• Title/Summary/Keyword: Corona test

Search Result 132, Processing Time 0.028 seconds

A Study of Corona Discharge in Polymer Insulators by Artificial UV Radiation (인위적인 자외선 조사량에 따른 폴리머애자에서의 코로나 방전 특성)

  • Kim, Y.S.;Choi, M.I.;Kim, C.M.;Bang, S.B.;Shong, K.M.;Kwag, D.S.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.5
    • /
    • pp.643-648
    • /
    • 2013
  • In this study, degradation was observed by irradiating UV rays to the polymer insulators which have been widely used in outdoor electric power facilities. For an indoor accelerated UV test, 0.55 w/m2 of UV rays were applied using a xenon-arc method. A UV detection system with 65 ${\phi}mm$ in diameter, 100 mm in length and 1.0 of brightness (F/#) has been designed. Even though efflorescence on the surface of polymer insulators wasn't observed according to the accelerated UV test. UV rays were detected at around 50% and 40% of insulation breakdown in EPDM and silicone-type insulators respectively. As degradation continued because of an indoor accelerated UV test, breakdown voltage with which UV rays can be detected in an early stage decreased as well. A silicone polymer insulator would be severer than EPDM polymer insulator in terms of surface degradation because of UV strength against $V_m/V_{BD}$ was high in silicone polymer insulators. UV strength in silicone-type insulators increased at 1,000 $kJ/m^2$ because contact angle at the intial stage sharply decreased to from $113^{\circ}$ to $92.1^{\circ}$.

PHYSICAL CHARACTERISTICS OF CORONAL REGION DRIVING OUT THE INTERPLANETARY SHOCK (행성간 충격파 발생 코로나 영역의 물리적 특성)

  • Oh, Su-Yeon;Yi, Yu
    • Journal of Astronomy and Space Sciences
    • /
    • v.25 no.1
    • /
    • pp.25-32
    • /
    • 2008
  • Using the solar wind data of 2000 observed by ACE, We classified the interplanetary shock on basis of shock driver. We examined the physical properties of shock drivers such as the ratio of charge states(O7/O6) and thermal index$(I_{th})$. Most of 51 interplanetary shocks are driven by interplanetary coronal mass ejections(ICME; magnetic cloud and ejecta) and high speed streams. According to the test of temperature(O7/O6) and $I_{th}$, we found that ICMEs originated from region with hot source in corona.

Development of Formulas for Predicting Radio Noise from Overhead HVAC Transmission Lines using Least Squares Optimization Method (최소자승법에 의한 초고압 가공 송전선로의 라디오 잡음장해 예측계산식 개발)

  • Yang, Gwang-Ho;Ju, Mun-No;Myeong, Seong-Ho;Sin, Gu-Yong;Lee, Dong-Il
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.1
    • /
    • pp.37-42
    • /
    • 2000
  • The radio noise produced by corona discharge in high voltage transmission lines is one of the most important line design considerations. Therefore it is necessary for transmission line designers to pre-evaluate radio noise using prediction formulas or field test results. In this paper, more accurate and useful formulas for predicting radio noise during fair and foul weathers in high voltage AC transmission lines were proposed through comparison with the existing formulas. Also it was verified by comparing with the long-term measured data from operating lines that the proposed formulas are more accurate. The proposed prediction formulas are developed by the applications of nonlinear least squares optimization method to radio noise database collected from lines throughout the world.

  • PDF

Development of Working Platform for the Polymer Insulator String (송전선로 폴리머애자 공사용 장비 개발)

  • Min, Byeong-Wook;Wi, Shwa-Bok;Bang, Hang-Kwon;Choi, Han-Yeol;Baek, Soo-Gon;Park, Jae-Ung
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.438-439
    • /
    • 2006
  • Porcelain insulators have generally been used in Korea to insulate a transmission line from the tower, and a highly polymerized compound polymer insulator which has superior stain proof characteristics, has also been used widely. Currently, a worker rides on the suspension insulator string for installation on towers and conductors but in case of polymer insulators, this will pollute and scratch the housing result in durability reduction by deterioration and corona. This study developed a high strength aluminum compound metal lauder designed to work on polymer insulators without riding, and a clamp type connecting device and safety gear for easy installation on the tower and conductor. These polymer insulator work device can be used for 154kV and 345kV polymer insulators through a strength and load test to secure safety. This paper presents field usage.

