• Title/Summary/Keyword: Control-Volume Analysis

검색결과 932건 처리시간 0.025초

가압기 밀림관 수평배관 외부 가열에 의한 열성층 유동 완화 수치해석 (Numerical analysis for mitigating thermal stratification flow of pressurizer surge horizontal pipe by outside heating)

  • 정일석;김유
    • 대한기계학회논문집B
    • /
    • 제21권5호
    • /
    • pp.670-678
    • /
    • 1997
  • A method to mitigate the thermal stratification phenomenon of pressurizer surge line is proposed by heating bottom outside of horizontal pipe. Unsteady two dimensional model has been used to numerically investigate an effect of heating the bottom of pipe. The dimensionless governing equations are solved by using the control volume formulation and SIMPLE algorithm. Temperature and streamline profiles of fluids and pipe walls with time are compared with the previous study result. The numerical result of this study shows that the outside heating can relaxate the thermal stratification flow of the pressurizer surge line. Maximum dimensionless temperature difference between hot and cold sections of the pipe inner wall which causes thermal stratification was reduced from 0.514 to 0.424 at dimensionless time 1, 632 and 1, 500 respectively.

삼각형 요소의 형상 충전 및 격자 세분화를 이용한 붕괴하는 물 댐의 유한 요소 해석 (Finite Element Analysis of Collapse of a Water Dam Using Filling Pattern Technique and Adaptive Grid Refinement of Triangular Elements)

  • 김기돈;양동열;정준호
    • 대한기계학회논문집B
    • /
    • 제28권4호
    • /
    • pp.395-405
    • /
    • 2004
  • The filling pattern and an adaptive grid refinement based on the finite element method and Eulerian mesh advancement approach have been developed to analyze incompressible transient viscous flow with free surfaces. The governing equation for flow analysis is Navier-Stokes equation including inertia and gravity effects. The mixed FE formulation and predictor-corrector method are used effectively for unsteady numerical simulation. The flow front surface and the volume inflow rate are calculated using the filling pattern technique to select an adequate pattern among four filling patterns at each triangular control volume. By adaptive grid refinement, the new flow field that renders better prediction in flow surface shape is generated and the velocity field at the flow front part is calculated more exactly. In this domain the elements in the surface region are made finer than those in the remaining regions for more efficient computation. Using the proposed numerical technique, the collapse of a water dam has been analyzed to predict flow phenomenon of fluid and the predicted front positions with respect to time have been compared with the reported experimental results.

형상 충전 및 격자 세분화를 이용한 삼차원 자유 표면 유동의 유한 요소 해석 (Three Dimensional Finite Element Analysis of Free Surface Flow Using Filling Pattern Technique and Adaptive Grid Refinement)

  • 김기돈;양동열;정준호
    • 대한기계학회논문집B
    • /
    • 제28권11호
    • /
    • pp.1348-1358
    • /
    • 2004
  • The filling pattern and an adaptive grid refinement based on the finite element method and Eulerian mesh advancement approach have been developed to analyze incompressible transient viscous flow with free surfaces. The governing equation fur flow analysis is Navier-Stokes equation including inertia and gravity effects. The mixed FE formulation and predictor-corrector method are used effectively for unsteady numerical simulation. The flow front surface and the volume inflow rate are calculated using the filling pattern technique to select an adequate pattern among seven filling patterns at each tetrahedral control volume. By adaptive grid refinement, the new flow field that renders better prediction in flow surface shape is generated and the velocity field at the flow front part is calculated more exactly. In this domain the elements in the surface region are made finer than those in the remaining regions for more efficient computation. The collapse of a water dam and the filling of a fluidity spiral have been analyzed. The numerical results have been in good agreement with the experimental results and the efficiency of the adaptive grid refinement and filling pattern techniques have been verified.

