• 제목/요약/키워드: Core voltages

검색결과 51건 처리시간 0.023초

Design of a 1 MVA HTS Transformer with Double Pancake Windings

  • Kim, Woo-Seok;Park, Kyeong-Dal;Joo, Hyeong-Gil;Han, Jin-Ho;Hong, Gye-Won;Park, Jungho;Heesuck Song;Kim, Sung-Hoon;Hahn, Song-yop
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권1호
    • /
    • pp.48-51
    • /
    • 2003
  • A 1 MVA transformer with BSCCO-2223 high Tc superconducting (HTS) tapes was designed. The rated voltages of each sides of the transformer are 22.0 kV and 6.6 kV respectively. Double pancake HTS windings, which have advantages of insulations and distribution of high voltage, were adopted. Four HTS tapes were wound in parallel fer the windings of low voltage side. Each winding was composed of several double pancake windings made of four parallel conductors were transposed in order to distribute the currents equally in each conductor. A core of the transformer was designed as a shell type core made of laminated silicon steel plate and the core is separated with the windings by a cryostat with a room temperature bore. The operating temperature of HTS windings will be 65K with liquid nitrogen, and a cooling system using a cryocooler was proposed and designed conceptually. This HTS transformer is going to be manufactured in near future based on the design parameters presented in this paper.

1MVA 고온 초전도 변압기 개념 설계 및 3차원 전자장 해석 (Conceptual Design and 3-D Electromagnetic Analysis of 1MVA HTS Transformer)

  • 박찬배;김우석;최경달;주형길;홍계원;한송엽
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권1호
    • /
    • pp.23-26
    • /
    • 2003
  • This paper presents conceptual design and 3-D electromagnetic analysis of IMVA transformer with BSCCO-2223 High Tc Superconducting (HTS) tapes. The rated voltages of each sides of the transformer are 22.9 kV and 6.6 kV, and double pancake windings were adopted. High voltage and Low voltage sides were composed of several double pancake windings. Four HTS tapes were wound in parallel for the windings of low voltage side and were transposed in order to distribute the currents equally in each conductor The transformer core was designed as a shell type core made of laminated silicon steel plates and the core is separated with the windings by a cryostat with Fiberglass Reinforced Plastics(FRP). A sub-cooling system using L$N_2$ were designed to maintain the coolant temperature 65K. Finally perpendicular components of magnetic field applied to tapes were calculated 0.247 in the rated operation using 3-D analysis. A real 1MVA HTS transformer will be manufactured in near future based on the design parameters presented in this paper.

자기회로의 위상학적 상사성을 이용한 전류제한기 구조에 관한 연구 (The Research for a Structure of Current Limiter using a Phasic Similitude of Magnetic Circuit)

  • 지근양;민경일;이수원;장봉환;문영현
    • 전기학회논문지
    • /
    • 제58권11호
    • /
    • pp.2128-2135
    • /
    • 2009
  • In this paper, current limiter using a magnetic switching which is based on magnetic flux change in the case of fault is proposed. This current limiter consists of iron-core and three parts of coils. One is the primary coil connected to the power system. Another is the secondary coil wound to the opposite direction of the primary coil's winding. The other is the secondary of the secondary coil which is a movable copper plate winding and located below the secondary coil. In the normal state, the magnetic flux produced in the primary and secondary coils flows to the opposite directions each other and becomes to be canceled out. Therefore the voltages induced between the coils are zero. In the case of a fault, at the moment of a fault occurrence recognition, the switch connected to a secondary coil is opened and the secondary of the secondary coil is pulled out to the outside of the iron-core. Then, magnetic flux becomes to flow through the iron-core. Accordingly, the voltage is induced between the both ends of the primary coil and makes the current reduced. Therefore it is possible to cut off the circuit breaker easily with the proposed current limiter. This paper analyzes the current limiting effects and the detailed results are given.

Stator Insulation Quality Assessment for High Voltage Motors Based on Probability Distributions

  • Kim, Hee-Dong;Kim, Chung-Hyo
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권4호
    • /
    • pp.571-575
    • /
    • 2008
  • Stator insulation quality assessment for high voltage motors is a major issue for the reliable maintenance of industrial and power plants. To assess the condition of stator insulation, nondestructive tests were performed on the sixty coil groups of twelve motors. After completing the nondestructive tests, the AC voltage applied to the stator winding was gradually increased until insulation failure in order to obtain the breakdown voltage. The stator winding of each motor was classified into five coil groups; one group with healthy insulation and four groups with four different types of artificial defects. To analyze the breakdown voltage statistically, Weibull distribution was employed for the tests on the fifty coil groups of ten motors. The 50th percentile values of the measured breakdown voltages based on the statistical data of the five coil groups of ten motors were 26.1kV, 25.0kV, 24.4kV, 26.7kV and 30.5kV, respectively. Almost all of the failures were located in the line-end coil at the exit of the core slot. The breakdown voltages and the types of defects showed strong relation to the stator insulation tests such as in the case of dissipation factor and ac current. It is shown that the condition of the motor insulation can be determined from the relationship between the probability of failure and the type of defect.

