based on new health technology has increased in recent years in the field of medicine, raising concerns for medical practitioners regarding increased spending on the new therapeutic materials amid the rapid population ageing and increase of chronic diseases in Korea. While therapeutic materials have significant importance in the health care system, they have not been given appropriate attention in the academic world of Korea. The purpose of this study is to identify factors that affect the growth of expenditure on therapeutic materials and to derive implications for an effective management considering the diversity of therapeutic materials. Methods: Using the claims data of the National Health Insurance Services, specific utilization patterns of groups of therapeutic materials in the middle classification level of Health Insurance Review and Assessment Service from 2007 to 2014 were analyzed. Four categories (J5083: drug eluting coronary stent, D0302: nonmetallic anchor, K6014: gauze, K6023: gauze) that exhibit unique patterns with respect to price and volume were selected. Then, decomposition analysis was performed to identify the largest contributor to the spending growth by dividing the products into existing, new, and abandoned products for the period between 2010 and 2013. Results: The effect of new products had larger impact on spending growth than the effect of core items in drug eluting coronary stent (J5083) and nonmetallic anchor (D0302). In addition, existing products in general included items priced relatively lower when compared with another item manufactured by the same company. In the gauze category, however, existing products had the largest impact on expenditure and the effect of volume was greater than that in other categories. Conclusion: This study provides evidence that appropriate management measures classified by the characteristics of therapeutic materials are required for therapeutic materials pricing and reassessment in Korea.

Complete Versus Culprit-Only Revascularization for ST-Segment Elevation Myocardial Infarction and Multivessel Disease in the 2nd Generation Drug-Eluting Stent Era: Data from the INTERSTELLAR Registry

  • Kwon, Sung Woo;Park, Sang-Don;Moon, Jeonggeun;Oh, Pyung Chun;Jang, Ho-Jun;Park, Hyun Woo;Kim, Tae-Hoon;Lee, Kyounghoon;Suh, Jon;Kang, WoongChol
    • Korean Circulation Journal
    • /
    • v.48 no.11
    • /
    • pp.989-999
    • /
    • 2018
  • Background and Objectives: We aimed to compare outcomes of complete revascularization (CR) versus culprit-only revascularization for ST-segment elevation myocardial infarction (STEMI) and multivessel disease (MVD) in the $2^{nd}$ generation drug-eluting stent (DES) era. Methods: From 2009 to 2014, patients with STEMI and MVD, who underwent primary percutaneous coronary intervention (PCI) using a $2^{nd}$ generation DES for culprit lesions were enrolled. CR was defined as PCI for a non-infarct-related artery during the index admission. Major adverse cardiovascular event (MACE) was defined as cardiovascular (CV) death, non-fatal myocardial infarction, target lesion revascularization, or heart failure during the follow-up year. Results: In total, 705 MVD patients were suitable for the analysis, of whom 286 (41%) underwent culprit-only PCI and 419 (59%) underwent CR during the index admission. The incidence of MACE was 11.5% in the CR group versus 18.5% in the culprit-only group (hazard ratio [HR], 0.56; 95% confidence interval [CI], 0.37-0.86; p<0.01; adjusted HR, 0.64; 95% CI, 0.40-0.99; p=0.04). The CR group revealed a significantly lower incidence of CV death (7.2% vs. 12.9%; HR, 0.51; 95% CI, 0.31-0.86; p=0.01 and adjusted HR, 0.57; 95% CI; 0.32-0.97; p=0.03, respectively). Conclusions: CR was associated with better outcomes including reductions in MACE and CV death at 1 year of follow-up compared with culprit-only PCI in the $2^{nd}$ generation DES era.

Analysis of Risk Factors in Coronary Artery Bypass Surgery (관동맥우회술의 위험인자 분석)

