• Title/Summary/Keyword: Control Cable

Search Result 503, Processing Time 0.023 seconds

A Study on Validation Methodology of Fire Retardant Performance for Cables in Nuclear Power Plants (원자력발전소 케이블 난연성능 검증 방법론 개선을 위한 연구)

  • Lee, Sang Kyu;Moon, Young Seob;Yoo, Seong Yeon
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.1
    • /
    • pp.140-144
    • /
    • 2017
  • Fire protection for nuclear power plants should be designed according to the concept of "Defense in Depth" to achieve the reactor safety shutdown. This concept focuses on fire prevention, fire suppression and safe shutdown. Fire prevention is the first line of "Defense in Depth" and the licensee should establish administrative measures to minimize the potential for fire to occur. Administrative measures should include procedures to control handling and use of combustibles. Electrical cables is the major contributor of fire loads in nuclear power plants, therefore electrical cables should be fire retardant. Electrical cables installed in nuclear power plants should pass the flame test in IEEE-383 standard in accordance with NUREG-0800, "Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants". To assure the fire retardant of electrical cables during design life, both aged and unaged cable specimens should be tested in accordance with IEEE-383. It can be generally thought that the flammability of electrical cables has been increased by wearing as time passed, however the results from fire retardant tests performed in U.S.A and Korea indicate the inconsistent tendency of aging and consequential decrease in flammability. In this study, it is expected that the effective methodology for validation of fire retardant performance would be identified through the review of the results from fire retardant tests.

The Development of the ±80kV 60MW HVDC System in Korea

  • Park, Kyoung-Ho;Baek, Seung-Taek;Chung, Yong-Ho;Jang, Gil-Soo
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.594-600
    • /
    • 2017
  • HVDC transmission systems can be configured in many ways to take into account cost, flexibility and operational requirements. [1] For long-distance transmission, HVDC systems may be less expensive and suffer lower electrical losses. For underwater power cables, HVDC avoids the heavy currents required to charge and discharge the cable capacitance of each cycle. For shorter distances, the higher cost of DC conversion equipment compared to an AC system may still be warranted, due to other benefits of direct current links. HVDC allows power transmission between unsynchronized AC transmission systems. Since the power flow through an HVDC link can be controlled independently of the phase angle between the source and the load, it can stabilize a network against disturbances due to rapid changes in power. HVDC also allows the transfer of power between grid systems running at different frequencies, such as 50 Hz and 60 Hz. This improves the stability and economy of each grid, by allowing the exchange of power between incompatible networks. This paper proposed to establish Korean HVDC technology through a cooperative agreement between KEPCO and LSIS in 2010. During the first stage (2012), a design of the ${\pm}80kV$ 60MW HVDC bipole system was created by both KEPCO and LSIS. The HVDC system was constructed and an operation test was completed in December 2012. During the second stage, the pole#2 system was fully replaced with components that LSIS had recently developed. LSIS also successfully completed the operation test. (2014.3)

Development of Neuromuscular Stimulus System using Wearable Ultra-miniature Lighting Modules and its Verification of Clinical Effectiveness (의복형 초소형 발광모듈을 이용한 신경근육 자극 시스템 개발 및 임상적 효과 검증)

  • Park, Se-Hyeong;Lee, Jong-Shill;Kim, In-Young;Kim, Sun-I.
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.1
    • /
    • pp.23-33
    • /
    • 2009
  • It can be used easily to reduce rehabilitation and treatment time if diagnostic and therapeutic devices are attached to cloth or body. Therefore we developed neuromuscular wearable ultra-miniature lighting modules which can improve the neuromuscular function and verified its clinical effectiveness. The system is based on the ultra-miniature lighting treatment module and there are two types of systems. One of them is designed as an attached type and the other type is combined with clothing. The wearable ultra-miniature lighting module is composed of controller (battery, MCU, bidirectional transmitter and receiver), cable, treatment medium generating device and other peripheral devices. To verify the clinical effectiveness of this device, we observed the difference of the strength of a muscle before and after 650nm and 25mW laser irradiation on the reflex point for 1 to 4 seconds. Among 48 patients having the degenerative osteoarthritis, the muscle strength before and after irradiation of laser was $21.8{\pm}7.99$ and $27.3{\pm}8.43$. According to the result, the muscle strength after treatment was significantly increased (p<0.01). To whom having difficulty in visiting to OPD(Out-Patient Department), doctors medically examine the patients and find the therapeutic point, attachment of this wearable ultra-miniature lighting module can function as self treatment (treating instrument) and treatment assist at home. If doctor can remotely control the patient and take part in treatment, the therapeutic device could contribute to prevention and care device.

4-Way Power Divider Based on Substrate Integrated Waveguide for Satellite Communications (기판 집적 도파관 기술을 이용한 위성 통신용 4분기 전력 분배기)

  • Seo, Tae-Yoon;Lee, Jae-Wook;Lee, Taek-Kyung;Cho, Choon-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.8
    • /
    • pp.721-728
    • /
    • 2009
  • Equal/unequal 4-way power divider suitable for satellite communication using SIW technology is presented in this paper. The control of positions of guiding posts provides equal or unequal power division ratios by maintaining the width of the SIW unchanged. In addition, the detailed descriptions for the proposed power divider include the general characteristics of radial waveguide, feeding part using coaxial cable, simple SIW structure, power-guiding posts, and transition for measurement. The comparison between the simulated and measured data shows a good agreement at a center frequency of 10 GHz. The measured input impedance bandwidths for equal and unequal power divisions are about 2.1 GHz and 3 GHz under the condition of less than VSWR 2:1, respectively.