Step-Up Asymmetrical Nine Phase Delta-Connected Transformer for HVDC Transmission

  • Ammar, Arafet Ben;Ammar, Faouzi Ben
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1920-1929
    • /
    • 2018
  • In order to provide a source for nine phases suitable for 18-pulse ac to dc power, this paper proposes a new structure for a step-up asymmetrical delta-connected transformer for converting three-phase ac power to nine-phase ac power. The design allows for symmetry between the nine output voltages to improve the power quality of the supply current and to minimize the THD. The results show that this new structure proves the equality between the output voltages with $40^{\circ}-{\alpha}$ and $40^{\circ}+{\alpha}$ phase shifting and produces symmetrical output currents. This result in the elimination of harmonics in the network current and provides a simulated THD that is equal to 5.12 %. An experimental prototype of the step-up asymmetrical delta-autotransformer is developed in the laboratory and the obtained results give a network current with a THD that is equal to 5.35%. Furthermore, a finite element analysis with a 3D magnetic field model is made based on the dimensions of the 4kVA, 400 V laboratory prototype three-phase with three-limb delta-autotransformer with a six-stacked-core in each limb. The magnetic distribution flux, field intensity and magnetic energy are carried out under open-circuit operation or load-loss.

ESS 연계용 변압기의 결선방식 및 철심구조에 따른 순환전류와 포화특성에 관한 연구 (Characteristics of Saturation and Circulating Current Based on Winding and Iron Core Structure of Grid-connected Transformer in Energy Storage System)

  • 태동현;이후동;김지명;노대석
    • 한국산학기술학회논문지
    • /
    • 제21권4호
    • /
    • pp.39-48
    • /
    • 2020
  • 2017년 8월에 발생한 고창 전력시험센터를 시작으로, 현재까지 총 29건의 전기저장장치 화재가 발생하여 많은 재산피해가 보고되고 있다. 이에 대한 원인은 아직 정확하게 규명되지 않았으나, ESS(energy storage system)와 전력변환장치뿐만 아니라, 계통측 불평형 문제도 하나의 원인으로 고려되어야 할 것으로 보인다. 특히, 연계용변압기측의 순환전류가 자화전류에 영향을 미쳐, 의도치 않게 변압기의 철심이 포화되고 서지전압이 발생하여 ESS에 영향을 줄 수 있다. 따라서, 본 논문에서는 부하불평형에 의한 불평형전류 발생시, ESS 연계용변압기로 순환전류의 유입과 변압기 포화로 인한 서지전압 발생 현상을 해석하기 위하여, PSCAD/EMTDC를 이용한 배전용변전소, 연계용변압기 및 수용가부하로 구성된 배전계통의 모델링을 수행한다. 또한, 이러한 문제를 해결하기 위하여, 중성점 접지 저항기(neutral grounding resistor, NGR)를 통해 순환전류의 크기를 일정 값 이내로 저감시키는 방안을 제시하였다. 이를 바탕으로 시뮬레이션을 수행한 결과, 연계용변압기의 결선방식 및 철심구조에 따라 일정 값(10[A]) 이상의 순환전류가 발생하여, ESS에 전기적인 위해 요인이 될 수 있음을 알 수 있었고, 변압기 포화로 인해 2차측에 최대 3[pu]의 서지전압이 발생될 수 있음을 확인하였다.

자속구속형 초전도 전류제한기의 철심조건에 따른 특성 (Characteristics of the Flux-lock Type Superconducting Fault Current Limiter According to the Iron Core Conditions)

