• Title/Summary/Keyword: Conventional scan

Search Result 397, Processing Time 0.031 seconds

Influence of Resin-Infiltrated Time on Wood Natural Materials Using Conventional/Air-Coupled Ultrasound Waves

  • Park, Je-Woong;Kim, Do-Jung;Kweon, Young-Sub;Im, Kwang-Hee;Hsu, David K.;Kim, Sun-Kyu;Yang, In-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.3
    • /
    • pp.235-241
    • /
    • 2009
  • Composite wood materials are very sensitive to water and inspection without any coupling medium of a liquid is really needed to wood materials due to the permeation of coupling medium such as water. However, air-coupled ultrasound has obvious advantages over water-coupled experimentation compared with conventional C-scanner. In this work, it is desirable to perform contact-less nondestructive evaluation to assess wood material homogeneity. A wood material was nondestructively characterized with non-contact and contact modes to measure ultrasonic velocity using automated data acquisition software. We have utilized a proposed peak-delay measurement method. Also through transmission mode was performed because of the main limitation for air-coupled transducers, which is the acoustic impedance mismatch between most materials and air. The variation of ultrasonic velocity was found to be somewhat difference due to air-coupled limitations over conventional scan images. However, conventional C-scan images are well agreed with increasing the resin-infiltrated time as expected. Finally, we have developed a measurement system of an ultrasonic velocity based on data acquisition software for obtaining ultrasonic quantitative data for correlation with C-scan images.

Three-dimensional printed complete denture fabrication using the scan data from the conventional denture-making process (통상적인 총의치 제작과정에서의 스캔 정보를 활용한 three-dimensional printed complete denture의 제작)

  • Kim, Hyun-Min;Kim, Jong-Jin;Lee, Joo-Hee;Cha, Hyun-Suk;Baik, Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.3
    • /
    • pp.196-202
    • /
    • 2020
  • Recently three-dimensional (3D) printed complete dentures are becoming more widely recognized as one of the treatment options for the edentulous patients. Korean National Healthcare, however, has not yet approved the application of the 3D printed dentures, and in the cases where the dentures should be refabricated, the conventional fabrication process needs to be entirely repeated. However, during the conventional process, the digital scan data of some key steps could be easily obtained. In this clinical case, using these data, a new pair of 3D printed dentures that improved the limitations of the first conventional dentures were successfully fabricated.

Development of Delay Test Architecture for Counter (카운터 회로에 대한 지연결함 검출구조의 개발)

  • 이창희;장영식
    • Journal of the Korea Society of Computer and Information
    • /
    • v.4 no.1
    • /
    • pp.28-37
    • /
    • 1999
  • In this paper. we developed a delay test architecture and test procedure for clocked 5-bit asynchronous counter circuit based on boundary scan architecture. To develope, we analyze the problems of conventional method on delay test for clocked sequential circuit in boundary scan architecture. This paper discusses several problems of delay test on boundary scan architecture for clocked sequential circuit. Conventional test method has some problems of improper capture timing, of same pattern insertion, of increase of test time. We suggest a delay test architecture and test procedure, is based on a clock count-generation technique to generate continuous clocks for clocked input of CUT. The simulation results or 5-bit counter shows the accurate operation and effectiveness of the proposed delay test architecture and procedure.

  • PDF

OCCLUSION AND VERTICAL DIMENSION CHANGES ACCORDING TO DENTURE PROCESSING TECHNIQUES (총의치 온성방법에 따른 교합 및 수직 고경의 변화)

