• 제목/요약/키워드: Converter control

검색결과 3,152건 처리시간 0.038초

3-레벨 컨버터에 의한 직류전력제어 (DC Power Control for 3-Level Converter.)

  • 정연택;이사영;함년근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1996년도 창립기념 전력전자학술발표회 논문집
    • /
    • pp.126-129
    • /
    • 1996
  • This paper study on the control method of 3-level converter. The control of converter is composed of active power control for controlling a output voltage and of reactive power control for high power factor drives. And also, output central voltage is controlled by sensing a each condensor voltage of bank connected the part of dc.

  • PDF

Simultaneous Control of DC-DC Converters by DSP Controller

  • Park Hyo-Sik;Kim Hee-Jun
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.203-207
    • /
    • 2001
  • This paper presents a multi output converter system that controls, simultaneously and independently, the separate Buck converter and Boost converter with the different specification by one DSP digital controller. As two separate converters are regulated by only one DSP, it is possible to achieve the simple digital control circuit for regulating the multi output DC-DC converter. By setting the software switch state, PI or Fuzzy controller can be applied as a controller for each converter without any change of hardware. Also, PI and Fuzzy control characteristics of each DC-DC converter is validated by experimental results.

  • PDF

Design and Implementation of a Reverse Matrix Converter for Permanent Magnet Synchronous Motor Drives

  • Lee, Eunsil;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권6호
    • /
    • pp.2297-2306
    • /
    • 2015
  • This paper presents the development of a system with a reverse matrix converter (RMC) for permanent magnet synchronous motor (PMSM) drive and its effective control method. The voltage transfer ratio of the general matrix converter is restricted to a maximum value of 0.866, which is not suitable for applications whose source voltages are lower than the load voltages. The proposed RMC topology can step up the voltage without any additional components in the conventional circuit. Its control method is different from traditional matrix converter’s one, thus this paper proposes control schemes of RMC by means of controlling both the generator and motor side currents with properly designed control loop. The converter can have sinusoidal input/output current waveforms in steady state condition as well as a boosted voltage. In this paper, a hardware system with an RMC for a PMSM drive system is described. The performance of the system was investigated through experiments

첨두전류모드 제어기로 구동되는 병렬 승압컨버터의 전류분배 제어기 (Current Balance Controller for Parallel Boost Converter with Peak Current Mode Control)

  • 박종규;장은승;강신출;신용환;신휘범
    • 전기학회논문지
    • /
    • 제58권2호
    • /
    • pp.301-307
    • /
    • 2009
  • In the paralleled converter module with peak current mode control, current imbalance appears when the voltage controllers with integral control of converter module are not exactly identical. In this paper, the voltage controller is designed to equal the current command of each converter module using the current command bus. The current balance controller is also proposed to balance the average currents of converter modules with imbalaced inductance. It is designed to have good transient response. Proposed method is implemented with the paralleled 2-module and 4-module boost converters with imbalanced inductance. Experimental results verify the performance of current share during both steady and transient states of converter.

IPM 스위칭 소자를 적용한 AC 전동차 추진제어장치 (Converter/Inverter) 개발 (Development of AC Electric Vehicle Propulsion System (Converter/Inverter) using IPM Switching Device)

  • 노애숙;김태윤
    • 전력전자학회논문지
    • /
    • 제10권3호
    • /
    • pp.233-240
    • /
    • 2005
  • 본 논문은 현재까지 전적으로 수입에 의존하던 국내 교류 전동차용 추진제어장치(Converter/Inverter)를 대용량 IPM 스위칭 소자를 적용하여 개발된 시스템을 제안한다. 컨버터의 용량을 향상시키기 위해 2대의 PWM 컨버터를 병렬 운전하고 병렬 운전 시 각각의 컨버터 스위칭 각을 다르게 제어하여 고조파 함유를 줄였으며 DC-Link 단의 Beatless 제어를 수행하였다. VVVF 인버터 제어의 경우, 저속의 운전영역에서는 순시 토크 제어가 가능한 백터제어를 적용하고, 고속 운전 영역에서는 슬립 주파수제어를 적용하는 백터 제어와 스칼라 제어의 병용 제어기법을 제시하였다. 제시된 추진제어장치는 4대의 210kW 유도전동기를 이용하여 철도차량용 추진제어장치에 적용되는 관련 규격의 각종 시험을 통해 그 성능을 검증하였다.

