• Title/Summary/Keyword: Core needle

Search Result 77, Processing Time 0.027 seconds

Video-Assisted Thoracic Surgery Core Needle Biopsy for Pulmonary Nodules in Patients with Impaired Lung Function: Is It Feasible and Safe?

  • Yong-Seong Lee;Jong Duk Kim;Hyun-Oh Park;Chung-Eun Lee;In-Seok Jang;Jun-Young Choi
    • Journal of Chest Surgery
    • /
    • v.56 no.1
    • /
    • pp.1-5
    • /
    • 2023
  • Background: The number of patients with incidentally identified pulmonary nodules is increasing. This study attempted to confirm the usefulness and safety of video-assisted thoracic surgery (VATS) core needle biopsy of pulmonary nodules. Methods: Data from 18 patients diagnosed with pulmonary nodules who underwent VATS core need biopsy were retrospectively reviewed. Results: Of the 18 patients, 15 had malignancies (primary lung cancer, n=14; metastatic lung cancer, n=1), and 3 had benign nodules. Mortality and pleural metastasis did not occur during the follow-up period. Conclusion: In patients with solitary pulmonary nodules that require tissue confirmation, computed tomography-guided percutaneous cutting needle biopsy or diagnostic pulmonary resection sometimes may not be feasible choices due to the location of the solitary pulmonary nodule or the patient's impaired pulmonary function, VATS core needle biopsy may be performed in these patients as an alternative method.

The Role of Ultrasound Guided Core Needle Biopsy in Thyroid Nodule (갑상선 결절에서 초음파 유도하 중심생검의 역할)

  • Ryu, Yoon-Jong;Ahn, Soon-Hyun
    • Korean Journal of Head & Neck Oncology
    • /
    • v.31 no.1
    • /
    • pp.1-4
    • /
    • 2015
  • Fine needle aspiration cytology(FNAC) holds a main role in assessing thyroid nodules. But nonnegligible rate of thyroid cytology is reported as uncertain, indeterminate or inadequate for diagnosis. Recently, the microhistologic evaluation by core needle biopsy(CNB) under ultrasound sonographical guidance has been reported to show high accuracy for the diagnose of thyroid nodules. Aim of this review was to furnish the state of the art of this topic by summarizing previous published data about indication, diagnostic performance, and complication of CNB in thyroid lesions compared with FNAC

  • PDF

The Usefulness of Fine Needle Aspiration Cytology of Bone Lesions (골 병변에서 세침흡인 세포검사의 유용성)

  • Kim, Bohng-Hee;Gong, Gyung-Yub
    • The Korean Journal of Cytopathology
    • /
    • v.13 no.2
    • /
    • pp.51-59
    • /
    • 2002
  • To determine the usefulness on fine needle aspiration cytology(FNAC) of bone lesions and the complementary role of FNAC and percutaneous needle biopsy, 75 cases of FNAC taken from bone lesions were analyzed. Correlations with histopathology were possible in 47 cases, including 14 cases of simultaneous core biopsy and 33 cases of subsequent open biopsy due to inadequate aspirates. Among 75 cases, 4 cases were benign tumors and tumor-like lesion, 11 cases were malignant primary bone tumors, 17 cases were metastatic tumors, and 43 cases were nonneoplastic bone lesions. The aspirates were adequate in 35 cases(46.7%), in all of which the discrimination between benignancy and malignancy was possible. The main reason for Inadequate aspirates was due to hypocellularity. In the cases of aspiration and core biopsy simultaneously done, the diagnostic accuracy of aspiration, core biopsy, and both were 57%(8/14), 78.6%(11/14), and 92.9%(13/14), respectively. We conclude that a final diagnosis based on cytology is possible with the adequate aspirates and the clinical and radiological findings. Also we confirm the complementary role between FNAC and core biopsy in bone lesions.