An Instantaneous Integer Ambiguity Resolution for GPS Real-Time Structure Monitoring (GPS 실시간 구조물 모니터링을 위한 반송파 관측데이터 순간미지정수 결정)

  • Lee, Hungkyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.1
    • /
    • pp.341-353
    • /
    • 2014
  • In order to deliver a centimeter-level kinematic positioning solution with GPS carrier-phase measurements, it is prerequisite to use correctly resolved integer ambiguities. Based on the mathematical modeling of GPS network with application of its geometrical constraints, this research has investigated an instantaneous ambiguity resolution procedure for the so-called 'integer constrained least-squares' technique which can be effectively implemented in real-time structure monitoring. In this process, algorithms of quality control for the float solutions and hypothesis tests using the constrained baseline for the ambiguity validation are included to enhance reliability of the solutions. The proposed procedure has been implemented by MATLAB, the language of technical computing, and processed field trial data obtained at a cable-stayed bridge to access its real-world applicability. The results are summarized in terms of ambiguity successful rates, impact of the stochastical models, and computation time to demonstrate performance of the instantaneous ambiguity resolution proposed.

Verification Method to Detect the Fake Test Data in Military Supplies (군수업체 시험 데이터 및 시험 시스템 유효성 점검을 위한 제언)

  • Chung, Ilhan;Joo, Jinchun;Kim, Sunggon;Cho, Hyeonghwan;Ahn, Namsu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.231-240
    • /
    • 2016
  • Recently, fake test data of power cables in nuclear power plants was a terrible shock to the citizens. Some cable companies manipulated the test data to make unfair profits. In addition, fake test data cases were found in military supplies. The fake test data cases focused on parts of army's tank, armored car. This paper propose a new method that can detect fake test data using known statistical methods. In addition, the method was implemented in Microsoft Excel to allow easy use. Lastly, a check sheet was proposed to check the validity of the test system of military suppliers. By detecting and checking the fake test data, it is expected that our new method will play an important role in quality assurance of military supplies.

A Study on the Stratum Thickness Arrangement and Roof Bolt Support Design using Robust Design (강건설계를 이용한 층서두께 배열과 루프볼트 지보설계에 관한 연구)

  • Jang, Myoung Hwan
    • Tunnel and Underground Space
    • /
    • v.28 no.2
    • /
    • pp.142-155
    • /
    • 2018
  • The ${\bigcirc}{\bigcirc}$ mine has irregularly developed stratum around the ore body. The purpose of this study is to array irregular stratum thickness systematically for effective roof bolting and to implement a supporting system corresponding to it. The number of 81 cases combined with stratum thicknesses was limited to 9 cases by robust design. For each case, the load height which can act as a roof load was determined by the characteristics of stratum and RMR. The load range due to the load height is calculated assuming block shaped and arch shape. The support load of the roof bolt was considered as the average load of the two methods. Numerical analysis results of the support design showed that the cable bolt was more effective for the roof supporting fully grouted than the anchoring type. As a result of the construction, it was possible to control the roof, but all of the roof was gradually sinking downward due to the deformation of the side wall of the mine tunnel.

Wireless image processing based management system the driver of the vehicle (무선 영상처리 기반의 차량 운전자 관리 시스템)

  • Seo, Ji-Hwan;Lee, Jae-Hyun;Kang, Sung-In;Shin, Dong-Suk;Kim, Kwan-Hyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.11
    • /
    • pp.2349-2354
    • /
    • 2009
  • Due to growth of electronics and control devices, automation and situational awareness systems have been applied by automobile. Vision systems with the introduction of unmanned system being actively developed, but are still high price and visual information is passed through the cable, because of cars are difficult to install. In this paper, can be installed inside the car at low-cost, simple image processing device through a wireless communication know the obstacles and the alarm system based on Zigbee wireless communication, infrared and ultrasonic sensors to monitor the situation through with easy parking cars outside the system design was implemented.

Performance evaluation of BWA protocol according to uplink frame size and contention slot (상향링크의 프레임 크기와 경쟁슬롯에 따른 BWA 프로토콜의 성능평가)

  • Oh Sung-Min;Kim Jae-Hyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.11B
    • /
    • pp.967-973
    • /
    • 2004
  • DOCSIS and IEEE 802.16 define the usage and element of a MAP which is uplink control message. Standards does not include the details of MAP size and the number of contention slots affecting the performance of MAC protocols for DOCSIS and IEEE 802.16. In this paper, we analyzed the performance of throughput and access delay according to the MAP size and contention slot size. Based on the analytical results, we found the optimal MAP size and the number of contention slots. We found that the protocol shows best performance when the MAP size is 2msec and the number of contention slots is 8. The simulation results can apply to the network system parameters. The simulator can be used to optimize the system parameters in cable network, BWA and WiBro.

Implementation of Sensor Controller and Monitering System Using Film Type (필름형 센서를 이용한 센서 제어기 및 모니터링 시스템 구현)

  • Park, No-Jin;Lee, Ho-Woong;Yu, Hong-Kyeun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.1
    • /
    • pp.51-57
    • /
    • 2013
  • Leak detection, the system is controlled by humanity's precious water resources, prepare for natural disasters and prevent damage to buildings and various industrial facilities. Especially because it causes serious environmental pollution, chemicals or oil spills, leak detection of various liquid(oil, water), the point at which the liquid leak is detected early on, and minimize environmental pollution, prevent damage of the equipment due to the leak, and the country's precious water resources to be used safely. In this paper, we solve these problems by using specialized film sensor, any person who is not a skilled technician, equipment or walls anywhere can be easily installed. also reduce unnecessary circuit, If film sensor is connected to operate, have a big competitive price, the detection of liquid and the surrounding environment according to, the sensor film that can set the sensitivity control, and monitoring system was implemented.