  • Kim, Mun-Young;Chung, Kwan-Ho;Yu, Hyoung-Woo;Ahn, Seung-Geun;Song, Kwang-Yeob;Park, Charn-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.2
    • /
    • pp.277-289
    • /
    • 1996
  • The purpose of this study was to compare the amount of the vertical pin opening of dentures processed by the conventional compression method & the injection-processing method. The articulating ribbon and T-Scan system were used to determine the changes in tooth contacts and the correlation between the changes in tooth contacts and the amount of the vertical pin opening after processing was analyzed statistically. The obtained results were as follows. 1. The amounts of the vertical pin opening were 0.75mm, 0.31mm for conventional compression method and injection-pressing method, respectively. The difference between the two methods was highly significant on the basis of t test statistics(p<0.05). 2. The total number of contact points recorded by articulating ribbon after processing was decreased to 48%, 72%, of that before processing for conventional compression method and injection-pressing method, by T-Scan system, 39%, 53%, respectively. 3. The mean values for the number of contacts points per tooth recorded by articulating ribbon after processing were 1.6 for the second molar, 2.2 for the first moalr, 0.4 for the second premolar, 0.6 for the first premolar in conventional compression method, and 2, 3.2, 1.2, 0.8 in injection-pressing method. 4. The correlation between the reduction of contact points and the amount of the pin opening after processing was not significant. 5. The mean values for the number of contact points per tooth recorded by T-Scan system after processing were 1.25, 1.4, 0.7, and 0.55 at the second molar, the first molar, the second premolar, and the first premolar in conventional compression method, and 1.45, 2.1, 1.0, 0.75 in injection method, respectively. 6. The correlation between the number of contact points by using articulating ribbon and T-Scan system after processing was not significant in both methods.

  • PDF

3D Image Scan Automation Planning based on Mobile Rover (이동식 로버 기반 스캔 자동화 계획에 대한 연구)

  • Kang, Tae-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.1-7
    • /
    • 2019
  • When using conventional 3D image scanning methods, it is common for image scanning to be done manually, which is labor-intensive. Scanning a space made up of complicated equipment or scanning a narrow space that is difficult for the user to enter, is problematic, resulting in quality degradation due to the presence of shadow areas. This paper proposes a method to scan an image using a rover equipped with a scanner in areas where it is difficult for a person to enter. To control the scan path precisely, the 3D image remote scan automation method based on the rover move rule definition is described. Through the study, the user can automate the 3D scan plan in a desired manner by defining the rover scan path as the rule base.

The diagnostic value of i-scan image-enhanced endoscopy in the diagnosis of oral cavity leukoplakia (구강 백반증 진단에 있어서 i-scan image-enhanced 내시경의 진단적 유용성)

  • Lee, Young Chan;Eun, Young-Gyu;Park, Il-Seok
    • Korean Journal of Head & Neck Oncology
    • /
    • v.34 no.2
    • /
    • pp.29-34
    • /
    • 2018
  • Background/Objectives: The aim of this study was to investigate the diagnostic value of i-scan in the differential diagnosis of oral cavity leukoplakia based on visualization of abnormal vascular features. Materials & Methods: Thirty- one patients with oral cavity leukoplakia were enrolled in the study. Images of their oral cavity obtained using conventional white light endoscopy and an i-scan-enhanced endoscopy (Pentax DEFINA EPK-3000 Video Processors, with Pentax VNLJ10) were reviewed. The microvascular features of the lesions and vascular changes were analyzed and the results were compared with the histopathologic diagnosis. Results: Among the 31 oral cavity leukoplakia patients, 8 (25.8%) patients revealed hyperkeratosis, 10 (31.2%) low-grade dysplasia, 5 (16.2%) high-grade dysplasia and 8 (25.8%) invasive squamous cell carcinoma on histopathologic examination. Using i-scan-enhanced endoscopy, we could found abnormal vascular change with neoplastic neoangiogenesis in most high-grade dysplasia or invasive cancer in oral cavity. (high-grade dysplasia: 4/5 [80.0%], and invasive squamous cell carcinoma: 7/8 [87.5%]). Conclusion: i-scan-enhanced endoscopy could be a useful optical technique for the diagnosis of oral cavity leukoplakia. Our results suggest that i-scan may be a promising diagnostic tool in the early detection of suspected oral mucosal lesion.

Radarsat-1 ScanSAR Quick-look Signal Processing and Demonstration Using SPECAN Algorithm (SPECAN 알고리즘을 이용한 Radatsat-1 ScanSAR Quick-look 신호 처리 및 검증 알고리즘 구현)