Effect of Burn on the Cardiac Function in Rats - Ultrastructural Changes and Stereological Analysis

  • Moon, Hye-Jung;Lee, Yoon-Jeong;Park, Won-Hark
    • 대한의생명과학회지
    • /
    • 제8권1호
    • /
    • pp.21-27
    • /
    • 2002
  • To investigate an effect of bum on the cardiac function, we studied some biochemical assay, ultrastructural changes and stereological analysis in heart tissue. Sprague-Dawley rats were induced a 15% total body surface area scald burn. 5 and 24 hours later, the heart was excised. Burned rats showed the decrease of heart weight per body weight (%) compared with control. The activity of serum aspartate aminotransferase was significantly increased at 5 (p<0.001) and 24 hours (p<0.01) after burn compared with control. And the activity of serum LDH was decreased at 5 hours after burn but increased at 24 hours compared with control. Ultrastructurally, enlargement of interstitium and destruction of sarcolemma were observed at 5 and 24 hours after burn. Especially at 5 hours postburn, hypercontraction band was noted and at 24 hours, wavy fiber and muscle fraying were noted. In stereological changes, volume density of mitochondria and myofibril was significantly decreased at postburn 5 and 24 hours. But volume density of sarcoplasmic reticulum was significantly increased at postburn 5 hours. Our data suggest that dermal scald bum causes myocardial dysfunction.

  • PDF

미세 방전 가공에서의 방전 펄스 카운팅을 이용한 간극 제어 (Gap Control Using Discharge Pulse Counting in Micro-EDM)

  • 정재원;고석훈;정영훈;민병권;이상조
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.499-500
    • /
    • 2006
  • The electrode wear in micro-EDM significantly deteriorates the machining accuracy. In this regard, electrode wear needs to be compensated in-process to improve the product quality. Therefore, there are substantial amount of research about electrode wear. In this study a control method for micro-EDM using discharge pulse counting is proposed. The method is based on the assumption that the removed workpiece volume is proportional to the number of discharge pulses, which is verified from experimental results analyzing geometrically machined volume according to various number of discharges. Especially, the method has an advantage that electrode wear does not need to be concerned. The proposed method is implemented to an actual micro-EDM system using high speed data acquisition board, simple counting algorithm with 3 axis motion system. As a result, it is demonstrated that the volume of hole machined by EDM drilling can be accurately estimated using the number of discharge pulses. In EDM milling process a micro groove without depth variation caused by electrode wear could be machined using the developed control method. Consequently, it is shown that machining accuracy in drilling and milling processes can be improved by using process control based on the number of discharge pulses.

  • PDF

Simply supported boundary condition for bifurcation analysis of functionally graded material: Thickness control by exponential fraction law

  • Shadi Alghaffari;Muzamal Hussain;Mohamed A. Khadimallah;Faisal Al Thobiani;Hussain Talat Sulaimani
    • Advances in nano research
    • /
    • 제14권4호
    • /
    • pp.303-312
    • /
    • 2023
  • In this study, the bifurcation analysis of functionally graded material is done using exponential volume fraction law. Shell theory of Love is used for vibration of shell. The Galerkin's method is applied for the formation of three equations in eigen value form. This eigen form gives the frequencies using the computer software MATLAB. The variations of natural frequencies (Hz) for Type-I and Type-II functionally graded cylindrical shells are plotted for exponential volume fraction law. The behavior of exponent of volume fraction law is seen for three different values. Moreover, the frequency variations of Type-I and -II clamped simply supported FG cylindrical shell with different positions of ring supports against the circumferential wave number are investigated. The procedure adopted here enables to study vibration for any boundary condition but for brevity, numerical results for a cylindrical shell with clamped simply supported edge condition are obtained and their analysis with regard various physical parameters is done.