A Case of Intra-thyroidal Schwannoma Diagnosed by Preoperative Core Needle Biopsy (수술 전 중심부바늘생검을 통해 진단된 갑상선에 발생한 신경초종 1예)

  • Dong Gyu Choi;Young-Ok Kim;Min Jung Jung;Hyoung Shin Lee
    • Korean Journal of Head & Neck Oncology
    • /
    • v.39 no.1
    • /
    • pp.37-40
    • /
    • 2023
  • Schwannoma is a slow growing benign tumor that can occur anywhere in our body. About 25~45% cases of schwannomas occur in the head and neck, but intra-thyroidal schwannomas are very rare, and mostly are diagnosed by post-thyroidectomy pathologic study. In this article, we present a case of intra-thyroidal schwannoma diagnosed preoperatively with core needle biopsy. The patient underwent enucleation of the thyroid tumor, and the pathology of the tumor was confirmed as schwannoma. Few cases of intra-thyroidal schwannomas have been reported in the literature, but none of them have been diagnosed through core needle biopsy preoperatively. Preoperative diagnosis of intra-thyroidal schwannoma can be helpful when determining appropriate surgical extent and avoid unnecessary thyroidectomy.

Usefulness of X-ray Guided Biopsy and Ultrasound Guided Biopsy in Breast Microcalcification Biopsy (유방 미세석회화 조직검사에서 X선 유도 하 조직검사와 초음파 유도 하 조직검사의 유용성)

  • Choi, Miseon;Song, Jongnam
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.201-206
    • /
    • 2016
  • Social interest in breast cancer has increased. The most basic exams for diagnosis include breast X-ray and breast ultrasound. In particular, breast microcalcification requires histological diagnosis, and breast microcalcification biopsy is commonly performed. Therefore, this study aimed to analyze and assess X-ray guided biopsy (needle localized open biopsy) and ultrasound guided biopsy (sono guided core needle biopsy), which are basics in diagnosis of microcalcification. Targeting 241 cases in which magnification mammography was performed for patients who visited the hospital due to breast microcalcification, age distribution and the location of lesions were analyzed in X-ray guided biopsy and ultrasound guided biopsy. By classifying exams performed after magnification mammography, the frequencies of X-ray guided biopsy and ultrasound guided biopsy were analyzed, and malignant and benign results were confirmed. The results showed that 64 cases(26.6%) were X-ray guided biopsy, which was 5.4 times higher than 12 cases(4.9%) of ultrasound guided biopsy. Due to development of ultrasound equipments, stereotactic vacuum-assisted biopsy, etc. the methods of histological diagnosis of microcalcification have become diverse, but when considering characteristics and limitations of each exam, X-ray guided biopsy is thought to be most accurate and useful.

Diagnostic Accuracy of Fine Needle Aspiration Cytology versus Concurrent Core Needle Biopsy in Evaluation of Intrathoracic Lesions: a Retrospective Comparative Study

  • Eftekhar-Javadi, Arezoo;Kumar, Perikala Vijayananda;Mirzaie, Ali Zare;Radfar, Amir;Filip, Irina;Niyazi, Maximilian;Sadeghipour, Alireza
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.16
    • /
    • pp.7385-7390
    • /
    • 2015
  • Background: Transthoracic fine needle aspiration (FNA) cytology and core needle biopsy (CNB) are two commonly used approaches for the diagnosis of suspected neoplastic intrathoracic lesions. This study compared the diagnostic accuracy of FNA cytology and concurrent CNB in the evaluation of intrathoracic lesions. Materials and Methods: We studied FNA cytology and concurrent CNB specimens of 127 patients retrospectively, using hematoxylin and eosin (H&E), immunohistochemistry, and, on certain occasions cytochemistry. Information regarding additional tissue tests was derived from the electronic archives of the Department of Pathology and Laboratory Medicine as well as patient records. Diagnostic accuracy was calculated for each test. Results: Of 127 cases, 22 were inconclusive and excluded from the study. The remaining 105 were categorized into 73 (69.5%) malignant lesions and 32 (30.5%) benign lesions. FNA and CNB findings were in complete agreement in 63 cases (60%). The accuracy and confidence intervals (CIs) of FNA and CNB for malignant tumors were 86.3% (CI: 79.3-90.7) and 93.2% (CI: 87.3-96.0) respectively. For epithelial malignant neoplasms, a definitive diagnosis was made in 44.8% of cases by FNA and 80.6% by CNB. The diagnostic accuracy of CNB for nonepithelial malignant neoplasms was 83.3% compared with 50% for FNA. Of the 32 benign cases, we made specific diagnoses in 16 with diagnostic accuracy of 81.3% and 6.3% for CNB and FNA, respectively. Conclusions: Our findings suggest that FNA is comparable to CNB in the diagnosis of malignant epithelial lesions whereas diagnostic accuracy of CNB for nonepithlial malignant neoplasms is superior to that for FNA. Further, for histological typing of tumors and examining tumor origin, immunohistochemical work up plays an important role.