  • 정태은;한승세
    • Journal of Chest Surgery
    • /
    • v.31 no.11
    • /
    • pp.1049-1055
    • /
    • 1998
  • Background: Coronary artery bypass surgery is an important treatment for ischemic heart disease. Recently operative mortality and morbidity has decreased, however further improvement is necessary. Materials and methods: This study was designed to evaluate the risk of operative mortality and morbidity by retrospective method. From 1992 to 1997, eighty six patients underwent coronary artery bypass surgery. There were 61 males and 25 females aged 36~74 years(mean, 58.6). Fourteen patients(16%) had previous PTCA or stent insertion, 41 patients(48%) had unstable angina, and 45 patients(52%) had three vessel disease. Patients with low LV ejection fraction(<35%) were 7 cases and urgent or emergent operation were 10 cases. There were 6 cases of combined surgery which were mitral valve replacement(2 cases), aortic valve replacement(2 cases), ASD repair(1 case), and VSD repair(1 case). Average number of distal anastomosis was 3.5 per patient and average aortic cross clamp time was 115±38.3min. Preoperative risk factors were defined as follows: female, old age(>70 years), low body surface area(<1.5M2), PTCA or stent insertion history, hypercholesterolemia, smoking, hypertension, DM, COPD, urgent or emergent operation, left main disease, low LV ejection fraction(<35%), and combined surgery. Results: Operative mortality was 7cases(8%). As a postoperative morbidity, perioperative myocardial infarction was 6 cases, cerebrovascular accident 6 cases, reoperation for bleeding 5 cases, acute renal failure 4 cases, gastrointestinal complication 3 cases, and mediastinitis 3 cases. In the evaluation of operative risk factors, low body surface area, DM and low LV ejection fraction were found to be predictive risk factors of postoperative morbidity(p<0.05), and low ejection fraction was especially a risk factor of hospital mortality(p<0.05). Conclusions: In this study, low body surface area, DM and low LV ejection fraction were risk factors of postoperative morbidity and low ejection fraction was a risk factor of hospital mortality.

  • PDF

Comparison of the One-year Follow-up Results after Coronary Bypass Surgery versus Percutaneous Coronary Intervention with Drug-eluting Stents in Patients with Left Main Coronary Artery Disease (좌주간지 병변에 대한 약물방출스텐트시술과 관상동맥우회수술의 1년 추적결과 비교)

  • Choi, Jin-Ho;Lim, Cheong;Park, Kay-Hyun;Chung, Eui-Suk;Chung, Woo-Young;Chae, In-Ho;Choi, Dong-Ju
    • Journal of Chest Surgery
    • /
    • v.41 no.2
    • /
    • pp.210-215
    • /
    • 2008
  • Background: Drug-eluting stents are contributing to the exponential growth of percutaneous coronary intervention, and even in the patients with left main coronary artery disease, owing to the decreased restenosis rate. Our study aimed at comparing the one-year results after coronary artery bypass grafting versus percutaneous coronary intervention with drug-eluting stents in patients with left main coronary artery disease. Material and Method: Those patients who underwent coronary bypass surgery or stenting at our hospital under the diagnosis of left main coronary artery disease were divided in two groups. The variables for comparison were the preoperative disease severity, the length of the hospital stay, the early mortality and the cumulative incidence of mortality, myocardial infarction and repeated revascularization. Result: There were 101 cases in the surgery group and 78 cases in the stent group. Age, gender, the risk factors, the left ventricular ejection fraction and the proportion of acute coronary syndrome showed no significant differences between the two groups. The surgery group showed a more severe condition according to the Euroscore, a greater incidence of urgency, a longer hospital stay and a greater incidence of multi-vessel disease. The early mortality and one-year cumulative mortality were not different between the groups. The Euroscore-matched comparison for the surgery group (41 patients) and the stent group (78 patients) showed no significant differences in the Euroscore, age, gender, risk factors and the proportion of acute coronary syndrome. The surgery group in the Euroscore-matched comparison showed more multi-vessel disease and a longer hospital stay. The surgery group showed lower early mortality and lower one-year cumulative mortality, but this was statistically insignificant (0% vs 2.6%, respectively, p=0.55; 0% vs 6.6%, respectively, p=0.30). The rates of repeated revascularization and major adverse events (death or myocardial infarct) were lower in the CABG group, but this was not statistically significant (13.3% vs 6.3%, respectively, p=0.48; 10.0% vs 0%, respectively, p=0.09). Conclusion: Percutaneous coronary intervention using drug-eluting stents in low-risk patients with left main coronary artery disease resulted in a shortened length of the hospital stay, as compared with that of the CABG group of patients. However, the patients who underwent percutaneous coronary intervention using drug-eluting stents showed a tendency for an increased rate of repeated revascularization and higher one-year cumulative mortality. Further studies with large populations and longer follow-up will be necessary to reaffirm our findings.