경도인지장애와 알츠하이머병 환자의 18F-fludeoxyglucose PET 표준 섭취계수율에 대한 체적 및 피질 표면 기반 관심영역 분석 (Region of Interest Analysis for Standardized Uptake Value Ratio of 18F-fludeoxyglucose PET: Mild Cognitive Impairment and Alzheimer's Disease)

  • 김선직;윤의철
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권6호
    • /
    • pp.237-242
    • /
    • 2018
  • $^{18}F$-fludeoxyglucose PET (FDG-PET) can help finding an abnormal metabolic activity in brain. In this study, we evaluated an efficiency of volume- and cortical surface-based analysis which were used to determine whether standardized uptake value ratio (SUVR) of FDG-PET was different among Alzheimer's disease (AD), mild cognitive impairment (MCI), and healthy control (HC). Each PET image was rigidly co-registered to the corresponding magnetic resonance imaging (MRI) using mutual information. All voxels of the co-registered PET images were divided by the mean FDG uptake of the cerebellum cortex which was thresholded by partial volume effect (>0.9). Also, the SUVR value of each vertex was linearly interpolated from volumetric SUVR image which was thresholded by gray matter partial volume effect (>0.1). Lobar mean values were calculated from both volume- and cortical surface-based SUVRs. Statistical analysis was conducted to compare two measures for AD, MCI and HC groups. Even though the results of volume (SUVR_vol) and cortical surface-based SUVR (SUVR_surf) analysis were not significantly different from each other, the latter would be better for detecting group differences in SUVR of PET.

시계열분석(時系列分析)에 의한 배수량추정(配水量推定) (Estimation of Water Distributed Volume Using Time Series Analysis)

  • 이정환;정춘웅;오민환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 A
    • /
    • pp.340-343
    • /
    • 1992
  • In this paper, To estimate monthly water distribution volume required optimization control of operating scheme & water distribution management for water transmission system in water supply, both Thomas-Fiering technique and Fourier series are compared and analyzed, respectively. Since water distribution volume is periodically repeated and has a linear fluctuation trend, parameters in each element are estimated through dividing into linear fluctuation trend component and periodical component. Finally, results of time-series analysis are proved to be more reasonable than that of Thomas-Fiering techniques by comparing simulation with observation data.

  • PDF

고속도로 교통데이터(FTMS, TCS)를 이용한 경로전환율 분석: 서해안고속도로 매송~발안 구간을 중심으로 (Analysis of Diversion Rate using Expressway Traffic Data(FTMS, TCS): Focusing on Maesong~Balan IC at Seohaean Expressway)

  • 고한검;최윤혁;오영태;최기주
    • 대한교통학회지
    • /
    • 제30권3호
    • /
    • pp.31-41
    • /
    • 2012
  • VMS, 교통방송(라디오), SNS 등 교통정보제공을 통한 교통량 분산에 대한 관심이 높아짐에 따라 교통정보에 대한 운전자의 반응행태 및 효과에 대한 연구가 지속적으로 이루어지고 있다. 본 연구는 FTMS 및 TCS 데이터가 구축되어 있는 전국 고속도로 본선부를 분석 대상으로, FTMS 데이터와 TCS 데이터를 이용하여 경로전환 교통량과 그에 따른 경로전환율을 추정하는 방법론을 제시하고, 실제 대상구간의 경로전환율을 산출하여 시간 및 공간적 경로 전환율 변동에 대한 특성을 분석하였다. 본 연구에서는 교통정보 제공 이후, 해당 시간대의 평균 유출교통량에 비해 유출교통량이 일시적으로 증가한 경우 이 편차(도로교통상황의 동적인 특성으로 인한 편차 고려)는 교통정보 제공으로 인한 경로전환 교통량이라 정의하고, 본선 교통량과의 비율을 경로전환율로 계산하였다. 시간흐름에 따른 경로전환율 변화를 분석한 결과, 혼잡상황에 대한 교통정보를 먼저 얻게 되는 상류부 IC에서의 초기 경로전환율(유출교통량) 변화는 일시적으로 매우 큰 것으로 나타났다. 이후 공간적 시간적 흐름에 따라 상류부 IC에서의 경로전환율의 변화는 하류부 IC에서의 경로전환에 영향을 미치고, 이는 다시 상류부 IC에서의 변화를 유도하는 등의 경로전환 순환체계(feedback control loop)가 있음을 확인하였다.