소프트 스위칭형 PFC 승강압 AC-DC 컨버터에 관한 연구 (A Study on PFC Buck-Boost AC-DC Converter by Soft Switching Method)

  • 곽동걸;이승호;이봉섭;정도영;심재선;임진근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.435-437
    • /
    • 2007
  • Authors propose a PFC(power factor correction) Buck-Boost AC-DC converter by soft switching method. The proposed converter for a discontinuous conduction mode eliminates the complicated control requirement and reduces the size of components. The input current waveform in the converter is got to be a sinusoidal form of discontinuous pulse in proportion to magnitude of ac input voltage under the constant duty cycle switching.Therefore,the input power factor is nearly unity and the control algorithm is simple. To achieve high efficiency system, the proposed converter is constructed by using a partial resonant technique. The control switches using in the converter are operated with soft switching for a partial resonant. The control switches are operated without increasing their voltage and current stresses by the soft switching method. The result is that the switching loss is very low and the efficiency of converter is high.

  • PDF

원자로 제어봉제어시스템 전력변환부에 대한 새로운 고장 검출 방법 (A New Method of Fault Detection for Power Converter Unit in Control Rod Control System)

  • 천종민;김춘경;김석주;권순만;신종렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.556-558
    • /
    • 2004
  • In this paper, we introduce a new method of detecting faults for a power converter unit in Control Rod Control System. The faults of a power converter unit can exert harmful influence upon the operation of Control Rod Drive Mechanisms and the control of the reactor output. This situation makes the quick and correct detection of failures in a power converter unit very important. We devise a new method of fault detection for the digital power controller and improve the drawbacks of the existing fault detector.

  • PDF

임베디드 리눅스를 이용한 웹 기반 빌딩자동화시스템 (Web-based Building Automation System using Embedded Linux)

  • 신은철;이수영;최병욱
    • 제어로봇시스템학회논문지
    • /
    • 제10권4호
    • /
    • pp.334-340
    • /
    • 2004
  • In this paper, a Web-based management system for the building network is described. A multi-protocol converter based on SoC and embedded Linux is designed. The open source licensing, reliability, and broad hardware support are key reasons for use of embedded Linux in embedded industry. The multi-protocol converter integrates control network of RS-485 and LonWorks devices through TCP/IP protocol for a client with Java applet. The system consists of three-tier architecture, such as a client, a server that is performed on a multi-protocol converter, and control devices. The developed system includes the inverter motor control system with modbus protocol for the RS-485 network. The experiment results show that the multi-protocol converter using embedded Linux is a flexible and effective way to builda Web -based monitoring and control system.

A Novel Control Technique for a Multi-Output Switched-Resonant Converter

  • Sundararaman, K.;Gopalakrishnan, M.
    • Journal of Power Electronics
    • /
    • 제13권6호
    • /
    • pp.928-938
    • /
    • 2013
  • This paper proposes a novel control method for a multi-output switched-resonant converter. Output voltage can be regulated against variations in the supply voltage and load by controlling the voltage of the resonant capacitor (pulse amplitude control). Precise control is possible when pulse amplitude control is combined with pulse number control. The converter is analyzed, and design considerations are explained by using examples. Control implementation is described and load regulation and ripples are analyzed by simulation and hardware results. The topology is modified to obtain an additional negative output without any additional hardware other than a diode. The analysis of such a triple output converter with two positive outputs and one negative output is conducted and confirmed. The topology and control scheme are scalable to any number of outputs.

Dual Converter 정류회로의 입력 역율 제어 (Input Power Factor Control of Dual Converter Rectifier)

  • 이규종;성세진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.385-387
    • /
    • 1988
  • Dual converter is being used as a four-quadrant source for the controlled rectifier. But the rectifier itself and circulating current between P and N-converter contribute to generate reactive power. The methodology of input power factor control of dual converter by means of circulating current control is presented in this paper.

  • PDF