Comparison of Pre-Operation Diagnosis of Thyroid Cancer with Fine Needle Aspiration and Core-needle Biopsy: a Meta-analysis

  • Li, Lei;Chen, Bao-Ding;Zhu, Hai-Feng;Wu, Shu;Wei, Da;Zhang, Jian-Quan;Yu, Li
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.17
    • /
    • pp.7187-7193
    • /
    • 2014
  • Background: The aim of this meta-analysis was to compare sensitivities and specificities of fine needle aspiration (FNA) and core needle biopsy (CNB) in the diagnosis of thyroid cancer. Materials and Methods: Articles were screened in Medline, the Cochrane Library, EMBASE and Google Scholar, and subsequently included and excluded based on the patient/problem-intervention-comparison-outcome (PICO) principle. Primary outcome was defined in terms of diagnostic values (sensitivity and specificity) of FNA and CNB for thyroid cancer. Secondary outcome was defined as the accuracy of diagnosis. Compiled FNA and CNB results from the final studies selected as appropriate for meta-analysis were compared with cases for which final pathology diagnoses were available. Statistical analyses were performed for FNA and CNB for all of the selected studies together, and for individual studies using the leave-one-out approach. Results: Article selection and screening yielded five studies for meta-analysis, two of which were prospective and the other three retrospective, for a total of 1,264 patients. Pooled diagnostic sensitivities of FNA and CNB methods were 0.68 and 0.83, respectively, with specificities of 0.93 and 0.94. The areas under the summary ROC curves were 0.905 (${\pm}0.030$) for FNA and 0.745 (${\pm}0.095$) for CNB, with no significant difference between the two. No one study had greater influence than any other on the pooled estimates for diagnostic sensitivity and specificity. Conclusions: FNA and CNB do not differ significantly in sensitivity and specificity for diagnosis of thyroid cancer.

The Role of Core Needle Biopsy for the Evaluation of Thyroid Nodules with Suspicious Ultrasound Features

  • Sae Rom Chung;Jung Hwan Baek;Young Jun Choi;Tae-Yon Sung;Dong Eun Song;Tae Yong Kim;Jeong Hyun Lee
    • Korean Journal of Radiology
    • /
    • v.20 no.1
    • /
    • pp.158-165
    • /
    • 2019
  • Objective: Recent studies demonstrated that core needle biopsy (CNB) can effectively reduce the possibility of inconclusive results and prevent unnecessary diagnostic surgery. However, the effectiveness of CNB in patients with suspicious thyroid nodules has not been fully evaluated. This prospective study aimed to determine the potential of CNB to assess thyroid nodules with suspicious ultrasound (US) features. Materials and Methods: Patients undergoing CNB for thyroid nodules with suspicious features on US were enrolled between May and August 2016. Diagnostic performance and the incidence of non-diagnostic results, inconclusive results, conclusive results, malignancy, unnecessary surgery, and complications were analyzed. Subgroup analysis according to nodule size was performed. The risk factors associated with inconclusive results were evaluated using multivariate logistic regression analysis. Results: A total of 93 patients (102 thyroid nodules) were evaluated. All samples obtained from CNB were adequate for diagnosis. Inconclusive results were seen in 12.7% of cases. The diagnostic accuracy, sensitivity, specificity, positive predictive value, and negative predictive value for diagnosis of malignancy were 93.8%, 100%, 100%, 78.9%, and 95%, respectively. None of the patients underwent unnecessary surgery. The diagnostic performance was not significantly different according to nodule size. On multivariate logistic regression analysis, larger nodule size and shorter needle length were independent risk factors associated with inconclusive results. Conclusion: Samples obtained by CNB were sufficient for diagnosis in all cases and resulted in high diagnostic values and conclusive results in the evaluation of suspicious thyroid nodules. These findings indicated that CNB is a promising diagnostic tool for suspicious thyroid nodules.

