• Title/Summary/Keyword: Converter circuits

Search Result 471, Processing Time 0.031 seconds

A Ku-band LNA for LNB module (LNB 수신단의 LNA 설계에 관한 연구)

  • Kwak Yong-Soo;Kim Hyeong-Seok
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.369-372
    • /
    • 2004
  • In this paper, a low noise amplifier (LNA) in receiver of Low Noise Block Down Converter (LNB) for direct broadcasting service (DBS) is implemented by using GaAs HEMT The LNA is designed for operation between 10.7GHz-12.7GHz. The LNA consists of input, output matching circuits, DC-blocks and RF-chokes. The result of simulation of the LNA shows that a noise figure is less than 1.4dB and a gain is gloater than 9.2dB in the bandwidth of 10.7 to 12.7GHz with good flatness of 0. ldB

  • PDF

A Study of a High Performance Capacitive Sensing Scheme Using a Floating-Gate MOS Transistor

  • Jung, Seung-Min
    • Journal of information and communication convergence engineering
    • /
    • v.10 no.2
    • /
    • pp.194-199
    • /
    • 2012
  • This paper proposes a novel scheme of a gray scale fingerprint image for a high-accuracy capacitive sensor chip. The conventional grayscale image scheme uses a digital-to-analog converter (DAC) of a large-scale layout or charge-pump circuit with high power consumption and complexity by a global clock signal. A modified capacitive detection circuit for the charge sharing scheme is proposed, which uses a down literal circuit (DLC) with a floating-gate metal-oxide semiconductor transistor (FGMOS) based on a neuron model. The detection circuit is designed and simulated in a 3.3 V, 0.35 ${\mu}m$ standard CMOS process. Because the proposed circuit does not need a comparator and peripheral circuits, the pixel layout size can be reduced and the image resolution can be improved.

New Soft-Switching Current Source Inverter for a Photovoltaic Power System

  • Han, Byung-Moon;Kim, Hee-Jung;Baek, Seung-Taek
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.3B no.1
    • /
    • pp.37-43
    • /
    • 2003
  • This paper proposes a soft-switching current source inverter for a photovoltaic power system. The proposed inverter has an H-type switched-capacitor module composed of two semiconductor switches, two diodes, and an LC resonant circuit. The operation of the proposed system was analyzed by a theoretical approach with equivalent circuits and was verified by computer simulations with SPICE and experimental implementation with a hardware prototype. The proposed system could be effectively applied for the power converter of photovoltaic power system interconnected with the AC power system.

High voltage DC - DC boost converter by stacked structure (고전압 발생을 위한 스택 구조의 DC - DC boost 변환기)

  • Kim, Young-Jae;Nam, Hyun-Suk;Ahn, Young-Kook;Roh, Jeong-Jin
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.476-477
    • /
    • 2008
  • In this paper, high voltage DC- DC boost converters by stacked structure of power transistors are proposed. These stacked power transistors are tolerant to output voltage higher than the process limit for individual CMOS transistors. The proposed circuits were designed in a standard 3.6V, $0.13{\mu}m$.

  • PDF

Design of Power Factor Correction IC for 1.5kW System Power Module (1.5kW급 System Power Module용 Power Factor Correction IC 설계)

  • Kim, Hyoung-Woo;Seo, Kil-Soo;Kim, Ki-Hyun;Park, Hyun-Il;Kim, Nam-Kyun
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.499-500
    • /
    • 2008
  • In this paper, we design and implement the monolithic power factor correction IC for system power modules using a high voltage(50V) CMOS process. The power factor correction IC is designed for power applications, such as refrigerator, air-conditioner, etc. It includes low voltage logic, 5V regulator, analog control circuit, high-voltage high current output drivers, and several protection circuits. And also, the designed IC has standby detection function which detects the output power of the converter stage and generates system down signal when load device is under the standby condition. The simulation and experimental results show that the designed IC acts properly as power factor correction IC with efficient protective functions.