  • PDF

Development of the Camera System for Total Solar Eclipse

  • Kim, Jihun;Choi, Seonghwan;Park, Jongyeob;Bong, Su-Chan;Jang, Bi-Ho;Park, Sung-Joon;Yang, Heesu;Park, Young-Deuk;Cho, Kyungsuk
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.84.3-85
    • /
    • 2017
  • Korea Astronomy and Space Science Institute (KASI) has been developing the Camera System for the Total Solar Eclipse (TSE) observation. In 2016 we have assembled a simple camera system consisting of a commercial camera lens, a polarizer, bandpass filters, and a Canon camera to observe the solar corona during the Total Solar Eclipse in Indonesia. For 2017 TSE observation, we have studied and adapted the compact coronagraph design proposed by NASA. The compact coronagraph design dramatically reduces the volume and weight, and used for TSE observation. The camera is used to test and verify key components including function of bandpass filter, polarizer, and CCD during observing the Total Solar Eclipse. In this poster we focus on optical engineering works including designing, analyzing, testing, and building for the TSE observation.

  • PDF

Particle Agglomeration of a Bipolar Charging System with a Control Grid (제어전극을 갖는 쌍극성 하전장치의 입자응집 특성)

  • Moon, Jae-Duk;Ahn, Chang-Jin
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.10
    • /
    • pp.465-470
    • /
    • 2005
  • In this paper. an experimental study, for method of increasing the efficiency of electrostatic precipitator for the collection of submicron-sized particles has been studied. All AC electric field was used to induce agglomeration of bipolory charged Particles. .4 bipolar AC-agglomeration system. consisted with a multineedle-mesh discharge system with a control grid, was proposed and investigated. Systematic experiments were carried out to investigate the agglomeration ratio of the AC-agglomeration system as a function of the different grid spacings and grid resistances for the submicron particles generated from liquid prorhane gas burning. The agglomeration ratios, which indicate the particle numbers before and after agglomeration of the test particles in number concentration base, were found to be 0.87, 1.80, 3.86, 9.50 and, 11.00 times for the particle sizes of 0.3. 0.5, 0.7, 1.0, and 2.0$\mu$m at applied voltage of 3.5kV, respectively which showed that the fine particle numbers were decreased while the larger particle numbers were increase greatly.

Phenobarbital and zonisamide treatment of a cat with epilepsy of unknown cause

  • Lee, Ki-Ho;Park, Jun-Seok;Kim, Jung-Kook;Seo, Kyoung-Won;Song, Kun-Ho
    • Korean Journal of Veterinary Service
    • /
    • v.40 no.2
    • /
    • pp.143-147
    • /
    • 2017
  • A Korean domestic short hair (1-year-old, male) presented with 2 to 3 weeks of seizures, aggressive behavior, vomiting, anorexia, and lethargy. The frequency of seizure had gradually increased from once a week to once every 3 hours. Physical and neurologic examination, diagnostic screening tests, including complete blood count (CBC), serum chemistry, electrolyte, coagulation test, X-ray, ultrasonography, and urinalysis were performed. Feline Leukemia Virus (FeLV), Feline Immunodeficiency Virus (FIV) and Toxoplasma spp. All tested negative, but the Feline Corona Virus (FCoV) kit revealed a positive result. To determine the exact diagnosis, magnetic resonance imaging (MRI) was performed but yielded no specific findings. The patient was then diagnosed with idiopathic epilepsy and treatment of phenobarbital was initiated. A month's treatment with phenobarbital proved ineffective as symptoms worsened. Zonisamide was then selected as an additional anticonvulsant. After adding zonisamide, symptoms improved, and seizures abated for 15 months. This is the first case report in South Korea describing the use of phenobarbital and zonisamide in the treatment of a cat with idiopathic epilepsy.