Comparison of diagnostic performances of slow-pull suction and standard suction in endoscopic ultrasound-guided fine needle biopsy for gastrointestinal subepithelial tumors

  • Joon Seop Lee;Chang Min Cho;Yong Hwan Kwon;An Na Seo;Han Ik Bae;Man-Hoon Han
    • Clinical Endoscopy
    • /
    • v.55 no.5
    • /
    • pp.637-644
    • /
    • 2022
  • Background/Aims: Endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) is integral to the diagnosis of gastrointestinal (GI) subepithelial tumors (SETs). The impact of different EUS-FNB tissue sampling techniques on specimen adequacy and diagnostic accuracy in SETs has not been fully evaluated. This study aimed to compare the diagnostic outcomes of slow-pull (SP) and standard suction (SS) in patients with GI SETs. Methods: In this retrospective comparative study, 54 patients were enrolled. Medical records were reviewed for location and size of the target lesion, FNB needle type/size, technical order, specimen adequacy, diagnostic yield, and adverse events. The acquisition rate of adequate specimens and diagnostic accuracy were compared according to EUS-FNB techniques. Results: The mean lesion size was 42.6±36.4 mm, and most patients were diagnosed with GI stromal tumor (75.9%). The overall diagnostic accuracies of the SP and SS techniques were 83.3% and 81.5%, respectively (p=0.800). The rates of obtaining adequate core tissue were 79.6% and 75.9%, respectively (p=0.799). No significant clinical factors affected the rate of obtaining adequate core tissue, including lesion location and size, FNB needle size, and final diagnosis. Conclusions: SP and SS had comparable diagnostic accuracies and adequate core tissue acquisition for GI SETs via EUS-FNB.

Beam-scanning Imaging Needle for Endoscopic Optical Coherence Tomography

  • Yang, Woohyeok;Hwang, Junyoung;Moon, Sucbei
    • Current Optics and Photonics
    • /
    • v.5 no.5
    • /
    • pp.532-537
    • /
    • 2021
  • We present a compact endoscopic probe in a needle form which has a fast beam-scanning capability for optical coherence tomography (OCT). In our study, a beam-scanning OCT imaging needle was fabricated with a 26G syringe needle (0.46 mm in outer diameter) and a thin OCT imaging probe based on the stepwise transitional core (STC) fiber. The imaging probe could freely rotate inside the needle for beam scans. Hence, OCT imaging could be performed without rotation or translation of the needle body. In our design, the structural integrity of the needle's steel tubing was preserved for mechanical robustness. Probing the optical signal was performed through the needle's own window formed at the end. For hand-held operation of our imaging needle, a light and compact scanner module (130 g and 45 × 53 × 60 mm3) was devised. Connected to the imaging needle, it could provide rotational actuation driven by a galvanometer. Because of its finite actuation range, our scanner module did not need a fiber rotary joint which might add undesirable complexity. The beam scan speed was 20 Hz and supported 20 frames per second at the maximum for endoscopic OCT imaging.