  • PDF

A Microcontroller-Based Lock-In Amplifier for Capacitive Sensors (용량형 센서를 위한 마이크로컨트롤러에 기반을 둔 록인 증폭기)

  • Kim, Cheong-Worl
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.24-28
    • /
    • 2014
  • A lock-in amplifier was proposed for capacitive sensor applications. This amplifier was based on a general-purpose microcontroller and had only a charge amplifier as analog circuits. All the other functions of lock-in amplifier except for the charge amplifier were implemented with firmware and the internal resources of the microcontroller. A rectangular signal, generated by the microcontroller, was used in a sensor-driving signal instead of a conventional sinusoidal signal. This makes it possible that the phase comparison circuit in the lockin amplifier is made with analog-to-digital converter, a timer and an interrupt controller. Using the oversampling method and the rectangular driving signal, we can make it easy to implement the peak detection function with software and sample the peak-to-peak signal at charge amplifier output. A charge amplifier was proposed to cancel out the base capacitance existing in capacitive sensors structurally. The experimental results show that the lock-in amplifier operating in the supply voltage of 3.0 V cancels out the base capacitance and has good linearity.

Implementation of 4 Channel Photo-Plethysmogram System(I) (4 채널의 Photo-plethysmogram 시스템 구현에 관한 연구(I))

  • Kim, Hyoung-Tae;Han, Soon-Chen;Kim, Jung-Kuk;Huh, Woong;Park, Young-Bae
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.253-256
    • /
    • 2002
  • In this paper, we implement the volume pulse detection system which can quantitatively represent an artery elasticity. The system consists of transducer which has IRLED-photodiode detecter, temperature sensor, filters, preprocessing circuits, A/D converter, serial communication part and computer system. In order to presume the artery elasticity information we measure the volume pulse at four points and then evaluate the transition time, distance and the correlation coefficient of the pulse wave between the points. We test the system with 10 subjects during the week for basic experiment and obtain the data at four points. As the result of experiment, we can detect normalized volume pulse wave and evaluated parameter with effectively.

  • PDF

A NEW CONTROL METHOD FOR CURRENT SHARING IN THE 12-PULSE PHASE-CONTROLLED RECTIFIER

  • Min, Byoung-Gwon;Baek, Byung-San;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.581-585
    • /
    • 1998
  • This paper presents the new current sharing control method of a 12-pulse phase-controlled rectifier(PCR) for a UPS. The control circuit of the 12-Pulse PCR with a parallel operating rectifier system is proposed to balance input currents and to reduce the harmonics of input current. The PCR is used widely in the industrial world, since its cost is much lower than that of the PWM converter and the composition of control circuits is simple. This system is developed and tested for a 3-phase 400KVA UPS system and the experimental results in this application are included.

  • PDF

Cargo Inspection System Design and Boundary-Scan Test (화물 검색시스템 구현 및 Boundary_Scan Test)

  • Kim, Bong-Su;Kim, In-Su;Yoo, Sun-Won;Kim, Sung-Won;Lee, Sun-Wha;Yi, Yun;Han, Bum-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.197-200
    • /
    • 2002
  • We newly developed the procedures of X-ray Cargo inspection system with acquisition of multi-channel data, analog to digital converter and post logic circuit which is controlled by the FPGA. The IEEE1149.1 standard defines a four-wire serial interface(a fifth wire is optional)to access complex integrated circuits(ICs) such as PLD. This paper describes that Boundary_Scan test method applied to our home made cargo inspection system.

  • PDF

Power Factor improvement of Power Conversion Equipment for High Pressure Sodium Lamps (고압 나트륨 램프 구동용 전력변환장치의 역률 개선)

  • Lee, S.H.;Suh, K.Y.;Lee, H.W.;Lee, S.H.;Mun, S.P.
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.147-150
    • /
    • 2002
  • HPSL(High Pressure Sodium lamp)have attracted much attention in recent years, because they offer high luminous efficiency and very long life. Recently, AC-DC converters have been widely as power factor improvement circuits in the power conversion equipment An application of the ZVT-PWM(Zero Voltage Transition Pulse Width Modulation) boost converter, which has great advantage on miniaturization and high power density, to the power factor improvement circuit of the HPSL inverter are described to identify the power factor correction characteristics of the inverter. In this paper the series-parallel resonant inverter(electronic ballast) for driving a HPS lamp is discussed. Finally, a power factor corrector is cascaded in front of the electronic ballast. Consequently, a high power factor above 0.99 and low THD on the line current can be achieved.

  • PDF