• Title/Summary/Keyword: Control of Cracking

Search Result 354, Processing Time 0.031 seconds

Concrete stiffness matrices for membrane elements

  • Hsu, Thomas T.C.
    • Structural Engineering and Mechanics
    • /
    • v.5 no.5
    • /
    • pp.599-608
    • /
    • 1997
  • The concrete stiffness matrices of membrane elements used in the finite element analysis of wall-type structures are reviewed and discussed. The behavior of cracked reinforced concrete membrane elements is first described by summarizing the constitutive laws of concrete and steel established for the two softened truss models (the rotating-angle softened-truss model and the fixed-angle softened-truss model). These constitutive laws are then related to the concrete stiffness matrices of the two existing cracking models (the rotating-crack model and the fixed-crack model). In view of the weakness in the existing models, a general model of the matrix is proposed. This general matrix includes two Poisson ratios which are not clearly understood at present. It is proposed that all five material properties in the general matrix should be established by new biaxial tests of panels using proportional loading and strain-control procedures.

Autogenous Shrinkage of Concrete Containing Blast-Furnace Slag (고로 슬래그를 함유한 콘크리트의 자기 수축)

  • 이회근;권기헌;이광명;김규용;손유신
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.417-420
    • /
    • 2003
  • Concrete with low water to binder ratio (W/B) is prone to large autogenous shrinkage. Early age cracking of concrete would be caused by tensile stress induced by large autogenous shrinkage under restrained condition. Therefore, it is necessary to measure autogenous shrinkage to control the early age cracking of concrete. An objective of this study is to investigate the effects of W/B and blast furnace slag (BFS) on autogenous shrinkage of concrete. Autogenous shrinkage of concrete with various W/B ranging from 0.42 to 0.27 and BFS contents of 0, 30 and 50% were measured. Test results show that the autogenous shrinkage of concrete increases as the W/B decreases, and all BFS concretes showed larger autogenous shrinkage than OPC concretes with the same W/B. Moreover, the higher BFS content, the larger autogenous shrinkage.

  • PDF

Effect of Admixtures on Drying Shrinkage Crack of Hardened Cement Mortar (시멘트경화체의 건조수축균열에 미치는 혼화재의 영향)

  • 이승한;이종석
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.10a
    • /
    • pp.229-233
    • /
    • 1995
  • In this study we have the properties of drying shrinkage crack of hardened cement mortar using admixtures. The drying shrinkage cracking test process has been examined by the restrained drying shrinkage strain by restraining rate measuring properties of strain-with- restraint by JIS original proposal and keeps a flow value of mortar about 100$\pm$5%. The results show that the usage of shrinkage reducing agent 1.5% was effective on the control of drying shrinkage in OPC and CP by restraining rate 20% and strain-with-restraing 20~30 $\mu$, the usage of expansion agent 0.45% was effective by restraining rate 50~60% and strain-with-restraint 40~80$\mu$, and the effectiveness was increased with shrinkage reducing agent. Also. admixtures such as Flyash, CP and NC reduced restrained shrinkage and drying shrinkage cracking and more with shrinkage reducing agent

  • PDF

Crack Characteristics of Soil Concrete Using Volcaniclastic and the Crack Repair Method (화산쇄설물을 사용한 소일콘크리트의 균열특성과 보수방법에 관한 연구)

  • Hong, Chong-Hyun
    • Journal of Environmental Science International
    • /
    • v.19 no.6
    • /
    • pp.737-746
    • /
    • 2010
  • Restraint to drying shrinkage is the most common cause of concrete cracking. In many applications, drying shrinkage cracks are inevitable. In this paper, the surface cracks of soil concrete caused by drying shrinkage were considered to become an one of concrete textures. So, laboratory shrinkage tests were conducted and the results were applied to the field applications. The study results were summarized as follows; First, the use of vinyl sheets and concrete polymers helped to control the concrete cracking. Second, crack propagation usually started at the interfaces of soil concrete slabs and the cracks grew to the inner slabs. Third, surface cracks of soil concrete slabs could be an one of good concrete textures

Effect of applied Field on YBCO Superconductor in EPD Method (전기영동전착에서 YBCO 초전도 후막의 인가전계 영향)

  • Soh, Dea-Wha;Jeon, Yong-Woo;Choi, Sung-Jai;Park, Jung-Cheul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.63-66
    • /
    • 2003
  • The electrophoretic deposition method has the advantage of relatively few fabrication facilities and simple process procedure as well as the economical and technical merit of allowing various forms of deposition and easy control of deposition thickness and wire length. A study, especially electric field and additive, on the optimization method to increase the density of particles and uniformity of their orientation have been performed to overcome the cracking and the porosity problems in the fabricated superconductor.