  • 남긍현;이나영;최효상;조금배
    • 조명전기설비학회논문지
    • /
    • 제20권7호
    • /
    • pp.38-45
    • /
    • 2006
  • 초전도전류제한기(SFCL)는 전력계통내 적용시 계통보호를 보다 향상시킬 수 있는 방안으로써 수초이내에 신속하게 사고전류를 제한한다. 이러한 SFCL중 자속구속형 전류제한기의 설계구조는 자속구속리액터인 하나의 철심에 1차측과 2차측 코일이 병렬로 결선되어 있다. 또한 전류제한소자인 YBCO박막과 2차측 코일을 직렬로 결선하여 설치장소의 조건에 따라 인덕턴스와 2차측 코일의 극성방향으로 과도전류 크기를 조절할 수 있다. 이러한 동작특성은 철심을 자속매개체로 적용되기 때문에 철심조건에 따른 성능평가실험은 필수적이다. 가극결선에서 전원전압을 200[Vrms] 인가시 피크전류는 폐루프가 30.71[A], 개루프가 32.01[A]까지 상승됨에 따라 초기과도 응답특성은 폐루프가 유리하였다. 하지만, 소자에 발생되는 전압이 폐루프가 220.14[V], 개루프가 142.73[V]까지 상승함에 따라, 폐루프 철심구조시 전류제한소자의 부담이 가중됨을 알 수 있었다. 결과적으로 자속구속형 SFCL의 전력계통내 적용 시 각각의 철심구조에 따른 다양한 운전특성을 적절히 설계시 장점을 극대화 할 수 있을 것이다.

Design and Fabrication of 1 MVA Single Phase HTS Transformer for Power Distribution with Natural Convection Cooling System

  • Kim, W. S.;Kim, S. H.;Park, K. D.;H. G. Joo;G. W. Hong;J. H. Han;Park, J. H.;H. S. Son;S. Y. Hahn
    • Progress in Superconductivity
    • /
    • 제5권2호
    • /
    • pp.149-152
    • /
    • 2004
  • The design and the fabrication of a 1 MVA single-phase HTS transformer are presented in this paper, The rated voltages are 22.9 ㎸ for primary and 6.6 ㎸ for secondary, and the rated currents are 44 A and 152 A respectively. The transformer has HTS double pancake type windings. This type of winding has many advantages such as ease of fabrication and maintenance, good distribution of surge voltage and insulation of windings. Single HTS wire was used for primary winding and four HTS parallel wires were used for secondary winding. These windings are arranged reciprocally with the shell type iron core. An FRP cryostat with room temperature bore was fabricated to isolate the iron core from the coolant. The winding will be cooled down to 65 K with sub-cooled liquid nitrogen using a GM-cryocooler. The sub-cooled liquid nitrogen has advantages of good insulation because of no bubbles as well as increased current capacity of HTS wire.

  • PDF

Intrinsic Cylindrical/Surrounding Gate SOI MOSFET의 I-V 특성 도출을 위한 해석적 모델 (Analytical Model for Deriving the I-V Characteristics of an Intrinsic Cylindrical Surrounding Gate MOSFET)

  • 우상수;이재빈;서정하
    • 대한전자공학회논문지SD
    • /
    • 제48권10호
    • /
    • pp.54-61
    • /
    • 2011
  • 본 논문에서는 intrinsic-body cylindrical/surrounding gate SOI MOSFET의 I-V 특성 도출을 위한 간단한 해석적 모델을 제시하였다. Intrinsic 실리콘 채널 영역에서의 Poisson 방정식과 gate oxide 내에서의 Laplace 방정식을 해석적으로 풀어 소스와 드레인 양단 끝에서의 표면 전위 분포를 bisection method를 이용하여 구하였다. 구해진 표면 전위를 바탕으로 closed-form의 I-V 특성 식을 도출하였다. 도출된 I-V 특성 표현 식을 모의 실험한 결과, 소자의 parameter와 가해진 bias 전압에 대한 비교적 정확한 의존성을 확인할 수 있었다.

Fabrication and Characteristic Tests of a 1 MVA Single Phase HTS Transformer with Concentrically Arranged Windings

  • Kim, S.H.;Kim, W.S.;Choi, K.D.;Joo, H.G.;Hong, G.W.;Han, J.H.;Lee, H.G.;Park, J.H.;Song, H.S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권4호
    • /
    • pp.37-40
    • /
    • 2004
  • A 1 MV A single phase high temperature superconducting (HTS) transformer was manufactured and tested. The rated voltages of primary and secondary of the HTS transformer are 22.9 kV and 6.6 kV respectively. BSCCO-2223 HTS tape was used for HTS windings of 1 MV A HTS transformer. In order to reduce AC loss generated in the HTS winding, the type of concentric arrangement winding was adopted to a 1 MV A HTS transformer. Single HTS tape for primary windings and 4 parallel HTS tapes for secondary windings were used considering the each rated current of the HTS transformer. A core of HTS transformer was fabricated as a shell type core made of laminated silicon steel plate. And a GFRP cryostat with a room temperature bore was also manufactured. The characteristic tests of 1 MV A HTS transformer were performed such as no load test, short circuit test and several insulation tests at 65 K using sub-cooled liquid nitrogen. From the results of tests, the validity of design of HTS transformer was ascertained.