  • Song, Jung-Hwan;Lee, Woo-Kyung;Kim, Dong-Hyun
    • Korean Journal of Remote Sensing
    • /
    • v.26 no.2
    • /
    • pp.75-86
    • /
    • 2010
  • As the performance of the spaceborne SAR has been dramatically enhanced and demonstrated through advanced missions such as TerraSAR and LRO(Lunar Reconnaissance Orbiter), the need for highly sophisticated and efficient SAR processor is also highlighted. In Korea, the activity of SAR researches has been mainly concerned with SAR image applications and the current SAR raw data studies are mostly limited to stripmap mode cases. The first Korean spaceborne SAR is scheduled to be operational from 2010 and expected to deliver vast amount of SAR raw data acquired from multiple operational scenarios including ScanSAR mode. Hence there will be an increasing demand to implement ground processing systems that enable to analyze the acquired ScanSAR data and generate corresponding images. In this paper, we have developed an efficient ScanSAR processor that can be directly applied to spaceborne ScanSAR mode data. The SPECAN(Spectrum Analysis) algorithm is employed for this purpose and its performance is verified through RADARSAT-1 ScanSAR raw data taken over Korean peninsular. An efficient quick-look processing is carried out to produce a wide-swath SAR image and compared with the conventional RDA processing case.

Comparison on Track Formation Range between TWS and Adaptive Tracking Using Markov Chain Analysis in a Radar System (레이더에서의 Markov Chain 분석을 이용한 TWS 방식과 Adaptive Tracking 방식의 추적 형성 거리 비교)

  • Ahn, Chang-Soo;Roh, Ji-Eun;Jang, Sung-Hoon;Kim, Seon-Joo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.5
    • /
    • pp.574-580
    • /
    • 2013
  • Compared with the TWS(Track While Scan) tracking that uses scan-to-scan correlation at search illuminations for targets track, a phased array radar can use adaptive tracking which assigns additional track illuminations and the track formation range can be improved as a result. In this paper, an adaptive tracking, the search and track illuminations of a target are synchronized such that the extra illuminations are evenly distributed between the search illuminations, is proposed. Markov chain and track formation range for the proposed adaptive tracking are shown with them for the conventional TWS. The simulation result shows that the proposed adaptive tracking has improved track formation range by 27.6 % compared with the conventional TWS tracking under same track confirmation criterion.

A Past Elimination Algorithm of Impossible Candidate Vectors Using Matching Scan Method in Motion Estimation of Full Search (전영역 탐색 방식의 움직임 예측에서 매칭 스캔 방법을 이용한 불가능한 후보 벡터의 고속 제거 알고리즘)

  • Kim Jone-Nam
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.8
    • /
    • pp.1080-1087
    • /
    • 2005
  • Significant computations for full search (FS) motion estimation have been a big obstacle in real-time video coding and recent MPEG-4 AVC (advanced video coding) standard requires much more computations than conventional MPEG-2 for motion estimation. To reduce an amount of computation of full search (FS) algorithm for fast motion estimation, we propose a new and fast matching algorithm without any degradation of predicted images like the conventional FS. The computational reduction without any degradation in predicted image comes from fast elimination of impossible candidate motion vectors. We obtain faster elimination of inappropriate motion vectors using efficient matching units from localization of complex area in image data and dithering order based matching scan. Our algorithm reduces about $30\%$ of computations for block matching error compared with the conventional partial distortion elimination (PDE) algorithm, and our algorithm will be useful in real-time video coding applications using MPEG-4 AVC or MPEG-2.

  • PDF

A ScanSAR Processing without Azimuth Stitching by Time-domain Cross-correlation (Azimuth Stitching 없는 ScanSAR 영상화: 시간영역 교차상관)

  • Won, Joong-Sun
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.3
    • /
    • pp.251-263
    • /
    • 2022
  • This paper presents an idea of ScanSAR image formation. For image formation of ScanSAR that utilizes the burst mode for raw signal acquisition, most conventional single burst methods essentially require a step of azimuth stitching which contributes to radiometric and phase distortions to some extent. Time-domain cross correlation could replace SPECAN which is most popularly used for ScanSAR processing. The core idea of the proposed method is that it is possible to relieve the necessity of azimuth stitching by an extension of Doppler bandwidth of the reference function to the burst cycle period. Performance of the proposed method was evaluated by applying it to the raw signals acquired by a spaceborne SAR system, and results satisfied all image quality requirements including 3 dB width, peak-to-sidelobe ratio (PSLR), compression ratio,speckle noise, etc. Image quality of ScanSAR is inferior to that of Stripmap in all aspects. However, it is also possible to improve the quality of ScanSAR image competitive to that of Stripmap if focused on a certain parameter while reduced qualities of other parameters. Thus, it is necessary for a ScanSAR processor to offer a great degree of flexibility complying with different requirements for different applications and techniques.