  • PDF

Control of Shrinkage Cracking of Cement Composites with Different Length Mixture of PVA Fibers (서로 다른 길이의 PVA 섬유 혼합에 따른 시멘트 복합체의 균열제어 특성)

  • Won, Jong-Pil;Kim, Myung-Kyun;Park, Chan-Gi;Kim, Wan-Young;Park, Kyoung-Hoon;Jang, Chang-Il
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.405-408
    • /
    • 2006
  • The purpose of this study was to determine the optimum length distribution of hybrid PVA(Poly vinyl alcohol) fiber. To produce blended PVA fiber length, first the length distribution of PVA fiber in the cement composites were identified in an experimental study based on simplex lattice design. Among the different length distributions investigated, fiber length was found to have statistically significant effect on plastic shrinkage cracking of cement composites. Subsequently, Complex analysis techniques were used to devise an experimental program that helped determine the optimum combinations of the selected fiber length distribution based on plastic shrinkage crack. The optimum blended PVA length ratio was 0.0146% 4mm fiber, 0.0060% 6-mm fiber, 0.0285% 8-mm fiber, and 0.0209% 12-mm fiber.

  • PDF

An Experimental Study on Structural Behavior of Concrete Box Girder Member with Transverse Prestressing (PSC 박스거더 교량부재의 횡방향 프리스트레싱에 따른 구조거동 실험연구)

  • Oh Byung Hwan;Choi Young Cheol;Choi Jung Sun;Lee Seong Cheol
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.77-80
    • /
    • 2004
  • In bridge deck systems, deflections and cracking can be controlled by longitudinal and transverse prestressing, There are some benefits, longitudinal cracking control, the thickness reduction of deck slab, the widening of deck width and the reduction of the cross section area, in transversely post-tensioned concrete box girder bridges. However, it has been not sufficient to study the structural behaviors of transversely post-tensioned concrete box girder. Therefore, It is needed to predict the structural behaviors by prestressing and static loading. In this study, the analytical and experimental load tests are carried out to study the effect of transverse prestressing on concrete box girder. For these objectives, four test specimens are fabricated with various tendon spacing and steel ratio of top slab. The analytical and experimental studies are performed to estimate effects of the prestressing and failure tests.

  • PDF

Investigation of Internal Temperature and Relative Humidity of Concrete Immediately After Mix and Placement (양생직후 초기재령의 콘크리트 내부 온도와 상대습도의 측정 및 분석)

  • Park, Cheol-Woo;Park, Young-Hoon;Park, Yong-Gul
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1065-1068
    • /
    • 2008
  • Concrete is still one most common construction materials even in railway structures. As structures become massive and mega-sized, the importance of early age concrete quality control becomes more significant. Among various factors, relative humidity and temperature are the primary factors governing the early age quality. Temperature raise due to cement hydration causes stress, which can develop to cracking with internal and/or external restraints. Exposure conditions including ambient temperature, humidity and wind also significantly affect the cracking behavior of early age concrete. Among many of studies on the early age concrete behavior, investigation on the variation of temperature and relative humidity internal of concrete is not common. That is in part because the difficulties in measuring the relative humidity and temperature inside the concrete. This study used a digital sensor with an appropriate logger to measure internal temperature and relative humidity. This direct measuring method is expected to provide more reliable and comprehensive data acquisition on the early age behavior of concrete.

  • PDF

Evaluation of Crack Control Performance of the Concrete with Fiber Combination (섬유혼입 조건에 따른 콘크리트의 균열제어 성능 평가)

  • Park, Jae-Yong;Lee, Myoung-Ho;Kang, Byung-Hoi;Kim, Kyoung-Hoon;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.21-22
    • /
    • 2013
  • Nowadays, the fiber which mixed with concrete matrix always has low adhesion with cement paste. It's difficult to use fiber to reinforce the structure. For more adding fiber in concrete would cause some problems as the low flowability and surface polishing. Further study is needed in fiber using. In this research, further study in fiber reinforced concrete has been invested. Various fibers with different properties have been used to prevent cracking. Fiber reinforced concrete's fundamental properties as slump, air content, compressive strength and tensile strength have been tested. Optimum type of the fiber and optimum addition ratio of fiber has been invested to increase the utility of the fiber which used in concrete.

  • PDF

Parametric Studies on the Temperature and Thermal Stresses According to Construction Condition of RC Box Structures (철근콘크리트 박스구조물의 시공변수에 따른 수화온도 및 열응력 특성 비교 연구)

  • 오병환;최성철;이명섭;박해균;주태성;안경철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.47-52
    • /
    • 2002
  • Recently, the underground reinforced concrete(RC) box structures have been increasingly built in Korea. In such structures, the heat of hydration may cause serious cracking problems. The RC box structures are classified in this category that needs much attention to control the hydration heat during construction. The purpose of the present study is to analyse the parameters which are related to the thermal crackings of the box structures. In this study, the quantitative studies of thermal stresses according to construction conditions in the RC box structures are thoroughly analysed. Major influencing variables are studied through the finite element analysis which affect the thermal cracking of RC box structures.

  • PDF