Frequency Spectrum Analysis of Electromagnetic Waves Radiated by Electric Discharges

  • Park, Dae-Won;Kil, Gyung-Suk;Cheon, Sang-Gyu;Kim, Sun-Jae;Cha, Hyeon-Kyu
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.3
    • /
    • pp.389-395
    • /
    • 2012
  • In this paper, we analyzed the frequency spectrum of the electromagnetic waves radiated by an electric discharge as a basic study to develop an on-line diagnostic technique for power equipment installed inside closed-switchboards. In order to simulate local and series arc discharges caused by an electric field concentration and poor connections, three types of electrode systems were fabricated, consisting of needle and plane electrodes and an arc generator meeting the specifications of UL 1699. The experiment was carried out in an electromagnetic anechoic chamber, and the measurement system consisted of a PD free transformer, a loop antenna with a frequency bandwidth of 150 kHz-30 MHz, an ultra log periodic antenna with a frequency bandwidth of 30 MHz-2 GHz, and an EMI test receiver with a frequency bandwidth of 3 Hz-3 GHz. According to the experimental results, the frequency spectra of the electrical discharges were widely distributed across a range of 150 kHz-400 MHz, depending on the defects, while commonly found between 150 kHz and 10 MHz. Therefore, considering the ambient noise and antenna characteristics, the best frequency bandwidth for a measurement system to monitor abnormal conditions by detecting electromagnetic waves in closedswitchboards is 150 kHz-10 MHz.

The solution for preventing the expansion of cable joint caused by methane($CH_4$) gas to Water proof type of power cable (도체 수밀형 전력케이블의 가교잔사 가스에 의한 직선접속재 부풀음 현상 방지 대책)

  • Kim, Jong-Won;Lee, Ki-Soo;Paek, Heum-Soo;Choi, Bong-Nam;Park, Hee-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2020-2022
    • /
    • 2000
  • The cross-linked polyethylene(herein after XLPE) insulated power cable emit the methane($CH_4$)gas in the course of chemical cross-linking process. The general stranded conductor easily discharge this methane gas through the gap of each stranded wires. But the special stranded conductor that filled with semi-conducting rubber compound to prevent water penetration which is applied to water proof type of cable(22.9kV CN/CV-W), disturb the methane gas emission. The pre-mold type cable joint shall be expanded gradually by emit of gas left in XLPE insulation. For example, sometimes the corona problem outbreak on a new power distribution line, resulted from the gap between the sleeve and semi-conductive layer of cable joint. If above mentioned problem especially happened on the way of operating. We have to shut down the line and try to discharge the methane gas in cable joint. In this point, we would like to explain the mechanism of methane gas & cable joint and our test result briefly. At last, we are pleased to introduce the solution for preventing reoccurrence of this problem.

  • PDF

Predischarge Phenomena in Nonuniform Fields Caused by Lightning Impulse Voltages in SF(sub)6-$N_2$Mixtures (SF(sub)6-$N_2$혼합가스중에 뇌임펄스전압에 의해 형성된 불평등전장에서의 전구방전현상)

  • 이복희;이경옥;백승권
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.6
    • /
    • pp.288-295
    • /
    • 2001
  • Predischarges in nonuniform electric field stressed by lightning impulse voltagesin SF(sub)6-$N_2$mixtures are initiated by streamer coronas. Due to field ehnancement at a protrusion point of electrodes new ionization processes occur and a precursor, which leads to a first leader, is created. The leader proceeds step by step to the opposite electrode and the final jump bridges the test gap. It was found that the predischarge is propagated with a leader mechanism of stepwise expansion from the predischarge current waveforms measured by a shunt. The predischarge current is closely related to the amplitude and polarity of applied voltages, the gas pressure and the gap geometry. The time intervals between step leaders for the positive and negative polarities were inversely proportional to V.P$^2$. When the gas pressure increases in the positive polarity, statistical time lag to statistical time lag to streamer corona inception increase slightly, but the formative time lag to flashover is significantly decreased.

  • PDF